RTA_FAPH_MARSOC_STORAGE_BLDG_DWGS.pdf
PDF 21 MB Posted
- Attached to
- New Amendment for MARSOC Storage Shed - W9123618B0021 Federal contract opportunity
- Solicitation number
- W9123618B0021
About this file
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B.01.02_-_Bid_Abstract_-_MARSOC.pdf | ||
| B.01.02_-_Bid_Abstract_-_Culverts.pdf | ||
| REVISED__SECTION_13_34_19_9_17_2018.pdf | ||
| REVISED_SHEET_A-151_9_17_2018.pdf | ||
| MARSOC_-_Amendment_5_-_release.pdf | ||
| REVISED__SECTION_10_14_00.10_9_18_2018.pdf | ||
| REVISED_SHEET_I-101_9_17_2018.pdf | ||
| Amendment_4_MARSOC.pdf | ||
| A.07.24_Amendment_0003_W9123618B0021.doc.pdf | ||
| A.07.24_Amendment_0002_W9123618B0021.doc.pdf | ||
| A.01.25_Site_Visit_Sign-in_Sheet_MARSOC.pdf | ||
| A.07.24_Amendment_0001_W9123618B0021.pdf | ||
| A.07.23_Solicitation_W9123618B0021.pdf | ||
| RTA__FAPH_MARSOC_STORAGE_BLDG_-_FFandE_for_IFB.pdf | ||
| RTA_FAPH_MARSOC_STORAGE_BLDG_Specifications_-_17Aug18.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"BUILDING STRONG"
HENDRICK.SAMUEL.E.1410847023
Digitally signed by HENDRICK.SAMUEL.E.1410847023 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=HENDRICK.SAMUEL.E.1410847023 Date: 2018.07.31 10:41:27 -04'00'
DEGLANDON.TERRY.L.1246002483
Digitally signed by DEGLANDON.TERRY.L.1246002483 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=DEGLANDON.TERRY.L.1246002483 Date: 2018.07.31 10:47:05 -04'00'
FROMME.CHERYL.
L.1088650537
Digitally signed by
FROMME.CHERYL.L.1088650537
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=FROMME.CHERYL.L.1088650537 Date: 2018.07.31 14:03:29 -04'00'
1 2 3 4
D
C
B
A
STORAGE BAY
TOTAL DISTANCE = 43'
FE
K
FE
TYPE ABC FIRE EXTINGUISHER BRACKET MOUNTED
EXIT EGRESS CAPACITY
PATH OF TRAVEL
FIRE DEPARTMENT KEY BOX
OCCUPANT LOAD
OCCUPANT LOAD FACTOR (NFPA 101-TABLE 7.3.1.2)
K
FE
LIFE SAFETY LEGEND
BUILDING AND LIFE SAFETY CODE ANALYSIS
TOPIC DESIGN REFERENCE DESCRIPTION
1. GOVERNING CODES AND CRITERIA UFC 3-600-01 UNIFIED FACILITIES CRITERIA, FIRE PROTECTION ENGINEERING
FOR FACILITIES, CHANGE 1, 28 NOV 2016
IBC INTERNATIONAL BUILDING CODE, 2015 EDITION
NFPA 101 NATIONAL FIRE PROTECTION ASSOCIATION, LIFE SAFETY
CODE, 2015 EDITION
2. OCCUPANCY CLASSIFICATION
3. CONSTRUCTION TYPE TYPE II-B IBC, 602.2, TABLE 601 NONCOMBUSTIBLE, UNPROTECTED CONSTRUCTION
4. STRUCTURAL FIRE RESISTANCE SEE DESCRIPTION IBC TABLE 601 PRIMARY STRUCTURAL FRAME: 0 HOURS
BEARING WALLS, EXTERIOR: 0 HOURS
NONBEARING WALLS AND PARTITIONS, EXTERIOR: 0 HOURS
ROOF CONSTRUCTION AND SECONDARY MEMBERS: 0 HOURS
5. AUTOMATIC SPRINKLERS NOT PROVIDED UFC 3-600-01, 4-2.2 NOT REQUIRED SINCE GREATER THAN 5,000 SF
6. PORTABLE FIRE EXTINGUISHERS PROVIDED, TYPE AND SPACING PER NFPA 10 NFPA 101, 42.3.5 NOT REQUIRED
7. FIRE DETECTION, ALARM, AND EVACUATION SYSTEM NOT PROVIDED NFPA 101, 42.3.4
8. MEANS OF EGRESS, OCCUPANT LOAD
9. NUMBER OF MEANS OF EGRESS NFPA 101, 7.4.1.2 2 REQUIRED
10. EGRESS DISTANCE LIMITATIONS
GROUP S-1, STORAGE IBC, 311.2 MODERATE HAZARD STORAGE
NOT REQUIRED
STORAGE ROOMS, 1 HOUR FIRE BARRIERS NFPA 101, TABLE 7.1.3.2 500 SF / OCCUPANT, MINIMUM 1 OCCUPANT PER ROOM
NFPA 101, TABLE A.7.6 MAX TRAVEL DISTANCE PATH REQUIRED = 200 FEET
MAX COMMON PATH REQUIRED = 100 FEET
STORAGE
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
4:
:3
PM
LS101
BU
IL
D
IN
G
L
IF
E
SA
F E
TY
C O
D E
AN
AL
Y S
IS
A N
D
FL
O O
R P
L A N
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
R . N
AG
EL
E.
M
O R
TO
N
S.
G
EO
R
G E
Z.
G
R O
SE
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 2 OF 51
SCALE: 1/8" = 1'-0"
STORAGE BUILDING FLOOR PLAN - LIFE SAFETY
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
NO SCALE
NORTH
KEY PLAN
STORAGE BLDG
CANDIDATE ISOLATION
CLASSROOM
ADMIN & OPERATIONS
1. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO THE
REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, HANGERS AND ANCHORS.
2. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [+/-X'-X"]
REFERENCED TO THE FINISHED FLOOR TOP OF SLAB ELEVATION DATUM SET AT +0'-0".
THIS DATUM IS EQUIVALENT TO THE TOP OF SLAB ELEVATION INDICATED ON THE CIVIL
DRAWINGS.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLETELY UNDERSTAND
THE DESIGN AS SHOWN ON THESE DRAWINGS AND ASSOCIATED SPECIFICATIONS.
THE CONTRACTOR SHALL REPORT DISCREPANCIES, OMISSIONS, ETC. TO THE
CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE
AFFECTED.
4. DETAILS ENTITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE
SPECIFICALLY INDICATED OR REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE
THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE. DETERMINE
APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE
SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE
DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
5. THE STRUCTURAL DRAWINGS CONTAINED HEREIN REPRESENT THE FINISHED
STRUCTURE. PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT
AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK,
INCLUDING CONNECTIONS, IS COMPLETE. THE ANALYSIS, DESIGN, SAFETY, ADEQUACY
AND INSPECTION OF ERECTION BRACING, SHORING, AND OTHER TEMPORARY
SUPPORTS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND SUPERVISION
OF THE WORK ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
7. REPRODUCTION OF CONTRACT DRAWINGS FOR USE AS SHOP DRAWINGS SHALL
NOT BE PERMITTED UNDER ANY CIRCUMSTANCES.
8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL FINAL
CONSTRUCTION DOCUMENTS DEVELOPED FROM THESE PLANS AND ASSOCIATED
SPECIFICATIONS COMPLY WITH ALL APPLICABLE DESIGN REQUIREMENTS OF ANY
GOVERNING AUTHORITY AND OBTAIN THE APPROPRIATE APPROVALS AND/OR PERMITS
AS MAY BE REQUIRED FROM LOCALITY, STATE OR FEDERAL AGENCY.
GENERAL NOTES
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE
AMERICAN CONCRETE INSTITUTE (ACI). SLABS ON GRADE SHALL ADHERE TO THE MOST
CURRENT EDITION OF TM5-809-1.
2. CAST-IN-PLACE CONCRETE PROPERTIES:
A. MINIMUM COMPRESSIVE STRENGTH (f'c) 4000 PSI
3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT UNLESS OTHERWISE NOTED.
4. MINIMUM CONCRETE SLAB THICKNESS SHALL BE AS NOTED - SEE PLANS AND DETAIL
A1/S-502.
5. UON WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A185. PROVIDE FLAT
SHEET-TYPE WWR. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING.
6. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM
A615/A615M, GRADE 60. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS
OTHERWISE INDICATED. CONTINUOUS REINFORCING STEEL SHALL BE LAPPED WITH TYPE "B"
SPLICES IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 318.
7. MECHANICAL SPLICES MAY BE USED FOR CONTINUOUS REINFORCING. REINFORCING BARS
SHALL HAVE THEIR SPLICES STAGGERED A MINIMUM OF 30 INCHES.
8. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO
CASE SHALL REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND: 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER: 2"
9. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90-DEGREE
HOOK UNLESS OTHERWISE NOTED. STIRRUP, TIE AND 180-DEGREE HOOKS AND 90-DEGREE
HOOKS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318.
10. UON PROVIDE MIN 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SLABS ON
GRADE ABUT VERTICAL SURFACES.
11. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL SLAB PENETRATIONS FROM ALL
DISCIPLINES PRIOR TO PLACING CONCRETE. PENETRATIONS NOT SHOWN ON STRUCTURAL
DRAWINGS SHALL BE SHOWN ON SHOP DRAWINGS. ALL EMBEDDED ITEMS SHALL BE
PROPERLY PLACED, ACCURATELY POSITIONED, AND MAINTAINED SECURELY IN PLACE PRIOR
TO AND DURING CONCRETE PLACEMENT.
12. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, TIEBACKS, RECESSES AND OTHER
EMBEDDED ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO
FACILITATE PLACEMENT OF EMBEDDED ITEMS.
13. NO CONCRETE SHALL BE PLACED UNTIL THE CONTRACTING OFFICER OR THE
CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE HAS INSPECTED ALL EMBEDDED
WORK, INCLUDING REINFORCEMENT.
14. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" UON
15. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS
EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND
ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL.
16. USE OF FIBER REINFORCED CONCRETE SYSTEMS WITHOUT APPROVAL IS PROHIBITED.
17. CONCRETE SLABS MAY BE PLACED USING STRIP PLACEMENT METHOD.
CONCRETE CONSTRUCTION NOTES
1. GEOTECHNICAL INFORMATION - REFER TO GEOTECHNICAL ENGINEERING REPORT TITLED
"LIMITED SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION
MARSOC SUPPORT FACILITIES FORT A.P. HILL, VIRGINIA", DATED DECEMBER 2017, PREPARED
BY THE U.S. ARMY CORPS OF ENGINEERS GEO-ENVIRONMENTAL SECTION.
2. REMOVAL AND BACKFILLING OPERATIONS OF UNCONTROLLED FILL AND OVER EXCAVATION
SHALL BE PERFORMED UNDER THE SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED
IN THE COMMONWEALTH OF VIRGINIA. THE PROFESSIONAL ENGINEER OVERSEEING THESE
OPERATIONS SHALL CERTIFY TO THE GOVERNMENT THAT ALL UNCONTROLLED FILL HAS BEEN
REMOVED AND REPLACED WITH PROPERLY COMPACTED STRUCTURAL FILL MEETING THE
PROJECT REQUIREMENTS.
3. REFER TO GEOTECHNICAL ENGINEERING REPORT TITLED "LIMITED SUBSURFACE
EXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION MARSOC SUPPORT FACILITIES
FORT A.P. HILL, VIRGINIA", DATED DECEMBER 2017, PREPARED BY THE U.S. ARMY CORPS OF
ENGINEERS GEO-ENVIRONMENTAL SECTION FOR NON-EXPANSIVE FILL, SELECT FILL, AND
SELECT CLAY FILL MATERIAL DEFINITIONS AND REQUIREMENTS, AND FOR COMPLETE FILL AND
SUB-GRADE PREPARATION MINIMUM REQUIREMENTS.
4. THE FOUNDATIONS CONSIST OF A CONCRETE SLAB ON GRADE WITH THICKENED
PERIMETER EDGES AND AREAS AS REQUIRED.
5. DESIGN ASSUMPTIONS:
A. NET ALLOWABLE SOIL PRESSURE: 2,000 PSF
B. MINIMUM MODULUS OF SUBGRADE REACTION (k): 225 PCI
6. DO NOT CONSTRUCT FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED
WITH UNDERGROUND UTILITIES AND STRUCTURES.
7. COORDINATE AND VERIFY ALL FOOTING LOCATIONS WITH OTHER DISCIPLINE DRAWINGS
INCLUDING CIVIL, PLUMBING, AND ELECTRICAL DRAWINGS.
8. ALL FOUNDATIONS AND SLABS ON GRADE SHALL BEAR ON A VAPOR BARRIER, A LAYER OF
POROUS FILL AND PREPARED SUB-GRADE - SEE GEOTECHNICAL ENGINEERING REPORT
TITLED "LIMITED SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION
MARSOC SUPPORT FACILITIES FORT A.P. HILL, VIRGINIA", DATED DECEMBER 2017, PREPARED
BY THE U.S. ARMY CORPS OF ENGINEERS GEO-ENVIRONMENTAL SECTION AND DETAIL
A1/S-502.
GEOTECHNICAL NOTES
1. METAL BUILDING SYSTEM SHALL BE IN ACCORDANCE WITH MBMA BUILDING SYSTEM
MANUAL. PROVIDE SINGLE-SPAN RIGID FRAMES WITH TAPERED BEAMS AS REQUIRED.
COLUMN BASES ARE TO BE DESIGNED AS "PINNED" COLUMN ENDS, TRANSFERRING NO
MOMENTS TO THE FOUNDATION. COLUMNS ARE NOT TO BE TAPERED - USE STANDARD AISC
SHAPES.
2. MANUFACTURER IS TO INCLUDE COLLATERAL DESIGN LOADS FROM ALL DISCIPLINES.
MANUFACTURER IS TO VERIFY COLLATERAL LOADS, COORDINATE AND DESIGN FRAMING
SYSTEM AS REQUIRED FOR ALL SUSPENDED OR SUPPORTED LOADS WITH OTHER DISCIPLINES
(INCLUDING BUT NOT LIMITED TO SUSPENDED OR WALL MOUNTED EQUIPMENT, DUCTS,
CONDUIT, LIGHTING, ETC.) A MINIMUM COLLATERAL LOAD OF 10 PSF IS TO BE INCLUDED FOR
SPRINKLER SYSTEM IN SPRINKLERED BUILDINGS.
3. PROVIDE MINIMUM CLEARANCE UNDER RIGID FRAMES. SEE ARCHITECTURAL DRAWINGS.
4. PROVIDE FRAMING MADE OF STRUCTURAL STEEL SHAPES AROUND LARGE OVERHEAD
DOORS AS SHOWN - SEE ARCHITECTURAL DRAWINGS. COLD-FORMED CHANNEL JAMBS ARE
NOT ALLOWED. DESIGN THE FRAMING FOR ALL EFFECTS OF WIND AND DEAD LOADS
(INCLUDING CATENARY FORCES).
5. PROVIDE CHANNEL-TYPE PURLIN BRACING AS REQD AT INTERVALS NOT EXCEEDING 1/4
SPAN. PROVIDE ANTIROLL CLIPS AT ALL PURLIN BEARING POINTS.
6. LIMIT LATERAL BARE-FRAME DRIFT UNDER ANY DESIGN LOAD COMBINATION TO H/600 (AT
TOP OF MASONRY) FOR BUILDINGS WITH MASONRY EXTERIOR FINISHES, INTERIOR PARTITIONS
OR FINISHES ATTACHED TO FRAME (H/400 FOR OTHER CASES). COMPUTE DRIFT USING
DESIGN WIND LOADING WITH 50-YEAR MEAN RECURRENCE INTERVAL.
7. LIMIT THE MAXIMUM COMBINED VERTICAL DEFLECTION OF PURLINS AND FRAMES TO L/240
UNDER DESIGN SNOW OR ROOF LIVE LOAD.
8. LIMIT THE MAXIMUM HORIZONTAL DEFLECTION OF STEEL STUDS SUPPORTING MASONRY
EXTERIOR FINISH TO L/600 UNDER DESIGN WIND LOADING IN ACCORDANCE WITH MBMA
SYSTEMS MANUAL. LIMIT THE MAXIMUM HORIZONTAL DEFLECTION OF STEEL STUDS WITH
DRYWALL FINISH TO L/400 UNDER DESIGN WIND LOADING IN ACCORDANCE WITH MBMA
SYSTEMS MANUAL.
9. PERMANENT BUILDING BRACING MAY BE INSUFFICIENT DURING ERECTION. MANUFACTURER
IS TO DESIGN AND PROVIDE TEMPORARY LATERAL BRACING TO BE USED DURING
CONSTRUCTION UNTIL PERMANENT BRACING IS IN PLACE AS REQUIRED.
10. COLUMN AND BASE PLATE SIZES SHALL ALLOW FOR MINIMUM ANCHOR BOLT EDGE
DISTANCE OF 7 INCHES TO ANY VERTICAL EDGE OF CONCRETE. BASE PLATES SHALL BE
DESIGNED TO FIT ON SLAB SPACE PROVIDED.
11. PROVIDE BOTTOM-FLANGE ANGLE BRACING FOR PRIMARY FRAMES ON BOTH SIDES OF
MEMBER.
12. USE RODS, NOT CABLES, FOR WALL AND ROOF BRACING. PROVIDE BACKUP PLATES (MIN.
6" WIDE X 3/4" THICK) BEHIND ALL BRACE ROD CONNECTIONS TO FRAME WEBS. WELD PLATES
TO FRAME FLANGES.
13. CONTRACTOR IS TO PROVIDE COMPLETE SIGNED AND SEALED METAL BUILDING SYSTEM
DESIGN CALCULATIONS FOR EACH METAL BUILDING SYSTEM INCLUDING FACTORED AND
UNFACTORED COLUMN REACTIONS FOR EACH DESIGN LOAD CASE WITH THE CRITICAL
COLUMN REACTIONS AND BUILDING DRIFT NOTED.
METAL BUILDING SYSTEM NOTES
1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL
BE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND THE AISC "CODE OF STANDARD PRACTICE FOR BUILDINGS AND BRIDGES".
2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE
LISTED AISC SPECIFICATION AND THE FOLLOWING:
A. SQUARE AND RECTANGULAR HSS ASTM A500, GRADE B, Fy = 46 KSI B. ROUND HSS ASTM A500, GRADE B, Fy = 42 KSI
C. WIDE-FLANGE SHAPES AND TEES ASTM A992
D. CHANNELS AND S-SHAPES ASTM A36/A36M
E. PLATES AND ANGLES ASTM A36/A36M
F. HIGH STRENGTH BOLTS ASTM 325
G. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
H. THREADED ROD ASTM A36/A36M
3. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS NOTED OTHERWISE. CURRENT AWS
CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE CONTRACTING
OFFICER'S REPRESENTATIVE.
4. UNLESS OTHERWISE NOTED MINIMUM WELD SIZE TO BE 1/4" FILLET WELD
5. CONFORM DIMENSIONAL TOLERANCES FOR WELDED CONSTRUCTION, DETAILS OF WELDS, AND
QUALITY OF WELDS WITH THE APPLICABLE REQUIREMENTS OF AWS D1.1 AND THE CONTRACT
DRAWINGS. CONTRACTOR SHALL VISUALLY INSPECT 100 PERCENT OF WELDS. IN ADDITION, A
MINIMUM OF 20 PERCENT OF WELDS SHALL BE RANDOMLY SELECTED AND TESTED BY LIQUID
PENETRANT. ALSO, 100 PERCENT OF FULL MOMENT WELDS ARE TO BE TESTED BY ULTRASONIC
METHODS.
6. ALL BOLTED CONNECTIONS, UON, SHALL USE HIGH STRENGTH BOLTS WITH HARDENED CARBON
STEEL WASHERS AS REQUIRED FOR THE CONNECTION LOADS.
7. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE PERMITTED.
BOLT HOLES SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
8. ALL FIELD BOLTED SHEAR CONNECTIONS SHALL BE FULLY TENSIONED CONNECTIONS, THREADS
INCLUDED IN THE SHEAR PLANE.
9. CONNECTION DESIGN IS DELEGATED TO THE CONTRACTOR. THE FABRICATOR SHALL SUBMIT
DETAILS AND CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER IN THE STATE OF VIRGINIA TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO DOING ANY WORK OR ORDERING MATERIALS.
10. CONNECTIONS FOR AXIAL, SHEAR AND BENDING FORCES SHALL BE DESIGNED FOR THE
FACTORED CAPACITY OF THE CONNECTED MEMBER.
11. THE MINIMUM BOLT DIAMETER SHALL BE 3/4" UNLESS OTHERWISE NOTED.
12. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS
SPECIFICALLY PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND
AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
13. PAINT ALL STEEL BELOW GRADE WITH TWO COATS OF COAL TAR EPOXY IN ACCORDANCE WITH
SSPC PAINT 16.
14. CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING MISCELLANEOUS STEEL
REQUIRED TO SUPPORT DRAINS, FAN CURBS, OVERFLOW DRAINS, ACCESS HATCHES, ACCESS
PANELS, ETC. COORDINATE WITH ALL DISCIPLINE DRAWINGS.
15. POST INSTALLED ANCHOR BOLTS SHALL BE ASTM A193, GRADE B7 OR APPROVED EQUAL.
ANCHORS MAY BE UNDERCUT OR EPOXY ADHESIVE TYPE. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. ANCHORS SHALL WITHSTAND DESIGN LOADS INDICATED ON THE PLANS.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S ANALYSIS AND DESIGN DATA SHOWING THAT THE
ANCHOR BOLT SYSTEMS MEET THE ANCHOR FORCE REQUIREMENTS IN ACCORDANCE WITH
APPENDIX D OF ACI 318.
HOT ROLLED STEEL CONSTRUCTION NOTES
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:5
AM
S-001
ST
R
U C
T U R
AL
N
O
TE
S
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
L.
M
U
LÉ
L.
M
U
LÉ
L M
U
LÉ
C . S
AN
D
ER
S
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 17 OF 51
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ABBREVIATION DESCRIPTION
AB ANCHOR BOLT
AFF ABOVE FINISHED FLOOR
ANR ANCHOR
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
ATFP ANTI-TERRORISM AND FORCE
PROTECTION
BC BOTTOM CHORD
BM BEAM
BOC BOTTOM OF CONCRETE
BOS BOTTOM OF STEEL
BOTT BOTTOM
BRG BEARING
BP BEARING OR BASE PLATE
CFMF COLD-FORMED METAL FRAMING
CFS COLD-FORMED STEEL
CJ SLAB CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
DE DECK EDGE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DWG/DWGS DRAWING/DRAWINGS
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
ELEV ELEVATION
EOS EDGE OF SLAB
EQ EQUAL
ES EQUALLY SPACED
EW EACH WAY
EXT EXTENSION
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FOB FACE OF BRICK
FS FOOTING STEP
FTG FOOTING
GA GAGE
HORIZ HORIZONTAL
HS HIGH STRENGTH
HSS HOLLOW STRUCTURAL SHAPE
JBE JOIST BEARING ELEVATION
JS JOIST SUBSTITUTE
JST JOIST
KB KNUCKLED BEAM
KIPS (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO. NUMBER
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
SCHED SCHEDULE
SDS SELF DRILLING SCREW
SF STEPPED FOOTING
SHT SHEET
SIM SIMILAR
SJ SLAB CONTROL JOINT
SPA SPACES/SPACED
STD STANDARD
T&B TOP AND BOTTOM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF STEEL
TS THICKENED SLAB
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
USACE UNITED STATES ARMY CORPS OF
ENGINEERS
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
WT WEIGHT
STRUCTURAL ABBREVIATIONS
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE LATEST
EDITION OF THE FOLLOWING CODES AND SPECIFICATIONS UON:
A. INTERNATIONAL BUILDING CODE (IBC)
B. ASCE 7, MINIMUM DESIGN LOADS FOR BUILDING AND
OTHER STRUCTURES
C. AISC "SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS"
D. ACI 318, BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE
E. UFC 4-010-01 DoD MINIMUM ANTITERRORISM
STANDARDS FOR BUILDINGS
F. UFC 3-310-04 SEISMIC DESIGN OF BUILDINGS
G. UFC 3-301-01 STRUCTURAL ENGINEERING
2. MINIMUM DESIGN LOAD CRITERIA:
A. RISK CATEGORY II
B. DEAD LOADS:
COLLATERAL (MINIMUM) 10 PSF
C. LIVE LOADS:
ROOF 20 PSF
FLOOR SLAB 125 PSF
D. SNOW LOAD:
GROUND SNOW LOAD, Pg 25 PSF
SNOW LOAD IMPORTANCE FACTOR, I 1.2
SNOW EXPOSURE FACTOR, Ce 1.0 THERMAL FACTOR, Ct 1.1
RAIN ON SNOW LOAD 5 PSF
E. WIND LOADS:
WIND IMPORTANCE FACTOR, I 1.0
BASIC WIND SPEED, V 115 MPH
WIND EXPOSURE CATEGORY C
INTERNAL PRESSURE COEFFICIENTS, GCpi +/-0.18
F. SEISMIC LOADS:
SEISMIC IMPORTANCE FACTOR, I 1.5
SPECTRAL RESPONSE ACCELERATION, Ss 0.15g SPECTRAL RESPONSE ACCELERATION, S1 0.06g
SITE CLASS D
3. WIND LOAD CRITERIA SHALL BE USED TO CALCULATE WIND
LOAD PER ASCE FOR ALL REQUIRED DESIGN LOAD
COMBINATIONS.
4. SEISMIC LOAD CRITERIA SHALL BE USED TO CALCULATE WIND
LOAD PER ASCE FOR ALL REQUIRED DESIGN LOAD
COMBINATIONS.
5. GROUND SNOW LOAD SHALL BE CONVERTED TO ROOF SNOW
LOAD PER ASCE FOR ALL REQUIRED DESIGN LOAD
COMBINATIONS.
6. DESIGN LOAD COMBINATIONS SHALL INCLUDE PATTERN OR
PARTIAL LOADING SNOW LOAD CONDITIONS IN ADDITION TO
UNIFORM LOAD CONDITION .
7. COLLATERAL LOADS SHALL BE INCLUDED IN DESIGN LOAD
COMBINATIONS TO PROVIDE ALLOWANCE FOR SUPERIMPOSED
DEAD LOADS SUCH AS FIRE SUPPRESSION SYSTEM PIPING,
HVAC, ETC.
DESIGN LOAD NOTES
SLOPE SLOPE DIRECTION
DECK SPAN
INDICATES ELEVATION
REFERENCED TO FINISH
FIRST FLOOR
GRID REFERENCE LINE
POSSIBLE CONSTRUCTION
JOINT LOCATION AT
CONTROL JOINT
CONTROL JOINT LOCATION
STEEL
BRICK
CONCRETE MASONRY
UNIT
CONCRETE
GROUT
CAPILLARY WATER
BARRIER
EARTH FILL
STRUCTURAL LEGEND
SYMBOL DESCRIPTION
[+/-X'-X"]
1. SEE FOUNDATION PLANS FOR CONCRETE SLAB THICKNESS.
2. SLABS WITH THICKNESS UP TO 6" SHALL BE TREATED AS SLAB-ON-GRADE. SEE DETAILS ON
SHEET S-502.
3. SLABS SHALL BE DOWELED AT ALL CONSTRUCTION AND CONTROL JOINT LOCATIONS. SEE
DETAILS ON SHEET S-502.
4. REFERENCE SPECIFICATIONS FOR FINISH TOLERANCE CRITERIA.
5. THE CONTRACTOR SHALL PLACE CONTROL AND CONSTRUCTION JOINTS WITHIN THE SLAB AS
INDICATED BY THE FOUNDATION PLAN.
6. BULKHEADS AT CONSTRUCTION JOINTS SHALL REMAIN IN PLACE A MINIMUM OF THREE DAYS.
7. CURING BLANKETS, MOIST CURING TENTS, ETC. SHALL BE MAINTAINED FOR A MINIMUM OF
SEVEN DAYS OR AS INDICATED WITHIN THE PROJECT SPECIFICATION, WHICHEVER IS MORE
STRINGENT. THIS DOES NOT PREVENT THE CONTRACTOR FROM PLACING NEW CONCRETE SLAB
STRIPS BETWEEN SLAB STRIPS CURRENTLY CURING.
8. THE CONTRACTOR SHALL REFERENCE DETAIL A1/S-502 FOR SLAB-ON-GRADE PLACEMENT.
9. ALL CONTROL JOINTS LOCATED IN SLABS SHALL BE SAW CUT AS REQUIRED WITHIN 8 HOURS
OF CONCRETE PLACEMENT.
10. REFERENCE FOUNDATION NOTES IN COORDINATION WITH DETAILS FOR UNDER SLAB
TREATMENT.
CONCRETE CONTROL AND CONSTRUCTION JOINT PLACEMENT
NOTES
THE BUILDING FOUNDATIONS SHOWN HAVE BEEN DESIGNED FOR THE LOADS INDICATED
ON SHEET S-002. THE MANUFACTURER SHALL VERIFY THE ADEQUACY OF THE
FOUNDATIONS PER THE DESIGN LOAD NOTES AND DESIGN CRITERIA ON SHEET S-002. IF
THE MANUFACTURER GENERATED BUILDING DESIGN LOADS RESULT IN FOUNDATION
LOADS DIFFERING FROM WHAT IS SHOWN, THE CONTRACTOR SHALL REDESIGN THE
BUILDING FOUNDATION. CONTRACTOR IS TO PROVIDE COMPLETE SIGNED AND SEALED
FOUNDATION DESIGN CALCULATIONS INCLUDING FACTORED AND UNFACTORED COLUMN
REACTIONS FOR EACH DESIGN LOAD CASE WITH THE CRITICAL COLUMN REACTIONS
NOTED FOR USACE REVIEW AND APPROVAL.
PEB BUILDING FOUNDATION NOTES
FOOTING TYPE
F5.0
F4.6
WIDTH
5'-8"
4'-6"
5'-0"
4'-6"
LENGTH THICKNESS
3'-0"
3'-0"
REINFORCEMENT
7 - #8 EW ES BOTT
6 - #8 EW ES BOTT
FOOTING SCHEDULE
PERPENDICULAR
TO WALL [KIPS]
R
EA
C
TI
O N
PA
R
AL
LE
L
TO
W
AL
L
VERTICAL
[KIPS]
RIGID FRAME
PARALLEL TO
WALL [KIPS]
19.8 5.4 41.7
2.0 4.0 -5.0 MAXIMUM LOADS FOR UPLIFT
CONDITION ACTING CONCURRENTLY
MAXIMUM LOADS FOR VERTICAL DOWNWARD
CONDITION ACTING CONCURRENTLY
COMMENTS
UNFACTORED SERVICE DESIGN FOUNDATION REACTIONS
RIGID FRAME
RIGID FRAME
RIGID FRAME
RIGID FRAME
REACTION
PERPENDICULAR
TO WALL
BR
AC
ED
FR
AM
E
BR
AC
ED
FR
AM
E
1.COLD-FORMED STEEL (CFS) DESIGN AND CONSTRUCTION SHALL BE IN
ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN IRON AND STEEL
INSTITUTE (AISI) "COLD-FORMED STEEL DESIGN MANUAL", INCLUDING THE TRUSS
DESIGN MANUAL AND THE NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF
COLD FORMED STEEL STRUCTURAL MEMBERS.
2. COLD-FORMED STEEL WALL FRAMING AND CONNECTION DESIGN SHALL BE
DELEGATED TO THE CONTRACTOR EXCEPT FOR THE CFS SUPPORTING THE
MECHANICAL MEZZANINES IN THE CANDIDATE ISOLATION CLASSROOM AND
ADMINISTRATION AND OPERATIONS BUILDING . SUBMIT CALCULATIONS ALONG
WITH THE SHOP DRAWINGS. DESIGN, INCLUDING DETERMINATION OF ALL
APPLICABLE LOADS, SHALL BE BASED ON REQUIREMENTS OF THE LATEST
EDITIONS OF ASCE 7, UFC 4-010-01, "DOD MINIMUM ANTI-TERRORISM STANDARDS
FOR BUILDINGS" AND UFC 4-023-03 "DESIGN OF BUILDINGS TO RESIST
PROGRESSIVE COLLAPSE". SEALED CALCULATIONS AND DRAWINGS SHALL BE
SUBMITTED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE
OF VIRGINIA AND APPROVED PRIOR TO ORDERING MATERIALS.
3. ALL MATERIAL MUST BE 18 GAGE OR GREATER IN THICKNESS AND SHALL HAVE
A MINIMUM YIELD STRENGTH OF Fy = 50 KSI.
4. MEMBER DESIGNATIONS SHALL BE AS FOLLOWS: A B C - D
A = WEB DEPTH (DECIMAL INCHES) X 100
B = SECTION TYPE
C = FLANGE WIDTH (DECIMAL INCHES) X 100
D = BASE METAL THICKNESS (MILS)
SECTION TYPES (B):
S = STUD AND JOIST SECTION WITH FLANGE STIFFENING
RETURN LIPS
T = TRACK SECTIONS (NO STIFFENING RETURN LIPS)
U = CHANNEL AND CHANNEL STUDS (NO STIFFENING
RETURN LIPS)
F = FURRING CHANNEL
EXAMPLES:
MEMBER WEB SECTION FLANGE BASE METAL
DESIGNATION DEPTH TYPE WIDTH THICKNESS
362S162-33 3-5/8" S 1-5/8" 33 MILS
400T125-68 4" T 1-1/4" 68 MILS
MINIMUM CONNECTION REQUIREMENTS FOR COLD-FORMED WALL MEMBERS
ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
CONDITION CONNECTION
STUD TO TRACK (2) #10-16 SELF-DRILLING
SCREWS WITH STUD
SECURELY SEATED INTO
TRACK
TRACK TO STEEL BEAM 1/8" WELD EACH SIDE, 2" LONG
SPACED @ 32" OC
EXTERIOR STUD TRACK AISI 1021 3/16" DIAMETER CONCRETE
TO CONCRETE SLAB OR SCREWS SPACED @ 2'-8" THROUGH
FOUNDATION TRACK. PROVIDE 1 1/2" MINIMUM
FOUNDATION EMBEDMENT. MINIMUM
SPACING = 4".
CONCRETE EDGE DISTANCE = 3"
STUD TO STUD (2) #10 SDS @ 1'-4" OC
5. DEFLECTION OF WALL STUD SPANS FOR LATERAL LOADS SHALL NOT EXCEED A
LIMIT OF L/600. MANUFACTURER MAY PROVIDE HOT ROLLED STEEL STUD
STIFFENER BETWEEN COLUMNS AS REQUIRED - SEE ARCHITECTURAL DRAWINGS
6. ALL CONNECTION SCREWS SHALL BE ZINC COATED.
7. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING
CODE - SHEET STEEL."
8. CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AND
GUYING OF COLD-FORMED METAL FRAMING AS REQUIRED TO PROVIDE FOR THE
SAFETY OF THE STRUCTURE AND WORK PERSONNEL. BRACING SHALL REMAIN
UNTIL NO LONGER REQUIRED FOR SAFE SUPPORT OF FRAMING.
9. FIELD MODIFICATIONS OF COLD-FORMED STEEL SYSTEMS SHALL NOT BE
ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER OF RECORD.
10. MAINTAIN 3/4" MINIMUM DISTANCE BETWEEN CENTERS OF CONNECTION
SCREWS AND 3/4" MINIMUM DISTANCE FROM THE CENTER OF SCREW TO EDGE OF
CONNECTED PART. INSTALL FASTENERS FROM THINNER THROUGH THICKER
MATERIAL.
11. MECHANICAL BRIDGING SHALL BE PLACED AT A MINIMUM OF THIRD POINTS
ALONG STUD SPAN FOR ALL LOAD BEARING, SHEAR AND EXTERIOR WALLS LESS
THAN 15 FEET TALL, BUT NOT GREATER THAN 4'-0" OC. BRIDGING SHALL BE IN
PLACE PRIOR TO PLACING ANY LOADS ON THE STUD WALLS.
13. THE CONNECTION OF NONSTRUCTURAL COLD-FORMED STEEL FRAMING SHALL
BE PROVIDED WITH SLIP TYPE CONNECTION WHICH WILL ALLOW FOR DEFLECTION
OF THE BUILDING FRAME.
13. TYPICAL EXTERIOR WALL STUD SHALL BE 6" DEEP.
14 LOAD BEARING WALL FRAMING SHALL ALIGN WITH WALL FRAMING FROM THE
BUILDING STORY ABOVE.
COLD-FORMED STEEL FRAMING
CONSTRUCTION NOTES
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:5
AM
S-002
ST
R
U C
TU
R
AL
N
O
TE
S , L
EG
EN
D A
N D
AB
BR
EV
IA
T I O
N S
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
L.
M
U
LÉ
L.
M
U
LÉ
L M
U
LÉ
C . S
AN
D
ER
S
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 18 OF 51
M
AR
K D
ES
C
R
IP
TI
O
N D
A
B
C
SJ
SJ
SJ SJ
SJ
(C
J)
SJ
(C
J)
SJ
(C
J)
BRACED BAY
AS REQD
SIDE WALL RIGID FRAME
COLUMN AND BP AS
REQD, TYP ON GRID LINE
A & D
BRACED BAY
AS REQD
HAIRPIN - TYP
SJ
SJ
SJ
BOLLARD - TYP -
SEE ARCH DWGS
F5.0 F5.0 F5.0
F5.0 F5.0 F5.0
F5.0
F5.0
F5.0
F5.0
F4.6
F4.6
F4.6
F4.6
1'
5"
1' - 2"
1'
5"
1'
1'
2' - 3"
1' - 8"
1' - 8"
EDGE OF
CONCRETE
SLAB
EDGE OF
CONCRETE
SLAB
EDGE OF
CONCRETE
SLAB/FACE
OF CONCRETE
FOUNDATION
@ PORCH
EDGE OF
CONCRETE
SLAB/FACE OF
CONCRETE
FOUNDATION
@ PORCH
EDGE OF
CONCRETE
SLAB
EDGE OF
CONCRETE
SLAB
A3 S-501
C2 S-501
C1 S-501
C4 S-501
C2 S-501
C1 S-501
C1 S-501
A1 S-501
C2 S-502
SEE ARCHITECTURAL AND
CIVIL DRAWINGS FOR
ADDTIONAL INFORMATION
LINE OF THICKEND
SLAB - TYP
FACE OF CONCRETE
FOUNDATION - TYP
SEE C1/S501
8' - 4" 3' - 4"
TY
P
EQ
TY
P
EQ
TYP
S-502 C4
ST
O
O P
4'
6"
STOOP
6' - 0"
B2 S-501
CONCRETE STOOP -
SEE CIVIL
END WALL INTERMEDIATE
COLUMN AND BP AS REQD,
TYPICAL GRID LINE 1, 3 & 4
D1 S-501
C2 S-502
1/2" EXPANSION
JOINT WITH FILLER
4" DIA. CONDUIT THROUGH
SLAB COORDINATE
WITH TELECOM
6"
6"
1. TOP OF SLAB REFERENCE ELEVATION: [0' - 0"] ACTUAL TOP OF SLAB ELEVATION: +223.7' SEE CIVIL DRAWINGS.
2. TYPICAL INTERIOR SLAB THICKNESS 'T' = 6" - SEE A1/S-502.
3. TYPICAL EXTERIOR CONCRETE PADS AND STOOPS THICKNESSES 'T' = 6" - SEE B4/S-501
4. SEE A1/S-502 FOR TYPICAL SLAB CONSTRUCTION, CONTROL JOINT (SJ) AND CONSTRUCTION JOINT (CJ) DETAILS.
5. CONTRACTOR MAY PLACE SLAB CONTROL JOINTS (SJ) AT LOCATIONS INDICATED.
6. SLAB CONSTRUCTION JOINTS (CJ) SHOWN ARE PROPOSED LOCATIONS. CONTRACTOR MAY PLACE SLAB CONSTRUCTION JOINTS
AT PROPOSED LOCATIONS AS REQUIRED.
7. JOINT NOTED SJ (CJ) ARE SLAB CONTROL JOINTS THAT MAY BE CONSTRUCTION JOINTS . SEE A1/S-502.
8. FOR BEARING WALL INFORMATION SEE SHEET B1/S-501, A4/S-502 & B4/S-502.
9. RIGID FRAMES ARE LOCATED ON GRID LINES: 1, 2, 3 & 4.
10. "FX.X" INDICATES CONCRETE FOOTING. SEE FOOTING SCHEDULE ON SHEET S-002 AND DETAILS C2/S-501, C4/S-501 & A3/S-501.
11. ALL SJ(CJ) & SJ ARE TO LOCATED AS SHOWN AT COLUMN GRID LINES AND MIDPOINTS BETWEEN COLUMN GRID LINES IN EACH
DIRECTION.
STORAGE BUILDING FOUNDATION PLAN NOTES
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:5
AM
S-101
ST
O
R
AG
E
BU
IL
D
IN
G
FO
U N
D
AT
IO
N
P
LA
N
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
L.
M
U
LÉ
L.
M
U
LÉ
L M
U
LÉ
C . S
AN
D
ER
S
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 19 OF 51
SCALE: 3/16" = 1'-0"
STORAGE BUILDING - FOUNDATION PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
4' 8' 12' 16'
SCALE: 3/16" = 1' - 0"
0'
NO SCALE
NORTH
KEY PLAN
STORAGE BLDG
13 - #5 CONT
PERIMETER
FTG REINF
T & B
COMPACT SUBGRADE - TYP
CAPILLARY BARRIER
VAPOR BARRIER
WWF
FACE OF
CONCRETE
FOUNDATION -
SEE PLAN
GRID
x x x xxxx
MASONRY
VENEER -
SEE ARCH
EDGE OF CONCRETE
SLAB - SEE PLAN
CFS - SEE S-002
CONCRETE SLAB - SEE PLAN
AND
A1/S-502
#5 BENT BAR @ 24" OC
8" SEE
PLAN
8" 2'
-4
2'-0"
3' -0
0"
FINISH FLOOR
2"
CL OF COLUMN AND
FOOTING
FTG REINF -
SEE FOOTING
SCHEDULE
PERIMETER
FOOTING
BEYOND
x x x x xx
HAIR PIN - SEE PLAN & A2/S-502
SIDEWALL RIGID FRAME
COLUMN - SEE PLAN
PERIMETER
FTG REINF
-SEE C1/S-501
GRID
SEE DETAIL C1/S-501 FOR
ADDITIONAL INFORMATION
xxx x
SEE FOOTING SCHEDULE
EQ EQ
0"
FINISH FLOOR
PERIMETER
INSULATION
#5 BENT BAR @ 24" OC
PERIMETER
INSULATION CL OF COL AND FOOTING
FTG REINF -
SEE FOOTING
SCHEDULE
PERIMETER
FOUNDATION
BEYOND
x x x x xx
ENDWALL INTERMEDIATE COLUMN -
SEE PLAN
PERIMETER FTG
REINF -SEE C1/S-501
SEE DETAIL C2/S-501 FOR
ADDITIONAL INFORMATION
x xxx x
GRID
#5 BENT BAR @ 24" OC
EQEQ
SEE FOOTING SCHEDULE
3"1'-2"
0"
FINISH FLOOR
PERIMETER
INSULATION
x x x xxx x x x x x x x x x x x xx x
PERIMETER FOOTING REINF -
SEE C1/S-501
SLOPE SLAB 1/8" PER
FOOT FROM FACE OF
MASONRY VENEER
EDGE OF
SLAB/FACE OF
CONCRETE
FOUNDATION -
SEE PLAN
x x
CONCRETE
SLAB - SEE
PLAN AND
A1/S-502
GRID GRID
5" 2'-11"
SEE PLAN
0"
FINISH FLOOR
CFS - SEE S-002
MASONRY
VENEER -
SEE ARCH
VAPOR BARRIER
CAPILLARY BARRIER
COMPACT SUBGRADE - TYP
#5 BENT BAR @ 24" OC
1/2" EXPANSION JOINT
PERIMETER INSULATION
CL OF COLUMN
SLOPE SLAB 1/8" PER
FOOT FROM FACE OF
MASONRY VENEER
INTERMEDIATE COLUMN -
SEE PLAN
INTERMEDIATE COLUMN -
SEE PLAN
x x x x xx x xx xx x x x xx x xxxx x x
FTG REINF - SEE
FTG SCHEDULE
PERIMETER
FOUNDATION
BEYOND
PERIMETER
FTG REINF -
SEE C1/S-501
PERIMETER FTG
REINF -SEE C1/S-501
SEE DETAIL A1/S-501 FOR
ADDITIONAL INFORMATION
xx x
GRID GRID
1#5 BENT BAR @ 24" OC
3"
SEE FOOTING SCHEDULE
EQ + 8"EQ
SEE FOOTING SCHEDULE
EQEQ
0"
FINISH FLOOR
PERIMETER
FOUNDATION
BEYOND
1' - 3"
1' - 9"
1/2" EXPANSION JOINT
3 #5 STIRRUPS
AT 12" O.C. UNDER
COLUMNS (CENTER)
3 #5 STIRRUPS
AT 12" O.C. UNDER
COLUMNS (CENTER)
FTG REINF-
SEE
FOOTING
SCHEDULE
TOP OF SLAB
+0'-0" SLAB FF
MASONRY VENEER (BEYOND) -
SEE ARCH DWGS
EXPANSION MATERIAL -
TYP
CONC SLAB - SEE PLAN
TOP OF SLAB
-0'-1/2" SLAB FF
CONC STOOP
SLAB - SEE PLAN
& CIVIL DWGS
CFS (BEYOND) - SEE ARCH
DWGS
TOP OF SLAB
+0'-0" SLAB FF
EXPANSION MATERIAL -
TYP
CONC PORCH
SLAB - SEE PLAN
CONC STOOP
SLAB - SEE PLAN
& CIVIL DWGS
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:5
AM
S-501
SE
C
TI
O
N S
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
L.
M
U
LÉ
L.
M
U
LÉ
L M
U
LÉ
C . S
AN
D
ER
S
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 20 OF 51
SCALE: 3/4" = 1'-0"C1 TYPICAL PERIMETER FOOTING
S-101
SCALE: 3/4" = 1'-0"C2 TYPICAL COLUMN FOOTING @ GRID LINES A & D
S-101
SCALE: 3/4" = 1'-0"C4 TYPICAL INTERMEDIATE COLUMN FOOTING
S-101
SCALE: 3/4" = 1'-0"A1 SECTION THROUGH PORCH
S-101
SCALE: 3/4" = 1'-0"A3 SECTION @ PORCH AT INTERMEDIATE COLUMN
S-101
SCALE: 1 1/2" = 1'-0"B2 TYPICAL STOOP/BUILDING SLAB JOINT DETAIL
S-101
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
SCALE: 1 1/2" = 1'-0"D1 TYPICAL STOOP/PORCH SLAB JOINT DETAIL
S-101
PERIMETER
INSULATION
0"
MIN
TYP
TYP
1' - 0"
MIN
2' - 0"
TYP
1' - 0"
0"
MIN
TYP
MIN TYP
2' - 0"
GRID
GRID
EDGE OF CONCRETE SLAB - SEE PLAN
M
IN3"
EQ EQ
#6 REINF BAR
GRID
#6 REINF BAR
GRID
M
IN3"
MIN
3"
EDGE OF
CONCRETE
SLAB - SEE
PLAN
STEEL
COL & BP
ABOVE
STEEL
COL & BP
ABOVE
SLAB PENETRATION TO SUIT PIPE
REINF EF AROUND PENETRATION -
MATCH VERT REINF
4'-0" LONG #5 VERT REINF - MIN (2) BARS
EACH SIDE OF PENETRATION
4'-0" LONG #5 HORZ REINF - MIN (2) BARS
EACH SIDE OF PENETRATION
STOP REINF AT PENETRATION - TYP
CONCRETE SLAB - SEE PLAN
TYP
2" MIN
TYP
2" MIN
TYP
1' - 0"
TY
P
1'
0"
CONCRETE SLAB - SEE PLAN &
NOTES
MINIMUM 10 MIL VAPOR BARRIER
MINIMUM 6" CAPILLARY BARRIER
SUB-GRADE - SEE CIVIL DRAWINGS
WELDED WIRE REINFORCEMENT -
4x4-W4.0xW4.0
SE
E
PL
A N
T (S
LA
B
TH
IC
KN
ES
S)
C
LR2" TOP OF SLAB
SEE PLAN
CONCRETE SLAB - SEE PLAN & NOTES
WELDED WIRE REINF. STOP AT
CONSTRUCTION JOINT
SEE TYPICAL SLAB CONSTRUCTION DETAIL
FOR ADDITIONAL INFORMATION
SAW CUT JOINT AFTER ADJACENT
SLAB PLACEMENT. FILL WITH
JOINT SEALANT AS LATE AS POSSIBLE
T/
T/
SMOOTH #6 x 18" LONG DOWEL AT 12" OC
EXPANSION CAP (COAT BAR END
WITH GREASE
BREAK BOND WITH CURING COMPOUND BEFORE
ADJACENT SLAB IS PLACED
TOP OF SLAB
SEE PLAN
TYPICAL SLAB CONSTRUCTION
TYPICAL SLAB CONSTRUCTION JOINT (CJ)
CONCRETE SLAB - SEE PLAN & NOTES
WELDED WIRE REINF. CUT
ALTERNATE WIRES AT JOINT
T/
1/4" WIDE SAW JOINT
CONTROL JOINTS TO BE PLACED
WITHIN 10FT - 15 FT SPACING, UON
TOP OF SLAB
SEE PLAN
SEE TYPICAL SLAB
CONSTRUCTION DETAIL
FOR ADDITIONAL INFORMATION
TYPICAL SLAB CONTROL JOINT (SJ)
TYPICAL CONCRETE SLAB ON GRADE NOTES
1. THIS DETAIL SHALL APPLY ONLY FOR SLAB ON GRADE.
2. 'T' DENOTES SLAB THICKNESS - SEE FOUNDATION PLANS.
3. SLABS WITH THICKNESSES 6" OR LESS SHALL BE TREATED AS SLAB ON GRADE.
4. SEE PLAN FOR LOCATION OF SLAB ON GRADE CONSTRUCTION JOINTS (CJ). CAST SMOOTH
DOWELS INTO FIRST POUR WHERE CONSTRUCTION JOINTS WILL BE CREATED BY CONCRETE
SEQUENCING PLACEMENT SEQUENCING.
5. SEE PLAN FOR LOCATION OF SLAB ON GRADE CONTROL JOINTS (SJ). LOCATIONS INDICATED
ON PLAN ARE SCHEMATIC AND PRESENTED AS A GUIDELINE.
6. SAW CUT CONTROL JOINTS (SJ) TO DEPTH INDICATED WITHIN 8 HOURS AFTER SLAB PLACEMENT.
FILL WITH JOINT SEALANT AS LATE AS POSSIBLE.
x x x x x x x
PERIMETER FOOTING REINF - SEE
C1/S-501
EDGE OF
SLAB/FACE OF
CONCRETE
FOUNDATION -
SEE PLAN
COMPACT
SUBGRADE - TYP
CAPILLARY
BARRIER
VAPOR
BARRIER
x
GRID
SEE PLAN
0"
FINISH FLOOR
TYP #5 REBAR T & B
AT RE-ENTRANT
CORNERS - EACH
SIDE OF OPENING
EDGE OF SLAB
FACE OF CONCRETE
FOUNDATION - SEE
DETAIL C1/S-501
CONCRETE SLAB-ON-
GRADE - SEE PLAN
TYP #5 SPACED AT 8"
OC
MAX @ OPENING
EDGE OF SLABEDGE OF
SLAB
2"CLRTYP
1'-0"
TYP
3'- 0"T
YP
4' -0
"T
YP
8"
TYP
SLAB WIDTH @ OPENING - SEE PLAN
D4 S-502
C1 S-501
PERIMETER FOOTING
REINF - SEE C1/S-501
EDGE OF CONCRETE
SLAB/FACE OF CONCRETE
FOUNDATION - SEE PLAN
GRID
x x x xxxxx
SEE DETAIL C1/S-501 FOR
ADDITIONAL INFORMATION
MASONRY AND FOOTING
STEP BEYOND - SEE
DETAIL C1/S-501
REINF SEE DETAIL
C4/S-501 1'-6" LONG #5 @ 24" OC
2' -0
0"
FINISH FLOOR
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:5
AM
S-502
SE
C
TI
O
N S
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
L.
M
U
LÉ
L.
M
U
LÉ
L M
U
LÉ
C . S
AN
D
ER
S
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 21 OF 51
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
SCALE: 1/2" = 1'-0"A2 HAIRPIN DETAILS
SCALE: 3/4" = 1'-0"D2 SLAB PENETRATION DETAIL
SCALE: 1 1/2" = 1'-0"A1 TYPICAL SLAB ON GRADE DETAILS
SCALE: 3/4" = 1'-0"C2 SECTION @ PORCH EDGE
S-101
SCALE: 1" = 1'-0"C4 TYPICAL DETAIL AT EXTERIOR OPENINGS - PLAN
S-101
SCALE: 3/4" = 1'-0"D4 TYPICAL PERIMETER FOOTING @ DOOR OPENING
S-502
@ AT
Ø DIAMETER
# NUMBER
AB ANCHOR BOLT
AC AIR CONDITIONING
ACC ACCESSIBLE
ACFRP FIBER REINFORCED PANELS
ACP ACOUSTICAL CEILING PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADH ADHESIVE
ADJ ADJUSTABLE
ADMIN ADMINISTRATION
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFC ABOVE FINISH CEILING
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISH SLAB
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANCH ANCHOR, ANCHORAGE
APC ARCHITECTURAL PRECAST
CONC.
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AVG AVERAGE
BCJ BRICK CONTROL JOINT
BD BOARD
BDRY BOUNDARY
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BRCG BRACING
BRG BEARING
BRS BACKER ROD & SEALANT
BSMT BASEMENT
BUR BUILT-UP ROOFING
CAB CABINET
CB CORNER BEAD
CEM CEMENT
CER CERAMIC
CF CEMENT FLOOR
CFLG COUNTERFLASHING
CFMF COLD-FORMED METAL
FRAMING
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLD CLOTHES DRYER
CLG CEILING
CLO CLOSET
CLR CLEAR
CMPST COMPOSITE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CSK COUNTERSUNK
CSWK CASEWORK
CT CERAMIC TILE
CTR CENTER
CU COPPER
D DEEP / DEPTH
D-B DESIGN-BUILD
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DETL DETAIL
DGTL DIGITAL
DIA DIAMETER
ARCHITECTURAL ABBREVIATIONS
DIAG DIAGONAL
DIAP DISPENSER
DIM DIMENSION
DIR DIRECTION
DIST DISTANCE
DIV DIVISION
DK DECK
DL DEAD LOAD
DN DOWN
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DF DRINKING FOUNTAIN
E EAST
EA EACH
EIFS EXTERIOR INSULATION
FINISHING SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
ENTR ENTRANCE
EOS EDGE OF SLAB
EPS EXPANDED POLYSYRENE
EPDM ETHYLENE PROPYLENE
DIENE MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
EXTRU EXTRUSION
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FCO FLOOR CLEANOUT
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FGL FIBER GLASS
FIN FINISH / FINISHED
FLASH FLASHING
FLR FLOOR
FLUOR FLUORESCENT
FM FACTORY MUTUAL
FND FEMININE NAPKIN DISPENSER
FNR FEMININE NAPKIN
RECEPTACLE
FO FINISHED OPENING / FACE OF
FOB FACE OF BRICK
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOW FACE OF WALL
FRG FIBER REINFORCED GYPSUM
FRP FIBERGLASS REINFORCED
PLASTIC
FRT FIRE RETARDANT
FRTW FIRE RETARDANT TREATED
WOOD
FRMG FRAMING
FT FOOT / FEET
FTG FOOTING
FURG FURRING
FWC FABRIC WALL COVERING
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GD GUARD
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GFRC GLASS FIBER REINFORCED
CONCRETE
GFRG GLASS FIBER REINFORCED
GYPSUM
GL GLASS
GR GRADE
GT GROUT
GYP GYPSUM
GWB GYPSUM WALL BOARD
HB HOSE BIB
HC HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HD HAND
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR FILTER
HK HOOK
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HNG HUNG
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING VENTILATION & AIR
CONDITIONING
IBC INTERNATIONAL BUILDING
CODE
ID INSIDE DIMENSION
ILO IN LIEU OF
IN INCH
INCAND INCANDESCENT
INFO INFORMATION
INSUL INSULATE
INT INTERIOR
IRREG IRREGULAR
JAN JANITOR
JS JANITOR'S SINK
JT JOINT
KO KNOCK OUT
KPL KICK PLATE
L ANGLE/LENGTH/LONG
LA LANDSCAPE ARCHITECT
LAM LAMINATE
LAV LAVATORY
LB POUND
LD LOAD
LDG LANDING
LF LINEAR FOOT (FEET)
LIB LIBRARY
LKR LOCKER
LL LIVE LOAD
LOC LOCATION
LMST LIMESTONE
LT LIGHT
LVR LOUVER MACH MACHINE
MANUF MANUFACTURER
MATL MATERIAL
MAX MAXIMUM
MB MOISTURE BARRIER
MC MEDICINE CABINET
MDF MEDIUM DENSITY FIBER
BOARD
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURER
MGT MANAGEMENT
MH MANHOLE
MID MIDDLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY (MODIFIED)
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MWP MEMBRANE
WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAT NATURAL
NFPA NATIONAL FLRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
NW NORTHWEST
OA OVERALL
OC ON CENTER
OD OUTSIDE DIMENSION
OH OPPOSITE HAND
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OPNG OPENING
OPP OPPOSITE
OPH OPPOSITE HAND
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
OWSJ OPEN WEB STEEL JOIST
PA PUBLIC ADDRESS
PAT PATTERN
PB PULL BOX
PERF PERFORATED
PH PHASE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PNT PAINT (PAINTED)
POL POLISHED
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PSF POUND PER SQUARE FOOT
PSI POUND PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE
PWD PLYWOOD
QUAL QUALITY
QTY QUANITY
QT QUARRY TILE
R RADIUS
RB RESILIENT BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFERENCE
REC RECESSED
REF REFRIGERATOR
REINF REINFORCE / REINFORCING
REQ REQUIRE (REQUIRED)
REV REVISION
RF ROOF
RFR REFRIGERATOR
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RHR RIGHT HAND REVERSE
RL RAIN LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RTF RUBBER TILE FLOOR
RTU ROOF TOP UNIT
RWL RAIN WATER LEADER
S SOUTH
SATC SUSPENDED ACOUSTICAL
TILE CEILING
SAFB SOUND ATTENUATION FIRE
BLANKETS
SB SPLASH BLOCK
SC SOLID CORE
SCD SEAT COVER DISPENSER
SCP SCUPPERSD SOAP
DISPENSER
SD SMOKE DETECTOR
SE SOUTHEAST
SECT SECTION
SED SEE ELECT DRAWINGS
SF SQUARE FOOT
SGL SINGLE
SHT SHEET
SHTHG SHEATHING
SHWR SHOWER
SIM SIMILAR
SM SHEET METAL
SMD SEE MECH DRAWINGS
SKLT SKYLIGHT
SLNT SEALANT
SPECS SPECIFICATIONS
SPD SEE PLUMBING DRAWINGS
SQ SQUARE
SS SERVICE SINK / STAINLESS
STEEL
SSM STANDING SEAM METAL
SSMR STANDING SEAM METAL
ROOF
SST STAINLESS STEEL
ST STREET
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPEND
SYS SYSTEM
SW SOUTHWEST
T TREAD
T&G TONGUE AND GROOVE
T&B TOP & BOTTOM
TC TERRA COTTA
TCA TILE COUNCIL OF AMERICA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
THK THICKNESS
THR THRESHOLD
TKBD TACKBOARD
TMPD TEMPERED
TOC TOP OF CURB
TOF TOP OF FOOTING
TOPA TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOILET PARTITION
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TPO THERMOPLASTIC
POLYOLEFIN
TRANS TRANSOM
TRTD TREATED
TS TUBE STEEL
TV TELEVISION
TYP TYPICAL
UC UNDERCUT
UL UNDERWRITER'S
LABORATORY
UNFIN UNFINISHED
UON UNLESS OTHERWISE NOTED
UR URINAL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VENT VENTILATOR
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN THE FIELD
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WIDTH / WEST
W/ WITH
W/O WITHOUT
W/W WALL TO WALL
WBL WOOD BLOCKING
WC WATER CLOSET /
WALLCOVERING
WCHR WATER CHILLER
WCL WATER COOLER
WD WOOD
WDW WINDOW
WH WATER HEATER
WL WALL
WO WINDOW OPENING
WP WEATHERPROOF / WORK
POINT
WR WATER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
x BY
XPS EXTRUDED POLYSTYRENE
LEGEND
NAME
AREA
WINDOW TYPE
COLUMN LINE
DESIGNATOR
DOOR NUMBER
REVISION TAG
KEYNOTE
CENTER LINE
#' - #" SPOT
ELEVATIONN
AIR BARRIER
MATCHLINE
CENTER /
COLUMN LINE
HIDDEN
OVERHEAD
SOIL
SAND, EIFS
FINISH COAT,
OR CEMENT
PLASTER
CMU
STONE
FIBERGLASS
BATT
INSULATION
FIBERGLASS
SEMI RIGID
INSULATION
MINERAL WOOL
SEMI RIGID
INSULATION
EXPANDED
POLYSTYRENE
RIGID
INSULATION
EXTRUDED
POLYSTYRENE
RIGID
INSULATION
CONCRETE/
PRECAST
CONCRETE
POLYISOCYANU
RATE RIGID
INSULATION
GYPSUM
BOARD
EXTERIOR
GYPSUM
SHEATHING
EXTERIOR
CEMENT
BOARD
COATED GLASS
MAT WATER
RESISTANT
GYP BD
PLYWOOD
COVER BOARD
2' x 2' ACT
CEILING
4' x 4' ACT
CEILING
1' x 1' ACT
CEILING
GYP. BD.
CEILING
RETURN AIR
GRILLE
SUPPLY AIR
GRILLE
EXHAUST AIR
GRILLE
2 x 2 LIGHT
FIXTURE
2 X 4 LIGHT
FIXTURE
SUSPENDED
FLUORESCENT
LIGHT
EXIT SIGN
LOCATION
PROJECT NOTES
(THIS IS A PLACE HOLDER)
1. REPETITIVE FEATURES NOTED TYPICAL ON
THE DRAWINGS SHALL BE COMPLETELY
PROVIDED AS IF DRAWN IN FULL. REPETITIVE
FEATURES NOT NOTED ON THE DRAWINGS
SHALL BE COMPLETELY PROVIDED AS IF
NOTED IN FULL.
2. DIMENSIONS ARE DRAWN TO THE FACE OF
BRICK, CONCRETE AND STEEL STUDS UNLESS
NOTED OTHERWISE, EXCEPT WHERE WALLS
ALIGN WITH GRID LINES. DIMENSIONS ARE
DRAWN TO THE CENTERLINE OF STRUCTURAL
STEEL, UNLESS NOTED OTHERWISE. GRID
LINES INDICATE THE CENTERLINE OF
COLUMNS & CONCRETE WALLS, UNLESS
NOTED OTHERWISE.
3. DOORS IN STUD WALLS NOT LOCATED BY
DIMENSION ON FLOOR PLANS OR DETAIL
DRAWINGS SHALL BE LOCATED 4 INCHES
FROM SURFACE OF ADJACENT
PERPENDICULAR WALL TO OUTSIDE EDGE OF
DOOR FRAME.
4. DOOR AND ROOM NUMBERS SHOWN ON
DRAWINGS ARE FOR CONSTRUCTION
PURPOSES. VERIFY NUMBERING SCHEME
WITH CONTRACTING OFFICER AND TENANT
UNIT PRIOR TO FABRICATING PERMANENT
LABELS AND SIGNAGE.
5. WOOD IN CONTACT WITH CONCRETE OR
MASONRY SHALL BE PRESERVATIVE TREATED
WOOD. ISOLATE P.T. WOOD FROM METALS.
6. PRECAST CONCRETE WORK SHALL HAVE
EASED EDGES, EITHER PROVIDED IN THE CAST
FORMWORK, OR TOOLED DURING THE CURING
PROCESS. EDGES SHALL BE EVEN AND OF A
DURABLE THICKNESS.
7. REFER TO THE SPECIFICATIONS FOR
INFORMATION THAT SUPPLEMENTS THESE
NOTES AND OTHER DRAWING INFORMATION.
8. ARCHITECTURAL DETAILS ARE INTENDED TO
SHOW THE GENERAL CHARACTER & EXTENT
OF THE PROJECT. THEY ARE NOT INTENDED
TO SHOW ALL DETAILS OF THE WORK.
DETAILS NOTED "TYPICAL" APPLY TO SIMILAR
WORK THROUGHOUT THIS BUILDING UNLESS
NOTED OTHERWISE.
9. THE CONTRACTOR IS RESPONSIBLE FOR THE
MEANS AND METHODS OF CONSTRUCTION &
ALL JOB RELATED SAFETY STANDARDS.
10. THE CONTRACTOR IS RESPONSIBLE FOR
ADVANCED REVIEW OF THE WORK REQUIRED
IN THE CONSTRUCTION DOCUMENTS AND THE
REQUIREMENTS FOR EXECUTING IT PROPERLY.
IF THE CONTRACTOR FINDS DISCREPANCIES IN
THE CONSTRUCTION DOCUMENTS OR
SPECIFICATION, THEN THE CONTRACTOR
SHALL NOTIFY THE CONTRACTING OFFICER
IMMEDIATELY. THE CONTRACTOR SHALL
WORK TO HAVE ALL DISCREPANCIES
RESOLVED WELL IN ADVANCE OF ACTUAL
CONSTRUCTION OCCURRING.
11. IN CASE OF DISCREPANCIES BETWEEN THE
CONSTRUCTION DOCUMENTS, REFERENCED
STANDARDS AND THE GOVERNING CODES,
THE CONTRACTING OFFICER WILL DETERMINE
WHICH SHALL GOVERN. DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF
THE CONTRACTING OFFICER BEFORE
PROCEEDING WITH THE WORK.
12. THE CONTRACTOR SHALL VERIFY ALL
DIMENSIONS, EXISTING UTILITIES, FIXTURES
AND CONDITIONS AT THE SITE. CONFLICTS
BETWEEN THE DRAWINGS AND ACTUAL SITE
CONDITIONS SHALL BE BROUGHT TO THE
ATTENTION OF THE CONTRACTING OFFICER
BEFORE PROCEEDING WITH THE WORK.
13. FIRE PROTECTION, PLUMBING, MECHANICAL,
ELECTRICAL AND TELECOMMUNICATIONS
FEATURES OR INFORMATION SHOWN ON
ARCHITECTURAL DRAWINGS IS FOR
COORDINATION AND LOCATION PURPOSES
ONLY. REFER TO DRAWINGS OF OTHER
DISCIPLINES FOR SPECIFIC DESIGN
INFORMATION ON COMPONENTS & SYSTEMS.
14. FLASHING COLOR SHALL MATCH ADJACENT
WALL OR ROOF COLOR, UNLESS
OTHERWISE NOTED.
15. SEE FIRE PROTECTION DRAWINGS FOR LIFE
SAFETY CODE INFORMATION.
SD SMOKE
DETECTOR
RECESSED
CAN LIGHTING
FIXTURE
6'-0" PROJECTION
SCREEN
INTERIOR ELEVATION
EXTERIOR ELEVATION
SECTION
ENLARGEMENT DETAIL
X-###
X-###
LEVEL
LEVEL NAME
LEVEL ELEVATION
ROOM NAME / NUMBER
SHEET NUMBER OF
REFERENCED VIEW
VIEW TITLE
X-###
1 View Name
SCALE: 1/8" = 1'-0"
R-###, Add Referencing Sheet
X-###
SCALE OF VIEW
SHEET NUMBER OF VIEW
VIEW NUMBER
SHEET NUMBER OF VIEW
VIEW NUMBER
SHEET NUMBER OF VIEW
VIEW NUMBER
VIEW NUMBER
SHEET NUMBER OF VIEW
ELEV.
NAME
ROOM NAME
ROOM NUMBER
ROOM SQUARE
FOOTAGE (OPTIONAL)
WALL TAGX#X
NORTH ARROW
PROJECT NORTH
TRUE NORTH
VIEW NUMBER
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:0
AM
A-001
AR
C
H
IT
E C
TU
R
AL
L E G
EN
D
, A
BB
R
EV
IA
TI
O N
S, PR
O
JE
C
T N
O
TE
S
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
S.
H
EN
D
R
IC
K
J.
ST
R
AS
SB
U
R G
ER
D .G
EB
LE
R
D .G
EB
LE
R
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 22 OF 51
M
AR
K D
ES
C
R
IP
TI
O
N D
A
B
C
1911 SF
STORAGE BAY
ROOF
CANOPY OVERHANG
A-011
A-011
0"
FIRST FLOOR
9' - 4"
TOP OF BRICK
-3' - 0"
TOF
24' - 0"
ROOF
1 2 3 4
16' - 0"
EAVE HEIGHT
A-011
0"
FIRST FLOOR
9' - 4"
TOP OF BRICK
-3' - 0"
TOF
24' - 0"
ROOF
D A
16' - 0"
EAVE HEIGHT
BC
12' - 4 3/16" panels
A-011
GENERAL NOTES
1. THE DRAWINGS ON THIS SHEET SHOW REQUIRED AIR
BARRIER CONTINUITY
2. ALL JOINTS AT OPENINGS, TRANSITIONS, AND PENETRATIONS
SHALL BE SEALED
3. SELF ADHERING MOISTURE/AIR BARRIER SHALL EXTEND 9"
AROUND ALL WALL OPENINGS AND WHERE OVERLAPPING
OTHER AIR BARRIER MATERIALS
4. REFER TO WALL SECTION AND ROOF DETAILS FOR
ADDITIONAL EXPLANATION OF AIR BARRIER DESIGN
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:0
AM
A-011
ST
O
R
AG
E B U
IL
D
IN
G
A I
R B
AR
R
IE
R
P
LA
N
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
S.
H
EN
D
R
IC
K
M .J
O H
N
SO
N
D .G
EB
LE
R
D .G
EB
LE
R
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 23 OF 51
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
SCALE: 1/8" = 1'-0"
STORAGE BUILDING OVERALL FIRST FLOOR PLAN
SCALE: 1/8" = 1'-0"
AIR BARRIER SECTION #1
SCALE: 1/8" = 1'-0"
AIR BARRIER SECTION #2
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
NO SCALE
NORTH
1911 SF
STORAGE BAY
A-301
A-301
1 2 3 4
A-301
A-301
D
A
ROOF
CANOPY OVERHANG
B
C
4'
8"
FA
C
E O
F M
A S O
N R
Y
8"
ST
E E
L
LI
N E
- P
EB
8"
1'
3"
1'
3"
FACE OF MASONRY
41' - 4"
FACE OF SLAB
20' - 3"
8"
STEEL LINE - PEB
40' - 0" 8"
1' - 0" 19' - 0" 19' - 0" 19' - 8" 2' - 3"
A-302
A-302
CJCJ
CJ
CJ
CJ
CJ
CJCJ
8'
0" 3'
4"
9'
4"
10" 3' - 4"
7' - 6" 6' - 0"
61' - 7"
KEYNOTES
DOWNSPOUT
BOLLARD, REFER TO CIVIL DRAWING
OVERHEAD DOOR
EDGE OF FLOOR SLAB, REFERENCE STRUCTURAL
EDGE OF ROOF CANOPY, SEE SHEET A-141
GENERAL NOTES
1. REFER TO SHEET A-001 FOR ADDITIONAL GENERAL NOTES.
2. REFER TO PLUMBING / MECHANICAL / ELECTRICAL FOR
ROOF PENETRATIONS NOT SHOWN ON ARCH.
3. PROVIDE CONT. SNOW GUARDS APPROX 2'-0" FROM EDGE
OF ROOF PER SPECIFICATIONS (NOT SHOWN FOR CLARITY).
4. COORDINATE ALL ROOFING DETAILS W/ MFR. TO MEET
WARRANTY REQ'S.
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:0
AM
A-101
ST
O
R
AG
E
BU
IL
D
IN
G
FI
R
ST
F
LO
O R
P
LA
N
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
S.
H
EN
D
R
IC
K
J.
ST
R
AS
SB
U
R G
ER
D .G
EB
LE
R
D .G
EB
LE
R
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 24 OF 51
SCALE: 3/16" = 1'-0"
STORAGE BUILDING OVERALL FIRST
FLOOR PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
4' 8' 12' 16'
SCALE: 3/16" = 1' - 0"
0'
NO SCALE
NORTH
A-301
A-301
1 2 3 4
D
A
B
C
2 3
2"
2"
2"
60' - 4"
9' - 0" 6' - 4"
6'
0"
KEYNOTES
DOWNSPOUT
STANDING SEAM METAL ROOF
6" X 6" GUTTER
UNIT HEATER CHIMNEY. SEE SHEET MP101 FOR DETAILS
GENERAL NOTES
1. REFER TO SHEET A-001 FOR ADDITIONAL GENERAL NOTES.
2. REFER TO PLUMBING / MECHANICAL / ELECTRICAL FOR
ROOF PENETRATIONS NOT SHOWN ON ARCH.
3. PROVIDE CONT. SNOW GUARDS APPROX 2'-0" FROM EDGE
OF ROOF PER SPECIFICATIONS (NOT SHOWN FOR CLARITY).
4. COORDINATE ALL ROOFING DETAILS W/ MFR. TO MEET
WARRANTY REQ'S.
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
7/
/2
8:
:0
AM
A-141
ST
O
R
AG
E
BU
I L D
IN
G
R
O O
F
PL
A N
M
AR
S O C
ST
O
RA
G
E B U
IL
DI
N G N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A
S.
H
EN
D
R
IC
K
J.
ST
R
AS
SB
U
R G
ER
D .G
EB
LE
R
D .G
EB
LE
R
JU
LY
R
- 64
R
TA
S U
BM
IT
TA
L
FO
R T
A .P
. H
IL
L , V
IR
G
IN
IA
SHEET 25 OF 51
SCALE: 3/16" = 1'-0"
STORAGE BUILDING ROOF PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
4' 8' 12' 16'
SCALE: 3/16" = 1' - 0"
0'
NO SCALE
NORTH
A
B
C
1 2
STORAGE BAY
CEILING LEGEND
OPEN TO STRUCTURE
PREFORATED METAL PANEL
1' x 4' TROFFER LIGHTING FIXTURE, SEE ELEC.
1' X 4' PENDANT LIGHT FIXTURE, SEE ELEC.
RECESSED CAN LIGHTING FIXTURE, SEE ELEC.
EXIT SIGN LOCATION, SEE ELEC.
PROJECTION SCREEN (SURFACE MOUNT)
OR
KEYNOTES
OPEN TO STRUCTURE ABOVE
PERFORATED METAL SOFFIT
PROP…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.