Drawings.pdf

PDF 5 MB Posted

Attached to
Construct Conc Pad at Suwon AB (MATOC ONLY)
Solicitation number
W90VN619R0025
Issued by

About this file

Drawings

View the file

Other files

File Type Posted
Suwon_Air_Base_EAL.xls XLS spreadsheet
SF1442.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AF 1655

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 1 14

TITLE SHEET AND GENERAL NOTE

CONSTRUCT CONCRETE PAD

C-0

S C H E D U L E O F D R A W I N G S

REVISION STATUSDESCRIPTION OF DRAWINGS

GENERAL NOTE

DESCRIPTION OF DRAWINGS REVISION STATUS

TITLE SHEET, GENERAL NOTEC - 001

SUWON AB

CONSTRUCT SCAT PAD

DESIGN DRAWING

LOCATION PLANC - 1

DEMOLITION PLANC - 2

SITE PLAN-1C - 3

DETAIL-1C - 4

1. ALL CONCRETE WORK SHALL CONFORM TO ACI 211.1 AS MODIFIED BY AIR FORCE ETL 97-05 (CHANGE1).

2. AGGREGATES SHALL CONFORM TO ASTM C33.

3. CEMENT SHALL CONFORM TO ASTM C150, TYPE I OR II.

4. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH UFGS 32 13 11.

5. CONCRETE SHALL BE CONTINUOUSLY MOIST-CURED FOR AT LEAST SEVEN DAYS FOLLOWING COMPLETION OF CONCRETE

MAY BE USED INSTEAD OF MOIST-CURING.

6. SUBMIT A JOINT PLAN FOR APPROVAL PRIOR TO PLACING CONCRETE.

7. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED,

ALL LAITANCE REMOVED, THOROUGHLY WETTED, AND SLUSHED

8. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICE'S 48 HOURS PRIOR TO THE POURING OF ANY CONCRETE, NO POUR SHALL PROCEED WITHOUT THE CONSENT OF CONTRACTING OFFICE'S REPRESENTATION.

CONCRETE NOTES

NEW CONCRETE.

1. SPECIFIED FLEXURAL STRENGTH FOR CONCRETE PAD IS 4.5 MPA (650 PSI) AT 90 DAYS,

AS DETERMINED BY TEST MADE IN ACCORDANCE WITH ASTM C 78 OR KS F 2325.

DESIGN CRITERIA;

2. THE MAXIMUM ALLOWABLE SLUMP OF THE CONCRETE AT THE POINT OF PLACEMENT IS 75mm (3in.).

FINISHING OPERATION. ALTERNATIVELY, A WHITE PIGMENTED MEMBRANCE FORMING CURING COMPOUND MEETING COE CRD-C 300

9. SUBMIT RESULTS OF FREEZING-THAWING TEST, SIEVE ANALYSIS, ALKALI SILICA REACTIVITY, AND L.A. ABRASION TEST.

10. SUBMIT A RESULT OF DENSITY TEST FOR APPROVAL PRIOR TO PLACING CONCRETE.

11. THE CONTRACTOR SHALL MAKE 18 SPECIMENS FOR THE STRENGTH TEST FOR EACH TIME WHEN CONCRETE IS POURED.

9 SPECIMENS SHALL BE CURED AT THE JOB SITE WHILE THE OTHER 9 SPECIMENS SHALL BE CURED IN THE LAB.

3. THE COMPRESSIVE CONCRETE STRENGTH AT 28 DAYS FOR MANHOLE IS MINIMUM 27MPA

06 DETAIL-2C - 5

07 JOINT DETAILC - 6

08 FENCE-1C - 7

09 FENCE-2C - 8

10 FENCE-3C - 9

11 FENCE-4C - 10

12 SCAT MOVINGC - 11

13 SCAT DRAWING-1C - 12

14 SCAT DRAWING-2C - 13

NA

12122

12523

12216

12521

12506

12507

12502

12504

12508

12116

12404

12200

12208

12336

12109

12529

12110

12203

12205

2221 2229

12512

12128

12402

W32

AF 1655

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 2 14

LOCATION PLANLOCATION PLAN

THIS PROJECT

CONSTRUCT CONCRETE PAD

C-1

AF 1655

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 3 14

DEMOLITION PLAN

CONSTRUCT CONCRETE PAD

C-2

LEGEND

EXISTING EARTH BERM

REMOVE EXISTING FENCE

L=45M, H=2.4M

REMOVE EXISTING EARTH BERM AND CURB

APPROXIMATELY 200 CUBIC METERS

36.00

25.00

20.39

6.00

14.92

10.18

26.37

AF 1655

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 4 14

SITE PLAN-1

CONSTRUCT CONCRETE PAD

C-3

NOTE

EXISTING EARTH BERM

EXISTING PARKING LOT

EXISTING FENCE

INSTALL NEW FENCE, H=2.1M, L=60M

SEE C-7~10, TYPE FE-6

N: 4122907.0616 E: 323047.4600

N: 4122881.4567 E: 323036.6920

EXISTING FENCE

EQUIPMENT PAD

SEE C-5

TYPICAL CONCRETE PAD

SEE C-4

TRUCK PAD

SEE C-5

TYPICAL CONCRETE PAD

SEE C-4

GROUNDING POINT, 4EA

SEE C-6

* THE CONTRACTOR SHOULD SUBMIT THE SHOP DRAWING FOR CONCRETE PADS SLOPE BEFORE CONSTRUCTION.

* SLOPE OF CONCRETE PADS INCLUDING EQUIPMENT PAD SHOULD BE AT LEAST 1%.

* THE CONTRACTOR SHOULD INSTALL A DRAIN PIPE WITH LOCKABLE VALVE IN THE CONTAINMENT WALL. (SEE C-6)

* THE CONTRACTOR SHOULD COORDINATE WITH 607 MMS/CE BEFORE INSTALLING THE GROUNDING POINT TO DETERMINE THE LOCATION.

PAD SLOPE 1.0%

P A

D S

LO

P

E 1.0%

INSTALL DRAIN PIPE WITH LOCKABLE VALVE

SEE C-6

INSTALL GROUNDING FOR FENCE

SEE C-9

GROUINSTALL GROUNDING FOR FENCE

SEE C-9

GROUND FENCINGINSTALL GROUNDING FOR FENCE

SEE C-9

36.00

25.00

20.39

6.00

26.37

9.95

14.88 3.25

3.97

6.00 6.00

AF 1655

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 5 14

DETAIL-1

CONSTRUCT CONCRETE PAD

C-4

A. TRUCK PAD AND EQUIPMENT PAD DETAIL

EXST PAVEMENT NEW PAVEMENT

PREPARED MINIMUM 20 INCHES BASE COURSE.

CONSTRUCTION JOINT

n

D28 drilled hole.

Use epoxy resin ASTM C881, Type IV, Grade 3 or equivalent

REMOVE EXISTING EXPANSION JOINT

NOT REPLACE.

IF EXPANSION JOINT IS IN THE EXISTING PAVEMENT

HALF

HALF

B. TYPICAL CONCRETE PAD

PAINT AND OIL

THIS END OF DOWEL

TRANSVERSE CONTRACTION

OR DOWELED CONSTRUCTION

D13 BARS @ 380 OC

1/

H d in ch

H

AL

F

@ 380 OC EW

D13 BARS

C-2

75 EDGE OF

PCC PAVEMENT

ST

EE

L

BA

R

LE

N

G

TH

25 DIA X 400 L

H d

C. SLAB REINFORCEMENT DETAIL

EQUIPMENT PAD

T R

U C

K P

A D

* ALL TYPICAL SLABS SHOULD BE REINFORCED.

CONTAINMENT WALL

THICKENED EDGE

THICKENED EDGE WITH EXPANSION JOINT

EXPANSION JOINT

DOWELED JOINT

COMPACTED BASECOURSE

25MM CHAMFER (TYP.)

NEW CONCRETE PAD

EXPANSION JOINT

D19 REBAR SPACED 300 O.C. TOP AND BOTTOM

D13 REBAR

D16 REBAR

(TYP. ALL AROUND)

D13 REBAR AT 600 O.C.

(TYP. ALL AROUND)

AF 1655

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 6 14

DETAIL-2

CONSTRUCT CONCRETE PAD

C-5

(CONT.) 6000

EXISTING CON'C PAD

NEW CON'C PAD

200200

620 150

4.03% SLOPE (APPROX.)

D16 REBAR SPACE 300 O.C.

BOTH WAYS, BOTH DIRECTIONS

COMPACTED BASECOURSE

E. EQUIPMENT PAD SECTION VIEW

F. TRUCK PAD SECTION VIEW

25MM CHAMFER (TYP.)

COMPACTED BASECOURSE500

D13 REBAR SPACED 380 O.C

D. TYPICAL PAD WITH CONTAINMENT WALL SECTION VIEW

3250~3800

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 7 14

JOINT DETAILS

CONSTRUCT CONCRETE PAD

C-6

POURED

JOINT SEALER

MIN

20 THK

NONEXTRUDING

JOINT FILLER

19 28

BACKER

MATERIAL

POURED

JOINT SEALANT

SEPARATING

TAPE BACKER

MATERIAL

POURED

JOINT SEALANT

W = WIDTH OF SEALANT

RESERVOIR (SEE TABLE)

D = DEPTH OF SEALANT;

1.0 TO 1.5 TIMES W

T = DEPTH OF INITIAL SAW CUT,

1/4 OF THE SLAB THICKNESS FOR

PAVEMENT LESS THAN 12 IN.;

3 IN. FOR PAVEMENTS 12-18 IN.;

OR 1/6 OF THE SLAB THICKNESS

FOR PAVEMENTS OVER 18 IN.

TABLE

JOINT SPACING

FT

W, IN.

< 25

MIN MAX

1/2 5/8

25 TO 50 3/4 7/8

> 50 1 1-1/8

NOTES : 1. SEPARATING TAPE OR BACKER

MATERIAL REQUIRED TO PRE-

VENT JOINT SEALANT FROM

FLOWING INTO SAWCUT, TO SEPA-

RATE NONCOMPATIBLE MATERIALS,

AND TO PREVENT SEALANT FROM

BONDING TO BOTTOM OF RESERVOIR.

2. TOP OF SEALANT WILL BE 1/8 IN. TO

1/4 IN. BELOW TOP OF PAVEMENT.

FNSH PARKING LOT GL

20 COPPER-WELDED SCREW ANCHOR GROUNDING ROD

Max. 150mm

127mm

APPROX. 80mm R.

Max. 150mm

75mm

DRAIN PIPE 10

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 8 14

FENCE-1

C-7

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 9 14

FENCE-2

C-8

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 10 14

FENCE-3

C-9

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 11 14

FENCE-4

C-10

A

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 12 14

SCAT MOVING

CONSTRUCT CONCRETE PAD

C-11

NOTE

TEMPORARY SCAT SITE

PERMANENT SCAT SITE

SEE C-12, C-13

* THE CONTRACTOR SHOULD MOVE/INSTALL THE SELF CONTAINED ABOVE TANK (SCAT) AND MANIFOLDS FROM THE TEMPORARY SCAT SITE TO PERMANENT SCAT SITE.

* SEE DRAWING C-12 AND C-13 FOR SCAT SIZE. THE WEIGHT OF SCAT IS APPROXIMATELY 15 TONS. (Crane over 50 tons is required)

1. DISASSEMBLE EXISTING SCAT AND MANIFOLDS WITH ALL OTHER ACCESSORIES ON THE TEMPORARY SITE.

2. MOVE SCAT AND MANIFOLDS WITH ALL OTHER ACCESSORIES FROM TEMPORARY SITE TO PERMANENT SITE.

3. INSTALL THE SCAT AND MANIFOLDS WITH ALL OTHER ACCESSORIES ON THE PERMANENT SITE.

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 13 14

SCAT DRAWING-1

C-12

FORM

FEB 74

B

C

D

8 7 6 5

CODE IDENT NO.

ENGINEERING DRAWING LAYOUT D

AIR FORCE AUTHENTICATION

AIR FORCE RELEASE

ENG

CHK

DR

SIZE

SCALE

TITLE

AS SHOWN

PARTS LIST

4 3 2

DRAWING NO

SHEET OF

A

B

C

D

DATE

8 7 6 5 4

NONE 14 14

SCAT DRAWING-2

C-13

04. Drawings for Construct Concrete Pad
C-0
C-1
C-2
C-3
C-4
C-5
C-6
C-7
C-8
C-9
C-10
C-11
C-12
C-13

C-3 REVISED

File details come from the government source that posted it.