Glass RFI_15 July 22.docx

DOCX document 15 KB Posted

Attached to
Ballistic Glass Federal contract opportunity
Solicitation number
W50S7Z-22-R-0013
Issued by
Department of the Army Louisiana Army National Guard

About this file

This document outlines requirements for a federal contract to replace ballistic glass at three buildings on a military facility. The scope of work involves replacing existing glass and framing with bullet resistant glazing designed to withstand a minimum of 0.3 PSI overhang pressure. While the glazing must meet DoD Minimum Antiterrorism Standards and UL 752 Level 5 ballistics ratings, it is not required to be fire rated or hurricane impact resistant. Finishes should match existing, with the transaction window at Building 41 specified as dark bronze. The solicitation was issued by the Department of the Army Louisiana Army National Guard for work to be completed within 120 days. Offers are due by July 13, 2022. The set-aside is for small businesses below $16.5M in size.

View the file

Other files for this federal contract opportunity

Other files attached to Ballistic Glass, newest first.
File Type Posted
EXHIBIT_C_Reference_Questionnaire_Package 18Jan18_NEW.docx DOCX document
EXHIBIT A.doc DOC document
B24 425 489 Bullet Resistant Glass - RFIs.docx DOCX document
Site Visit Sign in_Glass.pdf PDF
Solicitation_22-R-0013 Ballistic Glass.pdf PDF
4. SOW - B41, 425 B489 Bullet Resistant Glass.docx DOCX document
9. Attachments B41 B425 489 - Bullet Resistant Glass.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W50S7Z-22-R-0013 Buildings 41, 425, and 489 Ballistic Glass Request for Information

1. The Scope of Work describes the glazing as insulated, double pane, Level 5 bullet resistant, glass-clad polycarbonate but it does not discuss the performance characteristics of the framing that holds the glass. The framing will also need to be bullet resistant if they are truly trying to make the area bullet resistant. Furthermore, if the building materials that make up the walls surrounding these windows are not bullet resistant, the bullets can/will pass through the walls and injure the building occupants anyway. Do you want to just replace the glass, even if the materials surrounding it are not bullet resistant? (Assuming they aren't already).

Existing glass shall be replaced and new framing shall be bullet resistant.

2. The Scope of Work also indicated that all windows and doors must meet current rules and regulations, in accordance with applicable federal, state, and local regulations. The Scope of Work however did not mention “hurricane impact resistance” which is the current building code and is going to be an issue when it comes to Level 5 bullet resistant windows. The manufacturers can do one or the other – you can have a bullet resistant window or you can have a hurricane resistant window, but the window cannot be both hurricane AND bullet resistant. Due to being a military facility the local building codes may not apply. The current windows will need to have additional vertical mullions added to reduce the glass widths to meet hurricane impact resistance requirements if this is what we are to install. Please advise whether we are going to disregard the hurricane rating or not.

Windows shall be bullet resistant; disregard the hurricane rating.

3. Lastly, the SOW also states that the glazing shall meet a one hour fire rating, Class IV forced entry resistance, and sound insulation ratings. Due to the amount of performance requirements, we will be very hard pressed to find a manufacturer that can provide all of this with 1 product.

Glazing shall not be fire rated.

4. In addition to the ballistic requirements, the spec you sent over is listing UFC 4-01-01 DOD Minimum Antiterrorism Standards, which references blast resistance design criteria. We will need the peak pressure and impulse or a charge weight and standoff distance in order to begin quoting this as a blast rated project.

All glazing shall meet the UFC 4-010-01 DoD Minimum AT Standards plus the UL 752 Level 5 requirements. Glazing to be designed to be able to sustain .3 PSI minimum.

5. We’ll also need to know the required finish for all elevations and the door hardware that is being specified. It’s stating that the color will be determined through the submittal process; however, the cost from Clear or Dark Bronze Anodized to a painted finish is substantial. The transaction window at Bldg. 41 is to be Dark Bronze but will need confirmation on the other buildings.

Please match existing for finish and door hardware.