Quotation Reference: NYANG-0712-GuardHouse Page 1 of 2

Empire Tech Solutions, Inc.

1151 Pittsford-Victor Rd.

Pittsford, NY14534

Phone: 585-924-8980 Fax: 585-924-8994 Email: sales@empire-tech.net

Date: July 12, 2018

To: NYANG Phone:

Attn: Email:

RE: Ballistic Guard House 10’6” wide X 20’ long X 8’ High, UL752 Level 5

Prefabricated Building:

➢ UL 752 Level 5 Elements

• All material used for exterior walls: ¼” certified steel plates, UL752 Level 5

• (2) 36” X 80” Bullet resistant UL 752 Level 5 solid sliding door, latch lock, weather stripping.

Door to be glazed with UL Level 5 clad polycarbonate glazing, tinted

• (5) UL 752 Level 5 bullet resistant windows tinted, and fixed glad polycarbonate glass mounted against ballistic walls, 36” tall.

• (1) UL 752 Level 5 AC shroud welded around the AC opening

➢ Other building elements:

• 3” structural steel tubing frame

• Insulation: R-18

• VCT flooring (color TBD)

• Exterior wall panels factory finish UL 752 Level 5 bullet resistant protection exterior face, 16 ga heavy duty steel interior, panels galvanized and mechanically fastened.

• Ceiling finish with 11-ga heavy duty steel, mechanically fastened to provide smooth flat interior

• Roof finish 11-ga heavy duty steel galvanized and welded to provide smooth flat exterior if acceptable for aesthetic exterior.

• (2) camera mounts. Cameras by others

• (1) 18” overhangs on doorways

➢ Electrical/HVAC

• Electrical package consists of 12-ga minimum copper wiring in 1/2” EMT surface mounted conduit and attached to surface mounted 2x4 boxes

• (2) single pole switches wired

• (6) 115V duple receptacles, wired

• (1) 220V outlet

• (1) 12 Amp 12 space circuit breaker box with 4 circuits

• (4) T8 fluorescent light fixtures, wired

• (6) Exterior floodlights with switch

• (3) data ports wired mailto:justin.d.goerss.mil@mail.mil

Quotation Reference: NYANG-0712-GuardHouse Page 2 of 2

• (1) Wall mounted HVAC unit, 18,000BTU cooling and 16,000 BTU heating with ballistics shroud

➢ Other:

• Welding Certifications: Ebtech Industrial is one of only a few companies that have achieved certification to the latest U.S. Army TARDEC/TACOM specification for ballistics welding. Processed and materials are tracked and verified to the US Army TARDEC/TACOM specification for testing and quality to insure both traceability and quality for the work performed.

• Factory Installed electrical

• Building ships assembled

• Estimated weight: 18,650lbs

Optional Equipment:

➢ Bathroom

• (1) Toilet

• (1) Sink

• (1) Exhaust vent

• (1) light

• (1) door

• Plumbing installed to exterior connection points for external hook-ups on-site

Delivery: 4-6 weeks after receipt of signed approval drawings. Allow 1-2 weeks for drawing generation Freight: Not Included, FOB Ship Point Connellsville, PA Terms:

• 15% Due with purchase order

• 30% due on receipt of signed approvals

• Remainder Net 30 days upon shipment Exclusions:

➢ State, local, sales or use taxes are the responsibility of the buyer

➢ Applicable permits, Freight, Unloading, Foundations, Installation, Utilities, Furniture, Furnishings

Ebtech GSA Contract Number: GS-07F-0647W. Renewal Date: September 2020

Valid for 90 days

Prepared by: Mike Bartle Cell: (585) 339-8166 Email: mike@empire-tech.net mailto:mike@empire-tech.net

Ref: 0 July 12, 2018

NYANG Guard House 10'6" X 20' X 8'

CONFIDENTIAL PROPERTY OF EMPIRE TECH SOLUTIONS

General reference only. Right reserved to make changes without notice. 1

PAGE

Mike Bartle 1151 Pittsford-Victor Road

Pittsford, NY 14534

(585) 924-8980 mike@empire-tech.net

Ref: 0 July 12, 2018

NYANG Guard House 10'6" X 20' X 8'

CONFIDENTIAL PROPERTY OF EMPIRE TECH SOLUTIONS

General reference only. Right reserved to make changes without notice. 2

PAGE

Mike Bartle 1151 Pittsford-Victor Road

Pittsford, NY 14534

(585) 924-8980 mike@empire-tech.net

NYANG-0712-GuardHouse.pdf
NYANG-GUARDHOUSE-LAYOUT.pdf

File details come from the government source that posted it. Updated .