REVISED__SECTION_10_14_00.10_9_18_2018.pdf
PDF 30 KB Posted
- Attached to
- New Amendment for MARSOC Storage Shed - W9123618B0021 Federal contract opportunity
- Solicitation number
- W9123618B0021
About this file
Revised 10 14 00
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B.01.02_-_Bid_Abstract_-_MARSOC.pdf | ||
| B.01.02_-_Bid_Abstract_-_Culverts.pdf | ||
| REVISED_SHEET_A-151_9_17_2018.pdf | ||
| MARSOC_-_Amendment_5_-_release.pdf | ||
| REVISED_SHEET_I-101_9_17_2018.pdf | ||
| REVISED__SECTION_13_34_19_9_17_2018.pdf | ||
| Amendment_4_MARSOC.pdf | ||
| A.07.24_Amendment_0003_W9123618B0021.doc.pdf | ||
| A.07.24_Amendment_0002_W9123618B0021.doc.pdf | ||
| A.01.25_Site_Visit_Sign-in_Sheet_MARSOC.pdf | ||
| A.07.24_Amendment_0001_W9123618B0021.pdf | ||
| RTA_FAPH_MARSOC_STORAGE_BLDG_Specifications_-_17Aug18.pdf | ||
| RTA_FAPH_MARSOC_STORAGE_BLDG_DWGS.pdf | ||
| A.07.23_Solicitation_W9123618B0021.pdf | ||
| RTA__FAPH_MARSOC_STORAGE_BLDG_-_FFandE_for_IFB.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FAPH MARSOC STORAGE BUILDING 644MARSOCSTBLDG
RTA SUBMITTAL
SECTION 10 14 00.10
EXTERIOR SIGNAGE
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AMERICAN WELDING SOCIETY (AWS)
AWS C1.1M/C1.1 (2012) Recommended Practices for Resistance Welding
AWS D1.1/D1.1M (2015; Errata 1 2015; Errata 2 2016) Structural Welding Code - Steel
AWS D1.2/D1.2M (2014) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM A1011/A1011M (2017a) Standard Specification for Steel Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength
ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A36/A36M (2014) Standard Specification for Carbon Structural Steel
ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A924/A924M (2017a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM B108/B108M (2015) Standard Specification for Aluminum-Alloy Permanent Mold Castings
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
SECTION 10 14 00.10 Page 1
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM B26/B26M (2014; E 2015) Standard Specification for Aluminum-Alloy Sand Castings
ASTM B62 (2017) Standard Specification for Composition Bronze or Ounce Metal Castings
1.2 GENERAL REQUIREMENTS
All exterior signage must be provided by a single manufacturer. Exterior signage must be of the design, detail, sizes, types, and message content shown on the drawings, must conform to the requirements specified, and must be provided at the locations indicated. Submit exterior signage schedule in electronic media with spread sheet format. Spread sheet must include sign location, sign type, and message. Signs must be complete with lettering, framing as detailed, and related components for a complete installation. Each sample must consist of a complete sign panel with letters and symbols. Samples may be installed in the work, provided each sample is identified and location recorded. Submit three color samples for each material requiring color and 12 inch square sample of sign face color sample.
1.2.1 Wind Load Requirements
Exterior signage must be designed to withstand 90 mph windload. Submit design analysis and supporting calculations performed in support of specified signage.
1.2.2 Character Proportions and Heights
Letters and numbers on indicated signs for handicapped-accessible buildings must have a width-to-height ratio between 3:5 and 1:1 and a stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers on indicated signs must be sized according to the viewing distance from which they are to be read. The minimum height is measured using an upper case letter "X". Lower case characters are permitted.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Approved Detail Drawings; G
SD-03 Product Data
Modular Exterior Signage System
SECTION 10 14 00.10 Page 2
Installation
Exterior Signage; G
Wind Load Requirements
SD-04 Samples
Exterior Signage; G, DO
SD-10 Operation and Maintenance Data
Protection and Cleaning; G
1.4 QUALIFICATIONS
Signs, plaques, and dimensional letters must be the standard product of a manufacturer regularly engaged in the manufacture of the products. Items of equipment must essentially duplicate equipment that has been in satisfactory use at least 2 years prior to bid opening.
1.5 DELIVERY AND STORAGE
Materials must be wrapped for shipment and storage, delivered to the jobsite in manufacturer's original packaging, and stored in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Manufacturer's standard performance guarantees or warranties that extend beyond a one year period must be provided.
1.7 EXTRA STOCK
Provide 4 extra interchangeable message panels and extra stock of the following: message bars of each color and size for sign types [_____].
PART 2 PRODUCTS
2.1 MODULAR EXTERIOR SIGNAGE SYSTEM
Exterior signage must consist of a system of coordinated directional, identification, and regulatory type signs located where shown. Dimensions, details, materials, message content, and design of signage must be as shown. Submit manufacturer's descriptive data and catalog cuts.
2.2 DIMENSIONAL BUILDING LETTERS
2.2.1 Fabrication
Letters must be fabricated from cast aluminum 0.125 inch aluminum sheet or extruded aluminum . Letters must be cleaned by chemical etching or cleaned ultrasonically in a special degreasing bath. Letters must be packaged for protection until installation.
2.2.2 Typeface
Typeface must be helvetica medium .
SECTION 10 14 00.10 Page 3
2.2.3 Size
Letter size must be 6 inches.
2.2.4 Finish
Anodized aluminum Dark bronze with clear coat finish must be provided.
2.2.5 Mounting
Threaded studs or Steel U-bracket, cap screws, and expansion bolts of number and size as recommended by manufacturer, must be used for concealed anchorage. Letters which project from the building line must have stud spacer sleeves. Letters, studs, and sleeves must be of the same material.
Supply templates for mounting.
2.3 ALUMINUM ALLOY PRODUCTS
Aluminum alloy products must conform to ASTM B209 for sheet or plate, ASTM B221 for extrusions and ASTM B26/B26M or ASTM B108/B108M for castings. Aluminum extrusions must be provided at least 1/8 inch thick and aluminum plate or sheet at least 16 gauge thick. Welding for aluminum products must conform to AWS C1.1M/C1.1.
2.4 ANODIC COATING
Anodized finish must conform to AA DAF45 as follows:
Integrated color anodized designation AA-M10-C22-A32, Architectural Class 0.4 to 0.7 mil.
2.5 STEEL PRODUCTS
Structural steel products must conform to ASTM A36/A36M. Sheet and strip steel products must conform to ASTM A1011/A1011M. Welding for steel products must conform to AWS D1.2/D1.2M.
2.6 CAST BRONZE
Fabricate components with sharp corners, flat faces, and accurate profiles. Remove and polish burrs and rough spots. Finish faces to a uniform high luster. Cast bronze must be in accordance with ASTM B62.
2.7 ANCHORS AND FASTENERS
Exposed anchor and fastener materials must be compatible with metal to which applied and must match in color and finish and must be non-rusting, non-corroding, and non-staining. Exposed fasteners must be tamper-proof.
2.8 SHOP FABRICATION AND MANUFACTURE
2.8.1 Factory Workmanship
Work must be assembled in the shop, as far as practical, ready for installation at the site. Work that cannot be shop assembled must be given a trial fit in the shop to ensure proper field assembly. Holes for bolts and screws must be drilled or punched. Drilling and punching must produce clean, true lines and surfaces. Welding to or on structural steel must be in accordance with AWS D1.1/D1.1M. Welding must be continuous along the
SECTION 10 14 00.10 Page 4 entire area of contact. Exposed welds must be ground smooth. Exposed surfaces of work must have a smooth finish and exposed riveting must be flush. Fastenings must be concealed where practical. Items specified to be galvanized must be by hot-dip process after fabrication if practical.
Galvanization must be in accordance with ASTM A123/A123M and ASTM A653/A653M, as applicable. Other metallic coatings of steel sheet must be in accordance with ASTM A924/A924M. Joints exposed to the weather must be formed to exclude water. Drainage and weep holes must be included as required to prevent condensation buildup.
2.8.2 Dissimilar Materials
Where dissimilar metals are in contact, or where aluminum is in contact with concrete, mortar, masonry, wet or pressure-treated wood, or absorptive materials subject to wetting, the surfaces must be protected with a coat of asphalt varnish or a coat of zinc-molybdate primer to prevent galvanic or corrosive action.
2.8.3 Shop Painting
Surfaces of miscellaneous metal work, except nonferrous metal, corrosion resisting steel, and zinc-coated work, must be given one coat of zinc-molybdate primer or an approved rust-resisting treatment and metallic primer in accordance with manufacturer's standard practice. Surfaces of items to be embedded in concrete must not be painted. Upon completion of work, damaged surfaces must be recoated.
2.9 COLOR, FINISH, AND CONTRAST
Color must be selected from manufacturers standard colors. For buildings required to be handicapped-accessible, the characters and background of signs must be eggshell, matte, or other non-glare finish. Characters and symbols must contrast with their background - either light characters on a dark background or dark characters on a light background.
PART 3 EXECUTION
3.1 INSTALLATION
Signs, plaques, or dimensional letters must be installed in accordance with approved manufacturer's instructions at locations shown on the approved detail drawings; submit drawings showing elevations of each type of sign;
dimensions, details, and methods of mounting or anchoring; shape and thickness of materials; and details of construction. A schedule showing the location, each sign type, and message must be included. Circuits installed underground must conform to the requirements of Section 33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION. Steel conduits installed underground and illuminated signage mounted directly on buildings must be in conformance with the requirements of Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Signs must be installed plumb and true at mounting heights indicated, and by method shown or specified. Signs mounted on other surfaces must not be installed until finishes on such surfaces have been completed. Submit manufacturer's installation instructions and cleaning instructions.
3.1.1 Anchorage
Anchorage and fastener materials must be in accordance with approved manufacturer's instructions for the indicated substrate. Anchorage not
SECTION 10 14 00.10 Page 5 otherwise specified or indicated must include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood.
3.1.2 Protection and Cleaning
The work must be protected against damage during construction. Hardware and electrical equipment must be adjusted for proper operation. Glass, frames, and other sign surfaces must be cleaned in accordance with manufacturer's instructions. After signs are completed and inspected, cover all project identification, directional, and other signs which may mislead the public. Covering must be maintained until instructed to be removed by the Contracting Officer or until the facility is to be opened for business. Submit 4 copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guides. The instructions must include simplified diagrams for the equipment as installed. Signs must be cleaned, as required, at time of cover removal.
3.2 FIELD PAINTED FINISH
Miscellaneous metals and frames must be field painted in accordance with Section 09 90 00 PAINTS AND COATINGS. Anodized metals, masonry, and glass must be protected from paint. Finish must be free of scratches or other blemishes.
-- End of Section --
SECTION 10 14 00.10 Page 6
| DIVISION 10 - SPECIALTIES |
| 10 14 00.10 - EXTERIOR SIGNAGE |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 GENERAL REQUIREMENTS |
| 1.2.1 Wind Load Requirements |
| 1.2.2 Character Proportions and Heights |
| 1.3 SUBMITTALS |
| 1.4 QUALIFICATIONS |
| 1.5 DELIVERY AND STORAGE |
| 1.6 WARRANTY |
| 1.7 EXTRA STOCK |
| PART 2 PRODUCTS |
| 2.1 MODULAR EXTERIOR SIGNAGE SYSTEM |
| 2.2 DIMENSIONAL BUILDING LETTERS |
| 2.2.1 Fabrication |
| 2.2.2 Typeface |
| 2.2.3 Size |
| 2.2.4 Finish |
| 2.2.5 Mounting |
| 2.3 ALUMINUM ALLOY PRODUCTS |
| 2.4 ANODIC COATING |
| 2.5 STEEL PRODUCTS |
| 2.6 CAST BRONZE |
| 2.7 ANCHORS AND FASTENERS |
| 2.8 SHOP FABRICATION AND MANUFACTURE |
| 2.8.1 Factory Workmanship |
| 2.8.2 Dissimilar Materials |
| 2.8.3 Shop Painting |
2.9 COLOR, FINISH, AND CONTRAST
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.1.1 Anchorage |
| 3.1.2 Protection and Cleaning |
3.2 FIELD PAINTED FINISH