Quotation Reference: NYANG-0712-GuardHouse Page 1 of 2
Empire Tech Solutions, Inc.
1151 Pittsford-Victor Rd.
Pittsford, NY14534
Phone: 585-924-8980 Fax: 585-924-8994 Email: sales@empire-tech.net
Date: July 12, 2018
To: NYANG Phone:
Attn: Email:
RE: Ballistic Guard House 10’6” wide X 20’ long X 8’ High, UL752 Level 5
Prefabricated Building:
➢ UL 752 Level 5 Elements
• All material used for exterior walls: ¼” certified steel plates, UL752 Level 5
• (2) 36” X 80” Bullet resistant UL 752 Level 5 solid sliding door, latch lock, weather stripping.
Door to be glazed with UL Level 5 clad polycarbonate glazing, tinted
• (5) UL 752 Level 5 bullet resistant windows tinted, and fixed glad polycarbonate glass mounted against ballistic walls, 36” tall.
• (1) UL 752 Level 5 AC shroud welded around the AC opening
➢ Other building elements:
• 3” structural steel tubing frame
• Insulation: R-18
• VCT flooring (color TBD)
• Exterior wall panels factory finish UL 752 Level 5 bullet resistant protection exterior face, 16 ga heavy duty steel interior, panels galvanized and mechanically fastened.
• Ceiling finish with 11-ga heavy duty steel, mechanically fastened to provide smooth flat interior
• Roof finish 11-ga heavy duty steel galvanized and welded to provide smooth flat exterior if acceptable for aesthetic exterior.
• (2) camera mounts. Cameras by others
• (1) 18” overhangs on doorways
➢ Electrical/HVAC
• Electrical package consists of 12-ga minimum copper wiring in 1/2” EMT surface mounted conduit and attached to surface mounted 2x4 boxes
• (2) single pole switches wired
• (6) 115V duple receptacles, wired
• (1) 220V outlet
• (1) 12 Amp 12 space circuit breaker box with 4 circuits
• (4) T8 fluorescent light fixtures, wired
• (6) Exterior floodlights with switch
• (3) data ports wired mailto:justin.d.goerss.mil@mail.mil
Quotation Reference: NYANG-0712-GuardHouse Page 2 of 2
• (1) Wall mounted HVAC unit, 18,000BTU cooling and 16,000 BTU heating with ballistics shroud
➢ Other:
• Welding Certifications: Ebtech Industrial is one of only a few companies that have achieved certification to the latest U.S. Army TARDEC/TACOM specification for ballistics welding. Processed and materials are tracked and verified to the US Army TARDEC/TACOM specification for testing and quality to insure both traceability and quality for the work performed.
• Factory Installed electrical
• Building ships assembled
• Estimated weight: 18,650lbs
Optional Equipment:
➢ Bathroom
• (1) Toilet
• (1) Sink
• (1) Exhaust vent
• (1) light
• (1) door
• Plumbing installed to exterior connection points for external hook-ups on-site
Delivery: 4-6 weeks after receipt of signed approval drawings. Allow 1-2 weeks for drawing generation Freight: Not Included, FOB Ship Point Connellsville, PA Terms:
• 15% Due with purchase order
• 30% due on receipt of signed approvals
• Remainder Net 30 days upon shipment Exclusions:
➢ State, local, sales or use taxes are the responsibility of the buyer
➢ Applicable permits, Freight, Unloading, Foundations, Installation, Utilities, Furniture, Furnishings
Ebtech GSA Contract Number: GS-07F-0647W. Renewal Date: September 2020
Valid for 90 days
Prepared by: Mike Bartle Cell: (585) 339-8166 Email: mike@empire-tech.net mailto:mike@empire-tech.net
Ref: 0 July 12, 2018
NYANG Guard House 10'6" X 20' X 8'
CONFIDENTIAL PROPERTY OF EMPIRE TECH SOLUTIONS
General reference only. Right reserved to make changes without notice. 1
PAGE
Mike Bartle 1151 Pittsford-Victor Road
Pittsford, NY 14534
(585) 924-8980 mike@empire-tech.net
Ref: 0 July 12, 2018
NYANG Guard House 10'6" X 20' X 8'
CONFIDENTIAL PROPERTY OF EMPIRE TECH SOLUTIONS
General reference only. Right reserved to make changes without notice. 2
PAGE
Mike Bartle 1151 Pittsford-Victor Road
Pittsford, NY 14534
(585) 924-8980 mike@empire-tech.net