DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 1 Pages

SPECIAL PACKAGING INSTRUCTION

Form Approved OMB No. 0704-0188

XJO

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

N1388 (76761) GENERATOR, DIRECT CURRENT 19207 AK15455921

4. NATIONAL STOCK NUMBER 5. DATE OF REVISION 6. REVISION

6115-01-545-5921 JANUARY 14, 2016

7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)

1 EA. NONE 81.0 est. 1.278 est. 14.5 X 14.5 X 10.5 est.

12. MILITARY PRESERVATION (METHOD) 18.

STEPS

19.

REQ’D

20.

DESCRIPTION

MIL-STD-2073-1D, METHOD 42 1-B PRESERVATIVE: MIL-PRF-32033

13. CLEANING

MIL-STD-2073-1D 2-C 1 WRAP: MIL-PRF-121, TYPE I

14. DRYING

MIL-STD-2073-1D 3-D CUSHIONING: ASTM-D 4727, TYPE CF, CLASS DOM

15. PACKING 4-E 1 CONTAINER: ASTM-D 5118, TYPE CF, CLASS DOM

a. LEVEL A

MIL-STD-2073-1D AND NOTE G 5-F 1 BAG: MIL-DTL-117, TY. I, CL. E, ST. 1

b. LEVEL B

MIL-STD-2073-1D AND NOTE G 6-E 1 CONTAINER: ASTM-D 5118, TYPE CF, CLASS WR

16. MARKING

MIL-STD-129

17. NOTES / DRAWING

A. INSPECT THE PRESERVATION AND UNIT PACK IN ACCORDANCE WITH MIL-STD-2073-1D.

B. APPLY PRESERVATIVE TO UNPAINTED, UNPLATED FERROUS SURFACES.

C. SINGLE WRAP REQUIRED. DETERMINE SIZE OF WRAP IN ACCORDANCE WITH MIL-STD-2073-1D.

D. FIBERBOARD FILLER PADS AND / OR DIECUTS SHALL BE DEVISED AND USED TO IMMOBILIZE THE GENERATOR AND

PREVENT DAMAGE TO THE GENERATOR OR CONTAINER.

E. CLOSE CONTAINER IN ACCORDANCE WITH AN APPROPRIATE METHOD OF ASTM D1974.

F. DETERMINE SIZE OF BAG IN ACCORDANCE WITH MIL-STD-2073-1D. CLOSE BAG BY HEAT SEALING.

G. PACKING:

LEVEL A PACKING SHALL BE ACCOMPLISHED USING WOOD-CLEATED PANELBOARD SHIPPING BOXES, CONFORMING TO ASTM-D 6251, TYPE III, CLASS 2 OR NAILED WOOD BOXES CONFORMING TO ASTM-D 6880, CLASS 2.

LEVEL B PACKING SHALL BE ACCOMPLISHED USING FIBERBOARD BOXES, WEATHER RESISTANT, CONFORMING TO ASTM-D 5118 OR TRIPLEWALL, CORRUGATED FIBERBOARD BOXES, CLASS 2, CONFORMING TO ASTM-D 5168.

CLOSURE, SEALING, AND REINFORCEMENT SHALL BE IAW SPECIFIC, APPLICABLE METHODS OF ASTM-D 1974, OR AS

REFERENCED IN THE CONTAINER SPECIFICATION.

WHEN THE TOTAL QUANTITY TO BE SHIPPED TO THE SAME DESTINATION EXCEEDS 125 POUNDS, EXTERIOR PACKS

WITHOUT SKIDS SHALL BE PALLETIZED IN ACCORDANCE WITH MIL-STD-147.