Project_Drawings_VA_Floodwall_IFC-Part_2of2-140314.pdf
PDF 41 MB Posted
- Attached to
- Flood Perimeter Wall, Manhattan NY
- Solicitation number
- VA10114R0004
About this file
Project Drawings VA Floodwall IFC-Part_2of2-140314
View the file
Other files
| File | Type | Posted |
|---|---|---|
| VA101F-14-C-0020-000.docx | DOCX document | |
| VA101-14-R-0004-A00005000.docx | DOCX document | |
| VA101-14-R-0004-A00004000.docx | DOCX document | |
| VA101-14-R-0004_A00002.docx | DOCX document | |
| Attachments.zip | ZIP file | |
| VA101-14-R-0004-A00002017.pdf | ||
| VA101-14-R-0004-A00002018.pdf | ||
| VA101-14-R-0004-A00002019.pdf | ||
| VA101-14-R-0004-A00002016.pdf | ||
| VA101-14-R-0004-A00002020.pdf | ||
| VA101-14-R-0004-A00002015.docx | DOCX document | |
| VA101-14-R-0004-A00001001.pdf | ||
| VA101-14-R-0004-A00001002.pdf | ||
| VA101-14-R-0004-A00001000.docx | DOCX document | |
| Project_Manual_VA_Floodwall_IFC-140314.pdf | ||
| VA101-14-R-0004_1.docx | DOCX document | |
| Project_Drawings_VA_Floodwall_IFC-Part_1of2-140314.pdf | ||
| VA101-14-R-0004-001.docx | DOCX document | |
| VA101-14-R-0004-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTE:
SYMBOLS SHOWN ARE FOR REFERENCE ONLY
AND DO NOT CONSTITUTE A CHECK LIST OF
DEVICES REQUIRED BY THE CONTRACT
MH
TEL
E
EX
J
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014 083870
PRINTED 02/27/2014
E
EE
ELECTRIC
CONTROL
ROOM
FUEL OIL
ROOM
AIR CONDITIONING PLANT
BUILDING NO. 5
#423 E 23rd. STREET
N/F VETERAN ADMINISTRATION HOSPITAL
MAIN BUILDING
BUILDING NO. 1
MORGUE
NORTH WING
SOUTH WING
CHAPEL
EAST WING
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
CLL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
CLL
C
LL
C
LL
CLLCLLCLL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
CLL CLL CLL
C
LL
C
LL
CLLCLLCLL
C
LL
C
LL
C
LL
CLLCLLCLLCLL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
CLL CLL CLL CLL
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
GATE # 2B
PUMP
STATION
PS-1
PUMP
STATION
PS-2
GATE # 1B
WEDGE # 2
OPERATOR
WEDGE # 2
SAFETY LOOP
GATE # 2A
OPERATOR
GATE # 1A OPERATOR
TYPE
"C"
TYPE
"B"
TYPE
"A"
TYPE "B"
FLOOD GATE # 2
TO PP-1
SEE DWG E601
CONNECTION TO
FLOOD GATE # 1
TO PP-1
SEE DWG E601 2
E501
F4
E501
F6
GATE # 2A
E501
F7
E501
C5
E501
F4
E501
F6
E503
C5
E501
F1 GATE # 1A
E503
F5
SEE NOTE
3SEE NOTE
3SEE NOTE
SEE NOTE
11 FOOT LEAF AND ACTUATOR
120 DEGREE OPENING
19 FOOT LEAF AND ACTUATOR
120 DEGREE OPENING
MORGUE
SOUTH WING
CHAPEL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014 083870
KEYED NOTES:
1. EXISTING DUCTBANK AND CABLE TO BE DEMOLISHED SUBSEQUENT TO
INSTALLATION AND ENERGIZATION OF NEW CABLE.
2. EXISTING 500 KVA PADMOUNT TRANSFORMER. DISCONNECT EXISTING
CABLE AND CONNECT NEW.
3. TO PUMP STATION CONTROL PANEL IN BUILDING NO. 5 SEE DRAWING EP104
FOR CONTINUATION. SEE DRAWING E601 FOR CONDUIT AND WIRE
REQUIREMENTS.
GENERAL NOTES:
1. SEE DRAWING E001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.
2. COORDINATE ALL DOWNTIME WITH VAMC.
3. FOR CONDUIT AND CABLE SCHEDULE SEE DRAWING E502.
GATE # 4B
STATION
PS-3 WEDGE # 3
WEDGE # 4
SAFETY LOOP
EXIT LOOP
GATE # 3A
OPERATOR
WEDGE # 3
OPERATOR
WEDGE # 4
OPERATOR
GATE # 3A (EXIT ONLY)
SEE DETAIL
TYPE
"A"
TYPE
"C"
TYPE "B"
TYPE
"B"
TYPE
"C"
GROUND FLOOR SHOWN.
SEE DRAWING EP104 FOR
FIRST FLOOR POWER PLAN.
NEW MANHOLE
FLOOD GATE # 4
TO PP-1
SEE DWG E601
TO PP-1 SEE DWG E601
FLOOD GATE # 3
MH
E
E
E
SEE NOTE
E503
F1
SEE NOTE
E503
F5
SEE NOTE
SEE NOTE
E501
F9
E501
C5
E501
F4
E501
F6
E501
C5 GATE # 3B
E501
F4
E501
F6
GATE # 4
OPERATOR E501
C5
GATE # 4
E501
C5
SEE NOTE
E
AIR CONDITIONING
PLANT BUILDING NO. 5
EAST WING
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
C
LL
CLL
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014 083870
KEYED NOTES:
1. CONSTRUCT NEW MANHOLE AROUND EXISTING DUCT BANK. DEMOLISH
EXISTING DUCT BANK WITHIN MANHOLE.
2. EXISTING DUCT BANK, EXISTING MANHOLE AND CABLE TO BE DEMOLISHED
SUBSEQUENT TO INSTALLATION AND ENERGIZATION OF NEW CABLE.
3. TO PUMP STATION CONTROL PANEL IN BUILDING NO. 5 SEE DRAWING EP104
FOR CONTINUATION. SEE DRAWING E601 FOR CONDUIT AND WIRE
REQUIREMENTS.
4. EXISTING DUCT BANK TO REMAIN. REMOVE EXISTING CABLE. PROVIDE NEW.
5. UP TO 5KV SWITCH IN EXISTING LOAD BUS J-1. DISCONNECT EXISTING
CABLE AND TERMINATE NEW IN EXISTING SWITCH. SEE DRAWING EP104
FOR CONTINUATION.
GENERAL NOTES:
1. SEE DRAWING E001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.
2. COORDINATE ALL DOWNTIME WITH VAMC.
3. FOR CONDUIT AND CABLE SCHEDULE SEE DRAWING E502.
STATION
PS-4
WEDGE # 5
WEDGE # 5
OPERATOR
BI-DIRECTIONAL
VEHICLE SENSOR
LOOPS (TYP)
GATE # 5B
TYPE
"C"
TYPE
"B"
TO PP-1 SEE DWG E601
FLOOD GATE # 5
E501
F4
E501
F6
GATE # 5A
E501
F7
GATE # 5A
OPERATOR E501
C5
SEE NOTE
FUEL OIL
ROOM
ELECTRIC
CONTROL
ROOM
NORTH WING
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014 083870
KEYED NOTES:
1. TO PUMP STATION CONTROL PANEL IN BUILDING NO. 5 SEE DRAWING EP104
FOR CONTINUATION. SEE DRAWING E601 FOR CONDUIT AND WIRE
REQUIREMENTS.
GENERAL NOTES:
1. SEE DRAWING E001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.
2. FOR CONDUIT AND CABLE SCHEDULE SEE DRAWING E502.
TO PUMPING STATIONS
PS-1, PS-2, PS-3, PS-4
TO PP-1 SEE
DWG E601
PP-2
PP-1
TO PP-1 SEE
DWG E601
TO FLOOD
GATE # 1-5
PC-D
PC-A
PC-B
EXISTING 480/277V
POWER CENTER
EXISTING 208/120V
POWER CENTER
EXISTING 208/120V
POWER CENTER
PC-C
MER
BUILDING
MANAGEMENT
OFFICE
EXISTING PRIMARY
SERVICE SWITCHGEAR
EXISTING PRIMARY
SERVICE SWITCHGEAR
LOAD BUS
"J-1"
EXISTING 208/120V
POWER CENTER
RP T1
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
BACK BOX
EXTENSION RING (IF REQUIRED)
FLUSH MOUNTED CAMERA, SPEAKER PHONE,
CARD READER MOUNTED TO RECESSED BACK
BOXES SUPPLIED BY OR IN ACCORDANCE WITH
MANUFACTURER'S REQUIREMENTS.
1" RGS CONDUIT
CARD READER
HANDS-FREE
SPEAKER PHONE
AUTOMOBILE
HEIGHT
DEVICES
TRUCK HEIGHT
DEVICES
NOTES:
1. THIS DETAIL IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EXACT DIMENSIONS OR
INSTALLATION DETAILS. CONTRACTOR SHALL PROVIDE ALL COMPONENTS, FITTINGS, AND
ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION AND SHALL PROVIDE EXACT
DIMENSIONS AND INSTALLATION DETAILS IN SHOP DRAWINGS.
2. DEVICES SHOWN ARE TO BE FLUSH MOUNTED IN A MASONRY WALL. PROVIDE MASONRY
CONTRACTOR WITH EXACT DIMENSIONS, PRODUCTS AND SHOP DRAWINGS REQUIRED
FOR COORDINATION WITH MASONRY CONTRACTOR PRIOR TO CONSTRUCTION OF WALL.
3. ARCHITECTURAL COMPONENTS SHOWN ARE GENERIC. FOR PROJECT SPECIFIC
CONDITIONS AND CONSTRUCTION DETAILS SEE DETAIL B3 ON DRAWING CS504.
SEE DETAIL F5/CS501 FOR ADDITIONAL INFORMATION
WIRING TO BE RUN IN LIQUID TIGHT FLEXIBLE CONDUIT CONCEALED IN FENCE POST.
WIRING TO BE RUN PVC CONDUIT IN UNDERGROUND CONCRETE DUCT BANK.
RIGID GALVANIZED CONDUIT RUN EXPOSED, MOUNT TO FENCE POST.
ENTRY OPERATION: PRESENTATION OF A VALID CARD TO CARD READER SHALL ENERGIZE
LOCK RELEASE AND BYPASS DOOR STATUS ALARM FOR PROGRAMMED PERIOD OF TIME.
EGRESS OPERATION: PANIC HARDWARE PUSH BAR MECHANICALLY UNLATCHES DOOR
WITHOUT DEPENDENCE ON ELECTRONICS. PANIC HARDWARE SHALL PROVIDE UNDELAYED
EGRESS AT ALL TIMES WHETHER OR NOT ENTRY SIDE IS IN LOCKED POSITION. REX SWITCH IN
PANIC HARDWARE SHALL BE WIRED TO SECURITY SYSTEM TO BYPASS DOOR ALARM FOR
PROGRAMMED PERIOD OF TIME WHENEVER PANIC HARDWARE PUSH BAR IS ACTIVATED.
ELEVATION AT EGRESS SIDE ELEVATION AT ENTRY SIDE
CARD READER CONTROLLED PEDESTRIAN GATE NOTES:
EXTERIOR MASONRY WALL WITH FLUSH MOUNTED SECURITY DEVICES.
PROVIDE MASONRY CONTRACTOR WITH EXACT DIMENSIONS,
PRODUCTS AND SHOP DRAWINGS REQUIRED FOR COORDINATION
WITH MASONRY CONTRACTOR PRIOR TO CONSTRUCTION OF WALL.
ARCHITECTURAL DETAILS AND COMPONENTS SHOWN ARE GENERIC.
FOR ACTUAL PROJECT SPECIFIC CONDITIONS AND CONSTRUCTION
DETAILS SEE CS500 SERIES DRAWINGS.
SURFACE MOUNTED DOME HOUSING
WEATHERPROOF TWO GANG BACK
BOX WITH EXTENSION RING FOR
FLUSH MOUNTING
FASTEN TO WALL USING STAINLESS
STEEL FASTENERS
APPLY SILICONE SEALANT BETWEEN
MOUNTING BRACKET AND WALL
CONDUIT TO NEAREST
EXISTING BUILDING
NOTES:
3" 3"
18"
3" 3"
1" 1"
3"
6'-0"24"
24"
SQUARE STEEL 15' HIGH
POLE BLACK POLYESTER
POWDER COAT FINISH ENVIRONMENTAL DOME
STYLE CAMERA MOUNTED
AT TOP OF POLE
BASE COVERPLATE ANCHOR BOLTS,
NUTS AND TEMPLATES SHALL BE
PROVIDED WITH POLE.
120V WIRING IN POLE SHALL BE RUN
IN ARMORED CABLE
GROUND CLAMP TO POLE AND
CONDUITS.
RIGID GALVANIZED STEEL CONDUITS
STUB-UP IN POLE 6"
GROUT SHALL BE PACKED UNDER
POLE TO ASSURE FULL CONTACT
WITH BASE.
ANCHOR BOLTS.
#6 BARE COPPER GROUND
CONDUCTOR RUN IN 3/4" RGS
CONDUIT THERMOWELD TO
GROUND ROD
3/4" X 10'-0" GROUND ROD
8 # 5 VERTICAL REINFORCING
RODS WITH # 3 TIES ON 12"
CENTERS
PVC CONDUIT
ROUND
CONCRETE
BASE
FINISHED GRADE
HANDHOLE
PAN/TILT CAMERA (TRUCK & AUTO)
TILT RANGE -45 DEG TO +10DEG
SEE DETAIL C2 THIS DRAWING
HANDS-FREE
SPEAKER PHONE
(SECURITY CALL
STATION)
CARD READER
1"PVC CONDUIT IN CONCRETE
DUCT BANK FOR CARD
READER CABLES
1" PVC CONDUIT IN
CONCRETE DUCT
PAN/TILT CAMERA
PAN/TILT CAMERA
LOCKING PIN
ASSEMBLY SIDE VIEW
MINIMUM POST SIZE 4" DIAMETER
CONTROL & PUMP PANEL LOCATE
REMOTELY A MAXIMUM OF 100' FROM
GATE
PADLOCK AND HASP AND STAPLE
OPEN/CLOSE/STOP PUSH BUTTON
GATE CONTROL PROTECTED BY
LOCKABLE COVER
2" CONDUIT (PVC) FOR HYDRAULIC HOSES
1" CONDUIT FOR LIMIT SWITCHES CONDUIT TO WEDGE CONTROL CABINET (WHERE REQUIRED) - SEE
PLANS FOR SPECIFIC REQUIREMENTS AT EACH GATE LOCATION
CONDUIT TO PANELBOARD FOR PRIMARY POWER
CONDUIT CONTROL WIRING TO SECURITY SYSTEM
FLOOD WALL
W
IP
R
W
A L L
FLOOD GATE
PROVIDE 120 VOLT WIRING
FROM WEDGE CONTROL
CABINET
PVC CONDUIT
12"DIA X 36" DEEP
CONCRETE BASE
ANCHOR BOLTS
FINISHED GRADE
GROUND CLAMP TO
PEDESTAL AND
CONDUIT
RED/GREEN TRAFFIC
LIGHT SPECIFIED UNDER
SECTION 34 75 13.13
PROVIDE 3-1/2" DIAMETER
STEEL POLE POLYESTER
POWDER COAT PAINT
BLACK FINISH
72"
3-1/2"
4" 4"
24" 36"
12"
RIGID GALVANIZED
STEEL CONDUIT
RIGID GALVANIZED
STEEL CONDUIT
RIGID GALVANIZED
STEEL CONDUIT
1"PVC CONDUIT IN CONCRETE DUCT
BANK FOR SECURITY CALL STATION
AND CAMERA CABLES
RIGID GALVANIZED
STEEL CONDUIT
RIGID GALVANIZED
STEEL CONDUIT
1" PVC CONDUIT IN
CONCRETE DUCT
BANK
RIGID GALVANIZED
STEEL CONDUIT
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
B
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
REMOVE EXISTING LIGHT
POLE AND RELOCATE
EXISTING CIRCUIT
REMOVE EXISTING LIGHT
POLE AND RELOCATE
EXISTING CIRCUIT
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson 01/30/2014
REMOVE LIGHT POLE
AND RELOCATE
EXISTING CIRCUIT
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
FULLY SPRINKLERED
Henningson, Durham & Richardson, Architecture and Engineering, P.C.
500 Seventh Ave, 11th Floor, New York, NY 10018 . 212-904-1212
WARNING: This warning is required to be included on this document under New York State Education Law, Article 145, Section 7209, Sub-paragraph 2. It is a violation of the aforementioned law for any person, unless acting under the direction of a licensed professional engineer or land surveyor, to alter any portion of the design set forth on this document. If any item of the design set forth in this document is altered, the altering engineer or land surveyor shall affix to the item his/her seal and the notation "altered by" followed by his/her signature and the date of such alteration and a specific description of the alteration.
Dale G. Peterson XX/XX/2014 083870
STIRUPS SEE STRUCTURAL DETAIL
File details come from the government source that posted it. Updated .