About this file

This is a tapered roof plan drawing prepared by QXO Engineering for Vista Square Elementary School located at 540 G Street, Chula Vista, California 91910, in support of a roofing replacement contract opportunity. The drawing specifies the design and installation requirements for a tapered roof system using Polyiso insulation material with a 20 psi rating, minimum thickness of 1/2 inch, and maximum thickness of 8.5 inches with a tapered slope. The plan includes detailed panel dimensions, spacing measurements, and specifications for taper panels and cricket installations, with material dimensions ranging from Q through Q+6 positions. The drawing notes that the material will be shipped to match the specifications and quantities indicated, and that contractors must receive all owner-furnished materials, including sheet metal, at their secure yard or warehouse between March 1-31, 2027.

The District reserves the right to award the roofing replacement contract at various school locations in one of two ways: as two separate contracts awarded to the lowest responsive, responsible bidder for each bid package, or as a single contract covering all school sites awarded based on the total bid amount. Contractors are responsible for verification of all field conditions, dimensions, drain and scupper locations, product specifications, and compliance with applicable building codes. The drawing emphasizes that improper material handling or discarding more than half of useable tapered insulation pieces or one-quarter of flat insulation pieces will result in material shortages and is the contractor's responsibility to manage efficiently.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q

Q+2

Q+4

Q+6Q

Q

Q+2Q

Q Q

Q Q

Q Q

Q Q

Q Q

Q

Q+2

Q+4

Q+6 Q

Q +2

Q +4

Q

'-1

0"

'-0

13'-2"

TAPER PANELS

TAPERED CRICKET

TAPERED PANELSTAPERED PANELS

PANEL DI0ENSION SLOPE

Q 1/2"1/2" - 2 1/2"

Q

.5"

2.5"

Q+2

4.5"

Q+4

6.5"

Q+6

8.5"

2" IS

O

2" IS

O

2" IS

O

0" - 12" x 6" T.E.S.

TAPER SPECS

TAPERED MATERIAL:

TAPERED SLOPE:

MINIMUM THICKNESS:

MAXIMUM THICKNESS:

R-VALUE (AVG/MIN):

CRICKET SPECS

CRICKET MATERIAL:

CRICKET SLOPE:

MINIMUM THICKNESS:

MAXIMUM THICKNESS:

DISCLAIMER:

QXO ENGINEERING DID NOT PERFORM AND OR

CONDUCT ANY DESIGN OR ENGINEERING

ANALYSIS IN CONJUNCTION WITH THE

PREPARATION OF THESE DRAWINGS. THESE

DRAWINGS REPRESENT A RECITATION AND

GRAPHIC DEPICTION OF THE MANUFACTURERS

SPECIFICATIONS AND THE DESIGN DETAILS

ONLY. THESE DRAWINGS SHOULD NOT AND ARE

NOT TO BE CONSTRUED AS CONSTITUTING

DESIGN ERECTION DRAWINGS, SPECIFICATIONS

OR DESIGN DETAILS PREPARED OR APPROVED

BY QXO ENGINEERING. THE

ARCHITECT'S/ENGINEER'S APPROVED DESIGN

OF THE ROOF IS THE CONTROLLING DOCUMENT.

CONTRACTOR REMAINS RESPONSIBLE FOR THE

INSTALLATION IN COMPLIANCE WITH THAT

APPROVED DESIGN.

NOTES:

INSTALLER MUST VERIFY ALL FIELD

DIMENSIONS, DRAIN AND SCUPPER LOCATIONS

AND PRODUCT SPECIFICATIONS FOR

ACCURACY. MATERIAL WILL BE SHIPPED TO

MATCH THE SPECIFICATIONS AND QUANTITIES

NOTED HEREON. CONTRACTOR IS RESPONSIBLE

FOR VERIFICATION OF ALL FIELD CONDITIONS

AND COMPLIANCE WITH BUILDING CODE ISSUES.

THE TAPERED LAYOUT ILLUSTRATED ON THIS

DRAWING REQUIRES THE INSTALLER TO REUSE

PARTIAL PIECES OF INSULATION, THEREFORE,

DISCARDING MORE THAN HALF OF A USEABLE

PIECE OF TAPERED INSULATION AND/OR ONE

QUARTER OF A PIECE OF FLAT INSULATION WILL

RESULT IN A SHORTAGE OF MATERIAL FOR

YOUR TAPERED SYSTEM.

PROJECT NOTES:

PR

O

JE

C

T:

R O

O

FI

N G

C O

N

TR

A C

TO

R

A B C D E F G H

DATE:

PROJECT NUMBER:

QUOTE NUMBER:

DRAWN BY:

DRAWING PAGES:

Engineering Services

VI

ST

A S

Q U

A R

E

EL

EM

EN

TA

R

Y

SC

H O

O L

G S t, C hu la

V is ta , C

A

A G

A R

LA

N

D C

O M

PA

N

Y

PR

O

JE

C T

N/A N/A N/A N/A N/A

Polyiso 20psi 1/2"

0.00" w/TES 8.5"

9/11/2026 F26-28810-R1 Q260911-117 B. Billingsley

TAPERED ROOF PLAN

SCALE� �

Sheets and Views
SHOP DWG

File details come from the government source that posted it. Updated .