W25G1V-16-T-0242
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 28-Jun-2016 05:00 PM to 29-Jun-2016 05:00 PM.
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been added by full text:
QUESTIONS FROM THE TOUR
WHERE WILL THE ELECTRIC PULL FROM : Electric will be pulled from control box.
WILL THE HEAT TRACE HAVE AN ALARM: The heat trace will have an alarm.
WILL THERE BE A BACKUP: Yes, a backup will be supplied with each pump. No floats.
WILL YOU DRAIN THE TANK FOR THE WORK TO BE DONE: We will drain post equalization tank the best we can and the contractor is responsible for the rest to replace the pump.
NOTE: SCADA repairs will be an ammonia probe replacement tied into the SCADA system and functional.
(End of Summary of Changes) image1.wmf