PGC 09140 tech data

28 KB Posted

Attached to
Univewrsal All Weather Coats Core Group Federal contract opportunity
Solicitation number
SPM1C1-08-R-0153
Issued by
Defense Logistics Agency Troop Support Clothing and Textiles

About this file

Tech Data for Men's Navy All Weather Coat

Text of this file

COAT, ALL-WEATHER, MAN'S, W/ REMOVE. LINER

BLUE 3346, WATER REPELLENT

ADDITIONAL INFORMATION FOR A-A-50367:

PATTERN DATE: 31 JAN 2003

STANDARD SAMPLE FOR CLOTH, POPLIN: POLYESTER AND

COTTON (WATER REPELLENT), BLACK 385

CONFORMING TO A-A-50531, IS AVAILABLE ON ROLL

NO. 3668 AND APPLICABLE FOR SHADE ONLY.

NOTE: THROAT TAB BUTTONS- ONE BUTTON SHALL BE

POSITIONED ON EACH SIDE OF THE COLLARSTAND,

POSITIONED TO ALIGN WITH THE TAB BUTTONHOLE WHEN

TAB IS EITHER THE STAY OR CLOSED POSITION.

NOTE: TOPSTITCHING - TOPSTITCHING SHALL BE

LOCATED ON THE SLEEVE TABS, EPAULETS, POCKET

WELTS, FACING TAB, COLLAR, SLEEVE OUTSEAMS, SIDE

SEAMS, BACK SEAM, FRONT EDGE OF FLY, LEFT AND

RIGHT FRONT EDGE (INCLUDING FACING AREA AROUND

HEM", AND TOP PORTION OF SET IN AND RAGLAN

SLEEVES.

INTERIM CHANGES TO A-A-50367A:

PAGE 1, DESCRIPTION:

- LINE 6, AFTER "SEAM", INSERT "(+0, -1/4)".

- LINE 7, AFTER "SHOULDER SEAM." INSERT "THE

COLLARS SHALL BE OF ROUNDED CONSTRUCTION."

LINE 9, AFTER "SLITS" ADD "THE CORNERS OF THE

WELTS SHALL BE BACKTACKED DIAGONALLY THREE TIMES

SUPERIMPOSED ON EACH OTHER BETWEEN THE

DOUBLE STITCHING."

LINE 15, DELETE "3/8 INCH" AND SUBSTITUTE "1/4

INCH"; AT END ADD "THE SHOULDER EPAULET AND

LAPEL BUTTONHOLES SHALL BE EYELET END, SQUARE

BAR BUTTONHOLES."

PAGE 1, SIZES: LINE 2, DELETE "AND 52" AND

SUBSTITUTE "52 AND 54"

PAGE 1, BASIC MATERIAL: DELETE FIRST

SENTENCE AND SUBSTITUTE, "THE BASIC MATERIAL FOR

THE COAT SHALL BE A BLEND OF 65 +/-3 PERCENT AND

35 +/- 3 PERCENT COMBED AND/OR CARDED COTTON

WATER REPELLENT TREATED POPLIN FABRIC, ARMY

SHADE 385 CONFORMING TO A-A-50531"

PAGE 2, AFTER PARA. "BASIC MATERIAL" ADD PARA.

"TOXICITY. THE CLOTH SHALL SHOW NO TOXICITY WHEN

TESTED USING THE METHODS BELOW:

A) TITLE 40, CODE OF FEDERAL REGULATIONS, 1994

EDITION

SECTION 798.4100 - DERMAL SENSITIZATION

SECTION 798.4470 - PRIMARY DERMAL IRRITATION

SECTION 798.4500 - PRIMARY EYE IRRITATION

MARZULLI, F & H. MAIBACH "CONTACT ALLERGY:

PREDICTIVE TESTING IN HUMANS",

ADVANCES IN MODERN TOXICOLOGY, VOLUME 4,

PG. 353-372, 1977

B) AS AN ALTERNATIVE TO ANIMAL AND HUMAN TESTING

THE CONTRACTOR MAY PROVIDE INFORMATION WHICH

CERTIFIES THAT THE CLOTH IS COMPOSED OF

CHEMICALS AND/OR MATERIALS WHICH HAVE BEEN

SAFELY USED COMMERCIALLY WHERE PROLONGED SKIN

CONTACT HAS OCCURRED."

PAGE 2, LINER MATERIAL: LINES 1 AND 2. DELETE

FIRST SENTENCE AND SUBSTITUTE: "THE MATERIAL

FOR THE REMOVABLE LINER SHALL BE POLYESTER FIBER

PILE WITH POLYESTER OR POLYPROPYLENE BACK CLOTH"."

PAGE 2, SLEEVE LINING AND BINDINGS: LINE 3, DELETE

"THE COLOR SHALL BE A GOOD MATCH TO THE BASIC

MATERIAL." AND SUBSTITUTE "THE COLOR SHALL

APPROXIMATE THE BASIC MATERIAL."

PAGE 2, LINER SLEEVES: LINE 3, DELETE "THE COLOR

SHALL BE A GOOD MATCH TO THE LINER MATERIAL."

AND SUBSTITUTE "THE COLOR SHALL APPROXIMATE THE

LINER MATERIAL."

PAGE 2, BUTTON: DELETE PARAGRAPH IN ITS ENTIRETY

AND SUBSTITUTE:

"BUTTONS. THE BUTTONS SHALL BE TYPE II, CLASS D,

STYLE 20/21. THE COLOR SHALL BE BLACK BT, CABLE

NO. 62001 IN ACCORDANCE WITH STANDARD SHADE FOR

BUTTONS. THE COAT SHALL HAVE 40 LIGNE FOR FRONT

FLY; 30 LIGNE FOR THE LAPEL, EPAULETS AND STORM

TAB; 24 LIGNE FOR SLEEVE TAPS, SLEEVE LINER,

THROAT TAB AND BACK VENT, AND STYLE 15, 18 LIGNE

FOR STAY BUTTONS. THE BUTTONS SHALL CONFORM TO

V-B-871. THE FRONT FLY BUTTONS SHALL BE SHANK

WRAPPED."

PAGE 2, THREAD: DELETE ENTIRELY AND SUBSTITUTE

THE FOLLOWING PARAGRAPHS:

"THREAD. THE THREAD FOR SEAMING AND STITCHING

SHALL BE COTTON WRAP POLYESTER CORE THREAD CON-

FORMING TO TYPE I, SIZE 50 FOR NEEDLE AND 50 OR

70 FOR BOBBIN OR LOOPER IN A-A-50199. SIZE 30

SHALL BE USED FOR BUTTON SEWING. THE COLOR SHALL

TREATED WITH AN APPROVED "QUARPEL TYPE" WATER

REPELLENT.

GIMP. THE GIMP FOR REINFORCING BUTTONHOLES SHALL

BE COTTON, BLACK AA CA66030 CONFORMING TO SIZE

NO. 8 TYPE I OR II OF A-A-50198. THE GIMP SHALL

SHOW "GOOD" COLORFASTNESS TO DRYCLEANING WHEN

TESTED AS SPECIFIED IN A-A-50198."

PAGE 3, LABELS: DELETE PARAGRAPH IN ITS ENTIRETY

AND SUBSTITUTE THE FOLLOWING PARAGRAPHS:

COAT LABELS. EACH COAT SHALL HAVE A PERSONNEL-

IDENTIFICATION LABEL, A SIZE LABEL AND AN

INSTRUCTION LABEL TYPE IV OF MIL-DTL-32075.

THE LABELS SHALL SHOW FASTNESS TO LAUNDERING

AND DRY CLEANING. ALL THE LABELS SHALL BE

STITCHED ON ALL FOUR SIDES AND THE STITCHING

SHALL NOT BE THROUGH THE PRINTING.

PERSONNEL-IDENTIFICATION LABEL FOR COAT.

THE PERSONNEL-IDENTIFICATION LABEL FOR THE

COAT SHALL CONFORM TO CLASS 1 AND 10. AS AN

ALTERNATE THE PERSONNEL IDENTIFICATION LABEL

AND INSTRUCTION LABEL MAY BE COMBINED IN ONE

LABEL. THE LABEL SHALL POSITIONED UNDER THE

SIZE LABEL. THE TOP EDGE OF THE PERSONNEL-

IDENTIFICATION LABEL MAY CAUGHT IN THE BOTTOM

ROW OF STITCHING OF THE SIZE LABEL.

SIZE LABEL FOR COAT. THE SIZE LABEL FOR THE

COAT SHALL CONFORM TO CLASS 2. SHORT, REGULAR

LONG AND EXTRA LONG MAY BE ABBREVIATED S, R, L

X-L RESPECTIVELY. THE SIZE LABEL SHALL BE

ATTACHED TO THE RIGHT FRONT FACING, STARTING

APPROXIMATELY ONE INCH BOTTOM FRONT FACING

TAB STAY BUTTON.

INSTRUCTION LABEL FOR COAT. THE INSTRUCTION

LABEL FOR THE COAT SHALL CONFORM TO CLASS 3 AND

SHALL CONTAIN THE INFORMATION BELOW.

THE LABEL SHALL POSITIONED UNDER THE PERSONNEL-

IDENTIFICATION LABEL.THE TOP EDGE OF INSTRUCTION

LABEL MAY BE CAUGHT IN THE BOTTOM ROW

STITCHING OF THE IDENTIFICATION LABEL.

MACHINE WASH SEPARATELY WITH WARM OR COLD WATER.

. RINSE THREE (3) TIME TO REMOVE ALL SOAP

. DO NOT SPIN OR WRING. HANG TO DRY,

. OR, COMPLETE THE WASH CYCLE AND TUMBLE DRY AT

. 140 DEGREES F.

. TOUCH UP WITH A COOL IRON.

. OR

. DRY CLEAN THOROUGHLY RINSING TO REMOVE ALL

. DETERGENTS.

PAGE 3 AFTER WASHING INSTRUCTIONS, INSERT THE

FOLLOWING PARAGRAPH:

"DSCP EXCLUSIVE LABEL: EACH COAT SHALL HAVE THE

DSCP EXCLUSIVE LABEL SEWN TO THE RIGHT INSIDE

FRONT FACING ABOVE THE SIZE/INSTRUCTION LABELS.

THE LABEL SHALL APPROXIMATELY 2 INCHES WIDE AND

BE SEWN ON ALL FOUR SIDES."

PAGE 3, PATTERNS: DELETE AND SUBSTITUTE,

"PATTERNS. THE GOVERNMENT WILL FURNISH

A COMPLETE SET OF PATTERNS. MINOR MODIFICATIONS

ARE PERMITTED TO ACCOMMODATE AUTOMATIC EQUIPMENT

AND A MANUFACTURERS PRODUCTION PROCESS. WHEN

PATTERN IS MODIFIED, THESE MODIFICATIONS SHALL

NOT ALTER THE FINAL DIMENSIONAL, SERVICEABILITY

ALLOWANCE OF 3/8 INCH FOR SAFETY STITCH AND

OR APPEARANCE REQUIREMENTS CITED IN THIS DOC-

UMENT. THE PATTERN GENERALLY PROVIDES A SEAM

ALLOWANCE OF 3/8 INCH FOR SAFETY STITCH AND

JOINING SEAMS.

PATTERN LIST

COMPUTER PIECE CUT SZS LNGT

NOMEN NOMEN

FRONT FRONT 2

BACK BACK 2

FRTFAC FRONT FACING 2

FRTSLV FRONT SLEEVE 2

BACKSLV BACK SLEEVE 2

FRTLING FRONT LINING 2

BACKLING BACK LINING 1

FRTSLVIN FRONT SLEEVE LINING 2

BKSLVLIN BACK SLEEVE LINING 2

FRTFACINT FRONT FACING INTERLINING 2

FRTLINER FRONT LINER 1

BKLINER BACK LINER 2

FRSLVLINR FRONT SLEEVE LINER 2

BKSLVLINR BACK SLEEVE LINER 2

EPAULET EPAULET 4

EPAULET EPAULET INTERLINING 2

SHLDREIN SHOULDER REINFORCEMENT 2

FLY FLY 2 ALL

FLYINTG FLY INTERLINING 1 ALL

FLYBHL FLY BUTTONHOLE MAKER TEMPLATE ALL

COLLAR COLLAR 2 ALL

CLRSTAND COLLARSTAND 2 ALL

COLINTG COLLAR INTERLINING 1 ALL

CLRSTDINT COLLARSTAND

. INTERLINING 2 ALL

FINCOLR FINISHED COLLAR TEMPLATE ALL

FRSLBTINT FRONT SLEEVE BOTTOM

. INTERLINING 2 ALL

BKSLBTINT BACK SLEEVE BOTTOM

. INTERLINING 2 ALL

PKTINNER POCKET INNER PLY 2 ALL

PKTOUTER POCKET OUTER PLY 2 ALL

PKTWELT POCKET WELT 2 ALL ALL

PKWLTINT POCKET WELT 2 ALL ALL

. INTERLINING

PKTFAC POCKET FACING 2 ALL ALL

FINPKWLT FINISHED POCKET TEMPLATE ALL ALL

. WELT

FACTAB FACING TAB 1 ALL AL

SLVTAB SLEEVE TAB 2 ALL ALL

FINFACTB FINISHED FACING

. TAB MARKER TEMPLATE ALL ALL

FINSLTAB FINISHED SLEEVE

. TAB MARKER TEMPLATE ALL ALL

FINFLYSTG FINISHED FLY

. STITCHING MARKER TEMPLATE ALL ALL

LAPELMKR LAPEL MARKER TEMPLATE ALL ALL

FINEPAUL FINISHED EPAULET TEMPLATE ALL ALL"

PAGE 3, AFTER "PATTERN LIST", ADD:

"TABLE I - SEAMS AND STITCHES 1/

LOCATION SEAM/STCH STCH

. TYPE TYPE

OUTER SHELL CENTER BACK AND

SIDE SEAMS SSW-2 301

OUTER SHELL TOP ARM SEAMS LSQ-2 301 OR

. 401

OUTER SHELL UNDER ARM SEAMS S SA-1 301 OR

. 401

LINER JOINING SEAMS SSA-2 515 OR

. 516 OR

. 519

1/ IN ACCORDANCE WITH FED-STD-751"

ADDITIONAL CHANGES TO A-A-50367

PAGE 4, SIZES AND MEASUREMENTS:

- LINE 2, DELETE "TABLES I AND II" & SUBSTITUTE

"TABLES II AND III".

LINE 5, DELETE "TABLE I" AND SUBSTITUTE

"TABLE II".

- LINE 23, DELETE "TABLE II" AND SUBSTITUTE

"TABLE III".

- IN TABLE FOR "COAT MEASUREMENTS", ADD 1 INCH

TO "CHEST" MEASUREMENTS, SIZES 28 THROUGH 52.

PAGE 4, TABLE I, COAT MEASUREMENTS, UNDER

LINE FOR SIZE "52" ADD NEW LINE FOR SIZE "54":

"54 63 41-1/4 43-1/4 45-1/2 47-3/4"

UNDER "SLEEVE LENGTH" COLUMN,FOR X-LONG

DELETE "20-1/4" AND SUBSTITUTE"20-1/2"

TABLE II, LINER MEASUREMENTS, UNDER

LINE FOR SIZE "52" ADD NEW LINE FOR SIZE "54":

"54 54 32 5/8 34 5/8 36 7/8 39"

UNDER "SLEEVE LENGTH" COLUMN FOR X-LONGS,

DELETE "19 1/4" AND SUBSTITUTE "19 1/2"

PAGE 5, DEFECTS, LINE 10, AFTER "DEFECTIVE"

INSERT "FRONT FLY BUTTONS NOT SHANK

WRAPPED".

PAGE 6, PACKAGING, DELETE LAST SENTENCE

IN ITS ENTIRETY AND SUBSTITUTE: "THE FOLDED COAT

SHALL BE BANDED WITH A COMMERCIALLY ACCEPTABLE

PAPER STRIP ACROSS THE MIDDLE WITH THE ENDS OF

THE STRIP SEALED WITH GUMMED PAPER TAPE.".

(Ref. W1940)

DELETE CURRENT "BARCODE LABEL/TAG"

REQUIREMENTS AND SUBSTITUTE THE FOLLOWING:

LABEL TAG. EACH ITEM SHALL BE INDIVIDUALLY

BAR-CODED WITH A PAPER TAG FOR PERSONAL

CLOTHING ITEMS. THE PAPER USED FOR THE TAGS

SHALL BE STANDARD BLEACHED SULFATE HAVING A

BASIS WEIGHT OF 100 POUNDS WITH A SMOOTH

FINISH TO ACCEPT THERMAL TRANSFER AND DIRECT

PRINTING. THE TAGS SHALL HAVE A HOLE AND

SHALL BE ATTACHED TO EACH ITEM BY A FASTENER,

CLEARLY LEGIBLE AND READABLE BY SCANNER.

THE BAR CODING ELEMENT SHALL BE A 13 DIGIT

NATIONAL STOCK NUMBER (NSN). THERE SHALL BE

A 12 DIGIT UNIVERSAL PRODUCT CODE (UPC)

ASSIGNED FOR ALL NSNS BY THE GOVERNMENT.

THE INITIAL "UPC" MUST APPEAR BENEATH THE

CODE. THE BAR CODES FOR NSN AND UPC SHALL BE

A MEDIUM TO HIGH DENSITY AND SHALL BE

LOCATED SO THAT THEY ARE COMPLETELY VISIBLE

ON THE ITEM WHEN IT IS FOLDED AND PACKAGED

AS SPECIFIED. THE LABEL'S LOCATION SHALL CAUSE

NO DAMAGE TO THE ITEM.

PACKAGING SECTION. ADD THE FOLLOWING:

NOTE: UNIVERSAL PRODUCT CODE INFORMATION

THE GOVERMENT ASSIGNED UNIVERSAL PRODUCT CODE

(UPC) MUST BE PLACED ON ALL SHIPPING CARTONS ON

WHICH THE NSN APPEARS.

THE FOLLOWING DEFECTS APPLY FOR BARCODE LABELS/

TAGS:

BAR CODE OMITTED OR NOT MINOR A

READABLE BY SCANNER

HUMAN-READABLE INTERPRETATION (HRI) MINOR A

OMITTED OR ILLEGIBLE

NOT VISIBLE ON FOLDED, PACKAGED ITEM MINOR A

CAUSES DAMAGE TO THE ITEM MAJOR

APPLICABLE DOCUMENTS: THE FOLLOWING LIST OF

DOCUMENTS IS APPLICABLE TO THIS PROCUREMENT:

AQLS FOR COMMERCIAL ITEM DESCRIPTION (CIDS)

END ITEM DIMENSIONAL 2.5

VISUAL 4.0

PALLETIZATION 6.5

ACCEPTABILITY OF LOTS WILL BE DETERMINED BY THE

USE OF "SAMPLING PROCEDURES AND TABLE FOR

INSPECTION BY ATTRIBUTES". ANSI/ASQC Z1.4

GENERAL INSPECTION LEVEL II

(Ref. T7520)

ADDITIONAL INFORMATION FOR A-A-50531:

STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER

AND COTTON (WATER REPELLENT), ARMY BLACK 385

CONFORMING TO A-A-50531, IS AVAILABLE ON ROLL

NO. 3668, AND APPLICABLE FOR SHADE, FINISH AND

COLORFASTNESS.

STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER AND

COTTON (WATER REPELLENT), MARINE CORPS PEWTER

2246 CONFORMING TO A-A-50531, IS AVAILABLE ON

ROLL NO. 1208-06, AND APPLICABLE FOR SHADE, FINISH

AND COLORFASTNESS.

STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER

AND COTTON (WATER REPELLENT), COAST GUARD BLUE

3376 CONFORMING TO A-A-50531, IS AVAILABLE ON

ROLL NO. 02318, AND APPLICABLE FOR SHADE,

FINISH, AND COLORFASTNESS.

INTERIM SPECIFICATION CHANGES

TO A-A-50531:

PAGE 1, PARA. 1.1, GENERAL, AT THE END OF THE

PARAGRAPH, ADD THE FOLLOWING SENTENCE:

"AN ALTERNATE CLOTH SHALL BE A 1 PLY, 65 +/- 3

PERCENT POLYESTER AND 35 +/- 3 PERCENT

COTTON POPLIN CLOTH.

PARAGRAPH 1.2, PHYSICAL REQUIREMENTS, SECOND

LINE, AFTER "I", DELETE THE PERIOD AND ADD "AND

TABLE II."

TABLE I. CHANGE TITLE OF TABLE FROM "PHYSICAL

REQUIREMENTS" TO "BASIC CLOTH PHYSICAL

REQUIREMENTS" (2 PLY).

PAGE 2, TABLE I, BASIC CLOTH PHYSICAL REQUIRE-

MENTS (2 PLY), UNDER TEST METHODS, DELETE "5550"

AND SUBSTITUTE "5556" FOR DIMENSIONAL STABILITY

TEST.

PAGE 3, BEFORE TABLE I FOOTNOTES, ADD THE

FOLLOWING NEW TABLE:

TABLE II. ALTERNATE CLOTH PHYSICAL REQUIREMENTS

(1 PLY)

CHARACTERISTICS REQUIREMENTS TEST METHOD

FIBER CONTENT 65% +/- 3% POLYESTER 2100 4/

. 35% +/- 3% COTTON 2100 4/

YARN PLY

. WARP SINGLES OR 2 PLY VISUAL 2/

. FILLING SINGLES VISUAL 2/

WEIGHT, OZ./SQ.

YD. 5.3-6.8 ASTM D 3776 3/

YARNS PER INCH (MIN.)

. WARP 107 ASTM D 3775 3/

. FILLING 68 ASTM D 3775 3/

WEAVE PLAIN VISUAL 2/

AIR PERMEABILITY

(MAX.) 10 ASTM D 737.75 3/

BREAKING STRENGTH, LBS. (MIN.)

. WARP 185 ASTM D 1682 3/

. FILLING 70 ASTM D 1682 3/

TEARING STRENGTH, LBS. (MIN.)

. WARP 5.0 ASTM D 5034 3/

. FILLING 2.0 ASTM D 5034 3/

DIMENSIONAL STABILITY, PERCENT (MAX.)

. WARP 2.0 5556 4/

. FILLING(1 PLY) 3.0 5556 4/

COLORFASTNESS TO:

LAUNDERING

(3 CYCLES) GOOD 5610 4/ 5/

PERSPIRATION GOOD 5680

CROCKING

. WET 2.5 5651 AND

. DRY 2.5 AATCC 8 4/ 8/

LIGHT

(40 HOURS) GOOD 5660 4/

PH 5.0-8.0 2811 4/

SPRAY RATING:

. INITIAL 100,100,90 5526 4/

. AFTER 3

LAUNDERINGS 70,70,70 5526 4/

. 1 DRY-

CLEANING 70,70,70 5508 AND 5526 4/

DYNAMIC ABSORPTION, PERCENT (MAX.)

. INITIAL 18 5500 4/

. AFTER 3

. LAUNDERINGS 18 5556 AND 5500 4/ 7/

HYDROSTATIC PRESSURE

. CM. (MIN.)

. INITIAL 30 5514 4/

. AFTER 3

LAUNDERINGS

(COTTON METHOD) 25 5556 AND 5514 4/ 7/

. AFTER 1

DRY CLEANING 25 5508 ABD 5514 4/

RESISTANCE TO ORGANIC

LIQUID (MIN.)

. INITIAL NO WETTING AATCC 118 8/

. (N-TETRADECANE)

. AFTER 3

LAUNDERINGS

(COTTON METHOD) NO WETTING 5556 AND 7/

. AATCC 118 8/

WATER REPELLENT 9/

THE FOLLOWING FOOTNOTES SHALL APPLY TO BOTH

TABLE I AND TABLE II."

PAGE 4, PARAGRAPH 1.3, PUT UP., LINE 2, DELETE

"50 AND SUBSTITUTE "40".

PAGE 8, UNDER "REVIEW ACTIVITY", ADD THE

FOLLOWING: "NAVY - NU".

(Ref. T0495)

LIST OF APPROVED WATER REPELLENT TREATMENTS FOR MILITARY FABRICS 1/

THE FOLLOWING FLUOROCHEMICALS ARE APPROVED "DURABLE" TYPE WATER REPELLENT TREATMENTS FOR USE ON MILITARY FABRICS. THEY MAY BE USED ALONE OR COMBINED WITH AN APPROVED EXTENDER COMPONENT TO PRODUCE A "QUARPEL" TYPE OF WATER REPELLENT TREATMENT REPELLENT TREATMENTS:

TRADE NAME SUPPLIER

AURAPEL FC-340 AURALUX DIV OF SYBRON

CHEMICAL CO.

P.O. BOX 113

YANTIC, CT 06389

TEL: 860-886-2626

BARPEL 1700 APOLLO CHEMICAL CORP.

PO BOX 2176

BURLINGTON, NC 27215

TEL: 910-226-1161

CHEMSHIELD 939 CHEM-TEX INC.

WR 930 P.O. BOX 1105

1891 N. COLUMBIA ST.

BLDG 106, MILLEDGEVILLE, GA 31061

TEL: 336-578-5476

FABRIC GUARD ML TANNER CHEMICAL CO., INC.

PO BOX 1967, FURMAN HALL

COURT, GREENVILLE, NC 29602

TEL: NO LISTING IN NC ON 800#

ZONYL B CIBA-GEIGY CORP.

ZONYL D P.O. BOX 11422

ZONYL RN 2/ HIGHPOINT, NC 27409

ZONY 6700 TEL: 888-396-2488

ZONYL 6700 GF

ZONYL 7040

ZONYL 8300

ZONYL 8070

ZONYL DWR

ZONYL MIL

FC-232 3M CORPORATION,

FC-251 PROTECTIVE PRODUCTS DIV.

FC-461 ST. PAUL, MN. 02895

FC-831 TEL: 612-737-0098

REPEARL F-14N MITSUBISHI INTERNATIONAL

REPEARL F-35 520 MADISON AVE.

REPEARL F-31 NEW YORK, NY 10022

TEL: 212-605-2440

800-851-5765

NK GUARD FG-280 NICCA USA, INC.

P.O. BOX 1600

5000 NELSON ROAD

FOUNTAIN INN, SC 29644

TEL: 864-862-1426

SEQUAPEL CQR SEQUA CHEMICAL CORP.

SEQUAPEL NRL ONE SEQUA DRIVE

SEQUAPEL WOR CHESTER, SC 29807-0070

SEQUAPEL WOR-46 TEL: 803-385-5181

TEX-TEL NI-40 AUTO CHEMICAL CO.

THREE PARKWAY

PHILADELPHIA, PA 19102

TEL: 215-419-7000

UNIGUARD-5061 UNICHEM INC.

P.O. BOX 612

916 W. MAIN ST.

HAW RIVER, NC 27258

TEL: 336-578-5476

FLUOROGARD 1700 PUTNAM INDUSTRIES, INC

197 RIDGEWOOD AVE.

GLEN RIDGE, NJ 07028

TEL: NOT LISTED

FLO CHEM EXTRA 17-4 EMCO SERVICES INC.

P.O. BOX 2191

TAUNTON, MA 02780

TEL: 508-823-8852

1/ A SEPARATE LIST OF APPROVED WATER REPELLENT TREATMENTS EXISTS FOR FABRICS CONFORMING TO CLOTH, CAMOUFLAGE PATTERN; WOODLAND, COTTON AND NYLON, CLASS 2, MIL-C-44031 AND CLOTH, TWILL, CAMOUFLAGE PATTERN, COTTON AND NYLON FOR DESERT UNIFORM, CLASS 1A, MIL-C-44034.

2/ FOR POLYESTER, NYLON AND BLENDS OF MANMADE FIBERS ONLY.

(ref. T0153 - May 18, 2006)

ADDITIONAL INFORMATION FOR A-A-55634A, 23 MARCH 2004:

SPECIAL NOTE!! ALL SLIDE FASTENERS USED ARE TO BE MEASURED FROM "STOP TO STOP". RECOMMEND THAT THIS MEASUREMENT BE TAKEN RANDOMLY BEFORE SLIDE FASTENERS ARE SEWN TO THE ITEMS, COVERALL, OR ANY ITEM REFERRED TO IN THE SOLICITATION. "THE QAR WILL REJECT ANY SLIDE THAT IS NOT LAYING FLAT AFTER IT IS SEWN INTO/ONTO AN ITEM." SPECIAL INFO ON ITEMS THAT UTILIZE SLIDE FASTENERS IS GIVEN BY "ALL USING MILITARY PERSONNEL".

MIL-DTL 32075: LABEL FOR CLOTHING, EQUIPAGE, AND TENTAGE, GENERAL USE REPLACES DDD-L-20 (Ref. T0451 - June 19, 2007)

INTERIM SPECIFICATION CHANGES TO MIL-DTL-32075:

Page 6, TABLE I, "Physical requirements of the Type VI finished label" Under "Tearing strength" delete: "(lb.) minimum" and substitute: "(gms) minimum"

ADDITIONAL INFORMATION FOR MIL-P-15011: NO ADDL. INFORMATION FOLLOWS.

(ref. T1368 - 6/15/06)

ADDITIONAL INFORMATION FOR MIL-B-17757:

MIL-B-17757 IS CANCELLED WITHOUT REPLACEMENT.

ASTM-D-5118 IS AUTHORIZED FOR USE IN LIEU OF MIL-B-17757

(ref. T0857 - 6/15/06)

ADDITIONAL INFORMATION FOR MIL-I-45208:

NOTE: MIL-I-45208 HAS BEEN CANCELLED AND REPLACED BY THE FOLLOWING: INTERNATIONAL STANDARDS ISO 9001:2000 OR AMERICAN SOCIETY FOR QUALITY ASQ 2003 VERSION.

HIGHER LEVEL INSPECTION SYSTEM:

THE INSPECTION SYSTEM(S) MUST BE SUBMITTED WITH YOUR BID PROPOSAL FOR EVALUATION AND APPROVAL BY DSCP'S CONTRACTING OFFICER.

INSPECTION SYSTEM(S) COMPLIANT/BUT ARE NOT LIMITED TO THE INTERNATIONAL STANDARDS ISO 9002 OR ASQ 2003 MAY BE UTILIZED IF TAILORED TO THE SPECIFIC QUALITY ASSURANCE REQUIREMENTS IN THIS SOLICITATION.

ADDITIONAL INFORMATION FOR FED-STD-191:

FED-STD-191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW DESIGN. WHEN NOT USING FED-STD-191, SEE INTERIM CHANGES TO END ITEM SPECIFICATION FOR REPLACEMENT ASTM.

INTERIM CHANGES TO FED-STD-191A:

TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT ONE INCH OF SPECIMEN LIES WITHIN THE CLAMP AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE".

TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA 4.1.2,LINE 4: DELETE "B-97" AND SUBSTITUTE "B-91".

THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND 1550. PARA 5.1 OF THESE TEST METHODS REQUIRE THE USE OF 1,1,1- TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1-TRICHLORETHANE IS AN OZONE DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE PROHIBITED. THE USE OF EITHER ALCOHOL OR ETHER IS REQUIRED WHEN THESE METHODS ARE IN BASIC OR ANY REFERENCED DOCUMENT.

METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING METHOD. PAGE 2, PARA. 5.3 DELETE FIRST SENTENCE AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH 1 END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT 1" OF THE SPECIMEN LIES WITHIN THE CLAMP AND 1" OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (INNER FACE OF THE VISE) AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE."

METHOD 5556.1, MOBILE LAUNDRY EVALUATION FOR TEXTILE MATERIALS, PAGE 5, PARA. 5.2.2, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACK TEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 45-60 MINUTES OR UNTILSAMPLES ARE DRY IN A ROTATING TUMBLE DRYER."

PAGE 5, PARA. 5.2.3, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THEFOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACKTEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 35-40 MINUTES OR UNTIL SAMPLES ARE DRY."

METHOD 5931, ELECTROSTATIC DECAY OF FABRICS; DETERMINATION OF PAGE 1, PARA. 3: AFTER NUMBER OF DETERMINATIONS ADD "PER SAMPLEUNIT". PAGE 1, PARA. 4: DELETE "APPARATUS" AND SUBSTITUTE "APPARATUS". PAGE 1, PARA. 5.1, LINE 3: AFTER "AT" DELETE"APPROXIMATELY".

PAGE 2, PARA. 5.2, LINES 2, AND 5: AFTER "OF" ADD "+-". LINE 6: AFTER "TO" ADD "+-".

PAGE 2, PARA. 5.3: DELETE IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:"5.3 MOUNT A SPECIMEN TIGHTLY ACROSS THE ELECTRODES, CENTERING IT OVER THE SENSOR OPENING. THE SURFACE OF THE TEST SPECIMEN (BACK OR FRONT) SHALL FACE THE SENSOR. RECORD (OPTIONAL) THE RESIDUAL CHARGE LEVEL ON THE SAMPLE AS SEEN BY THE SENSOR, INCLUDING POLARITY.

NOTE THAT TEST SAMPLES WITH THE RESIDUAL CHARGE LEVELS OF LESS +500 VOLTS YIELD THE BEST RESULTS. APPLY +5000 VOLTS TO THEELECTRODES FOR A PERIOD OF 20 SECS. AT THE END OF THE 20 SECOND PERIOD, THE HIGH VOLTAGE (5000 VOLTS) SHALL BE TURNED OFF ANDTHE SPECIMENS IMMEDIATELY GROUNDED. THE VOLTAGE BEHAVIOR OF THE SPECIMEN WITH RESPECT TO TIME SHALL BE PLOTTED ON THE RECORDER. NOTE: IN SOME CASES, THE TEST EQUIPMENT WILL DISPLAY VOLTAGE AND DECAY TIME INFORMATION AND A CHART RECORDER IS NOT NECESSARY."

PAGE 2, PARA. 5.4, LINE 3: DELETE SENTENCE BEGINNING WITH "IF THE SPECIMEN DID" IN ITS ENTIRETY.

PAGE 2, PARA. 5.5: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "RECORD THE MAXIMUM VOLTAGE LEVEL(INCLUDING POLARITY) AND DECAY TIME TO 10% OF THE MAXIMUM VOLTAGE LEVEL ACHIEVED."

PAGE 2, PARA. 5.6, LINE 1: ADD THE FOLLOWING PRIOR TO 1ST SENTENCE: "REVERSE VOLTAGE POLARITY REPEAT MEASUREMENT, ANDRECORD RESULTS."

PAGE 3, PARA. 6.6: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE AVERAGE TIME TO DECAY TO 10%OF THE MAX VOLTAGE SHALL BE INCLUDED FOR EACH OF THE WARP & FILLING DIRECTIONS, AS WELL AS THE OVERALL AVERAGE, FOR EACHFABRIC TESTED. THESE WILL BE OBTAINED BY AVERAGING THE TEST RESULTS (ABSOLUTE VALUE OF) TOGETHER FOR BOTH VOLTAGEPOLARITIES. UNLESS OTHERWISE STATED IN THE REQUIREMENTS DOCUMENT, THE FABRIC SHALL BE CONSIDERED ACCEPTABLE IF THEAVERAGE MAXIMUM VOLTAGE IN BOTH THE WARP AND FILLING DIRECTIONS IS LESS THAN 4000 VOLTS, AND THE AVERAGE DECAY TIME (TO 10% MAXVOLTAGE) IS GREATER THAN 0.5 SECONDS IN BOTH THE WARP AND FILLING DIRECTIONS. IT SHALL BE INDICATED WHETHER THE FABRIC ISACCEPTABLE OR NON-ACCEPTABLE."

PAGE 3, PARA. 7.1, SECOND COLUMN, LINE 2: DELETE 406C AND SUBSTITUTE WITH "406D".

AFTER PARA. 7.1, ADD THE FOLLOWING: "7.2 NOTE: IF THE MODEL 406D STATIC DECAY METER, OR EQUIVALENT, IS USED, A CHART RECORDER ISNOT MANDATORY FOR THE TEST."

ADDITIONAL INFORMATION: FED-STD-751 HAS BEEN CANCELLED AND REPLACED BY ASTM-D-6193, 4/98 STANDARD PRACTICES FOR STITCHES AND SEAMS.

THIS STANDARD SHOULD BE USED IN PREFERENCE TO FED-STD-751.

(ref. T0216 - May 18, 2006)

MIL-STD-129P, WITH CHANGE 4 - DEPARTMENT OF DEFENSE STANDARD PRACTICE MILITARY MARKING FOR SHIPMENT AND STORAGE - DATED

19 SEPTEMBER 2007

INTERIM CHANGES:

OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS

IN THE DEFENSE SUPPLY CENTER (DSCP) CLOTHING AND TEXTILE (C&T) DIRECTORATE:

THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DSCP C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT.

IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE LOADED FOR EACH SHIP- MENT. THE WORDS "PACKING LIST HERE" SHALL BE STENCILED, NOT

HAND LETTERED, ON THE CONTAINER.

ADDITIONAL INFORMATION:

MIL-STD-147 IS HEREBY REINSTATED AS FOLLOWS:

MIL-STD-147E DEPARTMENT OF DEFENSE

16 MAY 2008 STANDARD PRACTICE

PALLETIZED UNIT LOADS

STANDARDS (COMMERCIAL)

ASME-MH1 American Society of Mechanical Engineers (ASME) Pallets, Slip Sheets, and Other Bases For Unit Loads, for construction of pallets.

Other files for this federal contract opportunity

Other files attached to Univewrsal All Weather Coats Core Group, newest first.
File Type Posted
SQUARE INCH ALLOWANCE TABLE PGC 02851(AUG 4 2009).rtf RTF text file
SQUARE INCH ALLOWANCE TABLE PGC02110(AUG 4 2009).RTF RTF text file
PGC 02110 tech data(AUG 4 2009).docx DOCX document
SQUARE INCH ALLOWANCE TABLE PGC 01940(AUG 4 2009).RTF RTF text file
PGC 02850 tech data —
SQUARE INCH ALLOWANCE TABLE PGC 01908(AUG 4 2009).RTF RTF text file
PGC 02851 tech data —
SQUARE INCH ALLOWANCE TABLE PGC 02850(AUG 4 2009).rtf RTF text file
PGC 01908 tech data(AUG 4 2009).docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .