ADDITITIONAL INFORMATION PERTINENT TO THIS REQUIREMENT
SG24JUN227543
THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR SG24JUN227543; MEANING THAT THE
PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN-HOLES, CONDUIT, CENTRAL OFFICE
LOCATIONS), AND FIBER BUILDS. ADDITIONALLY, AS A MINIMUM MUST HAVE 50 METERS PHYSICAL
SEPARATION FROM TSR SG24JUN227542.
THE TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT DRAWINGS FOR TECHNICAL
REVIEW SHOWING THE ROUTE FROM THE COMMERCIAL DEMARCS TO THE SUPPORTING CENTRAL
OFFICES AND/OR WIRING CENTERS. DRAWINGS MUST INCLUDE TOTAL FIBER MILES AND ROUND-TRIP DELAY (RTD). ADDITIONALLY, THE VENDOR IS TO PROVIDE DITCO WITH DETAILED CIRCUIT/PATH CONNECTIVITY DIAGRAMS, IN KMZ OR KML FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FOR PROPOSAL EVALUATION AND AS A FINAL RECORD OF THE INSTALLED PATH. THESE DIAGRAMS MUST BE
PROVIDED TO DISA HQ IE16 (DISA.MEADE.IE.MBX.IE16-PROVISIONING-TEAM@MAIL.MIL) FOR
HISTORICAL PURPOSES.
SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.
SINGLE MODE FIBER MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT THE GOVERNMENT
CAN CHANGE/REVISE CHANNELIZATION WITHOUT TELECOM PROVIDER INTERVENTION.
A. NOTE 1 (JITTER): IN A STEADY-STATE CONDITION, THE PATTERN OF SYNCHRONOUS TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN THE POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES PER DAY), THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO- END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR LESS PER HOUR.
ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE) OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000) NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.
B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION SERVICES FOR RATES OF 10GBPS SHALL BE IN ACCORDANCE WITH ITU-T RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) & TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH TRANSMISSION SERVICE SHALL NOT INHIBIT GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, ATM, GIGABIT ETHERNET, AND ENCRYPTION.
THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL PAYLOAD, PATH AND LINE
OVERHEAD BYTES TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT MONITORING SDP TO
SDP. THERE SHALL NOT BE ANY LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND SDP.
C. SINGLE MODE FIBER MUST BE TERMINATED TO THE LINE SIDE OF THE FIBER TERMINATING PATCH
PANEL INSTALLED AT BOTH DISA IE1 PROVIDED SERVICE DELIVERY NODE LOCATIONS.
D. THE TELECOM PROVIDER MUST CONTACT DISA GOC TIER-II ENGINEERING UPON RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS. PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL:
DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEASE-BB-T@MAIL.MIL. ALT POC:
ORGANIZATIONAL NUMBER (CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691
EMAIL: DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
ONCE TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THEIR FIBER DISTRIBUTION PANEL INSTALLED IN THEIR DWDM EQUIPMENT SUITE TO THE GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ -3 TO -9 LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE OF COMPLETION
(NOC) SENT TO DITCO.
***THE VENDOR MUST TERMINATE SINGLE MODE FIBER AT BOTH LOCATIONS IAW UNIQUE
INSTALLATION FACTORS.***
THE SINGLE MODE FIBER MUST PASS A DOCUMENTED SATISFACTORY 72-HOUR END TO END TEST IAW
ITU STANDARD M.2101 PRIOR TO TURN-UP TO THE GOVERNMENT.
REMARKS:
1. VENDOR MUST MEET SVC DATE.
2. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: SINGLE-MODE INTERFACE
REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,
PHYSICAL CONNECTOR, 10 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991
(R2003). ALL OPTIONS DEFINED SC CONNECTOR, SINGLE-MODE FIBER PER
ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).
(B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN
DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED.
(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO CIRCUIT.
(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS.
(F) NO NETWORK INTERFACE UNIT.
(G) DEDICATED PATH.
(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
(I) THE VENDOR MUST CONDUCT A 72-HOUR SATISFACTORY END TO END TEST ON THE 10GB WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW.
(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER.
(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE
GOVERNMENT BY THE DGOC:
PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB
TEAM
PHONE: (C) 618-418-9813, (D) 418-9813
EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEAS
E-BB-T@MAIL.MIL
ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT ACTIVATIONS)
PHONE: (C) 618-418-8691, (D) 418-8691
EMAIL: DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
(L) THE VENDOR MUST PROVIDE THE LONG-HAUL CIRCUIT NUMBER AND THE
1-800 TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO
THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE
COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO
THE GOVERNMENT.
3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
SINGLE MODE FIBER IAW UNIQUE INSTALLATION FACTORS.
4. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION
FACTORS.
5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN
ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER
LOCATIONS.
6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR
CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR
EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER
CONTACT CENTER (DCCC) SCOTT AFB, IL. TOLL FREE: 1-855-868-9500,
COML: 618-418-9500, DSN: 312-418-9500.
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 10GB.
LINE CODE: NRZ.
FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003).
1. TEST AND ACCEPTANCE: FIBER OPTIC 10GB WAVE CIRCUITS SHALL PASS
A FULLY DOCUMENTED SATISFACTORY SOAK TEST BY THE GOC AT SCOTT
AFB, IL. PRIMARY: (C) 618-418-8691, (D) 418-8691.
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE
FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION:
NON-DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO
99.5% OR BETTER.
MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN OR EQUAL
TO 9%.
ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.
SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5 X
10-6.
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR
EQUAL TO 1 PER 72 HOURS.
JITTER: SEE NOTE 1 (JITTER).
BER: LESS THAN OR EQUAL TO 1X10-12.
DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) *
WHERE "D" IS THE SDP-TO-SDP TRANSMISSION DISTANCE, MEASURED
SHORTEST GREAT CIRCLE, IN KILOMETERS.
3. ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK WILL BE
MEASURED IN MILLISECONDS FROM THE CUSTOMER'S SERVICE DELIVERY
POINT (SDP) SITE-A TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP)
SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS
TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE GOVERNMENT
ACCEPTING AUTHORITY WILL CONFIRM THE RTD DURING THE TURN-UP AND
TEST PHASE AND IF IT DOES NOT ALIGN WITH THE CONTRACTORS
PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.
DISN BACKBONE ACTIVATIONS:
EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEASE-BB-T@MAIL.MIL.
FOR CIRCUIT INSTALLATION:
ASSISTANCE WITH THE COMMERCIAL LEASED PATH, CONTACT DCP
COMMERCIAL ACTIVATION TEAM (CAT) AT D312-850-0820,
C614-692-0820.
THE VENDOR MUST CONTACT DISA GOC TIER-II ENGINEERING 48 HOURS PRIOR TO BEGINNING THEIR
END-TO-END TESTING. PHONE: (C) 618-418-8627, (D) 418-8627.