Text version
SCOPE OF WORK
Mississippi Air National Guard – Hawkins Field
1. PROJECT DATA:
TITLE: Dismantle of exiting racking and Purchase and Install one (1) Vertical Carousel
BUILDING/FACILITY: Mississippi Air National Guard
PROJECT DURATION: 90-120 days
2. GENERAL SCOPE:
The Contractor shall provide all supervision, labor, materials and equipment to dismantle existing racking and purchase and install one (1) each Vertical Carousels to support this requirement.
The contractor shall install the Carousel system at the Mississippi Air National Guard The end user is responsible for providing electrical power to the unit. The contractor will provide final electrical hookup connections from the unit motor to the electrical disconnect.
3. DETAILED REQUIREMENTS (Vertical Carousels):
Vertical Carousel must be of Ergonomic Design All Vertical Carousels must be “Clip System” panel concept for fast assemble/disassemble and for maintenance purposes allowing for high operator security in the event that stored goods fall inside the unit.
All Vertical Carousels shall come with a lifetime warranty of the motor to assure years of reliable usage. All other components carry a 2-year warranty, including transportation, parts and labor.
Vertical Carousels shall come equipped with an Emergency Power Crank for access to parts in case of power failure
Vertical Carousels shall come equipped with a stainless-steel table surface at a standing position.
Vertical Carousel shall have an imbalance indicator located on the operator station display that will alert the operator to any imbalance load.
Vertical Carousels shall come equipped with a lockable lightweight one-piece sliding door.
Self-counterbalanced sliding door can be opened and closed with minimal effort. Two-piece sliding doors without counterbalance are not acceptable.
Vertical Carousels must have 100% Reliable Safety Security System Vertical Carousels shall come equipped with finger protection safety buffer at rear of posting board.
Vertical Carousels must come with transport rollers for fast and easy repositioning in the case of internal moves, providing maximum flexibility for unit positioning with minimum downtime and reinstallation costs.
Vertical Carousels must have standard manual override systems allowing for the unit to be used if need until service technician’s repair.
Vertical Carousels must have a standard manual controller override that can be operated with the door open, so parts can be located using “drive and view” without having to know what carrier the part is stored on if the controller is inoperable until a service technician can perform the repair.
Unit will come with 836 Storage Tote 17-7/8" x 8-3/8 x 6, Blue. Totes will come with 2 adjustable dividers.
4. DETAILED SOFTWARE REQUIREMENTS:
All software provided must be developed and owned by the carousel manufacturer.
Vendor’s software must give the customer the ability to create users with different rights and abilities based on their passcode protected login.
Software must have the optional ability to interface with existing customers host network.
Software database must be able to be installed onto customer’s network for backup and information access reasons.
Software must be able to be installed and run on commercially available computer hardware.
Software support must be included in the price of the contract for the first 2 years.
5. DETAILED VENDOR REQUIREMENTS:
Contractor services shall be offered through an office that has a 24-hour turn-around time and must be assured and guaranteed on all requests for service. The installation and service must be performed by factory trained and authorized qualified individuals.
Contractor must include Preventive Maintenance Services every 6 months for the duration of the 2-year warranty period in the price of the contract for the equipment.
The contactor must ensure the equipment complies with DIN EN 15095 “Power-operated mobile racking and shelving, carousels and storage lifts” and has been tested and certified by TÜV (Technical Observation & Control), a USA NRTL and a Canadian CB.
The manufacture must be certified ISO 9001.
The manufacture must be certified ISO 14001
6. OVERALL EQUIPMENT SPECIFICATION:
Vertical Carousel (VCM):
Overall Unit Height: 28 ft - 10.9 in.
Minimum Room Height for Installation: 29 ft - 0.9 in Overall Unit Width: 10 ft – 1.1 in.
Overall Unit Depth: 4 ft – 103 in.
Excludes 12.6 in. (320 mm) Work Counter Cubic Storage per Unit: 640.1 ft³ Storage Area per Unit: 1057.7 ft² Unit Weight (Empty): 14230 lb.
Unit Weight (Loaded): 32593 lb.
Maximum Imbalance Load: 2646 lb.
Cycle Speed: 4.92 in./sec.
Access Time: 31.9 sec (1/4 Revolution) Power Supply: 3/PE 208V (50/60 Hz) Rated Operating Current: 5.8 A Motor Power: 3 HP ; 2.2 kW Fuse Protection: 8 A t Power Consumption: 4.8 kVA Controller Location: End Frame, Right Side E-Stop Location: (1) per Side Panel (2 Total) Controller: OPLogicontrol Table Height 39.37 in, Stainless Steel / Fixed Work Counter Access Opening Light Table Height: 39.37” Door Type: Manual Carriers per Unit: (38) Multipurpose Carriers Spacing (Pitch): 16.5 in.
Each carrier will have one (1) non- reinforced shelf with four (4) supports with shelf spacing at 7.03” and 7.07 clear shelf heights.
Carrier Clear Height: 14.02 in. Includes: 0.31 in. front lip Carrier Clear Width: 96.5 in.
Carrier Clear Depth: 20.8 in.
Carrier Capacity per level (max): 360 lbs.
END SCOPE OF WORK