SPECIFICATIONS.pdf
PDF 435 KB Posted
- Attached to
- RENEGADE ES300I WELDER
- Solicitation number
- SPMYM2-23-Q-1058
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOLICITATION SPMYM2-23-Q-1058.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Light weight Industrial Stick/TIG welding machine
Document # 3073-3340
Must meet the following specifications:
Must be able to weld on material type: Mild Steel, Stainless Steel
Must be able to weld maximum material thickness3/8 in (Aluminum), 3/8 in
(Mild Steel)
Must be able to weld minimum material thickness0.004 in (Mild Steel),
0.012 in
(Aluminum)
Input Frequency50/60 Hz
Max. Input Current200A at 230 - 460 VAC 1ph, 300A at 230 - 460 VAC 3ph
Must run on single-phase at 5-200 Amps and three-phase at 5-300 Amps
Polarity DC
Stick Welding Maximum Output Current 300 A
Stick Welding Minimum Output Current 5 A
Stick Welding Output @ Duty Cycle 200 A @ 28 V, 100%, 250 A @ 30 V, 60%, 300
A @ 32 V, 40%
TIG Welding Maximum Output Current 300 A
TIG Welding Minimum Output Current 5 A
TIG Welding Output @ Duty Cycle 200 A @ 18 V, 100%, 250 A @ 20 V, 60%, A @ 22 V, 40%
Welding Processes Stick Welding (SMAW), TIG Welding (GTAW)
Must have Amperage Range 5 A to 300 A
Must have Digital Readout Display, Integrated Latch System, Intuitive
Interface, Rugged Case, Small, Three Handle Design
Must include power supply, 10-ft. input cable, and two OKC 50 connectors
Input Voltage208V AC, 460V AC
Must have the following dimensions: Overall Depth 18.5 inches, Overall
Height 12.61 inches, Overall Width 7.91 inches
Plug Type: Bare Leads
Must meet Nationally Recognized Testing Laboratory standards (CSA)
Must weigh 33 pounds or less (for mobility standards)
Must have welding Mode: CC
Rated Output - STICK
40% Duty Cycle 3ph at 300 A / 30 V
60% Duty Cycle 3ph at 250 A / 30 V
100% Duty Cycle 1ph/3ph at 200 A / 28 V
Rated Output –
40% Duty Cycle at 300 A / 20 V
60% Duty Cycle at 250 A / 20 V
100% Duty Cycle 1ph/3ph at 200 A / 18 V
Low open circuit voltage option must be enabled (VRD)