Remove and off haul 185 lf of existing chain-link fence and appurtenances.

Install 3 strand barb wire w/ barb wire support arms on top of new barrier fence per

UFGS 32-31-13.53.

Install 10' high x 12' wide commercial chain link double gate with 3 strand barb wire, barb wire supporting arms, 9 gauge per UFGS 32-31-13.53. Include 2 lf of 10' high chain link fence w/ 3 strand barb wire on each side of gate. Total width of gate and fencing to be 16 lf. Gate to be outward swing.

Existing 2" conduit with telephone conductor to be removed from existing chain link fence prior to fence removal. A new underground conduit/telephone conductor will be connected to the existing conduit/telephone conductor at the new chain link gate and will be installed parallel to the new barrier fence. New conduit/telephone conductor will tie back into the existing infrastructure near the overhead power platform. Telephone service to/from the power plant can not be interrupted, so all communication work must be completed prior to removal of the existing chain link fence.

Exhibit 1 - Fencing & Telephone, Pine Flat Landslide Risk Reduction Project