AMEND1.pdf
PDF 121 KB Posted
- Attached to
- WASHER/DRYER
- Solicitation number
- W44W9M-18-T-0032
About this file
see attached corrected amendment
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMENDMENT.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACTING OFFICE/DAL
DARLA LOTT
918-420-6577/MCALESTER CONTRACTING
1 C TREE ROAD
MCALESTER OK 74501-9002
W44W9M7276009F
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
see attached changes
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 20-Nov-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W44W9M-18-T-0032
X 9B. DATED (SEE ITEM 11)
08-Nov-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
20-Nov-2017
CODE
CONTRACTING OFFICE
MCALESTER ARMY AMMUNITION PLANT
1 C TREE ROAD
MCALESTER OK 74501-9002
W44W9M 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W44W9M
FACILITY CODECODE
EMAIL:TEL:
W44W9M-18-T-0032
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 16-Nov-2017 04:00 PM to 30-Nov-2017 04:00 PM.
The following have been added by full text:
AMENDED BILL OF MATERIALS
WASHER-EXTRACTOR
AND CABINET DRYER
1-PPE Washer-Extractor: industrial strength hard mount design, must be NFPA 1851 compliance.
BEARINGS/DRIVE SHAFT: cylindrical front/spherical rear bearings.
FRAME: Made of plate steel and equipped with inverter drive.
CYLINDER RIBS: Perforated cylinder ribs and equipped with optispray.
ENLARGED DOOR OPENING: hinge and handle paired with a roll pin/cam door lock system. Door opening will be 24.8" large.
ELECTRICAL: 3-phase 208V 16 amp service
SPECIFICATIONS
Capacity - lb (kg) 130 (60) Cylinder Diameter - in (mm) 42 (1067) Cylinder Depth - in (mm) 24 1/2 (622) Cylinder Volume - cu. ft. (liters) 19.6 (555) Width - in (mm) 46 1/8 (1171) Depth - in (mm) 54 1/2 (1384) Height - in (mm) 72 5/8 (1844) Door Opening Size - in (mm) 24 13/16 (630) Door Bottom to Floor - in (mm) 29 13/16 (758) Motor Size - HP (kW) 10 (7.5) Control Options UniLinc™ M30 Total # of Speeds V Sp M Sp 8 6 Cylinder Speed RPM (G-Force) Gentle 26 (.40) 26 (.40) Wash 36 (.77) 36 (.77)
W44W9M-18-T-0032
Distribution 65 (2.5) 65 (2.5) Very Low Extract 213 (27) 213 (27) Low Extract 410 (100) 410 (100) Medium Extract 579 (200) 579 (200) High Extract 648 (250) – Very High Extract 710 (300) – Drain Diameter - in (mm) 2 @ 3 (76) 1 @ 3 (76) Water Inlet Connection - in (mm) 2 @ 1 (25) + 2 @ 3/4 (19)
2 @ 1 (25) Shipping Dimensions - in (mm) Width 49 3/16 (1250) Depth 64 13/16 (1646) Height 76 3/8 (1941) Net Weight - lb (kg) 2040 (925) Standard Shipping Weight - lb (kg) 2100 (953) Slat Crate Shipping Weight - lb (kg) 2260 (1025) Agency Approvals cETLus, CE
1-FIREMAN’S PPE DRYING CABINET: 6 full sets of turnout gear capacity, five programmable cycles, Doors open at complete 180° Angle, Adjustable leveling legs, Space for up to 15 boots/gloves, Rack design for maximum water removal, Electrostatically-applied paint for superior bonding and corrosion resistance, 100% front serviceable, utility shelf and must be NFPA 1851 compliance.
SPECIFICATIONS ON NEXT PAGE.
Electrical: 3-phase 208v 50/60Hz 35amp or 40amp breaker service.
Capacity – 6 full sets of turnout gear Electric Heating – 12 KW Electric connection Circuit breaker- 208 V – 50/60 HZ 3 PH. 35A breaker Exhaust Diameter – in (mm) 6 (152) Outlet Airflow – cfm (m3/h) 300 (510) Width – in (mm) 61 1/8 (1552) Depth – in (mm) 32 5/8 (828) Height – in (mm) Outer: 80 3/8 (2042) Inner: 79 7/16 (2018) Net Weight – lb (kg) 534 (242) Shipping Weight – lb 605 (274) Agency Approvals CSA
(End of Summary of Changes)