VOLUME_6c.pdf

PDF 13 MB Posted

Attached to
Construction - Research and VMU Building Federal contract opportunity
Solicitation number
VA10115R0123
Issued by
Department of Veterans Affairs Headquarters

About this file

VOLUME 6c

View the file

Other files for this federal contract opportunity

Other files attached to Construction - Research and VMU Building, newest first.
File Type Posted
VA101-15-R-0123-A00008000.docx DOCX document
VA101-15-R-0123-A00008001.pdf PDF
VA101-15-R-0123-A00008003.pdf PDF
VA101-15-R-0123-A00007008.pdf PDF
VA101-15-R-0123-A00007007.pdf PDF
VA101-15-R-0123-A00007003.pdf PDF
VA101-15-R-0123-A00007002.pdf PDF
VA101-15-R-0123-A00007000.docx DOCX document
VA101-15-R-0123-A00007004.pdf PDF
VA101-15-R-0123-A00006001.pdf PDF
VA101-15-R-0123-A00006000.docx DOCX document
VA101-15-R-0123-A00005008.pdf PDF
VA101-15-R-0123-A00005001.pdf PDF
VA101-15-R-0123-A00005015.pdf PDF
VA101-15-R-0123-A00005010.pdf PDF
VA101-15-R-0123-A00005003.pdf PDF
VA101-15-R-0123-A00005011.pdf PDF
VA101-15-R-0123-A00005014.pdf PDF
VA101-15-R-0123-A00004003.pdf PDF
VA101-15-R-0123-A00004006.pdf PDF
VA101-15-R-0123-A00004005.pdf PDF
VA101-15-R-0123-A00002106.pdf PDF
VA101-15-R-0123-A00002099.pdf PDF
VA101-15-R-0123-A00002084.pdf PDF
VA101-15-R-0123-A00002087.pdf PDF
VA101-15-R-0123-A00002098.pdf PDF
VA101-15-R-0123-A00002074.pdf PDF
VA101-15-R-0123-A00002081.pdf PDF
VA101-15-R-0123-A00002101.pdf PDF
VA101-15-R-0123-A00002102.pdf PDF
VA101-15-R-0123-A00002097.pdf PDF
VA101-15-R-0123-A00002082.pdf PDF
VA101-15-R-0123-A00002075.pdf PDF
VA101-15-R-0123-A00002078.pdf PDF
VA101-15-R-0123-A00002088.pdf PDF
VA101-15-R-0123-A00002080.pdf PDF
VA101-15-R-0123-A00001003.pdf PDF
VA101-15-R-0123-A00001001.ppt PPT presentation
VA101-15-R-0123-A00001000.docx DOCX document
VA101-15-R-0123_2.docx DOCX document
VOLUME_6a.pdf PDF
General_Decision_Number.pdf PDF
VAPA-RVMU-Specifications_Vol_01.pdf PDF
VOLUME_5b.pdf PDF
VOLUME_3.pdf PDF
VOLUME_5a.pdf PDF
VOLUME_4b.pdf PDF
List_of_Attachments.pdf PDF
VOLUME_6b.pdf PDF
VOLUME_2.pdf PDF
Show all 50

Construction - Research and VMU Building has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JJ

IR

EOL

PIV

XRM

RM

MM

DM

SMOKE DETECTOR (AREA)

IN

D

IC

A

T E

A

LA

R M

A T

A

LL

S P

E A

K E

R S

A N

D S

T R

O B

E S

IN

D

IC

A

T E

S U

P E

R V

IS

O

R Y

A T

F A

C P

A N

D R

E M

O T

E A

N N

U N

C

IA

T O

R

IN

D

IC

A

T E

T R

O U

B

LE

A T

F A

C P

A N

D R

E M

O T

E A

N N

U N

C

IA

T O

R

R E

P O

R T

A

LA

R M

T O

4H

R M

A N

N E

D M

O N

IT

O

R

IN

G S

T A

T

IO

N

R E

P O

R T

T R

O U

B

LE

T O

4H

R M

A N

N E

D M

O N

IT

O

R

IN

G S

T A

T

IO

N

N O

T

IF

Y F

IR

E

D E

P A

R T

M E

N T

C

LO

S E

A S

S O

C

IA

T E

D S

M O

K E

B A

R R

IE

R

D O

O R

S O

N F

LO

O

R

S H

U T

D O

W N

A S

S O

C

IA

T E

D H

V A

C U

N

IT

C

LO

S E

F

IR

E S

M O

K E

D A

M P

E R

S N

E A

R D

E T

E C

T O

R

IN

D

IC

A

T E

S U

P E

R V

IS

O

R Y

S

IG

N A

L T

O

4H R

M A

N N

E D

M O

N

IT

O R

IN

G

S T

A T

IO

N

ACTION

DEVICE

SMOKE DETECTOR (DOOR RELEASE)

IN

D

IC

A

T E

A

LA

R M

A T

F A

C P

A N

D R

E M

O T

E A

N N

U N

C

IA

T O

R

R E

C A

LL

E

LE

V

A T

O R

T O

E X

IT

IN

G F

LO

O

R

A N

N U

N C

IA

T

E S

O

LI

D I

LL

U

M

IN

A T

IO

N

I N

S

ID

E E

LE

V

A T

O R

C A

B

A N

N U

N C

IA

T

E F

LA

S

H

IN

G I

LL

U

M

IN

A T

IO

N

I N

S

ID

E E

LE

V

A T

O R

C A

B

DUCT SMOKE DETECTOR AT FIRE SMOKE DAMPER

HVAC UNIT DUCT SMOKE DETECTOR SUPPLY

BREAK IN SIGNALING LINE CIRCUIT

BREAK IN NOTIFICATION APPLIANCE CIRCUIT

GROUND IN SIGNALING LINE CIRCUIT

GROUND IN NOTIFICATION APPLIANCE CIRCUIT

WIRE TO WIRE SHORT IN SIGNALING LINE CIRCUIT

WIRE TO WIRE SHORT IN NOTIFICATION APPLIANCE CIRCUIT

MONITOR MODULE (SPRINKLER WATER FLOW SWITCH)

MONITOR MODULE (SPRINKLER VALVE TAMPER)

SMOKE DETECTOR (ELEVATOR MACHINE ROOM)

MANUAL PULL STATION

HEAT DETECTOR (ELEVATOR MACHINE ROOM)

IN

IT

IA

T

E E

LE

V

A T

O R

S H

U T

D O

W N

A N

D D

IS

C

O N

N E

C T

E

LE

V A

T O

R P

O W

E R

SMOKE DETECTOR (ELEVATOR LOBBY)

MONITOR MODULE (LOSS OF POWER TO ELEV SHUNT TRIP CIRCUIT)

MONITOR MODULE (PIV)

DH

DAA

FCPS

FATC

FACP

FAAN

FS

HD

FS

X X X

X

X X

X

X X

1.

2.

3.

PROVIDE COMPLETE FIRE ALARM SYSTEM PROGRAMMING AS REQUIRED TO ACTIVATE ALL DEVICES AND FUNCTIONS AS SHOWN ON PLANS.

VERIFY PROGRAMMING DESCRIPTION FOR ALL DEVICES WITH THE RESIDENT ENGINEER. SUBMIT COMPLETE PROGRAMMING SCHEDULE AND DESCRIPTIONS PRIOR TO PROGRAMMING NEW DEVICES INTO

SYSTEM.

PROGRAM INITIATING DEVICES, SUCH AS SMOKE DETECTORS, MANUAL PULL STATIONS, MONITOR MODULE (FOR WATER FLOW SWITCH) TO INITIATE NOTIFICATION DEVICES AND TO SEND AN ALARM TO THE

FACP AND 24 HOUR MANNED STATIONS.

NOTES RE: FIRE ALARM MATRIX OF OPERATIONS

FIRE ALARM MATRIX OF OPERATIONS

MODEL, P/NDESCTRIPTION REMARKS

FIRE ALARM SYSTEM LEGEND SYMBOLS

ABBREV./

SYMBOL

BACKBOX EQUIPMENT

DIGITAL AUDIO AMPLIFIER WITH POWER SUPPLY

BOARD AND CHASSIS.

ADDRESSABLE RELAY MODULE

DAA-5070

8.0 AMP REMOTE POWER SUPPLY WITH BUILT-IN

SYNC

FCPS-24S8

FRM-1

ADDRESSABLE SMOKE DETECTOR, CEILING

MOUNTED, PHOTOELECTRIC TYPE WITH

STANDARD MOUNTING BASE

FSP-851

B210LP

MAGNETIC DOOR HOLDER DEVICE

STROBE, WALL MOUNT

WATER FLOW SWITCH

ADDRESSABLE MANUAL PULL STATION, DUAL

ACTION WITH KEY LOCKING FEATURE.

DUCT DETECTOR REMOTE KEY TEST AND

ANNUNCIATOR STATION.

NBG-12LX

RST151 KEY

NOTIFIER

NOTIFIER

NOTIFIER

NOTIFIER

HVAC DUCT SMOKE DETECTOR AND HOUSING DNR

FSP-851

FSP-851R

NOTIFIER

VALVE TAMPER SWITCH

LOCATE IN #EQDR-D4 ENCLOSURE. NOTIFIER

PROVIDE TYPE PER MFR RQMT. FLUSH MOUNT BACKBOX AT FINISHED

SPACES, OTHERWISE SURFACE MOUNT WHERE LOCATED IN CEILING SPACE,

UTILITY SPACES AND OUTDOORS. PROVIDE WITH WEATHERPROOF BACKBOX

WHERE LOCATED IN AN OUTDOOR ENVIRONMENT.

4"SQx21/8"D - FLUSH MOUNT BACKBOX. SURFACE MOUNT IS ONLY

ACCEPTABLE IN UTILITY SPACES. PROVIDE BACKBOX TYPE PER MFR

REQUIREMENTS.

SEE MANUFACTURER REQUIREMENTS.

SYSTEM SENSOR

DEACTIVATE DOOR HOLDERS WHEN MANUAL PULL STATIONS, WATERFLOW SWITCH, HEAT DETECTOR AND SMOKE DETECTORS ARE IN ALARM.4.

5. PROGRAM MONITOR MODULE (FOR VALVE TAMPER) AND POST INDICATOR VALVE TO SIGNAL A SUPERVISORY TO THE MAIN FACP AND 24 HOUR MANNED STATIONS.

ADDRESSABLE SINGLE MONITOR MODULE FMM-1 NOTIFIER

N/A

N/A PROVIDE MONITOR MODULE. COORDINATE WORK WITH DIVISION 21.

PROVIDE MONITOR MODULE. COORDINATE WORK WITH DIVISION 21.

ADDRESSABLE DUAL MONITOR MODULE FDM-1 UTILIZE FOR NEW VALVE TAMPER AND NEW WATER FLOW SWITCHES.

COORDINATE CONNECTIONS WITH DIVISION 21.

NOTIFIER

SR 4"SQx21/8"D - FLUSH MOUNT BACKBOX. SURFACE MOUNT IS ONLY

ACCEPTABLE IN UTILITY SPACES. PROVIDE BACKBOX TYPE PER MFR

REQUIREMENTS.

PROVIDE WEATHERPROOF TYPE, #DNRW WHERE LOCATED OUTDOORS.

PROVIDE SAMPLING TUBE TO SUIT DUCT WIDTH. INCLUDE ACCESSORIES

REQUIRED FOR COMPLETE INSTALLATION. PROVIDE #FSP-851R WHERE

CONTROLLED BY REMOTE TEST SWITCH.

PROVIDE EACH DIGITAL AUDIO AMPLIFIER WITH BATTERY CHASSIS AND TWO

12.0AH BATTERIES.

4"SQx21/8"D - FLUSH MOUNT BACKBOX. SURFACE MOUNT IS ONLY

ACCEPTABLE IN UTILITY SPACES. PROVIDE BACKBOX TYPE PER MFR

REQUIREMENTS.

MOUNT 7'-0"AFF, E.A.N.

PROVIDE MANUFACTURER SPECIFIED BACKBOX, FLUSH TYPE. PROVIDE WITH

WEATHERPROOF, SURFACE BACKBOX WHERE LOCATED OUTDOORS.

ONLY LOCATE ON WALL WHERE INDICATED ON FIRE ALARM PLANS.

PROVIDED IN ANOTHER DIVISION OF WORK. PROVIDE WIRING TO CONNECT TO

NEAREST 24VDC FIRE ALARM POWER SUPPLY, U.O.N.

MFR

(NO SUBSTITUTIONS)

FIRE ALARM TERMINAL CABINET 24186 TCS

ADDRESSABLE CEILING MOUNTED HEAT

DETECTOR (57°C/135°F) RATE COMPENSATION

WITH DETECTOR BASE

FST-851

B210LP

PROVIDE WITH RED COLOR FINISH.SURFACE MOUNT TYPE. PROVIDE SIZE TO SUIT INSTALLATION.

JUNCTION BOX - CEILING OR WALL MOUNT TYPE. _ PROVIDE WITH RED COLOR FINISH.PROVIDE WEATHERPROOF TYPE WHERE EXPOSED TO THE OUTDOOR

ENVIRONMENT. PROVIDE FLUSH TYPE WHERE INSTALLED IN PUBLIC AREAS

AND FINISHED SPACES.

FIRE ALARM CONTROL PANEL WITH DIGITAL

VOICE COMMAND

NFS2-3030 ADDRESSABLE FIRE ALARM CONTROL PANEL WITH NCA-2 DISPLAY AND XP6-C

MODULES FOR ELEVATOR CONTROLLER INTERFACE.

PROVIDE ENCLOSURE SIZE TO ALSO INCLUDE ANNUNCIATOR DISPLAY, DIGITAL

VOICE COMMAND AUDIO PROCESSOR WITH MESAGE STORAGE, FIREFIGHTERS

TELEPHONE HANDSET, DIGITAL AUDIO AMPLIFIERS, POWER SUPPLIES,

MOUNTING KITS, ETC. FOR A COMPLETE AND OPERATIONAL SYSTEM.

NOTIFIER

NOTIFIER

FIRE ALARM COMBINATION AUDIBLE/STROBE SPSR

SPSRH

4"SQx21/8"D - FLUSH MOUNT BACKBOX. SURFACE MOUNT IS ONLY

ACCEPTABLE IN UTILITY SPACES. PROVIDE BACKBOX TYPE PER MFR

REQUIREMENTS.

SYSTEM SENSOR

SPEAKER, WALL MOUNT. SPR

SPRV

SPRK

SPSRK

4"SQx21/8"D - FLUSH MOUNT BACKBOX. SURFACE MOUNT IS ONLY

ACCEPTABLE IN UTILITY SPACES. PROVIDE BACKBOX TYPE PER MFR

REQUIREMENTS. PROVIDE WEATHERPROOF TYPE WHERE LOCATED IN AN

OUTDOOR ENVIRONMENT.

SYSTEM SENSOR

6. RELAY MODULE FOR SECURITY PANEL SHALL COMMUNICATE ALARM TO THE SECUIRTY ACCESS CONTROL SYSTEM.

7.

PROGRAM THE SMOKE DETECTORS AT THE ELEVATOR LOBBY OF LEVEL 1 AND IN THE ELEVATOR MACHINE ROOM TO ACTIVATE THE FIRE ALARM CONTROL RELAY TO INITIATE ELEVATOR RECALL TO LEVEL 2 (ALTERNATE LEVEL RECALL), WITH THE EXCEPTION OF THE ANIMAL ELEVATOR WHERE ALTERNATE LEVEL RECALL SHALL OCCUR AT LEVEL V.

8.

PROGRAM THE SMOKE DETECTOR AT ELEVATOR LOBBIES (EXCEPT AT THE DESIGNATED LEVEL RECALL) TO ACTIVATE THE FIRE ALARM CONTROL RELAY TO INITIATE ELEVATOR RECALL TO LEVEL 1

(DESIGNATED LEVEL RECALL).

PROGRAM THE SMOKE DETECTOR IN THE ELEVATOR MACHINE ROOM TO ACTIVATE THE FIRE ALARM CONTROL RELAY TO INITIATE FLASHING OF THE FIRE FIGHTER'S HELMET SYMBOL IN THE ELEVATOR CAB.

PROGRAM THE SMOKE DETECTOR IN THE ELEVATOR LOBBIES TO ACTIVATE THE FIRE ALARM CONTROL RELAY TO INITIATE SOLID ILLUMINATION OF THE FIRE FIGHTER'S HELMET SYMBOL IN THE ELEVATOR CAB.

9.

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X X X

X X

X X XXX

X X X

X X X

X

X

X

X

X

X

SPEAKER, CEILING MOUNT, SINGLE COIL TYPE,

70.7V, 8" DIAMETER

ATLAS SOUNDPROVIDE WITH COMPATIBLE UL APPROVED ENCLOSURE TO MEET UL 1480

LISTING.

UKT70C-U161-8

PROVIDE TYPE PER MFR RQMT. FLUSH MOUNT BACKBOX AT FINISHED

SPACES, OTHERWISE SURFACE MOUNT WHERE LOCATED IN CEILING SPACE,

UTILITY SPACES AND OUTDOORS. PROVIDE WITH WEATHERPROOF BACKBOX

WHERE LOCATED IN AN OUTDOOR ENVIRONMENT.

PROVIDE TYPE PER MFR RQMT. FLUSH MOUNT BACKBOX AT FINISHED

SPACES, OTHERWISE SURFACE MOUNT WHERE LOCATED IN CEILING SPACE,

UTILITY SPACES AND OUTDOORS. PROVIDE WITH WEATHERPROOF BACKBOX

WHERE LOCATED IN AN OUTDOOR ENVIRONMENT.

X X X X

X

X

X

PROGRAM HEAT DETECTOR IN THE ELEVATOR MACHINE ROOMS TO ACTIVATE THE FIRE ALARM CONTROL RELAY TO DISCONNECT ELEVATOR POWER.10.

PROGRAM DUCT DETECTORS TO ACTIVATE ASSOCIATED RELAY MODULES TO SHUTDOWN THE SUPPLY FAN.11.

PROGRAM DUCT DETECTORS TO ACTIVATE THE CLOSURE OF FIRE SMOKE DAMPERS UNLESS OTHERWISE NOTED.12.

4"SQx21/8"D - FLUSH MOUNT BACKBOX. SURFACE MOUNT IS ONLY

ACCEPTABLE IN UTILITY SPACES. PROVIDE BACKBOX TYPE PER MFR

REQUIREMENTS.

X

PROGRAM MONITOR MODULES TO SIGNAL A SUPERVISORY TO THE MAIN FACP AND 24 HOUR MANNED STATIONS UPON LOSS OF POWER TO THE ELEVATOR SHUNT TRIP CIRCUIT.13.

X X

14.

INTERPOSING RELAY

PROVIDE PER MANUFACTURER REQUIREMENTS.

SEE SHEET FA6.1.1 FOR ADDITIONAL REQUIREMENTS.

END OF LINE RESISTOR

24 HOUR MANNED STATIONS - THE ADDRESSABLE FIRE ALARM SYSTEM SHALL TRANSMIT ALARM, SUPERVISORY, AND TROUBLE SIGNALS VIA NETWORK CABLING TO ANNUNCIATOR PANELS LOCATED AT BUILDING 100 (POLICE DISPATCH), BUILDING 40 (BOILER PLANT) AND BUILDING 41 (ENGINEERING).

PROVIDE COMPLETE FIRE ALARM PROGRAMMING AT ALL 24 HOUR MANNED STATION TO MONITOR AND ACCEPT RESEARCH AND VMU INTO THE EXISTING FIRE ALARM CAMPUS NETWORK LOOP.15.

X

X

X

X

NOTIFIER

R-20T(A) NOTIFIER/

HONEYWELL

PROVIDE MONITOR MODULE. COORDINATE WORK WITH CIVIL DRAWINGS.POST INDICATOR VALVE N/A

CONVENTIONAL MANUAL PULL STATION, DUAL

ACTION WITH KEY LOCKING FEATURE.

NBG-12LOB NOTIFIERPROVIDE MANUFACTURER SPECIFIED BACKBOX, FOR EXTERIOR

INSTALLATIONS.

WP

RELAY MODULE AT HOISTWAY LOUVER SHALL ACTIVATE VENTING UPON SMOKE DETECTED BY HOISTWAY SMOKE DETECTOR.16.

FIRE ALARM REMOTE ANNUNCIATOR PANEL

WITH REMOTE DIGITAL VOICE COMMAND

NCA-2 WITH DVC PROVIDE ENCLOSURE SIZE TO ALLOW INSTALLATION OF REMOTE

ANNUNCIATOR DISPLAY, HIGH SPEED NETWORK MODULE, REMOTE PAGING

UNIT, FIREFIGHTER'S TELEPHONE HANDSET, CHASSIS, POWER SUPPLY /

BATTERIES AND OTHER COMPONENTS NECESSARY TO PROVIDE A COMPLETE

AND OPERATIONAL REMOTE ANNUNCIATION / REMOTE PAGING SYSTEM.

NOTIFIER

X

X X

REFER TO DETAIL 54 ON SHEET FA6.1.1.ADDRESSABLE SIX RELAY CONTROL MODULE XP6-R PROVIDE WITH ENCLOSURE AND CHASSIS FOR MOUNTING MODULE. NOTIFIER

PROVIDE FLUSH MOUNTED ENCLOSURE WHERE LOCATED INDOORS. PROVIDE

SURFACE MOUNTED ENCLOSURE WITH CUSTOM WEATHERPROOF EXTERNAL

HOUSING FOR OUTDOOR INSTALLATIONS.

PROVIDE ADDITIONAL AUXILIARY POWER SUPPLIES/BATTERIES TO OPERATE

ALL NOTIFICATION DEVICES AND DOOR HOLDERS.

MINIMIZE OR AVOID DISRUPTION TO FIRE ALARM SYSTEMS.

DELINEATE PHASING OF CONSTRUCTION TO ENSURE THE

INSTALLATION OF NEW SYSTEMS ARE EXPEDITED, AND MAINTAIN

EXISTING SYSTEMS IN SERVICE AS REQUIRED UNTIL THE SYSTEM

IS OPERATIONAL.

1.

INSTALLATION OF THE FIRE ALARM SYSTEM SHALL NOT

COMMENCE UNTIL DETAILED SHOP DRAWINGS AND REQUIRED

SUBMITTALS ARE PROVIDED BY THE CONTRACTOR AND

REVIEWED BY THE RESIDENT ENGINEER PER SPECIFICATIONS.

2.

INSTALLATION OF FIRE ALARM SYSTEM SHALL BE PERFORMED

BY A FACTORY TRAINED AUTHORIZED REPRESENTATIVE.

3.

A SET OF APPROVED FIRE ALARM SHOP DRAWINGS SHALL BE AT

THE JOB SITE AT ALL TIMES. ANY DEVIATION FROM THE

APPROVED PLANS, INCLUDING SUBSTITUTION OF COMPONENTS

AND/OR DEVICES, SHALL BE REVIEWED WITH AND APPROVED BY

THE RESIDENT ENGINEER PRIOR TO IMPLEMENTATION.

4.

5. DO NOT INSTALL SMOKE DETECTORS UNTIL AFTER THE

CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND

FINAL, EXCEPT WHEN SMOKE DETECTORS COME WITH PLASTIC

COVERINGS FROM THE MANUFACTURER.

WHERE CONFLICTING INFORMATION IS FOUND BETWEEN THE

SPECIFICATIONS AND DRAWINGS, THE MOST STRINGENT

DIRECTION SHALL APPLY, UNLESS DIRECTED OTHERWISE BY

THE RESIDENT ENGINEER. SUBMIT INQUIRY TO THE RESIDENT

ENGINEER FOR CLARIFICATION AND RESOLUTION.

6.

PROVIDE TEMPORAL - THREE DISTINCTIVE FIRE ALARM SOUND

FOR AUDIBLE NOTIFICATION DEVICES WITHIN ZONE OF ALARM.

7.

AUDIBLE FIRE ALARM SOUND LEVEL SHALL BE AT LEAST 15dB ABOVE THE REDUCED AVERAGE AMBIENT SOUND LEVEL OR 5dB

ABOVE THE MAXIMUM SOUND LEVEL WITH A DURATION OF 60

SECONDS, AFTER REDUCTION OF AMBIENT SOUND LEVEL,

WHICHEVER IS GREATER PER IBC AND NFPA 72.

8.

VISUAL DEVICES SHALL NOT EXCEED 2 FLASHES PER SECOND

AND SHALL NOT BE SLOWER THAN 1 FLASH EVERY SECOND.

PROVIDE SYNCHRONIZED STROBES WHERE MULTIPLE STROBE

DEVICES ARE LOCATED WITHIN SIGHT OF EACH OTHER.

9.

INSTALL FIRE ALARM WIRING IN METAL RACEWAY. PAINT EXPOSED

FIRE ALARM CONDUITS, ENCLOSURES, JUNCTION BOXES AND COVER

PLATES WITH SPECIFIED RED PAINT, EXCEPT WHERE CONDUIT IS

INSTALLED UNDERGROUND OR RECESSED IN WALLS. SEE

SPECIFICATION SECTION 260533 RACEWAY AND BOXES FOR

ELECTRICAL SYSTEMS FOR ALLOWABLE CONDUIT TYPES.

10.

CONDUCTORS INSTALLED IN WET LOCATION EITHER ABOVE OR

BELOW GROUND SHALL BE MOISTURE-RESISTANT OR OF A TYPE

APPROVED FOR USE UNDER WET CONDITIONS.

11.

ALL NEW RACEWAY INSIDE BUILDINGS SHALL BE ROUTED TIGHT

TO THE STRUCTURE, PARALLEL AND PERPENDICULAR TO

BUILDING LINES. INSTALL RACEWAY IN A MANNER TO AVOID

CONFLICT WITH OTHER ELEMENTS.

12.

UNDERGROUND AND EXTERIOR CONDUITS SHALL HAVE WATER-

TIGHT FITTINGS. (NEC 110-11 AND 300-6).

13.

COORDINATE ROUTING OF CONDUITS WITH OTHER TRADES.

GROUP CONDUITS IN A NEAT AND ORGANIZED MANNER.

HOMERUNS AND MAJOR CONDUITS SHALL BE GROUPED AND

RACKED NEAR MAIN STRUCTURAL MEMBERS. REVIEW

PROPOSED METHOD OF WALL PENETRATIONS WITH VA RESIDENT

ENGINEER AND ARRANGE AS DIRECTED.

14.

DO NOT INSTALL CONDUIT OR RACEWAY THROUGH BEAMS OR

OTHER STRUCTURAL MEMBERS UNLESS SPECIFICALLY

PERMITTED BY VA RESIDENT ENGINEER.

15.

16. REFER TO ELECTRICAL DRAWINGS EP6.1.X SERIES FOR

ADDITIONAL REQUIREMENTS.

PROVIDE U.L. LISTED FIRESTOP SYSTEM THROUGH RATED

WALL AND FLOOR OPENINGS MADE BY NEW CONDUIT

PENETRATIONS.

17.

DO NOT LOCATE CEILING SMOKE DETECTORS WITHIN 3'-0" OF

SUPPLY DIFFUSERS.

18.

LA

D

6/30/2017

L

No. E15435

TE

S

TA

AC

T R

EXP

OF

E L E C

L

ER

TE

I

G R

E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N

EE

I

S P

SOR FE ION

C

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

P R

IN

T

E D

O N

/1

/2

:0 :1

P

M

GENERAL NOTES, SYMBOLS AND

SCHEDULES

FA0.1.0

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

GENERAL NOTES

ABBREVIATIONS

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

BLDG BUILDING

cd CANDELA

CKT CIRCUIT

DAA DIGITAL AUDIO AMPLIFIER

DED DEDICATED

DPDT DOUBLE POLE DOUBLE THROW

DWG DRAWING

(E) EXISTING

E.A.N. EXCEPT AS NOTED

ELEV ELEVATOR

FA FIRE ALARM

FAAN FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROLS PANEL

FATC FIRE ALARM TERMINAL CABINET

FCPS FIRE ALARM POWER SUPPLY

FFSD FAN FIRE SHUTDOWN

FSD FIRE SMOKE DAMPER

FOTC FIBER OPTIC TERMINAL CABINET

(ALSO KNOWN AS FIBER OPTIC PATCH

PANEL)

WIRING REQUIREMENTS

NEW FIRE ALARM SYSTEM SHALL CONSIST OF:

1. CLASS A WIRING FOR SPEAKERS' DIGITAL AUDIO AMPLIFIERS.

2. CLASS B WIRING FOR IDC, SLC AND NAC FOR LOCAL BUILDING USE.

3. STYLE 7, CLASS A WIRING (6 STRAND, SINGLE MODE FIBER OPTIC CABLE, UNDERGROUND RATED, 62.5/125 MICRON) FOR SLC FOR

COMMUNICATION BETWEEN BUILDINGS' FIRE ALARM PANEL.

PROVIDE SPECIFIC FIRE ALARM SYSTEM CABLING TYPE AND QUANTITY PER FIRE ALARM SHOP DRAWING SUBMITTAL AND PER FIRE ALARM

EQUIPMENT MANUFACTURER REQUIREMENTS.

PROVIDE 1-INCH CONDUIT MINIMUM BETWEEN FIRE ALARM DEVICES AND EQUIPMENT INSIDE THE BUILDING. PROVIDE SEPARATE CONDUITS FOR

NAC AND SLC CIRCUITS.

FOR NEW SINGLE MODE FIBER OPTIC CONNECTIONS TO EXISTING FIRE ALARM PANELS UTILIZING MULTI-MODE FIBER:

REPLACE THE NETWORK CARD IN EXISTING, AFFECTED FIRE ALARM PANEL(S). PROVIDE NEW NETWORK CARD TYPE COMPATIBLE WITH BOTH SINGLE MODE AND MULTI-MODE FIBER OPTIC CABLES TO ALLOW COMMUNICATION BETWEEN NEW AND EXISTING FIRE ALARM

CONTROL PANELS.

SITE RELATED WORK:

ESTABLISH A CONNECTION WITH THE EXISTING FIRE ALARM CAMPUS NETWORK. PROVIDE NEW NETWORKING CABLING FROM RVMU BUILDING TO BUILDING 103, AND FROM RVMU BUILDING TO BUILDING 701 (PARKING STRUCTURE 2). FOR SITE PLAN, REFER TO SHEET

FA1.1.1. FOR CAMPUS RISER DIAGRAM, REFER TO SHEET FA5.1.1.

IDC INITIATING DEVICE CIRCUIT

MFR MANUFACTURER

N/A NOT APPLICABLE

NAC NOTIFICATION APPLIANCE CIRCUIT

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

PIV POST INDICATOR VALVE

PNL PANEL

(R) REMOVAL

RQMT REQUIREMENTS

RVMU RESEARCH AND VETERINARY MEDICAL UNIT

SLC SIGNALING LINE CIRCUIT

U.O.N. UNLESS OTHERWISE NOTED

WP WEATHERPROOF

DN

UP

DN

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

IMAGING

V-238

SURGERY

V-236

SURGERY

V-234

SURGERY

V-232

MEN

V-331B

WOMEN

V-331C

LOCKER

V-331

LOUNGE

V-331A

ANIMAL PREP

V-223

SCRUB

V-230B

CORRIDOR

CV-230

CORRIDOR

CV-240

SURGERY

INSTRUMENT

STORAGE

V-242

SURGERY

EQUIPMENT

STORAGE

V-244

SAFETY

STORAGE

V-136

IT

V-TC1

SIGNAL

V-SC1

HAC

V-134

CONF

V-132

ELEVATOR

MACHINE

V-EV1

STAIR 1

V-ST1

LOBBY

V-100

OFFICE

V-111C

OFFICE

V-111B

OFFICE

TECHNICIANS

AND

COMPUTER

WORKROOM

V-111

PASSENGER

ELEV #2

P02

PASSENGER

ELEV #1

P01

CORRIDOR

CV-110

GOWNING

V-120

KITCHENETTE

V-111A

COPY ALCOVE

V-111D

KITCHEN

V-303A

COLD FOOD

V-301

MEN TOILET

V-123

MEN SHOWER

V-123A

LOCKER +

LOUNGE

V-121WOMEN TOILET

V-122

WOMEN

SHOWER

V-122A

VENDING

V-135

STORAGE

V-137

CORRIDOR

CV-130

BEHAVIOR

LARGE

V-321D

BEHAVIOR

V-321C

BEHAVIOR

V-321B

BEHAVIOR

V-321A

CORRIDOR

CV-320

BEHAVIOR

V-321

ELECTRICAL

V-EC3

BEHAVIOR

V-321H

BEHAVIOR

V-321G

BEHAVIOR

V-321FBEHAVIOR

STORAGE

V-321E

ELECTRICAL

V-EC2

STAIR 2

V-ST2

CORRIDOR

CV-200

SURGERY

SUPPLY

STORAGE

V-235

X-RAY

V-241

C ARM

V-230A

CORRIDOR

CV-220

CORRIDOR

CV-210

SURGERY

RECOVERY

V-222

ANIMAL TECH

OFFICE

V-221

HAC

V-211

CLEAN CAGE

STOR

V303B

CAGE WASH

TUNNEL

WASHER +

CAGE / RACK

WASHER -

CLEAN SIDE

V-303

CAGE WASH

TUNNEL

WASHER +

CAGE / RACK

WASHER -

DIRTY SIDE

V-305

EQUIPMENT

V-305A

CORRIDOR

CV-300

BSL-2 HOLD'G

V-386A

BSL-2 HOLD'G

V-386B

LAUNDRY

V-312

ANIMAL WATER

V-312A

ANIMAL

HOLDING

V-310

ANIMAL

HOLDING

V-308

ANIMAL

HOLDING

V-306

ANIMAL

HOLDING

V-304

ANIMAL

HOLDING

V-343

ANIMAL

HOLDING

V-345

ANIMAL

HOLDING

V-347

ANIMAL

HOLDING

V-349

BSL-2

PROCEDURE

V-386

ANIMAL

HOLDING

V-384C

ANIMAL

HOLDING

V-384B

ANIMAL

HOLDING

V-384A

BSL-2 ANTE

V-382

NECROPSY

V-314

COLD

CARCASS

V-309

DETERGENT

DISPENSING

SYSTEM

V-300B

AWS PCCX

CLOSET

V-300C

CO2 CLOSET

V-400A

O2 CLOSET

V-400B

HAC

V-381

VESTIBULE

V-313

CORRIDOR

CV-380

CORRIDOR

CV-340

ANTE

V-330

PROCEDURE

V-342

PROCEDURE

V-353

PROCEDURE

V-344

ANTE

V-357

PROCEDURE

V-346

PROCEDURE

V-363

ANTE

V-365

PROCEDURE

V-371

ANIMAL

HOLDING

V-384E

ANIMAL

HOLDING

V-384D

ANIMAL

HOLDING

V-384F

BSL-2 CUBICLE

SUITE

V-384

PROCEDURE

V-373

ANTE

V-375

DIAGNOSTICS

LAB

V-348

HAC

V-379

HAC

V-404

VESTIBULE

V-377

CORRIDOR

CV-360

CORRIDOR

CV-370

CORRIDOR

CV-350

ANIMAL

HOLDING

V-352

ANIMAL

HOLDING

V-354

ANIMAL

HOLDING

V-356

ANIMAL

HOLDING

V-358

ANIMAL

HOLDING

V-362

ANIMAL

HOLDING

V-364

ANIMAL

HOLDING

V-366

ANIMAL

HOLDING

V-372

ANIMAL

HOLDING

V-374

ANIMAL

HOLDING

V-376

QUARANTINE

V-378

IT

V-TC2

SIGNAL

V-SC2

MECHANICAL

V-ME2

VMU STORAGE

V-401

STAIR 4

V-ST4

ELEVATOR

MACHINE

V-EV2

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

ANIMAL

ELEVATOR

LOBBY

V-390

ANIMAL

QUARANTINE

V-394A

LARGE ANIMAL

QUARANTINE

V-394B

ANIMAL

RECEIVING

V-394

NON

COMMERCIAL

HOLDING

V-392B

VESTIBULE

V-311

STORAGE+PUMP

ROOM

V-307

NON

COMMERCIAL

PROCEDURE

V-392

NON

COMMERCIAL

HOLDING

V-392A

CORRIDOR

CV-400

VMU TRANSFER

CLOSET

V-402

ELECTRICAL

V-EC1

PROCEDURE

ROOM LARGE

V-302

ZONE V-1

ZONE V-2

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

UTILITY

U-102

STAIR 4

U-ST4

VESTIBULE

U-101

VESTIBULE

U-103

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

UTILITY

U-100

STAIR 2

U-ST2

STAIR 3

U-ST3

PASSENGER

ELEV #1

P01

PASSENGER

ELEV #2

P02

STAIR 1

V-ST1

ZONE U-1

ZONE U-2

LA

D

6/30/2017

L

No. E15435

TE

S T

A

AC

T R

EXP

OF

E L E C

L

E R

T E

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/16" = 1'-0"

16' 16' 32'8'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

/1

/2

:0 :3

P

M

OVERALL FIRE ALARM ZONING

PLANS LEVEL V & LEVEL U

FA2.1.1

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM ZONING FLOOR PLAN LEVEL V

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM ZONING FLOOR PLAN LEVEL U

EQUIPMENT

1-304

DARK IMAGING

1-318

FREEZER

1-412

GLASS WASH

1-319

TISSUE

1-305

EQUIPMENT

1-310TISSUE

1-306

ELECTRICAL

1-EC1

SIGNAL

1-SC1

IT

1-TC2

ELECTRICAL

1-EC2

SIGNAL

1-SC2IT

1-TC1

EMERGENCY

ELECTRICAL

1-EC4

MAIN

ELECTRICAL

1-EC3

EQUIPMENT

1-309

EQUIPMENT

1-312

FUME

1-313

TISSUE

1-311

EQUIPMENT

1-315

TISSUE

1-314

STAFF LOUNGE

1-422

COLD ROOM

1-303

SWING

1-317

FUME

1-316

EQUIPMENT

1-307

ADA FUME

1-308

WOMEN

1-221 MEN

1-223

SWING

1-424

CORRIDOR

C1-200

VESTIBULE

1-220A

VESTIBULE

1-220B

CONDENSER

1-302A

EMS RECEIVING

1-501

OFFICE

1-202E

STAIR 3

1-ST3

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

HAC

1-225

OPEN LAB

1-301

STAIR 4

1-ST4

CORRIDOR

C1-210

CORRIDOR

C1-410

CORRIDOR

C1-420

CORRIDOR

C1-400

MECH SHAFT 1

YY

MECH SHAFT 2

ANIMAL

ELEVATOR

LOBBY

1-530

CORRIDOR

C1-500

STORAGE

1-502

STAIR 5

1-ST5

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

CORRIDOR

C1-220

GOGGLE

ALCOVE

1-220C

STORAGE

1-220E

STAFF LOUNGE

1-226

CORRIDOR

C1-300

STORAGE

1-506

EMS TOILET

1-504

ENTRY LOBBY

C1-100

PASSENGER

ELEV #1

P01

PASSENGER

ELEV #2

P02

STAIR 1

1-ST1

ZONE 1-1

INSTRUMENT

2-411

MICROSCOPY

2-421

INSTRUMENT

2-405

FREEZER

2-412

DARK IMAGING

2-318

GLASS WASH

2-319TISSUE

2-305

EQUIPMENT

2-310

TISSUE

2-306

ELECTRICAL

2-EC1

SIGNAL

2-SC1

IT

2-TC2

ELECTRICAL

2-EC2

SIGNAL

2-SC2

IT

2-TC1

EQUIPMENT

2-309

EQUIPMENT

2-312

FUME

2-313

TISSUE

2-311

EQUIPMENT

2-315

FUME

2-316

TISSUE

2-314

INSTRUMENT

2-407

STAFF LOUNGE

2-226

COLD ROOM

2-303

SWING

2-424

CORRIDOR

C2-200

WOMEN

2-221

MEN

2-223

EQUIPMENT

2-307

ADA FUME

2-308

STAFF LOUNGE

2-422

EQUIPMENT

2-304

CORRIDOR

C2-300

SWING

2-317

CONDENSER

2-302A

CORRIDOR

C2-210

CORRIDOR

C2-410

CORRIDOR

C2-420

CORRIDOR

C2-400A

CONFERENCE

ROOM

2-202H

STAFF

WORKROOM

2-202

STAIR 3

2-ST3

STAIR 4

2-ST4

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

HAC

2-225

OPEN LAB

2-301

VESTIBULE

2-220A

VESTIBULE

2-220B

MECH SHAFT

SHAFT 1

MECH SHAFT

SHAFT 2

CORRIDOR

C2-500

1 2 3 4 5 6 7 8 9 10 11

B

C

D

E

F

G

FREEZER

2-403

INSTRUMENT

2-409

MECH SHAFT

AV-921

? ALCOVE

C2-220C

STORAGE

2-220D

STAIR 1

2-ST1

PASSENGER

ELEV #2

P02

PASSENGER

ELEV #1

P01

HALLWAY

2-320

CORRIDOR

C2-400B

ZONE 2-1

LA

D

6/30/2017

L

No. E15435

TE

S T

A

AC

T R

EXP

OF

E L E C

L

E R

T E

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/16" = 1'-0"

16' 16' 32'8'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

B

D

E

C

/1

/2

:0 :5

P

M

OVERALL FIRE ALARM ZONING

PLANS LEVEL 1 & LEVEL 2

FA2.1.2

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM ZONING FLOOR PLAN LEVEL 1

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM ZONING FLOOR PLAN LEVEL 2

STAIR 4

R-ST4

1 2 3 4 5 6 7 8 9 10 11 12 13

B

C

D

E

F

G

ZONE R-1

LA

D

6/30/2017

L

No. E15435

TE

S T

A

AC

T R

EXP

OF

E L E C

L

E R

T E

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/16" = 1'-0"

16' 16' 32'8'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

B

D

E

C

/1

/2

:0 :0

P

M

OVERALL FIRE ALARM ZONING

PLAN ROOF LEVEL

FA2.1.3

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM FLOOR PLAN ROOF LEVEL

ANIMAL

HOLDING

V-310

ANIMAL

HOLDING

V-308

ANIMAL

HOLDING

V-306ANIMAL

HOLDING

V-304

ANIMAL

HOLDING

V-343

ANIMAL

HOLDING

V-345

ANIMAL

HOLDING

V-349

BSL-2 CUBICLE

SUITE

V-384

BSL-2 ANTE

V-382

BSL-2 HOLD'G

V-386A

BSL-2

PROCEDURE

V-386

BSL-2 HOLD'G

V-386B

NON

COMMERCIAL

HOLDING

V-392A

QUARANTINE

V-378

DIAGNOSTICS

LAB

V-348

ANTE

V-375

PROCEDURE

V-373

ANIMAL

HOLDING

V-374

ANIMAL

HOLDING

V-376

ANIMAL

HOLDING

V-372

ANIMAL

HOLDING

V-366

ANIMAL

HOLDING

V-364

ANIMAL

HOLDING

V-362

ANIMAL

HOLDING

V-358

ANIMAL

HOLDING

V-356

ANIMAL

HOLDING

V-354

PROCEDURE

V-353

PROCEDURE

V-344

PROCEDURE

V-346

ANTE

V-357

PROCEDURE

V-363

ANTE

V-365

PROCEDURE

V-371

HAC

V-379

STORAGE+PUMP

ROOM

V-307

ANIMAL

RECEIVING

V-394

VMU TRANSFER

CLOSET

V-402

NON

COMMERCIAL

HOLDING

V-392B

COLD

CARCASS

V-309 LARGE ANIMAL

QUARANTINE

V-394B

ANIMAL

QUARANTINE

V-394A

CORRIDOR

CV-360

CORRIDOR

CV-340

CORRIDOR

CV-370

CORRIDOR

CV-350

CORRIDOR

CV-400

LAUNDRY

V-312

NON

COMMERCIAL

PROCEDURE

V-392

NECROPSY

V-314

ELECTRICAL

V-EC1

SIGNAL

V-SC2

HAC

V-404

IT

V-TC2

VMU STORAGE

V-401

STAIR 4

V-ST4

HAC

V-381

VESTIBULE

V-311

ANIMAL

HOLDING

V-347

ANIMAL

HOLDING

V-384D

ANIMAL

HOLDING

V-384E

ANIMAL

HOLDING

V-384F

ANIMAL

HOLDING

V-384C

ANIMAL

HOLDING

V-384B

ANIMAL

HOLDING

V-384A

VESTIBULE

V-313

GOWNING

V-120

BEHAVIOR

V-321A

BEHAVIOR

V-321B

BEHAVIOR

V-321C

BEHAVIOR

LARGE

V-321D

BEHAVIOR

STORAGE

V-321E

BEHAVIOR

V-321F

BEHAVIOR

V-321G

BEHAVIOR

V-321H

SURGERY

EQUIPMENT

STORAGE

V-244

SURGERY

V-234

SURGERY

RECOVERY

V-222

BEHAVIOR

V-321

ELEVATOR

MACHINE

V-EV1

PROCEDURE

ROOM LARGE

V-302

VMU STORAGE

V-341

MEN

V-331B

WOMEN

V-331C

ANIMAL

HOLDING

V-352

PROCEDURE

V-342

LOCKER +

LOUNGE

V-121

WOMEN TOILET

V-122

MEN TOILET

V-123

IMAGING

V-238

SURGERY

V-236

SURGERY

V-232 LOCKER

V-331

ANTE

V-330

ANIMAL TECH

OFFICE

V-221X-RAY

V-241

C ARM

V-230A

KITCHENETTE

V-111A

OFFICE

V-111C

OFFICE

V-111B

LOUNGE

V-331ASCRUB

V-230B

CAGE WASH

TUNNEL

WASHER +

CAGE / RACK

WASHER -

CLEAN SIDE

V-303

SAFETY

STORAGE

V-136

IT

V-TC1

SIGNAL

V-SC1

ANIMAL PREP

V-223

SURGERY

SUPPLY

STORAGE

V-235

HAC

V-134

SURGERY

INSTRUMENT

STORAGE

V-242

HAC

V-211

CORRIDOR

CV-110

CORRIDOR

CV-300

VENDING

V-135

CORRIDOR

CV-200

CORRIDOR

CV-230

LOBBY

V-100

CLEAN CAGE

STOR

V303B

COLD FOOD

V-301

KITCHEN

V-303A

ANIMAL WATER

V-312A

OFFICE

TECHNICIANS

AND

COMPUTER

WORKROOM

V-111

STAIR 2

V-ST2

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

PASSENGER

ELEV #1

P01

PASSENGER

ELEV #2

P02

VESTIBULE

V-377

MECHANICAL

V-ME2

CORRIDOR

CV-210

ELEVATOR

MACHINE

V-EV2

ELECTRICAL

V-EC2

STORAGE

V-137

CO2 CLOSET

V-400A

ANIMAL

ELEVATOR

LOBBY

V-390

CAGE WASH

TUNNEL

WASHER +

CAGE / RACK

WASHER -

DIRTY SIDE

V-305

ELECTRICAL

V-EC3

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

SEE SHEET FA3.1.1BSEE SHEET FA3.1.1A

LA

D

6/30/2017

L

No. E15435

TE

S T

A

AC

T R

EXP

OF

E L E C

L

E R

T E

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/16" = 1'-0"

16' 16' 32'8'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

/1

/2

:0 :1

P

M

OVERALL FIRE ALARM FLOOR

PLAN LEVEL V

FA3.1.1

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM FLOOR PLAN LEVEL V 3.03 3.04

PP

C R

C R

PP PP PP

P P

P P

C R

PP

PP

PP

PP

PP

PP

PP

PP

C R

C R

C R

CR

CR CRCR

4' BSC

' B

S C

' B

S C

4' BSC

4' BSC 4' BSC

' B

S C

' B

S C

' B

S C

' B

S C

ANTEN ANTEN ANTEN ANTEN

M F

D I

E W

CW

E1

CA

C o lW

C o lW

R

D

PUMP

E1

E1

S

CR

D

RINSE

TANK

TW

EXHAUST

DA

E2

EXHAUST

ANTEN ANTEN ANTEN

ANTENANTEN

M F

E W

IN

C

IN

C

MF

DI

EW

M F

D I

E W

M F

D I

E W

MF

DI

EW

MF

DI

EW

MF

DI

EW

E1

S

CR

D RINSE

TANK

TW

EXHAUST

DA

E2

MF

DI

EW

MF

DI

EW

XRM

XRM

FS

HD

F S

FS

DM

RM

D H

D H

RM

MM

HD

HD

RM

RM

RM

1 2 3 4 5 6 7

A

B

C

D

E

F

G

F A

3.

1.

1B F

A 3.

1.

1B

FATC (TOP)

FCPS (BOTTOM)

DAA

CAGE WASH

TUNNEL WASHER

+ CAGE / RACK

WASHER - CLEAN

SIDE

V-303

CLEAN CAGE

STOR

V303B

KITCHEN

V-303A

COLD FOOD

V-301

CORRIDOR

CV-300

CORRIDOR

CV-320

ELECTRICAL

V-EC3

VMU STORAGE

V-341

CORRIDOR

CV-340

ANIMAL HOLDING

V-343

ANIMAL HOLDING

V-345

PROCEDURE

V-344

PROCEDURE

V-353

PROCEDURE

V-342

CORRIDOR

CV-350

ANIMAL HOLDING

V-352

ANIMAL HOLDING

V-354

ANIMAL HOLDING

V-356

LOCKER

V-331

WOMEN

V-331C

MEN

V-331B

LOUNGE

V-331A

ANTE

V-330

HAC

V-211

ANIMAL TECH

OFFICE

V-221

ANIMAL PREP

V-223

SURGERY

V-232

SURGERY

V-234

SURGERY

V-236

IMAGING

V-238

SURGERY

INSTRUMENT

STORAGE

V-242

CORRIDOR

CV-230

SCRUB

V-230B

CORRIDOR

CV-220

CORRIDOR

CV-210

BEHAVIOR

V-321G BEHAVIOR

V-321H

BEHAVIOR

V-321FBEHAVIOR

STORAGE

V-321E

SURGERY

RECOVERY

V-222

SURGERY

SUPPLY

STORAGE

V-235

X-RAY

V-241

CORRIDOR

CV-240

CORRIDOR

CV-200

CORRIDOR

CV-130

STAIR 2

V-ST2

ELECTRICAL

V-EC2

STORAGE

V-137

BEHAVIOR LARGE

V-321D BEHAVIOR

V-321C

BEHAVIOR

V-321B

BEHAVIOR

V-321A

MEN TOILET

V-123

MEN SHOWER

V-123A

LOCKER +

LOUNGE

V-121

WOMEN TOILET

V-122

WOMEN SHOWER

V-122A

VENDING

V-135

GOWNING

V-120

CORRIDOR

CV-110

SAFETY STORAGE

V-136

SURGERY

EQUIPMENT

STORAGE

V-244

IT

V-TC1

SIGNAL

V-SC1

HAC

V-134

ELEVATOR

MACHINE

V-EV1

LOBBY

V-100

COPY ALCOVE

V-111D

OFFICE

TECHNICIANS

AND COMPUTER

WORKROOM

V-111

KITCHENETTE

V-111A

PROCEDURE

ROOM LARGE

V-302

ANIMAL HOLDING

V-304

ANIMAL HOLDING

V-306

BEHAVIOR

V-321

ANIMAL HOLDING

V-358

ANIMAL HOLDING

V-345

ANIMAL HOLDING

V-308

ANTE

V-357

15cd

15cd

30cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd 15cd

30cd

15cd

15cd

15cd

75cd

15cd

30cd

75cd

15cd

15cd

15cd

15cd

15cd

75cd

75cd

15cd

15cd

15cd

75cd

3.01

CONF

V-132

PASSENGER ELEV

#2

P02

PASSENGER ELEV

#1

P01

STAIR 1

V-ST1

OFFICE

V-111C

OFFICE

V-111B

3.03

3.05

3.07 3.08TYPICAL

3.06

3.04

3.03

LA

D

6/30/2017

L

No. E15435

TE

S

TA

AC

T R

EXP

OF

E L E C

L

ER

TE

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/8" = 1'-0"

8' 8' 16'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

SHEET NOTES

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

D

G

B

H

C

F

J

E

KEYNOTES

/1

/2

:0 :3

P

M

FIRE ALARM FLOOR PLAN

LEVEL V

FA3.1.1A

PO KL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/8" = 1'-0"

LEVEL V - FIRE ALARM - AREA A

1. FOR ADDITIONAL REQUIREMENTS, REFER TO SHEETS FA5.1.x AND

FA6.1.x SERIES DRAWINGS.

2. ALL FIRE ALARM DEVICES SHALL BE PROGRAMMED BY A CERTIFIED

FIRE ALARM TECHNICIAN.

3. PRIOR TO INSTALLATION OF INTERCONNECTING WIRING BETWEEN

FIRE ALARM DEVICES, SUBMIT SHOP DRAWINGS FOR APPROVAL.

4. PROVIDE FIRESTOP THROUGH WALL AND FLOOR OPENINGS MADE BY

CONDUITS AT RATED WALLS AND FLOORS.

5. COORDINATE SPEAKER INSTALLATION WITH HOSPITAL WIDE PAGING

SINCE THEY ARE DUAL VOICE COIL TYPE.

6. COORDINATE INSTALLATION OF FIRE ALARM DEVICES AND WIRING WITH

OTHER TRADES WHERE FIRE ALARM IS USED TO INTERFACE WITH

BUILDING SYSTEMS, SUCH AS MECHANICAL EQUIPMENT, DUCTWORK,

SECURITY EQUIPMENT, DOOR HARDWARE, SPRINKLER SYSTEMS, ETC.

3.01 FIRE ALARM DEVICE FOR SECURITY PANEL - COORDINATE

INSTALLATION WITH SECURITY WORK.

3.03 DOOR HOLDERS TO BE PROVIDED BY OTHERS. PROVIDE 24VDC

AND CONNECT TO FIRE ALARM AUXILIARY POWER SUPPLY VIA

FIRE ALARM RELAY MODULE. COORDINATE INSTALLATION WITH

DOOR INSTALLATION WORK.

3.04 FIRE ALARM DEVICES FOR ELEVATOR CIRCUIT BREAKER SHUNT

TRIP. COORDINATE FIRE ALARM WORK WITH ELECTRICAL

WORK. REFER TO DETAIL 52, SHEET FA6.1.1 AND DETAIL 54,

SHEET FA5.1.2.

3.05 FIRE ALARM DEVICES FOR ELEVATOR PRIMARY AND

SECONDARY RECALL AND FIRE FIGHTERS HELMET ELEVATOR

CAB SIGNAL. COORDINATE FIRE ALARM WORK WITH ELEVATOR

WORK.

3.06 FIRE ALARM DEVICE FOR SPRINKLER SYSTEM - COORDINATE

INSTALLATION WITH SPRINKLER WORK.

3.07 LOCATE HEAT DETECTOR WITHIN 2'-0" OF SPRINKLER HEAD IN

ELEVATOR MACHINE. LOCATION SHOWN IS APPROXIMATE -

SPACE OUT AND COORDINATE INSTALLATION WITH SPRINKLER

WORK. PROVIDE ADDITIONAL HEAT DETECTORS AND

ASSOCIATED WIRING AND PROGRAMMING AS REQUIRED TO

COMPLY IN LOCATING A HEAT DETECTOR WITHIN 2'-0" OF EACH

SPRINKLER HEAD.

3.08 FAN FIRE SHUTDOWN - COORDINATE INSTALLATION WITH

MECHANICAL WORK.

R

C R

C R

CR

PP

PP

PP

PP

PP

PP PP

PP

PP

PP

CR

C R

PP

PP

PP

P P

PP PP

PP

PP

P P

C R

6' BSC

' B

S C

' B

S C

' B

S C

4' BSC

' B

S C

4' BSC

' B

S C

' B

S C

' B

S C

' B

S C

PR

' B

S C

4' BSC

4' BSC

4' BSC 4' BSC

' B

S C

' B

S C

' B

S C

' B

S C

' B

S C

' B

S C

' B

S C

' B

S C

' B

S C

4' BSC 4' BSC

' B

S C

4' BSC

ANTEN ANTEN ANTEN ANTEN ANTEN

CW

SV1

E1

S

E2AS

E3 D

CW

E1

SCAPS

C o lW

C o lW

R

CR

D

FD

E1

PUMP

E1

CA

E1

S

CR

D

RINSE

TANK

CWTW

EXHAUST

WASH

TANK 2

WASH

TANK 1

DA

E2

CA

E1

S

CR

DA

CW

TW

EXHAUST

FD

FD

MF

DI

EW

ANTEN ANTEN ANTEN ANTEN

CWVAC

E D1D2

ANTEN ANTEN ANTEN

ANTENANTENANTEN

ANTEN

ANTEN ANTEN ANTEN

ANTENANTEN

ANTEN

MF

MF

EW

MF

MF

ANTEN

ANTEN

M F

E

WM

F

E W

MF

EW

M F

D I

E W

MF

RAI

ANTEN

IN

C

IN

C

MF

DI

EW

ANTEN

MF

DI

EW

RPM

ABOVE

RPM

ABOVE

RPM

ABOVE

RPM

ABOVE

RPM

ABOVE

RPM

ABOVE

RPM

ABOVE

RPM

ABOVE

R P

M

A B

O V

E

RPM

ABOVE

MF

E1

CA

EX

CA

E1

S

CR

D RINSE

TANK

CWTW

EXHAUST

WASH

TANK 2

WASH

TANK 1

DA

E2

MF

DI

EW

MF

DI

EW

MF

DI

EW

MF

DI

EW

MF

DI

EW

F S

XRM

XRM

XRM

HD

FS

RM

DM

RMMM

HD

RM

HDHD

HD

HD

HDHD

RM

RM

HD

7 8 9 10 11 12 13

A

B

C

D

E

F

G

F A

3.

1.

1A F

A 3.

1.

1A

IT

V-TC2

FATC (TOP)

FCPS (BOTTOM)

DAA

ANIMAL HOLDING

V-345

PROCEDURE

V-344

ANIMAL HOLDING

V-356

ANIMAL HOLDING

V-306

ANIMAL HOLDING

V-358

ANIMAL HOLDING

V-362

ANIMAL HOLDING

V-364

ANIMAL HOLDING

V-366

ANIMAL HOLDING

V-372

ANIMAL HOLDING

V-374

ANIMAL HOLDING

V-376

QUARANTINE

V-378

SIGNAL

V-SC2

CORRIDOR

CV-400

MECHANICAL

V-ME2

BSL-2 CUBICLE

SUITE

V-384

ANIMAL HOLDING

V-384E

ANIMAL HOLDING

V-384F

ANIMAL HOLDING

V-384D

ANIMAL HOLDING

V-349

ANIMAL HOLDING

V-345

ANIMAL HOLDING

V-347

ANIMAL HOLDING

V-384C

ANIMAL HOLDING

V-384B

ANIMAL HOLDING

V-384A

BSL-2 ANTE

V-382

CORRIDOR

CV-380

ELECTRICAL

V-EC1

VMU TRANSFER

CLOSET

V-402

HAC

V-381NECROPSY

V-314

BSL-2 HOLD'G

V-386A

BSL-2 HOLD'G

V-386B

BSL-2

PROCEDURE

V-386

ANIMAL WATER

V-312A

ANIMAL HOLDING

V-310

ANIMAL HOLDING

V-308 LAUNDRY

V-312

CORRIDOR

CV-300

STORAGE+PUMP

ROOM

V-307

CAGE WASH

TUNNEL WASHER

+ CAGE / RACK

WASHER - DIRTY

SIDE

V-305

EQUIPMENT

V-305A

NON

COMMERCIAL

HOLDING

V-392A

NON

COMMERCIAL

PROCEDURE

V-392

NON

COMMERCIAL

HOLDING

V-392B

ANIMAL

RECEIVING

V-394 ANIMAL

QUARANTINE

V-394A

LARGE ANIMAL

QUARANTINE

V-394B

VESTIBULE

V-311

COLD CARCASS

V-309

ANIMAL

ELEVATOR

LOBBY

V-390

SERVICE

ELEVATOR

S02

SERVICE

ELEVATOR

S01

VESTIBULE

V-313

ELEVATOR

MACHINE

V-EV2

STAIR 4

V-ST4

VMU STORAGE

V-401

ANTE

V-357

PROCEDURE

V-346

PROCEDURE

V-363

ANTE

V-365

PROCEDURE

V-371

PROCEDURE

V-373

ANTE

V-375

DIAGNOSTICS

LAB

V-348

HAC

V-379

VESTIBULE

V-377

HAC

V-404

CORRIDOR

CV-370

CORRIDOR

CV-360

75cd

15cd

15cd

15cd

15cd

15cd

15cd 15cd

15cd15cd

15cd 15cd

15cd

15cd

15cd

30cd

75cd

75cd

75cd

15cd 15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

3.01

3.02

3.03

3.043.08

3.07

3.06 TYPICAL

TYPICAL

3.08

3.08

3.08

3.08

LA

D

6/30/2017

L

No. E15435

TE

S

TA

AC

T R

EXP

OF

E L E C

L

ER

TE

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/8" = 1'-0"

8' 8' 16'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

SHEET NOTES

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

D

G

B

H

C

F

J

E

KEYNOTES

/1

/2

:0 :0

P

M

FIRE ALARM FLOOR PLAN

LEVEL V

FA3.1.1B

PO KL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/8" = 1'-0"

LEVEL V - FIRE ALARM - AREA B

1. FOR ADDITIONAL REQUIREMENTS, REFER TO SHEETS FA5.1.x AND

FA6.1.x SERIES DRAWINGS.

2. ALL FIRE ALARM DEVICES SHALL BE PROGRAMMED BY A CERTIFIED

FIRE ALARM TECHNICIAN.

3. PRIOR TO INSTALLATION OF INTERCONNECTING WIRING BETWEEN

FIRE ALARM DEVICES, SUBMIT SHOP DRAWINGS FOR APPROVAL.

4. PROVIDE FIRESTOP THROUGH WALL AND FLOOR OPENINGS MADE BY

CONDUITS AT RATED WALLS AND FLOORS.

5. COORDINATE SPEAKER INSTALLATION WITH HOSPITAL WIDE PAGING

SINCE THEY ARE DUAL VOICE COIL TYPE.

6. COORDINATE INSTALLATION OF FIRE ALARM DEVICES AND WIRING

WITH OTHER TRADES WHERE FIRE ALARM IS USED TO INTERFACE

WITH BUILDING SYSTEMS, SUCH AS MECHANICAL EQUIPMENT,

DUCTWORK, SECURITY EQUIPMENT, DOOR HARDWARE, SPRINKLER

SYSTEMS, ETC.

3.01 FIRE ALARM DEVICE FOR SECURITY PANEL - COORDINATE

INSTALLATION WITH SECURITY WORK.

3.02 FIRE ALARM DEVICE FOR SPRINKLER SYSTEM - COORDINATE

INSTALLATION WITH SPRINKLER WORK.

3.03 FIRE ALARM DEVICES FOR ELEVATOR CIRCUIT BREAKER SHUNT

TRIP. COORDINATE FIRE ALARM WORK WITH ELECTRICAL WORK.

REFER TO DETAIL 52, SHEET FA6.1.1 AND DETAIL 54, SHEET

FA5.1.2.

3.04 FIRE ALARM DEVICES FOR SERVICE ELEVATOR PRIMARY AND

SECONDARY RECALL AND FIRE FIGHTERS HELMET ELEVATOR

CAB SIGNAL. COORDINATE FIRE ALARM WORK WITH ELEVATOR

WORK.

3.06 LOCATE SMOKE DETECTOR IN BEAM POCKET OF ELEVATOR

MACHINE ROOM STRUCTURE.

3.07 LOCATE HEAT DETECTOR WITHIN 2'-0" OF SPRINKLER HEAD IN

ELEVATOR MACHINE. LOCATION SHOWN IS APPROXIMATE -

SPACE OUT AND COORDINATE INSTALLATION WITH SPRINKLER

WORK. PROVIDE ADDITIONAL HEAT DETECTORS AND

ASSOCIATED WIRING AND PROGRAMMING AS REQUIRED TO

COMPLY IN LOCATING A HEAT DETECTOR WITHIN 2'-0" OF EACH

SPRINKLER HEAD.

3.08 FAN FIRE SHUTDOWN - COORDINATE INSTALLATION WITH

DN

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

UTILITY

U-102

STAIR 4

U-ST4

VESTIBULE

U-101

VESTIBULE

U-103

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

SEE SHEET FA3.1.2BSEE SHEET FA3.1.2A

UTILITY

U-100

UTILITY

U-100

UTILITY

U-102

STAIR 2

U-ST2

STAIR 3

U-ST3

PASSENGER

ELEV #1

P01

PASSENGER

ELEV #2

P02

STAIR 1

V-ST1

LA

D

6/30/2017

L

No. E15435

TE

S T

A

AC

T R

EXP

OF

E L E C

L

E R

T E

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/16" = 1'-0"

16' 16' 32'8'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

/1

/2

:0 :3

P

M

OVERALL FIRE ALARM FLOOR

PLAN LEVEL U

FA3.1.2

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM FLOOR PLAN LEVEL U 3.03 3.04

DN

F S

RM

RM

RM

RM

RM

RM

RM RM RM

RM

RM

RM

RM

1 2 3 4 5 6 7

A

B

C

D

E

F

G

F A

3.

1.

2B F

A 3.

1.

2B

STAIR 2

U-ST2

VESTIBULE

U-103

UTILITY

U-102

STAIR 3

U-ST3

PASSENGER ELEV

#1

P01

PASSENGER ELEV

#2

P02

STAIR 1

V-ST1

3.01

3.02 TYPICAL

LA

D

6/30/2017

L

No. E15435

TE

S

TA

AC

T R

EXP

OF

E L E C

L

ER

TE

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/8" = 1'-0"

8' 8' 16'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

SHEET NOTES

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

D

G

B

H

C

F

J

E

KEYNOTES

/1

/2

:0 :4

P

M

FIRE ALARM FLOOR PLAN

LEVEL U

FA3.1.2A

PO KL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/8" = 1'-0"

OVERALL FIRE ALARM FLOOR PLAN LEVEL U

3.01 ?3.01 FIRE ALARM DEVICE MOUNTED 0'-6" FROM STRUCTURE TO TOP

OF BOX.

3.02 FIRE ALARM DEVICES FOR FIRE SMOKE DAMPER -

COORDINATE INSTALLATION WITH MECHANICAL WORK.

ENSURE THAT FIRE ALARM DEVICES SHOWN ARE

ACCESSIBLE. PROVIDE REMOTE DUCT DETECTOR TEST

SWITCHES AND COORDINATE LOCATIONS IN FIELD - LOCATE

AT LEVEL V BELOW DUCT DETECTOR LOCATIONS. TYPICAL.

1. FOR ADDITIONAL REQUIREMENTS, REFER TO SHEETS FA5.1.x AND

FA6.1.x SERIES DRAWINGS.

2. ALL FIRE ALARM DEVICES SHALL BE PROGRAMMED BY A CERTIFIED

FIRE ALARM TECHNICIAN.

3. PRIOR TO INSTALLATION OF INTERCONNECTING WIRING BETWEEN

FIRE ALARM DEVICES, SUBMIT SHOP DRAWINGS FOR APPROVAL.

4. PROVIDE FIRESTOP THROUGH WALL AND FLOOR OPENINGS MADE BY

CONDUITS AT RATED WALLS AND FLOORS.

5. COORDINATE SPEAKER INSTALLATION WITH HOSPITAL WIDE PAGING

SINCE THEY ARE DUAL VOICE COIL TYPE.

6. COORDINATE INSTALLATION OF FIRE ALARM DEVICES AND WIRING

WITH OTHER TRADES WHERE FIRE ALARM IS USED TO INTERFACE

WITH BUILDING SYSTEMS, SUCH AS MECHANICAL EQUIPMENT,

DUCTWORK, SECURITY EQUIPMENT, DOOR HARDWARE, SPRINKLER

SYSTEMS, ETC.

DM

FS

DM

RM RM

RM

RM

RM

RM

RM RM

RM

RM

RM

7 8 9 10 11 12 13

A

B

C

D

E

F

G

F A

3.

1.

2A F

A 3.

1.

2A

STAIR 4

U-ST4

VESTIBULE

U-101

SERVICE

ELEVATOR

S02

SERVICE

ELEVATOR

S01

UTILITY

U-100

3.01

3.02 3.03

3.04

3.05

TYPICAL

LA

D

6/30/2017

L

No. E15435

TE

S

TA

AC

T R

EXP

OF

E L E C

L

ER

TE

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/8" = 1'-0"

8' 8' 16'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

SHEET NOTES

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

D

G

B

H

C

F

J

E

KEYNOTES

/1

/2

:0 :0

P

M

FIRE ALARM FLOOR PLAN

LEVEL U

FA3.1.2B

PO KL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/8" = 1'-0"

OVERALL FIRE ALARM FLOOR PLAN LEVEL U

3.01 ?3.01 FIRE ALARM DEVICE MOUNTED 0'-6" FROM STRUCTURE TO TOP

OF BOX.

FIRE ALARM DEVICE FOR BULK MAIN FEED FOR LEVEL V -

COORDINATE INSTALLATION WITH FIRE PROTECTION WORK.

3.02

DUAL MONITOR MODULE FOR SPRINKLER CONTROL VALVE AND

SUPERVISORY SWITCH.

3.03

3.04 FIRE ALARM DEVICES FOR FIRE SMOKE DAMPER - COORDINATE

INSTALLATION WITH MECHANICAL WORK. ENSURE THAT FIRE

ALARM DEVICES SHOWN ARE ACCESSIBLE. PROVIDE REMOTE

DUCT DETECTOR TEST SWITCHES AND COORDINATE

LOCATIONS IN FIELD - LOCATE AT LEVEL V BELOW DUCT

DETECTOR LOCATIONS. TYPICAL.

1. FOR ADDITIONAL REQUIREMENTS, REFER TO SHEETS FA5.1.x AND

FA6.1.x SERIES DRAWINGS.

2. ALL FIRE ALARM DEVICES SHALL BE PROGRAMMED BY A CERTIFIED

FIRE ALARM TECHNICIAN.

3. PRIOR TO INSTALLATION OF INTERCONNECTING WIRING BETWEEN FIRE

ALARM DEVICES, SUBMIT SHOP DRAWINGS FOR APPROVAL.

4. PROVIDE FIRESTOP THROUGH WALL AND FLOOR OPENINGS MADE BY

CONDUITS AT RATED WALLS AND FLOORS.

5. COORDINATE SPEAKER INSTALLATION WITH HOSPITAL WIDE PAGING

SINCE THEY ARE DUAL VOICE COIL TYPE.

6. COORDINATE INSTALLATION OF FIRE ALARM DEVICES AND WIRING

WITH OTHER TRADES WHERE FIRE ALARM IS USED TO INTERFACE WITH

BUILDING SYSTEMS, SUCH AS MECHANICAL EQUIPMENT, DUCTWORK,

SECURITY EQUIPMENT, DOOR HARDWARE, SPRINKLER SYSTEMS, ETC.

3.05 FIRE ALARM DEVICE FOR SPRINKLER SYSTEM - COORDINATE

INSTALLATION WITH SPRINKLER WORK.

EQUIPMENT

1-304

DARK IMAGING

1-318

FREEZER

1-412

GLASS WASH

1-319

TISSUE

1-305

EQUIPMENT

1-310TISSUE

1-306

ELECTRICAL

1-EC1

SIGNAL

1-SC1

IT

1-TC2

ELECTRICAL

1-EC2

SIGNAL

1-SC2

IT

1-TC1

EMERGENCY

ELECTRICAL

1-EC4

MAIN

ELECTRICAL

1-EC3

EQUIPMENT

1-309

EQUIPMENT

1-312

FUME

1-313

TISSUE

1-311

EQUIPMENT

1-315

TISSUE

1-314

STAFF LOUNGE

1-422

COLD ROOM

1-303

SWING

1-317

FUME

1-316

EQUIPMENT

1-307

ADA FUME

1-308

WOMEN

1-221

MEN

1-223

SWING

1-424

CORRIDOR

C1-200

VESTIBULE

1-220A

VESTIBULE

1-220B

CONDENSER

1-302A

EMS RECEIVING

1-501

OFFICE

1-202E

STAIR 3

1-ST3

SERVICE

ELEVATOR

S01

SERVICE

ELEVATOR

S02

PASSENGER

ELEV #1

P01

PASSENGER

ELEV #2

P02

HAC

1-225

OPEN LAB

1-301

STAIR 4

1-ST4

CORRIDOR

C1-210

CORRIDOR

C1-410

CORRIDOR

C1-420

CORRIDOR

C1-400

MECH SHAFT 1

YY

MECH SHAFT 2

ANIMAL

ELEVATOR

LOBBY

1-530

CORRIDOR

C1-500

STORAGE

1-502

STAIR 5

1-ST5

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

MICROSCOPY

1-421

MECH SHAFT

AV-925

SEE SHEET FA3.1.3BSEE SHEET FA3.1.3A

STAFF LOUNGE

1-226

ENTRY LOBBY

C1-100

STAIR 1

1-ST1

CORRIDOR

C1-300

CORRIDOR

C1-300

OPEN LAB

1-301

STORAGE

1-506

EMS TOILET

1-504

HALLWAY

1-302

GOGGLE

ALCOVE

1-220C

ALCOVE

1-220D

CORRIDOR

C1-220

STORAGE

1-220E

LA

D

6/30/2017

L

No. E15435

TE

S T

A

AC

T R

EXP

OF

E L E C

L

E R

T E

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

0'

1/16" = 1'-0"

16' 16' 32'8'

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

301 BATTERY STREET, 7TH FLOOR

SAN FRANCISCO, CA 94111

T 415.227.0100 F 415.908.0862 www.smithgroupjjr.com

The Design Partnership LLP Architects + Planners

1629 TELEGRAPH AVE, #500

OAKLAND, CA 94109

T 415.777.3737 F 415.777.3476 www.dpsf.com

Department of Veterans Affairs

Associate Architect:

TRUE NORTH

PROJ. NORTH

P R

IN

T

E D

O N

KEYPLAN

A

B

D

E

C

/1

/2

:0 :1

P

M

OVERALL FIRE ALARM FLOOR

PLAN LEVEL 1

FA3.1.3

PO NL30 JULY 2015

RESEARCH AND VMU

640-424

SCALE: 1/16" = 1'-0"

OVERALL FIRE ALARM FLOOR PLAN LEVEL 1

C R

CR CR

C R

C R

C R

C R

C R

CR

C R

PPPP

' B

S C

' B

S C

' B

S C

' B

S C

4' BSC 4' BSC4' BSC

' B

S C

' B

S C

INCINC INCINCREF

IN

C

IN

C

IN

C

IN

C

IN

C

IN

C

R E

F R

E F

IN

C

IN

C

R E

F

IN

C

IN

C

IN

C

IN

C R

E F

M F

D I

M F

D I

E W

MF

DI

EW

MF

DI

EW

MF

DI

EW

M F

D I

E W

M F

D I

E W

M F

D I

E W

M F

D I

E W

FS

RM

RM

D H

D H

F S

RM

RM

RM

RM

RM

1 2 3 4 5 6 7

B

C

D

E

F

G

STAIR 3

1-ST3

STORAGE

1-220E

CORRIDOR

C1-220

OFFICE

1-202E

OFFICE

1-202E

CORRIDOR

C1-300

CORRIDOR

C1-200

CORRIDOR

C1-200

CORRIDOR

C1-210

HALLWAY

1-302

CONDENSER

1-302A

OPEN LAB

1-301

OPEN LAB

1-301

HAC

1-225

EQUIPMENT

1-304

MEN

1-223

WOMEN

1-221

VESTIBULE

1-220A

VESTIBULE

1-220B

STAFF LOUNGE

1-226

OPEN LAB

1-301

EQUIPMENT

1-312

TISSUE

1-311

EQUIPMENT

1-310

EQUIPMENT

1-309

ADA FUME

1-308

EQUIPMENT

1-307

TISSUE

1-306ELECTRICAL

1-EC1

IT

1-TC1

SIGNAL

1-SC1

MECH SHAFT 1

YY

COLD ROOM

1-303

TISSUE

1-305

PASSENGER ELEV

#2

P02

F A

3.

1.

3B F

A 3.

1.

3B

FATC (TOP)

FCPS (BOTTOM)

DAA

GOGGLE ALCOVE

1-220C

ALCOVE

1-220D

PASSENGER ELEV

#1

P01

ENTRY LOBBY

C1-100

75cd

75cd

30cd 30cd

15cd

15cd

15cd

15cd

75cd

15cd

15cd

15cd

135cd

30cd

75cd75cd75cd

75cd

15cd

3.01

3.02

3.03

3.04

TYPICAL

3.05

3.05

LA

D

6/30/2017

L

No. E15435

TE

S

TA

AC

T R

EXP

OF

E L E C

L

ER

TE

I G

R E

A P

S U

J. O'

A

R

I

N I F

I C A

O

L

NE

E

ONN

L

L

G R

N E E

I

S P

SOR FE ION

C

GRAPHIC SCALE:

4' 0' 4' 8'

1/4" = 1'-0"

3801 Miranda Ave., Palo Alto CA

CENTERS FOR AMBULATORY CARE,

POLYTRAUMA AND BLIND REHABILITATION

CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

Seals and Signatures on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo…