REVISIONS

REV ZONE DESCRIPTION DATE APPROVED

A N/A INITIAL RELEASE 2/6/14

SEE BLOCK

SIGNATURES

SHEET REMOVED UT INSPECTION FROM NOTE 9. NB B

3AND4

REMOVED UT CERT FROM LIST IN NOTE 10 3/3/14

PASADC ADDED NOTE 11.

NOTE 9.B.I- ADDED PENETRANT TEST METHOD

~A- ;/~r/6 CLARIFICATION

NOTE 9.B.I.2- ADDED SUB-NOTE TO CLARIFY

ACCEPTANCE CRITERIA

.p .De

SHEET NOTE IO- ADDED NEW NOTE TO CLARIFY ABOUT M1

c 3,4 WEDGE AND YIELD TESTING REQUIREMENTS

NOTE II -ADDED REQUIREMENT FOR CERTS TO

AND5 BE ON COMPANY LETTERHEAD WITH

CERTIFYING OFFICIAL. ADDED SPECIFICS TO

I I.E ABOUT WHICH TABLE APPLIED. ADDED

II.H TO REFERENCE NEW NOTE IO

SKETCH- ADDED MARKING LOCATIONS

NAVSEA Tech Pub, Requirements for Non-

T907 4-AS-GIB-01 0/271 Destructive Testing Methods

NO. TITLE I DENT

REFERENCES

DISTRIBUTION STATEMENT A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS UNLIMITED

UNITS AND TOLERANCES DEPARTMENT OF THE NAVY

NORFOLK NAVAL SHIPYARD DETACHMENT

NAVAL FOUNDRY AND PROPELLER CENTER

UNLESS OTHERWISE SPECIFIED MACH SURFACES PHILADELPHIA, PA

SHALL HAVE A 125 RMS FINISH. ALL UNITS ARE IN

INCHES & TOLERANCES SHALL BE AS FOLLOWS:

+/- 0.06 FOR ONE DECIMAL PLACE

+/- 0.020 FOR TWO DECIMAL PLACES

+/- 0.005 FOR THREE DECIMAL PLACES KSOO TAILCONE +/- 0.5° FOR ANGLES

SHARP FILLETS R.015 MAX SCREWS TOL PER ASME Y14.5- 1994

PREPARED DATE

Nathan Bird 2/6/14 SIZE CODE IDENT: NFPC DRAWING NO. REV

CHECKED

John Garner 2/6/14

A CODE PCI1860-E1 c PROJECT ENG 1421 Nathan Bird 2/6/14

APPROVED

Pete Sherwin 2/6/14 SCALE: None SHEET 1 OF 5

GENERAL NOTES:

1) THE MATERIAL SHALL BE GRADE 500 K-MONEL, QQ-N-286 REV G ONLY, IN ACCORDANCE WITH MIL- DTL-1222. THE SLOW STRAIN RATE TENSILE (SSRT) TESTING REQUIRED BY QQ-N-286G MUST BE

PERFORMED BY ONE OF THE FOLLOWING NAVSEA APPROVED TESTING FACILITIES:

A. HUNTINGTON ALLOYS, A SPECIAL METALS COMPANY

ATTN: FRANK VELTRY, 3200 RIVERSIDE DRIVE, HUNTINGTON, WV 25705

PHONE: (304) 526-5759, FAX: (304) 526-5973

B. METALLURGICAL CONSULTANTS, INC, ATTN: W. M. BUEHLER

4820 CAROLINE, PO BOX 88046, HOUSTON, TX 77288-0046

PHONE :(713) 526-6351, FAX: (713) 526-5576

C. NAVAL SURFACE WARFARE CENTER (NSWC), CARDEROCK DIVISION, ATTN: ERIC FOCHT

CODE 614, 3500 MACARTHUR BLVD., WEST BETHESDA, MD 20817-5700

PHONE :(301) 526-6351, FAX: (301) 526-5576

D. TELEDYNE ALLVAC, ATTN: DR. W. D. CAO

2020 ASHCRAFT AVE, MONROE, NC 28110

PHONE :(704) 289-4511, FAX: (704) 289-4269

E. MANNESMANN ROHRENWERKE, MANNESMANN FORSCHUNGSINSTITUT (MFI)

ATTN: DR. WEISS, POSTFACH 251160, 47251 DUISBURG, GERMANY

PHONE : 011-49-0203-999-3194, FAX: 011-49-0203-999-4415

F. WESTMORELAND MECHANICAL TESTING & RESEARCH, INC.

ATTN: ANDREW WISNIEWSKI, P.O. BOX 388, YOUNGSTOWN, PA 15696-0388

PHONE : (724) 537-3131, FAX: (724) 537-3151

2) FASTENER THREADS AND HEADS SHALL BE MACHINED TO SIZE. NO OTHER FORMS ARE

ACCEPTABLE. HEADS AND THREADS SHALL NOT BE FORGED OR FORMED.

3) A QUALITY ASSURANCE PROGRAM SHALL BE ESTABLISHED PER ISO 9001:2000. THE SUPPLIER MAY

SUBSTITUTE AN ALTERNATE QUALITY ASSURANCE SYSTEM, SUBJECT TO APPROVAL BY NFPC.

4) A CALIBRATION SYSTEM SHALL BE USED THAT MEETS ISO 10012-1. THE SUPPLIER MAY SUBSTITUTE

AN ALTERNATE CALIBRATION SYSTEM, SUBJECT TO APPROVAL BY NFPC.

5) REMOVE ALL BURRS AND SHARP EDGES. MAX RADIUS PERMITTED PER TOL BLOCK.

6) THREAD DIMENSIONS AND DESIGNATIONS SHALL BE INTERPRETED PER FED-STD-H28 AND ANSI

Y14.6 RESPECTIVELY.

7) FASTENERS SHALL HAVE SELF-LOCKING INSERTS, TYPE N ONLY, INSTALLED PER STANDARD MIL-F- 18240 REVISION E OR LATER. TEST TORQUE VALUES PROVIDED BELOW SHALL BE USED IN LIEU OF TABLE II IN THE STANDARD. SEATING TORQUE IS NOT APPLICABLE TO REVISION E OF THE MIL-STD:

SEATING TORQUE MIN PREVAILING TORQUE MAX PREVAILING TORQUE

25,000 INCH-LBS 393 INCH-LBS 2475 INCH-LBS

A. THERE SHALL BE NO BURRS IN THE AREA OF THE SELF-LOCKING ELEMENT. THIS

SUPERSEDES THE WORKMANSHIP REQUIREMENT TO THE CONTRARY IN PARAGRAPH 3.6 OF

THE MIL-STD.

B. ONCE TESTING IS COMPLETE, NEW SELF-LOCKING ELEMENTS SHALL BE INSTALLED PER THE

REQUIREMENTS OF THE MIL-STD, INTO THE FASTENERS USED FOR TESTING, BEFORE

DELIVERY TO NFPC.

C. THE MATERIAL FOR THE TORQUE TESTING NUT SHALL BE NIALBRZ, ASTM B150 ALLOY

NUMBER C63200 OR SIMILAR TENSILE STRENGTH MATERIAL. THE SUPPLIER IS RESPONSIBLE

FOR THE NUTS (NFPC DOES NOT PROVIDE)

D. THE VENDOR INSTALLING THE LOCKING PELLET IS REQUIRED TO BE QUALIFIED PER QPL-

18240.

SIZE CODE IDENT: NFPC DRAWING NO. REV

A

CODE

1421 PCI1860-E1 C

SCALE: None SHEET 2 OF 5

GENERAL NOTES CONTINUED:

8) THE VENDOR SHALL PERFORM AN ADDITIONAL RECEIPT INSPECTION OF THE BAR STOCK

CONSISTING OF A CHEMICAL TEST CONDUCTED ON ALL LOTS OF MATERIAL. THE CHEMICAL TEST

SHALL VERIFY THAT THE MATERIAL MEETS THE REQUIREMENTS OF QQ-N-286G. THE PRIMARY

SUPPLIER OR A SUBCONTRACTOR SHALL ACCOMPLISH THIS TESTING. TESTING AND RESULTS FROM

THE BAR STOCK SUPPLIER DOES NOT SATISFY THIS REQUIREMENT.

9) THE FOLLOWING EVALUATIONS SHALL BE PERFORMED ON 100% OF THESE FASTENERS:

A. HARDNESS TESTS

I. HARDNESS TESTS SHALL BE PERFORMED PER ASTM E-18, ROCKWELL C SCALE

(HRC) ON FASTENERS IN THE HEAT TREATED CONDITION. TEST METHODS OTHER

THAN ROCKWELL C ARE NOT PERMITTED WITHOUT PRIOR APPROVAL OF NFPC.

II. THREE HRC READINGS SHALL BE TAKEN AT EACH END AND AVERAGED. READINGS

ON THE POINT END SHALL BE TAKEN AT ½ RADIUS. ANY THREE LOCATIONS ON THE

HEAD END ARE ACCEPTABLE. ALL HARDNESS READINGS SHALL BE WITHIN THE

ACCEPTABLE RANGE. THE ACCEPTABLE IS HRC 25-35.

III. THE AVERAGED READINGS FROM EACH END OF EACH FASTENER SHALL BE

REPORTED, HOWEVER RESULTS DO NOT NEED TO BE IDENTIFIED TO SPECIFIC

PIECES. INDENTATIONS ON THE SURFACE OF THE FASTENERS ARE NOT REQUIRED

TO BE REMOVED.

B. LIQUID PENETRANT INSPECTION (PT)

I. PT SHALL BE CONDUCTED ON EACH ITEM PER MIL-DTL-1222 (SECTION 4.3.3,

METHODS PER NAVSEA T9074-AS-GIB-010/271), WITH THE FOLLOWING ADDITIONS

AND EXCEPTIONS:

1. NO CRACKS ARE ACCEPTABLE ON THE ANY FASTENER HEX SOCKET

OPENING OR ON ANY FASTENER HEAD.

2. EXCEPT AS NOTED ABOVE PT ACCEPTANCE CRITERIA IS PER ASTM

F788/F788M WITH SUPPLEMENTARY INSPECTION S1.

II. PT RESULTS SHALL BE DOCUMENTED IN THE CERTIFICATION REPORT. THE RESULTS

FROM EACH FASTENER SHALL BE REPORTED, HOWEVER RESULTS DO NOT NEED TO

BE IDENTIFIED TO SPECIFIC PIECES.

C. IN ADDITION TO THE FASTENER MARKING REQUIREMENTS OF MIL-DTL-1222, EACH PIECE

SHALL BE STAMPED WITH THE MANUFACTURING LOT NUMBER ON THE POINT END AS

CERTIFICATION OF ACCEPTABILITY OF THE ABOVE HARDNESS, AND PT TESTS.

10) MIL-DTL-1222J REQUIRES WEDGE TENSILE TESTING AND YIELD STRENGH OF GRADE 500 HEX CAP SCREWS. ONLY THE SAMPLE SIZED REQUIRED BY MIL-DTL-1222J TABLES XI AND XII (PLAN C) ARE REQUIRED TO BE TESTED. THE FOLLOWING IS CLARIFICATION OF THE REQUIREMENTS FOR THESE

PARTICULAR HEX CAP SCREWS:

A. FINISHED BOLTS ARE REQUIRED TO BE WEDGE TESTED IAW MIL-DTL-1222J SECTION 4.5.2.3 (SECTION 3.5 OF ASTM F606). THE LOAD FOR THE TEST IS GREATER THAN 150,000 LBS AND SO THE PROVISIONS OF MIL-DTL-1222J SECTION 4.5.2.3 FOR MACHINE LIMITS APPLY. THIS IS

A DESTRUCTIVE TEST AND PARTS MAY NOT BE REWORKED AND SUPPLIED TO NFPC.

B. YIELD STRENGTH TESTS ARE REQUIRED IAW MIL-DTL-1222J SECTION 4.5.2.4 (METHOD 2 OR

2A OF ASTM F606). BAR STOCK MAY BE USED FOR THIS TEST IAW MIL-DTL-1222J SECTION

4.5.2.7 PROVIDED THE PROVISIONS ARE MET (SAME LOT, STARTING STOCK IS 4.5” DIAMETER

OR LESS AND THE WEDGE TENSILE STRENGTH TEST IS COMPLETED SATISFACTORY).

SIZE CODE IDENT: NFPC DRAWING NO. REV

A CODE

SCALE: None SHEET 3 OF 5

11) CERTIFICATE OF CONFORMANCE IS REQUIRED FOR ACCEPTANCE. ADDITIONALLY THE VENDOR SHALL PROVIDE THE FOLLOWING MATERIAL CERTIFICATIONS FOR EACH UNIQUE HEAT OR LOT USED TO MANUFACTURE THESE SCREWS. MISSING OR INCOMPLETE CERTIFICATIONS MAY BE CAUSE FOR REJECTION OF THE ORDER. . EACH CERTIFICATION SHALL INCLUDE THE HEAT OR LOT NUMBER FOR TRACEABILITY, BE ON COMPANY LETTERHEAD AND INCLUDE THE NAME, TITLE AND SIGNATURE OF

THE CERTIFYING OFFICIAL.

A. BAR STOCK MATERIAL CERTIFICATION INCLUDING RESULTS OF ULTRASONIC, CHEMICAL

AND MECHANICAL TESTS PER QQ-N-286G.

B. RESULTS OF THE SLOW STRAIN RATE TEST (SSRT) REQUIRED BY QQ-N-286G. NOTE: ONLY

THOSE VENDORS LISTED IN NOTE 1 ARE ACCEPTABLE.

C. RESULTS OF THE TORQUE TESTING PER MIL-F-18240 REV E OR LATER IN ACCORDANCE

WITH NOTE 7.

D. RESULTS OF SEPARATE CHEMICAL INSPECTION IN ACCORDANCE WITH NOTE 8.

E. RESULTS OF DIMENSIONAL INSPECTION REQUIRED BY MIL-DTL-1222 (SAMPLING PLAN A PER

TABLE XII OF THE 11 CHARACTERISTICS IN TABLE XIV).

F. RESULTS OF THE HARDNESS TEST (FOR EACH FASTENER) AS SPECIFIED IN NOTE 9.A.

G. RESULTS OF THE PT INSPECTION (FOR EACH FASTENER) AS SPECIFIED IN NOTE 9.B.

H. RESULTS OF THE WEDGE TENSILE STRENGTH AND YIELD STRENGTH TESTS AS SPECIFIED

IN NOTES 10.A AND 10.B.

12) ALL SCREWS SHALL BE WRAPPED INDIVIDUALLY IN POLYETHYLENE MESH SLEEVES (ULINE PN S-

6581 OR EQ) AND PACKAGED TOGETHER SECURELY IN A COVERED WOODEN CRATE PER ASTM

D7478, TYPE I, CLASS 2, STYLE A, WITH A SCREWED DETACHABLE TOP. SCREWS SHALL BE

PACKAGED SUCH THAT CONTACT BETWEEN SCREWS DURING SHIPMENT IS NOT POSSIBLE.

SCALE: None SHEET 4 OF 5

SCALE: None SHEET 5 OF 5

MARKING LOCATION FOR MATERIAL

SYMBOL (K), MANUFACTURER’S

SYMBOL AND THE LOT NUMBER (PER

MIL-DTL-1222J SECTION 3.13.1).

MARK LOT NUMBER PER NOTE 9.C

(ASME B18.2.1)

REVISIONS

REV SHEET DESCRIPTION DATE APPROVED

A N/A Initial Release See Block Signatures

NOTE 9.B.I- ADDED PENETRANT TEST

METHOD CLARIFICATION

t/;n~t( NOTE 9.B.I.2- ADDED SUB-NOTE TO CLARIFY ACCEPTANCE CRITERIA ;vfJ ~JJL_. NOTE 10- ADDED NEW NOTE TO CLARIFY

3,4 ABOUT AXIAL AND YIELD TESTING

B REQUIREMENTS

AND5 NOTE 12- ADDED REQUIREMENT FOR CERTS

TO BE ON COMPANY LETTERHEAD WITH

CERTIFYING OFFICIAL. ADDED SPECIFICS

TO 12.E ABOUT WHICH TABLE APPLIED.

ADDED 12.H TO REFERENCE NEW NOTE 10.

SKETCH- ADDED MARKING LOCATIONS

NO. TITLE I DENT

REFERENCES

DISTRIBUTION STATEMENT A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS UNLIMITED

UNITS AND TOLERANCES DEPARTMENT OF THE NAVY

NORFOLK NAVAL SHIPYARD DETACHMENT

NAVAL FOUNDRY AND PROPELLER CENTER

UNLESS OTHERWISE SPECIFIED MACH SURFACES PHILADELPHIA, PA

SHALL HAVE A 125 RMS FINISH. ALL UNITS ARE IN

INCHES & TOLERANCES SHALL BE AS FOLLOWS:

+/- 0.06 FOR ONE DECIMAL PLACE

+/- 0.020 FOR TWO DECIMAL PLACES

+/- 0.005 FOR THREE DECIMAL PLACES

+t- 0,5• FOR ANGLES KSOO SB STUD

SHARP FILLETS R.015 MAX

TOL PERASME Y14.5 -1994

PREPARED DATE

Nathan Bird 2/19/14 SIZE CODE IDENT: NFPC DRAWING NO. REV

CHECKED

John Garner 2/19/14

A CODE PCI1856-E1 B PROJECT ENG 1421

Nathan Bird 2/19/14

APPROVED

Pete Sherwin 2/24/14 SCALE: None SHEET 1 OF 4

GENERAL NOTES:

1) THE MATERIAL SHALL BE GRADE 500 K-MONEL, QQ-N-286 REV G ONLY, IN ACCORDANCE WITH MIL- DTL-1222J. THE SLOW STRAIN RATE TENSILE (SSRT) TESTING REQUIRED BY QQ-N-286G MUST BE

PERFORMED BY ONE OF THE FOLLOWING NAVSEA APPROVED TESTING FACILITIES:

A. HUNTINGTON ALLOYS, A SPECIAL METALS COMPANY

ATTN: FRANK VELTRY, 3200 RIVERSIDE DRIVE, HUNTINGTON, WV 25705

PHONE: (304) 526-5759, FAX: (304) 526-5973

B. METALLURGICAL CONSULTANTS, INC, ATTN: W. M. BUEHLER

4820 CAROLINE, PO BOX 88046, HOUSTON, TX 77288-0046

PHONE :(713) 526-6351, FAX: (713) 526-5576

C. NAVAL SURFACE WARFARE CENTER (NSWC), CARDEROCK DIVISION, ATTN: ERIC FOCHT

CODE 614, 3500 MACARTHUR BLVD., WEST BETHESDA, MD 20817-5700

PHONE :(301) 526-6351, FAX: (301) 526-5576

D. TELEDYNE ALLVAC, ATTN: DR. W. D. CAO

2020 ASHCRAFT AVE, MONROE, NC 28110

PHONE :(704) 289-4511, FAX: (704) 289-4269

E. MANNESMANN ROHRENWERKE, MANNESMANN FORSCHUNGSINSTITUT (MFI)

ATTN: DR. WEISS, POSTFACH 251160, 47251 DUISBURG, GERMANY

PHONE : 011-49-0203-999-3194, FAX: 011-49-0203-999-4415

F. WESTMORELAND MECHANICAL TESTING & RESEARCH, INC.

ATTN: ANDREW WISNIEWSKI, P.O. BOX 388, YOUNGSTOWN, PA 15696-0388

PHONE : (724) 537-3131, FAX: (724) 537-3151

2) THREADS SHALL BE ROLLED.

3) A QUALITY ASSURANCE PROGRAM SHALL BE ESTABLISHED PER ISO 9001:2000. THE SUPPLIER MAY

SUBSTITUTE AN ALTERNATE QUALITY ASSURANCE SYSTEM, SUBJECT TO APPROVAL BY NFPC.

4) A CALIBRATION SYSTEM SHALL BE USED THAT MEETS ISO 10012-1. THE SUPPLIER MAY SUBSTITUTE

AN ALTERNATE CALIBRATION SYSTEM, SUBJECT TO APPROVAL BY NFPC.

5) REMOVE ALL BURRS AND SHARP EDGES. MAX RADIUS PERMITTED PER TOL BLOCK.

6) ALL THREAD DIMENSIONS AND INSPECTION SHALL BE IN ACCORDANCE WITH FED-STD-H28, SYSTEM

21. THREAD DESIGNATION SHALL BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.6.

7) FASTENERS SHALL HAVE SELF-LOCKING INSERTS, TYPE N ONLY, INSTALLED PER STANDARD MIL-F- 18240 REVISION E OR LATER. TEST TORQUE VALUES SHALL BE PER TABLE II IN THE STANDARD.

A. ONCE TESTING IS COMPLETE, NEW SELF-LOCKING ELEMENTS SHALL BE INSTALLED PER THE

REQUIREMENTS OF THE MIL-STD, INTO THE FASTENERS USED FOR TESTING, BEFORE

DELIVERY TO NFPC.

B. THE MATERIAL FOR THE TORQUE TESTING NUT SHALL BE NIALBRZ, ASTM B150 ALLOY

NUMBER C63200 OR SIMILAR TENSILE STRENGTH MATERIAL. THE SUPPLIER IS RESPONSIBLE

FOR THE NUTS (NFPC DOES NOT PROVIDE)

C. THE VENDOR INSTALLING THE LOCKING PELLET IS REQUIRED TO BE QUALIFIED PER QPL-

18240.

SIZE CODE IDENT: NFPC DRAWING NO. REV

A

CODE

1421 PCI1856-E1 B

SCALE: None SHEET 2 OF 4

8) THE VENDOR SHALL PERFORM AN ADDITIONAL RECEIPT INSPECTION OF THE BAR STOCK

CONSISTING OF A CHEMICAL TEST CONDUCTED ON ALL LOTS OF MATERIAL. THE CHEMICAL TEST

SHALL VERIFY THAT THE MATERIAL MEETS THE REQUIREMENTS OF QQ-N-286G. THE PRIMARY

SUPPLIER OR A SUBCONTRACTOR SHALL ACCOMPLISH THIS TESTING. TESTING AND RESULTS FROM

THE BAR STOCK SUPPLIER DOES NOT SATISFY THIS REQUIREMENT.

9) THE FOLLOWING EVALUATIONS SHALL BE PERFORMED ON 100% OF THESE FASTENERS:

A. HARDNESS TESTS

I. HARDNESS TESTS SHALL BE PERFORMED PER ASTM E-18, ROCKWELL C SCALE

(HRC) ON FASTENERS IN THE HEAT TREATED CONDITION. TEST METHODS OTHER

THAN ROCKWELL C ARE NOT PERMITTED WITHOUT PRIOR APPROVAL OF NFPC.

II. THREE HRC READINGS SHALL BE TAKEN AT EACH END AND AVERAGED. READINGS

ON THE POINT END SHALL BE TAKEN AT ½ RADIUS. ANY THREE LOCATIONS ON THE

HEAD END ARE ACCEPTABLE. THE ACCEPTABLE RANGE FOR AVERAGE VALUES IS

HRC 25-35. INDIVIDUAL READINGS ARE NOT TOLERANCED.

III. THE AVERAGED READINGS FROM EACH END OF EACH FASTENER SHALL BE

REPORTED; HOWEVER RESULTS DO NOT NEED TO BE IDENTIFIED TO SPECIFIC

PIECES.

B. LIQUID PENETRANT INSPECTION (PT)

I. PT SHALL BE CONDUCTED ON EACH ITEM PER MIL-DTL-1222J (SECTION 4.3.3,

METHODS PER NAVSEA T9074-AS-GIB-010/271), WITH THE FOLLOWING ADDITIONS

AND EXCEPTIONS:

1. NO CRACKS ARE ACCEPTABLE ON THE HEX SOCKET OPENING.

2. EXCEPT AS NOTED ABOVE PT ACCEPTANCE CRITERIA IS PER ASTM

F788/F788M WITH SUPPLEMENTARY INSPECTION S1.

II. PT RESULTS SHALL BE DOCUMENTED IN THE CERTIFICATION REPORT. THE RESULTS

FROM EACH FASTENER SHALL BE REPORTED, HOWEVER RESULTS DO NOT NEED TO

BE IDENTIFIED TO SPECIFIC PIECES.

C. IN ADDITION TO THE FASTENER MARKING REQUIREMENTS OF MIL-DTL-1222J, EACH PIECE

SHALL BE STAMPED WITH THE MANUFACTURING LOT NUMBER ON THE POINT END AS

CERTIFICATION OF ACCEPTABILITY OF THE ABOVE HARDNESS AND PT TESTS.

10) MIL-DTL-1222J REQUIRES AXIAL TENSILE STRENGTH AND YIELD STRENGH OF GRADE 500 STUDS.

ONLY THE SAMPLE SIZED REQUIRED BY MIL-DTL-1222J TABLES XI AND XII (PLAN C) ARE REQUIRED TO BE TESTED. THE FOLLOWING IS CLARIFICATION OF THE REQUIREMENTS FOR THESE PARTICULAR

STUDS:

A. FINISHED STUDS ARE REQUIRED TO BE AXIAL TESTED IAW MIL-DTL-1222J SECTION 4.5.2.4 (METHOD 1 PER ASTM F606). THE LOAD FOR THE TEST IS 130-180KSI AS SPECIFIED IN TABLE

II (PAGE 31) OF MIL-DTL-1222J. THIS IS A DESTRUCTIVE TEST AND PARTS MAY NOT BE

REWORKED AND SUPPLIED TO NFPC.

B. YIELD STRENGTH TESTS ARE REQUIRED IAW MIL-DTL-1222J SECTION 4.5.2.4 (METHOD 2 OR

2A OF ASTM F606). BAR STOCK MAY BE USED FOR THIS TEST IAW MIL-DTL-1222J SECTION

4.5.2.7 PROVIDED THE PROVISIONS ARE MET (SAME LOT, STARTING STOCK IS 2.5” DIAMETER

OR LESS AND THE AXIAL TENSILE STRENGTH TEST IS COMPLETED SATISFACTORY).

11) ALL STUDS SHALL BE WRAPPED INDIVIDUALLY IN POLYETHYLENE MESH SLEEVES (ULINE PN S-6580

OR EQ) AND PACKAGED TOGETHER SECURELY IN A COVERED WOODEN CRATE PER ASTM D7478,

TYPE I, CLASS 2, STYLE A, WITH A SCREWED DETACHABLE TOP. STUDS SHALL BE PACKAGED SUCH

THAT CONTACT BETWEEN STUDS DURING SHIPMENT IS NOT POSSIBLE.

SIZE CODE IDENT: NFPC DRAWING NO. REV

A

CODE

SCALE: None SHEET 3 OF 4

12) CERTIFICATE OF CONFORMANCE IS REQUIRED FOR ACCEPTANCE. ADDITIONALLY THE VENDOR SHALL PROVIDE THE FOLLOWING MATERIAL CERTIFICATIONS FOR EACH UNIQUE HEAT OR LOT USED TO MANUFACTURE THESE SCREWS. MISSING OR INCOMPLETE CERTIFICATIONS MAY BE CAUSE FOR REJECTION OF THE ORDER. EACH CERTIFICATION SHALL INCLUDE THE HEAT OR LOT NUMBER FOR TRACEABILITY, BE ON COMPANY LETTERHEAD AND INCLUDE THE NAME, TITLE AND SIGNATURE OF

THE CERTIFYING OFFICIAL.

A. BAR STOCK MATERIAL CERTIFICATION INCLUDING RESULTS OF CHEMICAL AND MECHANICAL

TESTS PER QQ-N-286G.

B. RESULTS OF THE SLOW STRAIN RATE TEST (SSRT) REQUIRED BY QQ-N-286G. NOTE: ONLY

THOSE VENDORS LISTED IN NOTE 1 ARE ACCEPTABLE.

C. RESULTS OF THE TORQUE TESTING PER MIL-F-18240 REV E OR LATER IN ACCORDANCE

WITH NOTE 7.

D. RESULTS OF SEPARATE CHEMICAL INSPECTION IN ACCORDANCE WITH NOTE 8.

E. RESULTS OF DIMENSIONAL INSPECTION REQUIRED BY MIL-DTL-1222J (SAMPLING PLAN A

PER TABLE XII OF THE 7 CHARACTERISTICS IN TABLE XIV).

F. RESULTS OF THE HARDNESS TEST (FOR EACH FASTENER) AS SPECIFIED IN NOTE 9.A.

G. RESULTS OF THE PT INSPECTION (FOR EACH FASTENER) AS SPECIFIED IN NOTE 9.B.

H. RESULTS OF THE AXIAL TENSILE STRENGTH AND YIELD STRENGTH TESTS AS SPECIFIED IN

NOTES 10.A AND 10.B.

SCALE: None SHEET 4 OF 4

NOTE 9.C MARKING

LOCATION

MARKING LOCATION FOR MATERIAL

SYMBOL (K), MANUFACTURER’S SYMBOL

AND THE LOT NUMBER (PER MIL-DTL-1222J

SECTION 3.13.1).

REVISIONS
A
B
C
1
NAVSEA Tech Pub, Requirements for Non-Destructive Testing Methods
UNITS AND TOLERANCES
C
SCALE: None
SHEET 1 OF 5
C
C
C
C
PCI1856-E1 Rev B.PDF
REVISIONS
A
B
UNITS AND TOLERANCES
B
SCALE: None
SHEET 1 OF 4
B
B
B