NASA Glenn Research Center requires the purchase of two Acumentrics UPS units and associated cables for research flight experiments on the NASA PC-12 aircraft at Armstrong Flight Research Center (AFRC). The UPS units will serve as critical power-conditioning and backup systems for flight research hardware during airborne operations. Each unit must be certified to MIL-STD-810G, MIL-STD-461F, RTCA/DO-160G, and MIL-HDBK-704-3 standards, with input voltage capability for both 120 VAC (60 Hz) and 28 VDC. Output specifications include 1500 VA and 1250 W, with the ability to be combined in parallel with another unit to provide 3000 VA and 2500 W. Units must feature Lithium Iron Phosphate (LFP) batteries capable of 10 minutes runtime at 1250 W, remote shutoff switch capability, and must fit within a standard 19-inch server rack at 1U height. The procurement includes two UPS units (part number ANG1501U28.5KPNLIC1), two DC output cables (ANG9004F), two DC input cables (ANG9001F), two AC output cables (ANG9054F), and one parallel cable (ANG9047C1). The place of performance is NASA Glenn Research Center in Cleveland, Ohio, with a period of performance of 30 days after receipt of order (ARO).

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

This requirement is for the acquisition of the Acumentrics UPS for NASA Glenn Research Center (GRC). The information listed below is required to complete this purchase.

2. Background

NASA’s Glenn Research Center seeks the purchase of two Uninterruptible Power Supplies (UPS) and required accessories (cables) for research flight experiments on the NASA PC-12 aircraft at Armstrong Flight Research Center (AFRC). The UPS units will serve as critical power-conditioning and backup systems for flight research hardware, ensuring stable, uninterrupted power during airborne operations.

3. Characteristics, Scope, and Specs

Each UPS needs to have the specifications listed below and the manufacturer must have a history of airworthiness approval at AFRC.

• Certified to appropriate sections of MIL-STD-810G, MIL-STD-461F, RTCA/DO-

160G, MIL-HDBK-704-3.

• Input voltage: 120 VAC (60 Hz) and 28 VDC

• Output Power: 1500 VA and 1250 W (also needs to be capable of being combined in parallel with another unit to provide 3000 VA and 2500 W)

• Output voltage: 120 VAC (60 Hz) and 28 VDC

• Lithium Iron Phosphate (LFP) batteries capable of 10 minutes runtime at 1250 W

• Remote shutoff switch capability

• Must fit within standard 19” server rack and be 1U height each

QTY PART # DESCRIPTION

2 ANG1501U28.5KPNLIC1 1U UPS, 1250W, AC/DC IN - AC/DC OUT,

N+1, SNMP; LFP BATTERY,

WEATHERPROOF OPTION, ANG1501

SERIES

2 ANG9004F ACCESSY, CABLE, DC OUTPUT, 10FT,

ANG1251 SERIES, FUNGUS MITIGANT

2 ANG9001F ACCESSY, CABLE, DC INPUT, FUNGUS

MITIGATION WITH EXTRUDED OR

TAPED WHITE PTFE, 1U SERIES

2 ANG9054F ACCESSY, CABLE, AC OUTPUT,

FUNGUS MITIGATION WITH

EXTRUDED OR TAPED WHITE PTFE, 1U

SERIES

1 ANG9047C1 ACCESSY, PARALLEL CABLE, 1U,

FUNGUS MITIGATION

4. Place of Performance

NASA Glenn Research Center (GRC) ATTN: Matthew Fakler, BLDG 309, RM 212

Cleveland, OH 44135

5. Period of Performance

30 days ARO