SPI_AK15820325.pdf
PDF 49 KB Posted
- Attached to
- Transmission
- Solicitation number
- SPRDL1-18-R-0479
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SPRDL118R0479.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.
FORM APPROVED
OMB No. 0704-0188
2520-01-582-0325 03/09/10
AK15820325
4. NATIONAL STOCK NO.
2. CAGE 3. SPI NO.
6. REVISION 5. DATE
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE
-MB
WEATHERIS
SPECIAL PACKAGING INSTRUCTION
57K7251 (19207) TRANS W/CONTAINER 19207
1 EACH NONE 1477.0 0053.695
MIL-STD-2073-1D, METHOD 55
MIL-STD-2073-1D
MIL-STD-2073-1D
10. UNIT PACK CU. (CU. FT.) 11. UNIT PACK SIZE (IN)
12. MILITARY PRESERVATION
17. NOTES / DRAWING
15. PACKING
14. DRYING
13. CLEANING
7. QUP 8. ICQ 9. UNIT PACK WT. (LB)
20.
DESCRIPTION
18.
STEPS
19.
REQ'D
CONSISTS OF: 1 EA. DRESSED TRANSMISSION, P/N 12512471, CAGE 19207
1 EA. REUSABLE CONTAINER, P/N 12436544-1, CAGE 19207
A. QUALITY ASSURANCE PROVISIONS:
1. INSPECT THE PRESERVATION AND UNIT PACK IN ACCORDANCE WITH MIL-STD-2073-1D.
2. INSPECT THE CONTAINER IN ACCORDANCE WITH A-A-52462, INCLUDING THE FIRST ARTICLE INSPECTION
REQUIREMENT.
B. FILL TRANSMISSION TO OPERATING LEVEL. ROTATE MECHANISM TO ENSURE 100% COVERAGE OF PRESERVATIVE ON INTERNAL SURFACES. REMOVE DRAIN PLUG AND DRAIN EXCESS PRESERVATIVE.
REPLACE DRAIN PLUG SECURELY.
( NOTE: IF TRANSMISSION HAS BEEN PREVIOUSLY RUN BY THE MANUFACTURER AND ALL INTERIOR
SURFACES HAVE BEEN COATED WITH THEIR APPROVED LUBRICANT, NO ADDITIONAL INTERNAL
PRESERVATION IS REQUIRED)
C. APPLY TO UNPAINTED, UNPLATED FERROUS SURFACES.
D. PLACE INTO DESICCANT BASKET AND CLOSE DESICCANT PORT COVER.
E. THE UNIT CONTAINER IS THE SHIPPING CONTAINER.
F. SPECIAL MARKING SHALL BE APPLIED AS FOLLOWS;
TRANSMISSION ASSY SERIAL NUMBER SHALL BE STENCILLED ON THE CONTAINER IN ACCORDANCE WITH
MIL-STD-129.
MIL-STD-2073-1D & NOTE E
NOT APPLICABLE
MIL-STD-129 AND NOTE F
058.0 040.5 039.5X X
b. LEVEL B
16. MARKING
a. LEVEL A
1-B
2-C
3-D
4-E
PRESERVATIVE: MIL-PRF-2104, GRADE 15W-40.
PRESERVATIVE: MIL-PRF-16173, GR 4.
DESICCANT: MIL-D-3464, TY I (56 UNITS)
CONTAINER: P/N 12436544-1
DD FORM 2169, JUN 1997 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 1 Pages
File details come from the government source that posted it.