C10 - Interior Construction.pdf
PDF 2 MB Posted
- Attached to
- Facility Condition Assessments BUILDER Rev3 Federal contract opportunity
- Solicitation number
- W50S7E22Q0005
- Issued by
- Department of the Army National Guard
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site Visit Vendor List 20220411.pdf | ||
| B30 - Roofing.pdf | ||
| Question_Answer Document Ver2.pdf | ||
| D30 - HVAC.pdf | ||
| D20 - Plumbing.pdf | ||
| D50 - Facility Electrical.pdf | ||
| B20 - Exterior Enclosure.pdf | ||
| D40 - Fire Protection.pdf | ||
| Site Visit QA Ver1.pdf | ||
| B01 W50S7E22Q0005 Facility Condition Assessment BUILDER_ Service_Combo Rev1.pdf | ||
| SMS Playbook Consolidated.pdf | ||
| B01 W50S7E22Q0005 Facility Condition Assessment BUILDER_ Service_Combo.pdf | ||
| B04 SCA Wage Determination 2015-4945.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix for Interior Construction (C10)
USAF Built Infrastructure Inventory and Assessments
Manual
This document includes information that shall not be disclosed outside the Government and shall not be duplicated, used or disclosed‐in whole or in part‐for any other purpose than the United States Air Force Built Infrastructure Assessment Program.
October 2021
2 | P a g e
Table of Contents I. Overview
A. C10 Interior Construction System description
1. UNIFORMAT II definition
2. Major components
3. Lifecycle characteristics
II. Inventory
A. General C10 Inventory Guidance
B. Inventory C1010 Partitions
C. Inventory C1020 Interior Doors
D. Inventory C1030 Fittings
III. Assessment
A. General C10 Assessment Guidance
B. Assessment C1010 Interior Partitions
C. Assessment C1020 Interior Doors
D. Assessment C1030 Fittings
IV. Inventory and Assessment Rules of Thumb
A. Assessor Qualifications
B. Year Installed
C. Inventory/Assessment
V. Inventory/Assessment Data Collection Sheet
VI. C10 UNIFORMAT II Minimum Component Reference Table
3 | P a g e
I. Overview This manual covers the inventory and assessment process for building “Interior Construction (C10)” building system and components. Please see the SMS Playbook Manual for additional information including:
• BUILDERTM Sustainment Management System Concepts
• Overview of ASTM E 1557 UNIFORMAT II Standard Classification for BUILDERTM
• BUILDERTM Inventory Overview
• BUILDERTM Assessment Overview
• BUILDERTM Remote Entry Database (BREDTM)
• Working with Web‐Based BUILDERTM
• Quality Assurance
• Site Visit Preparation and Execution
• Site Visit Safety
A. C10 Interior Construction System description
1. UNIFORMAT II definition
• The interior construction system of a building facilitates space definition, separation, security, observation, functionality and environmental control within the building. The system is designed to support the function/mission of the building and for the comfort and safety of the occupants.
2. Major components
• Partitions (C1010) – Partitions include interior walls constructed from different types of materials (typically drywall, masonry, wood or plaster) and windows used to divide the interior space to meet the needs of the occupants.
• Interior Doors (C1020): Interior doors allow access, environmental control and security for both personnel and non‐personnel needs.
• Fittings (C1030): Fittings are a collection of interior components including counters, lockers, ladders, display boards, etc. For the USAF BUILDERTM SMS program “Interior Ladders” are the only C1030 fittings component that may be inventoried and assessed. Inventory and assessment of Interior Ladders is at the option of the base.
3. Lifecycle characteristics
• The life cycle for Interior Construction varies based on material type/quality, amount of use and care over the life cycle. Typically finish materials are short‐lived components and the life cycle is based on the manufacturers’ standard life of the product. These systems have an expected service life of 7 – 40 years.
II. Inventory A. General C10 Inventory Guidance
This section presents common UNIFORMAT II C10 Interior Construction inventory Component Sections found across USAF installations as a guide for entering into the BUILDERTM SMS or BREDTM software. Inventory items are arranged by BUILDERTM SMS system with Material Category, Component Subtype, Quantity and Inventory Notes. Each building’s full or partial inventory can be captured in the field using the Inventory/Assessment
4 | P a g e
Data Collection Sheet(s) included in Section V and in the AFCEC BUILDER SharePoint Site Documents Library.
Section VI (C10 UNIFORMAT II Minimum Component Reference Table) provides a complete listing of the minimum components inventoried and assessed for C10. Bases may elect to inventory and assess additional components.
NOTE: Bases may elect to inventory and assess other facility interior construction Component Sections.
C10 Inventory and assessment is required by the current AFCAMP Playbook (Business Rules) as project support documentation for consideration in the project prioritization process. All components however, included in the project Statement of Work require inventory and condition assessment.
Component Subtypes General, Other, and Unknown require a Section Name to identify the Component Sections. Include additional information in Inventory Comments if required to further describe the Component Sections.
It is critical to confirm the year installed (default from Real Property Assets Database (RPAD)) or determine the year installed. BUILDERTM SMS uses the Install Date, life cycle degradation curves and assessment observations to establish a Condition Index (CI) for each Component Section. If the assessor suspects the RPAD default date is not accurate or an addition or renovation has taken place, check the RPAD record for year renovated or check local as‐built or renovation drawings to help determine the year installed. Estimated Install Dates decrease the Expected Service Life significantly. Every effort should be made to establish an Install Date and avoid the use of estimated.
If this is an initial assessment and no interior construction inventory has previously been entered into BUILDERTM SMS, an inventory is required. Interior construction components inventoried for USAF buildings are usually visible. When interior construction components are not visible, as‐built drawings should be used to identify and quantify the interior construction components. If as‐built drawings are not available, the assessor may use experience to make an assumption for the interior construction types and quantities based on similar construction, consultation with local staff and other resources such as www.inspectapedia.com.
The remainder of this section provides photo examples of the most common USAF interior construction inventory items categorized by major components, and accompanied with the appropriate Material Category, Component Subtype and Quantity from the BREDTM drop down menus. This information is supplemented with general and photo specific inventory hints as a guide for data entry by the assessor.
General Interior Construction C10 Inventory Hints
• Interior wall inventory is to be captured in C1010 – Interior Partitions. Only coverings or finishes of interior walls are captured with C30 ‐ Interior Wall Finishes for some facilities.
• Inventory Comments should be recorded to clarify inventory component description if Section Name is insufficient.
http://www.inspectapedia.com/
5 | P a g e
B. Inventory C1010 Interior Partitions Typical interior partitions on USAF bases are:
1. Material Category: C101001 Fixed Partitions
Component Subtype: Wall – Concrete Block
Quantity: SF Year Built/Renewed: RPAD
Painted/Coated: Yes
Inventory Notes: N/A
Load Bearing:
Fire Rated:
2. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
EA Year Built/Renewed: RPAD
Inventory Notes:
Awning windows open outward and give the appearance of an awning Quantity shown is 3 EA Metal refers to the frame material Section Name: Awning Window –Metal Fire Rated
3. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
EA Year Built/Renewed: RPAD
Inventory Notes:
Window is “Fixed” and does not open Metal refers to the frame material Section Name: Fixed Window – Metal Fire Rated:
6 | P a g e
4. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
EA Year Built/Renewed: RPAD
Inventory Notes:
Hopper windows open outward from bottom and give appearance of a hopper Metal refers to the frame material Section Name: Hopper Window – Metal ADA Clearance ( 4”) into corridor Fire Rating
5. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
EA Year Built/Renewed: RPAD
Inventory Notes:
Section Name: Security Type – Metal frame Fire Rated ADA Compliance:
( 36” AFF )
6. Material Category: C101005 Interior Windows
EA Year Built/Renewed: RPAD
Inventory Notes:
Quantity shown is 2 each Section Name: Single Hung Window – Metal Fire Rated
7 | P a g e
7. Material Category: C101005 Interior Windows
EA Year Built/Renewed: RPAD
Inventory Notes:
Although there are 2 glass lights, the sliding window is counted as 1 EA.
Section Name: Sliding Window ‐ Metal
8. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Although there are 12 glass lights, the window is counted as 1 EA.
This is an exterior window, interior is similar Section Name: Double Hung Window ‐ Wood
9. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Section Name: Fixed ‐ Wood
10. Material Category: C101005 Interior Windows
Component Subtype: Interior Windows
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
This is an exterior window, interior is similar Section Name: Single Hung ‐ Wood
8 | P a g e
C. Inventory C1020 Interior Doors Typical interior doors on USAF bases are:
11. Material Category: C101005 Interior Windows
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Section Name: Motorized Ceiling Grille – Metal Fire Rating:
Fusible‐Link sensor:
1 . Material Category: C102004 Sliding & Folding Doors
Component Subtype: General
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Folding partitions and Bi‐fold doors are counted as 1 EA.
Section Name: Folding Partition Door – Vinyl Section Name required
2. Material Category: None
Component Subtype: Access Hatch
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Roof hatch inventoried under B30 Roofing if goes to roof and not space Inventory and assessment optional Fire rated Ladder access
9 | P a g e
3. Material Category: C102003 Fire Doors
Component Subtype: Fire – Swinging, Metal
Quantity EAYear Built/Renewed: RPAD
Painted/Coated: Yes/No
Inventory Notes:
Should have fire rated label on inside edge May be held open by magnetic “hold open” device Double door counted as 2 doors Sensor‐Release UL Rating‐Hardware:
4. Material Category: C102001 Standard Interior Doors
Component Subtype: General
Quantity EAYear Built/Renewed: RPAD
Inventory Notes: N/A These double doors would be counted as 2 EA.
Section Name: Louver Metal Doors Section Name required
5. Material Category: C102005 Interior Overhead
Component Subtype: Metal
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Manual & motorized are captured separately Section Name: Manual Overhead Door Fire Rating:
Code Compliance Pedestrian Door Near:
10 | P a g e
6. Material Category: C102001 Standard Interior
Component Subtype: Metal Door
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
These double doors would be counted as 2 EA
7. Material Category: C102090 Interior Specialty Doors
Component Subtype: Other
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Section Name: Vault Door
Section Name required
8. Material Category: C102001 Standard Interior Doors
Component Subtype: Wood Door/Wood Frame
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Although multiple leafs, door unit is counted as 1 door Section Name: Bi‐fold Door
11 | P a g e
9. Material Category: C102001 Standard Interior
Component Subtype: Wood Door/Wood Frame
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
2 sections of Dutch door are counted as 1 door Section Name: Dutch Door – Wood ADA compliance 36” ADA on Counter
10. Material Category: C102001 Standard Interior Doors
Component Subtype: Wood Door/Wood Frame
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Double doors are counted as 2 EA Section Name: Louvered Door
11. Material Category: C102001 Standard Interior Doors
Component Subtype: Wood Door/Metal Frame
Quantity EAYear Built/Renewed: RPAD
Inventory Notes: N/A
12 | P a g e
12. Material Category: C102004 Sliding & Folding Doors
Component Subtype: General
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Sliding door units are counted as 1 EA.
Section Name: Sliding Wood Doors Section Name required
13. Material Category: None
Component Subtype: Transom
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Transoms can be over or beside door Other materials include metal and glass Not inventoried or assessed Fire‐Rated:
14. Material Category: C102091 Other Interior Personnel Doors
Component Subtype: General
Quantity EAYear Built/Renewed: RPAD
Inventory Notes:
Double doors are counted as 2 EA Do not count door glass as windows Section Name: Fiberglass Reinforced Plastic
Section Name required
13 | P a g e
D. Inventory C1030 Fittings For the USAF BUILDERTM SMS program, Interior Ladders are the only C1030 fitting that may be inventoried and assessed. C1030 inventory and assessment is not mandatory but may be at a base’s option.
III. Assessment A. General C10 Assessment Guidance
Interior construction component sections are assessed using Direct Condition Rating (DCR). Usually interior construction components will be visible. When Component Sections are not visible, assessment is based on operability or serviceability (work history).
When interior construction component sections are visible, they should be assessed. The on‐site assessment is determined based on the assessor’s observations compared to the Direct Condition Rating (DCR) Definitions chart for major components C1010, C1020 and C1030. The “Rating” reflects observed deterioration, impact on operability, serviceability (work history) and repair requirements based on the chart below and the assessor’s professional judgment. When determining the rating, the assessor should consider the quantity and severity of conditions or distresses observed. The assessor must provide an Inspection Comment in cases of Amber+ or lower DCR or BUILDERTM calculated Distress Survey rating. It is recommended that photographs
15. Material Category: C102004 Sliding & Folding Doors
Component Subtype: Other
Quantity EA Year Built/Renewed: RPAD
Inventory Notes:
Both Glass sidelights in a sliding door unit are counted as a single unit or 1
EA.
Section Name: Sliding Glass Doors Section Name required
1 . Equipment Category: Metal
Component Subtype: Interior Ladder
Quantity: LF Year Built/Renewed: Est.
Inventory Notes:
Note: Quantity is LF, include ladder and platform in estimate of total length Normally metal, wood ladders may also be entered under separate BREDTM dropdown Rails and cages are included in inventory OSHA’s Fixed ladder Code‐20’‐0” feet:
14 | P a g e documenting defects to be taken and attached to the assessment.
Note: If no assessment is entered into BUILDERTM SMS and the section appears original to the facility, the install date is the facility construction date, otherwise the install date is based on the best data available to the assessor. Assessment currency will be calculated based on either the installation date or the most recent assessment date of the section.
Under no circumstances should age be factored into a DCR or Distress Survey assessment. Ratings are based on condition, operability and/or serviceability only. BUILDERTM SMS already factors in the age when calculating Condition Index (CI).
The following conditions or events can accelerate interior construction deterioration and should be considered by the assessor:
• Moisture damage due to roof or pipe leaks
• Damage due to personnel or equipment
• Improper construction or installation
• Neglected maintenance
• OSHA requirement of 7’‐6” ceiling and no projections less than 6’‐8”
( Example exit‐lights)
If observed, the assessor must consider the severity and density of these conditions to determine the DCR provided by the following DCR chart.
The assessor must provide an Inspection Comment for any Amber+ or lower DCR or BUILDERTM calculated Distress Survey rating. Unless the condition is based on serviceability, compliance, or a condition that cannot be visually documented, photograph documentation is highly recommended to be attached to the assessment.
When there is visible deterioration or defects of a system/component, a picture provides a lot of value. When accomplishing the 5‐year reassessment, especially when it is a different assessor, the assessor can compare the then to now. Even if it is the same assessor sees a particular asset frequently (possibly yearly during annual PM), the assessor may not notice the gradual degradation so a picture provides great value. Please consult local ISSO for correct procedures on taking pictures, reviewing picture content and transferring data to AFNET to ensure INFOSEC, COMSEC, OPSEC compliance.
Following the BUILDERTM SMS assessment, the assessor should inform the facility manager of any new issues discovered.
NOTE: Red highlighted text is provided as an example of a lifecycle of typical components and should be adjusted as needed to represent other various components.
Direct Condition Rating (DCR) Definitions
Rating Observation Green (+) Fully Operational ‐ Free of Known or Observable Defects
Keep doing PM required to maintain warranty ‐ no action required Green Fully Operational ‐ Slight Deterioration or Minimal wear
Keep doing PM ‐ no action required
15 | P a g e
Direct Condition Rating (DCR) Definitions
Rating Observation Green (‐) Fully Operational – Normal wear and/or serviceability defects
Keep doing PM ‐ need to start planning for rehabilitation
Amber (+) Reduced Operation – Minor wear and/or serviceability defects Repairs could be accomplished and replacement planned within next eight to ten years (Investment of resources could extend life)
Amber Reduced Operation – Moderate wear and/or serviceability defects Repairs could be accomplished and replacement planned within next six to seven years (Investment of resources could extend life)
Amber (‐) Reduced Operation – Significant wear and/or serviceability defects Repairs could be accomplished and replacement planned within next three to five years (Investment of resources could extend life)
Red (+) Loss of Operation – Moderate wear and/or serviceability failure Repairs could be accomplished and replacement planned within next two years (Run to failure ‐ further investment unwise)
Red Loss of Operation – Significant wear and/or serviceability failure Repairs could be accomplished and replacement planned within the next year (Run to failure ‐ further investment unwise)
Red (‐) Loss of Operation – Complete wear and/or serviceability failure Replacement needs to be planned immediately
BUILDERTM SMS provides the ability for the assessor to rate component painted or coated surfaces. Some interior components include manufacturer (or factory) finishes. These finishes tend to age consistent with the components. Other components have local or field applied paints or coatings. The DCR Definitions ‐ Coatings chart below should be used by the assessor to rate non‐ manufacturer applied coatings. This chart should be used to rate coatings for:
• Interior & exterior walls
• Window frames
• Doors
• Drywall finish
• Concrete & CMU wall finishes
• Hazardous Material (Wall and Flooring )
The assessor should match actual coating observations listed in the charts, below, and apply the corresponding “Rating.” Do not forget to check the “paint box” in BREDTM.
Direct Condition Rating (DCR) Definitions ‐ Coatings
Green (+) Perfect condition. No visible deterioration.
Green Little visible deterioration.
Green (‐) Some visible deterioration.
Amber (+) Minor visible deterioration.
16 | P a g e
Direct Condition Rating (DCR) Definitions ‐ Coatings
Amber Moderate visible deterioration.
Amber (‐) Major visible deterioration.
Red (+) Significant visible deterioration.
Red Severe visible deterioration.
Red (‐) Complete deterioration.
B. Assessment C1010 Interior Partitions
Below are assessment hint questions to help the assessor determine the most appropriate DCR and examples of common distresses.
17 | P a g e
Examples of typical toilet partition distresses or conditions include:
C1010 Assessment Hint Questions
• What distresses or problems are observed?
• What is the quantity and severity of the distresses?
• Do operable windows operate and secure properly?
• What is the service/repair history of the component?
• Is there a compliance issue? Refer to the BUILDERTM Direct Condition Rating
Matrix for DCR.
• Will repairs preserve or extend the remaining service life of the partition?
Based on above:
• Select a DCR from the chart.
• If assessment rating is Amber + or below, enter an Inspection Comment to describe the reason. Unless the condition is based on operability, serviceability, compliance, or condition cannot be visually documented, photograph documentation of defect(s) is highly recommended to be attached to the assessment.
• An Inspection Comment should also be entered regardless of DCR, if a significant localized issue needs to be highlighted, which may not necessarily impact the overall Component Section DCR.
1. Typical Distress:
Picture is of a typical masonry toilet partition.
Common distresses or conditions include, but are not limited to:
Damaged CMU block Mortar joint deterioration due to exposure to moisture Paint deterioration due to exposure to moisture
2. Typical Distress:
Picture is of a typical metal toilet unit. Common distresses or conditions include, but are not limited to:
Broken wall and/or floor anchors or doors Corroded floor anchors due to continuously wet floors.
Rust/corrosion due to exposure to moisture
18 | P a g e
C. Assessment C1020 Interior Doors Below are assessment hint questions to help the assessor determine the most appropriate DCR and examples of common distresses.
Examples of typical door distresses or conditions include:
C1020 Assessment Hint Questions
• What distresses or problems are observed?
• What is the quantity and severity of the distresses?
• Are doors damaged? Do they function and secure properly?
• What is the service/repair history of the component?
• Is there a compliance issue? Refer to the BUILDERTM Direct Condition Rating
Matrix for DCR.
• Will repairs preserve or extend the remaining service life of the door?
Based on above:
• Select a DCR from the chart.
• If assessment rating is Amber + or below, enter an Inspection Comment to describe the condition. Unless the condition is based on operability, serviceability, compliance, or condition cannot be visually documented, photograph documentation of defect(s) is highly recommended to be attached to the assessment.
• An Inspection Comment should also be entered regardless of DCR, if a significant localized issue needs to be highlighted, which may not necessarily impact the overall Component Section DCR.
1. Typical Distress: Damaged
2. Typical Distress:
19 | P a g e
D. Assessment C1030 Fittings Below are assessment hint questions to help the assessor determine the most appropriate DCR and examples of common distresses.
Examples of typical ladder distresses or conditions include:
IV. Inventory and Assessment Rules of Thumb A. Assessor Qualifications
• The architectural/structural assessor should have a combination of 8+ years of general building construction, facilities maintenance and planning/estimating experience related to building foundations, structure, enclosure and interior construction and be
C1030 Assessment Hint Questions
• What distresses or problems are observed?
• What is the quantity and severity of the distresses?
• Is ladder damaged?
• What is the service/repair history of the component?
• Is there a compliance issue? Refer to the BUILDERTM Direct Condition Rating
Matrix for DCR.
• Will repairs preserve or extend the remaining service life of the ladder?
Based on above:
• Select a DCR from the chart.
• If assessment rating is Amber + or below, enter an Inspection Comment to describe the reason. Unless the condition is based on operability, serviceability, compliance, or condition cannot be visually documented, photograph documentation of defect(s) is highly recommended to be attached to the assessment.
• An Inspection Comment should also be entered regardless of DCR, if a significant localized issue needs to be highlighted, which may not necessarily impact the overall Component Section DCR.
Typical Distress:
Although the ladder to the right shows no distresses, common distresses are:
Loose or broken bolt connections at floor or wall.
Damaged rungs or vertical supports from vehicle traffic (in shops)
Rust Damage to safety rail or cage Missing/damaged safety climb components
20 | P a g e equivalent to a Journeyman, a V Level Technician, an Architect or Civil Engineer. The assessor should have a working knowledge of the ASTM E 1557 Standard Classification for Building Elements UNIFORMAT II and a basic understanding of other building systems such as HVAC, Plumbing, Fire Protection and Electrical. The assessor should be able to identify common building materials, techniques and structural/architectural system types/elements, be proficient at reading drawings and engineering reports and have experience identifying common problems related to architectural/structural systems.
The lead architectural/structural assessor may be supported by less experienced staff during the inventory and assessment.
B. Year Installed
• In some cases interior construction sections may be replaced as an individual repair or partial replacement. These areas would have a different age. The RPAD construction and renovation dates should be confirmed. If they are not appropriate, the interior construction age must be estimated. The building occupants or other facilities staff may be able to provide some information.
• If construction drawings or As‐Builts are available, look for date published to assist with determining age of materials.
• Additions, new wings or major renovations likely require identifying a separate Interior Partitions or Interior Doors sections with a different age.
• In the case of interior construction, the assessor must use judgment in sectioning interior partitions or doors. In large buildings with many interior partitions or doors, these components should be sectioned in the manner they are generally managed. If there are interior partitions or doors, a separate section for a single new interior partitions or doors is not necessary. However, if there are two major types or ages of interior partitions or doors then separate sectioning is a good idea.
• The year or date manufactured for interior doors may be visible on a label on the door edge (hinge side) in determining age.
• In some of the newer metal doors, the jamb in most cases will be stamped normally on the hinge side. For most types of doors look at the hinges ‐ are they a four barrel or a three barrel hinge? Most four barrel hinges are 1975 or older; most three barrel hinges are newer.
C. Inventory/Assessment
• Double doors are counted as 2 EA single doors.
• Transoms and sidelights on doors are entered as transoms with a note in the comments.
• If a sliding door and frame appears to be have been bought and installed pre‐hung, then the 2 door leaves are combined as 1 total unit, or 1 EA. If it appears the frame is a hollow metal or wood frame and 2 door leaves match all the other doors in the building, then count them as 2 doors, or 2 EA.
V. Inventory / Assessment Data Collection Sheet The following data collection form is included as a recommendation and may also be found in the AFCEC BUILDERTM SharePoint Site Documents Library. Construction drawings, floor plans, or digital device are commonly used. Use whatever collection method works best for the individual assessor/organization.
21 | P a g e
Architectural Inventory Sheet
22 | P a g e
Architectural Inventory Sheet
23 | P a g e
VI. C10 UNIFORMAT II Minimum Component Reference Table The following table provides SMS MINIMUM inventory and condition assessment requirements. The table effectively provides a list of WHAT will be inventoried, WHERE within the SMS the component inventory will reside and HOW a component is to be condition assessed. The structure of the list is within UNIFORMAT II to be consistent with BUILDERTM SMS. Currently all components are Direct condition assessed. Eventually, Distress assessments may be conducted on selective components.
PM Inspection/Testing Directive column gives information on any Air Force applicable publication providing Preventative Maintenance (PM) actions that, once conducted, provides information on a component's condition assessment. Preventive Maintenance Task Lists (PMTLs) or other inspections may be considered a Distress type assessment in the future for some components.
Condition assessment frequency is not to exceed 5 years. Condition assessments conducted as part of a PMTL may be entered into SMS but should not be more often than an annual assessment.
AMP reflects the AMP to which the component is assigned:
F: Facility AMP
C DEFINITION
Unf L1
Unf L2
Unf L3
WBS L4
Construction which takes place inside the exterior wall or exterior closure. The system does not include interior structural walls, which are included in B1010 FLOOR CONSTRUCTION and B1020 ROOF
CONSTRUCTION.
In Builder/ Fueler/ Paver/ Railer/ Utility
PM Inspection/ Testing Directive
Insp/ Assess Freq
SMS
Type Insp
Assessment Method
AMP/
Sub‐
AMP
C10 C1010
C101001 FIXED
PARTITIONS
Interior fixed partitions include metal or wood studs, sheetrock, masonry, and concrete walls. B N/A 5 yr Direct Visual F/S & F
C101005 INTERIOR
WINDOWS
Fixed or operable windows. Assemblies would include frames, glazing, caulking and other associated work. B N/A 5 yr Direct Visual F/S & F
C101006 GLAZED
PARTITIONS &
STOREFRONTS
Fixed interior glazed partitions including interior storefronts with doors.
Assemblies include frames, glazing, caulking, and other associated work. B N/A 5 yr Direct Visual F/S & F
C1020
C102001 STANDARD
INTERIOR
DOORS
Assemblies include all standard interior wood or hollow metal doors with frames, finish, etc.. Standard interior door may include vision lites. Interior door hardware is located in C102007 INTERIOR DOOR HARDWARE.
B N/A 5 yr Direct Visual F/S & F
C102002 GLAZED
INTERIOR
DOORS
Assemblies include all glazed interior doors with glass, frames, finish, including storefront, etc.. Interior door hardware is located in C102007 INTERIOR DOOR
HARDWARE.
B N/A 5 yr Direct Visual F/S & F
C102003 FIRE DOORS Assemblies include all interior fire doors, including all necessary frames, and sensing devices integral with the door. Interior door hardware is located in
C102007 INTERIOR DOOR HARDWARE.
B N/A 5 yr Direct Visual F/S & F
C102004 SLIDING &
FOLDING
DOORS
Assemblies include all sliding and folding doors with frames, hardware, locking devices, tracks, and supporting systems. The unit of measure at the assembly level is each.
B N/A 5 yr Direct Visual F/S & F
C102005 INTERIOR
OVERHEAD
DOORS
Overhead doors installed in the interior of a facility. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.
B N/A 5 yr Direct Visual F/S & F
C102090 OTHER
INTERIOR
SPECIALTY
Any special type door installed in the interior of a facility. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit measure at the assembly level is each gate.
B N/A 5 yr Direct Visual F/S & F
C102091 OTHER
INTERIOR
PERSONNEL
Interior personnel doors not described by the assembly categories listed above.
B N/A 5 yr Direct Visual F/S & F
Cipher Lock B N/A 5 yr Direct Visual F/S & F
INTERIOR
This assembly includes partitions, interior doors, and specialties.
Includes all interior partitions.
All interior doors.
INTERIOR CONSTRUCTION
PARTITIONS
INTERIOR DOORS
| USAF Built Infrastructure |
| Table of Contents |
| I. Overview |
| A. C10 Interior Construction System description |
| II. Inventory |
| A. General C10 Inventory Guidance |
| B. Inventory C1010 Interior Partitions |
| C. Inventory C1020 Interior Doors |
| D. Inventory C1030 Fittings |
| III. Assessment |
| A. General C10 Assessment Guidance |
| B. Assessment C1010 Interior Partitions |
| C. Assessment C1020 Interior Doors |
| D. Assessment C1030 Fittings |
| IV. Inventory and Assessment Rules of Thumb |
| A. Assessor Qualifications |
| B. Year Installed |
| C. Inventory/Assessment |
| V. Inventory / Assessment Data Collection Sheet |
| VI. C10 UNIFORMAT II Minimum Component Reference Table |