5 November 2019

W56HZV-19-R-0059 – Technical Information Questionnaire (TIQ) Lightweight Multipurpose Shelters (LMS) Type I, III, V

Company:________________________________ Cage Code:_______________________ POC: ____________________________________ POC Telephone:___________________ POC Email:_______________________________

The following TIQ is intended to support the Government’s determination whether the proposed LMS is technically acceptable and is capable of meeting the performance requirements outlined in the Solicitation. The proposer’s failure to answer each of the questions in this TIQ and submit substantiating data may result in the rejection of the proposal. Every question must be supported with substantiating data as detailed in RFP Section L.4.1.2 and below. The product offered must meet ALL of the capabilities and requirements as described in the Item Description (Section C – Description/Specifications/Work Statement) and specification ASTM E2377-18 (Standard Specification for Shelter, Electrical Equipment, Lightweight) for the LMS Type I, III, V.

Please answer every question below indicating via an “X” in the “Yes” or “No” column. Substantiating data shall also be attached to this completed TIQ. The substantiating data for questions shall be in the form listed in the column titled “Verification”.

Vendor Response

It e m

Evaluation Question

R e fe re n ce

A

ST

M

E

Sp e ci fi ca ti o n

S co p e o f

W o rk

Verification Yes No

Proposal Location of Substantiating

Data

Does your shelter meet the configuration constraints specified on interface drawing 17-2-0035 for the Type I and

Type III LMS?

ASTM E2377-18

(Section 3.2.3)

Provide Technical Drawing

Does your shelter conform to the dimensions stipulated in

ASTM E2377-18 Section 3.2.3.2 for the LMS Type I and Type III?

ASTM E2377-18

(Section 3.2.3.2)

Provide

Does your shelter meet the configuration constraints specified on interface drawing 17-2-0035-DDE for the Type V

LMS?

Section C – Scope of Work (SOW) &

Attachment 0003

Provide

Does your shelter for the Type I and Type III provide the minimum shielding effectiveness prescribed by

Specification E1925, Fig. 1, in any location of the shelter over the frequency range of 150 kHz to 10 Ghz in ASTM E2377-18?

ASTM E2377-18

(Section 3.3.2)

Provided Certified Engineer Analysis

Does your shelter meet the weight and payload capacity for the Type I and Type III LMS listed in Table 1 of the ASTM E2377-18 and for the Type V listed in section C 2.2.2?

ASTM E2377-18

(Section 3.2.1)

& SOW C.2.2.2 –

Section 3.2.1

Provided Certified

Does your shelter dismounted, with payload (see 3.2.1) withstand flat and rotational drops from 6 in. (15 cm) without structural damage, permanent deformation, or degradation for all variants for the LMS. The shelter shall also be capable of being placed on an unimproved surface without structural damage, permanent deformation, or degradation?

ASTM E2377-18

(Section 3.4.6)

Provided Certified

Can your shelter meet the lifting and tie down provisions requirements of interface standard MIL-STD-209 for all variants of the LMS?

ASTM E2377-18

(Section 3.4.7)

Provided Certified

Your dismounted shelter for all variants (using the M1152A1 with B2 Armor Kit HMMWV), with a simulated payload (see

3.2.1), shall: (1) meet the Gabarit International de

Chargement (GIC) equipment gauge envelope as defined in interface standard MILSTD-

1366, and (2) shall be capable of withstanding multiple rail impacts without damage or degradation to the shelter or shelter/vehicle combination, and without damage to the tie down cables, or blocking or bracing, (see 4.4.1)?

ASTM E2377-18

(Section 3.4.1)

Provided Certified

Your shelter/vehicle combination, with payload (see 3.2.1), mounted on an M1152A1 with B2 Armor Kit HMMWV, shall be capable of being driven over road courses as defined by the

Perryman, Churchville, and Munson courses found at

Aberdeen Proving Ground, ASTM E2377-18

(Section 3.4.4)

Provided Certified

Maryland, without damage or degradation to the shelter, or damage or degradation to the vehicle, caused by the shelter.

The shelter/vehicle combination shall meet U.S.

and NATO countries highway legal limits for all variants.

Can you prepare a Maintenance allocation Chart (MAC) in accordance with MIL-STD

40051-2C?

Section C – SOW C.2.4.7.6

Provide Sample MAC for LMS subassembly with data populated

Can you prepare a Provisioning Parts List (PPL)?

Reference(s): Provisioning Statement of Work (SOW) Data

Item Description (DI-SESS- 81874)?

Section C – SOW C.2.4.7.4

Provide Sample PPL for LMS subassembly with Data Populated

Can you prepare an Engineering Data For Provisioning (EDFP) requiring the part to be able to be reasonably identifiable through data such as: Physical Characteristics, Performance

Date and/or Specification Data?

Reference(s): MIL-STD-40051-

2C?

Section C – SOW C.2.4.7.5

Provide sample EDFP for LMS subassembly with Data Populated

Can you provide a Shelter to

HMMWV Mounting Kit as required by Section C?

Section C – SOW C.2.4.5.1

Provide

Can you provided a Pintle Extension Kit which can be separately boxed and stored inside the shelter as required by ASTM E2377-18 Drawing 17-1-

8565?

Section C – SOW C.2.1

Provide