SPECIFICATIONS / REQUIREMENTS

Human Physiology and Neurobiology Teaching Kit (Quantity = 20 each):

Must include access to user-modifiable experiments for cardiovascular, respiratory, and neuromuscular physiology and animal neurobiology.

Must include following sensors:

o ECG/EMG (6-lead) o Non-invasive Blood Pressure sensor o Heart Sounds sensor o Spirometer o Grip Force sensor o Pulse probe o Temperature sensor o Event marker o Striated muscle transducer o Force transducer o Goniometer o Intracellular probe o Nerve bath chamber o Patellar reflex hammer o Needle electrodes o Hook electrodes o Bi-polar stimulating electrode o Wireless heart rate monitor o Respiration monitor o Galvanic Skin Response amplifier o Foot reaction switch o LED light source for visual reflexes o Electrodes for all applicable sensors

Must include high voltage stimulator (100 V, 0-20 mA)

Must include low voltage stimulator (±15VDC, 35 mA)

Must include BNC inputs

Must be able to receive data from at least eight inputs/channels

Must include an integrated barometer to ensure accuracy of spirometer measurements

System must be capable of operating without an internet connection

Software must include an open site license with unlimited free updates for life

Software and courseware must be freely distributable to students and instructors