*** LTC PID Packaging Consolidated Text *** PLEASE SEE GLOSSARY AT THE END OF THE DOCUMENT FOR FULL TEXT OF THE ITEM DESCRIPTION

AND PACKAGING REFERENCE NUMBERS CALLED OUT FOR EACH NSN.

NSN:012553347

PARTS KIT, HULL SEMI-ANNUAL

REFERENCE NUMBER:ZD071

REFERENCE NUMBER:CS001

REFERENCE NUMBER:ZD059

REFERENCE NUMBER:CS147

REFERENCE NUMBER:ZD054

Quality Assurance Provisions(QAPs):

Provided I/A/W the following drawings<(>,<)> 12273559,12284708,12286856,12387379 and 12287953.

EXCEPTION TO DRAWING 12286856: SOURCE CONTROL ITEM. ONLY APPROVED SOURCE

IS SPS TECHNOLOGIES P/N 59FAF-813 CAGE

56878.

EXCEPTION TO DRAWING 12345800 NOTE 2: MIL-R-2765 BE USED IN LIEU OF

MIL-R-3065.

PROVIDE 1 EACH OF THE FOLLOWING PART NUMBER 12345800-2, 12345800-3, AND

12345800-4.

EXCEPTION TO DRAWING 12961043: GLOVES ALLEGIANCE HEALTHCARE CORP. CAGE

07TA6 PART NUMBER 2D7088 OR MAXIM MEDICAL INC. CAGE 06US7 PART NUMBER

480215 MAYBE USED IN LIEU OF CAGE 89875 PART NUMBER E-011.

EXCEPTION TO DRAWING 11610298: CAGE 87405 PART NUMBER CF-308-2PL IS

APPROVED BY ESA.

EXCEPTION TO DRAWING 12285860 PER NOR H08T2022 AND NOR L14T1006

DESICCANT PART NUMBER 02-00919AG27 OR 02-00919AG29 MAY BE USED IN LIEU

OF 02-00919AG07.

EXCEPTION TO DRAWING 5705438: NSN FOR LITHIUM BATTERY ON PAGE 4 SHOULD

READ 6135-01-481-7127 IN LIEU OF 6135-01-441-5746.

USE MIL-STD-129P W/CHG 2

REFERENCE NUMBER:CQ009

REFERENCE NUMBER:CQSL6

REFERENCE NUMBER:CS001

REFERENCE NUMBER:CS187

REFERENCE NUMBER:CS086

REFERENCE NUMBER:CA070

CRITICAL APPLICATION ITEM

IAW BASIC DRAWING NR 19207 5705438

REVISION NR AG DTD 08/15/2011

PART PIECE NUMBER: 5705438

IAW REFERENCE QAP 19207 12273559

REVISION NR DTD 03/22/1993

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12287953

REVISION NR F DTD 06/30/1993

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12288306

REVISION NR R DTD 04/12/1996

PART PIECE NUMBER: REFERENCE

IAW REFERENCE DRAWING NR 19207 12387272

REVISION NR A DTD 07/12/2007

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11602062

REVISION NR F DTD 08/30/1988

PART PIECE NUMBER: REFERENCE

IAW REFERENCE QAP 19207 12284708

REVISION NR D DTD 11/16/2011

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19206 7309998

REVISION NR E DTD 03/21/1984

PART PIECE NUMBER: REFERENCE

IAW REFERENCE QAP 19207 12286856

REVISION NR B DTD 02/27/1995

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12336831

REVISION NR H DTD 11/12/1996

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12336814

REVISION NR K DTD 07/03/2002

PART PIECE NUMBER: 12336814-8, -10 & -11

IAW REFERENCE DRAWING NR 19207 12273563

REVISION NR U DTD 12/10/2008

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12345034

REVISION NR A DTD 09/21/1987

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19206 12312058

REVISION NR A DTD 04/27/1987

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 5911304

REVISION NR D DTD 06/28/2005

PART PIECE NUMBER: 5911304-134

IAW REFERENCE DRAWING NR 19207 5705135

REVISION NR C DTD 05/11/1987

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11610298

REVISION NR F DTD 03/29/1993

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12282157

REVISION NR H DTD 12/17/1991

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12273464

REVISION NR C DTD 01/11/1991

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12272827

REVISION NR L DTD 06/06/1995

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12472719

REVISION NR DTD 09/28/2000

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 9377334

REVISION NR A DTD 09/17/1991

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12286856

REVISION NR J DTD 05/27/1997

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12284544

REVISION NR A DTD 08/07/1992

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19206 7309998

REVISION NR E DTD 03/21/1984

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12288067

REVISION NR C DTD 09/12/1989

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12387269

REVISION NR C DTD 12/28/2007

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12387299

REVISION NR DTD 02/26/1992

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12387349

REVISION NR B DTD 06/29/2007

PART PIECE NUMBER: 12387349-35

IAW REFERENCE DRAWING NR 19207 12472719

REVISION NR DTD 09/28/2000

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12987693

REVISION NR DTD 02/20/2001

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12273559

REVISION NR I DTD 10/01/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11602061

REVISION NR H DTD 01/01/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12324584

REVISION NR A DTD 11/11/1990

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11641857

REVISION NR E DTD 01/01/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12387152

REVISION NR D DTD 10/05/2010

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12272827

REVISION NR L DTD 09/19/2006

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19206 12528494

REVISION NR A DTD 06/05/2009

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12283641

REVISION NR C DTD 09/25/2006

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12288303

REVISION NR G DTD 07/16/1996

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19206 12529740

REVISION NR C DTD 11/15/1983

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12272684

REVISION NR G DTD 08/27/1998

PART PIECE NUMBER:

IAW REFERENCE QAP 19207 12387379

REVISION NR B DTD 05/28/2003

PART PIECE NUMBER:

IAW REFERENCE QAP 19207 12287953

REVISION NR DTD 04/16/1993

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705143

REVISION NR G DTD 11/17/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705155

REVISION NR B DTD 03/16/1988

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11602063

REVISION NR L DTD 04/11/1994

PART PIECE NUMBER: REFERENCE

IAW REFERENCE DRAWING NR 19200 9377106

REVISION NR C DTD 02/23/2006

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12284708

REVISION NR F DTD 05/23/2003

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12301979

REVISION NR B DTD 03/13/1990

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12344039

REVISION NR E DTD 06/24/2005

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12345800

REVISION NR B DTD 04/22/2003

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12387379

REVISION NR C DTD 09/03/2002

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 1NUW7 12528494

REVISION NR DTD 10/25/2001

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12961043

REVISION NR B DTD 08/06/2002

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12387299

REVISION NR DTD 02/26/1992

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705438

REVISION NR R DTD 11/10/2005

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705134

REVISION NR B DTD 05/11/1987

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705134

REVISION NR B DTD 05/11/1987

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705143

REVISION NR G DTD 11/17/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705155

REVISION NR B DTD 03/16/1988

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705207

REVISION NR C DTD 05/17/2002

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11610232

REVISION NR A DTD 01/01/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 11641744

REVISION NR B DTD 01/01/1999

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12282157

REVISION NR J DTD 12/07/2007

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 12285860

REVISION NR E DTD 08/07/2008

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19200 12285860

REVISION NR G DTD 10/18/2008

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705135

REVISION NR E DTD 05/11/1987

PART PIECE NUMBER:

IAW REFERENCE DRAWING NR 19207 5705438

REVISION NR DTD 02/10/2014

PART PIECE NUMBER:

PREP FOR DELIVERY

LINE ITEM 00001 TYPE OF COVERAGE: DLA DIRECT, CONUS

PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999

QUP:001 PRES MTHD:ZZ CLNG/DRY:Z PRESV MAT:ZZ

WRAP MAT:ZZ CUSH/DUNN MAT:ZZ CUSH/DUNN THKNESS:Z

UNIT CONT:ZZ OPI:A

INTRMDTE CONT:ZZ INTRMDTE CONT QTY:ZZZ

PACK CODE:U

MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.

SPECIAL MARKING CODE:ZZ -ZZ Special Requirements

PACKAGING SHALL BE IN ACCORDANCE WITH SPECIAL

PACKAGING INSTRUCTION 12553347.

GLOSSARY

PACKAGING TEXT

THE FOLLOWING PARAGRAPH APPLIES TO ALL PACKAGING CALLED OUT IN THIS DOCUMENT:

ITEM DESCRIPTION TEXT

REFERENCE NUMBER ZD071

Configuration Change Management - Engineering Change Proposal, Requests for Variance (Deviation or Waiver) February 2015

1. Requirements A. The Configuration Change Management section of SAE EIA-649-1 Configuration Management Requirement for Defense Contracts, Paragraph 3.3, shall be used for Configuration Control of material purchased under this contract.

B. Furnished item(s) shall conform to the approved configuration requirements/revision specified, unless a Pre-Production Request for Variance (deviation) or a Post-Production Request for Variance (waiver), is processed and approved as provided by Paragraph 3. in this Standard Text Object (STO). Hereafter, the term #Request for Variance (RFV)# will also include Requests for Deviations and Waivers.

2. The definitions from EIA-649-1 apply to items being procured under this solicitation/contract, with the following clarification of Deviation & Waiver:

A. Pre-Production RFV (previously known as deviation) requests permission to produce a product that does not conform to contract requirements/documentation for a limited amount of time and for specified effectivity. (A deviation differs from an engineering change in that an approved engineering change requires corresponding revision of the item's current approved configuration documentation, whereas a deviation does not.).

B. Post-Production RFV (previously known as waiver) requests approval of product found during manufacture, or after having been submitted for Government inspection or acceptance, that departs from specified requirements, but nevertheless is considered suitable for use "as is" or after repair by an approved method.

3. Contractor responsibilities.

A. An Engineering Change Proposal (ECP) is used to make permanent changes in the Government technical data package (TDP). Pending approval of an ECP, contractual relief should be requested in writing by the Contractor using a RFV.

B. Refer to FAR Part 48 Value Engineering for cost saving improvements to the Technical Data Package (TDP).

C. All ECPs submitted by the Contractor will be deemed routine.

If the Contractor considers an ECP as an emergency or urgent; they shall include in their ECP submittal an explanation and all applicable supporting documentation. All ECPs will be reviewed for a determination on criticality, and, if concurred to be an emergency, the appropriate processing time-frame negotiated with the ESAs will be followed and the Contractor will be notified of anticipated response time.

D. For ECPs, Specification Change Notices (SCNs) or RFV, the Contractor must submit the applicable documentation listed in sub-paragraphs D.(1) through D.(4)to the Administrative Contracting Officer(ACO), with an information copy to the Procuring Contracting Officer (PCO). Failure to submit a complete legible package may result in return of the ECP/RFV without processing.

(1) Documentation listed in Paragraph 3.3.1 (for ECPs), 3.3.2 (RFV), 3.3.3 (for SCNs) or 3.3.4 (for Notices of Revision (NORs)) of the latest revision of EIA-649-1.

(2) DD Form 1692 (current revision) for ECP.

(3) DD Form 1694 (current revision) for RFV.

(4) DD Form 1695 (current revision) for NOR.

4. DLA#s responsibilities:

A. Upon receipt of the ECP or RFV, the PCO will ensure that the applicable product specialist receives the copy from DCMA.

B. Within five (5) working days from the date of receipt of the Contractor's ECP or RFV from DCMA, the PS must submit the requests and any supporting documentation via a 339 to the appropriate Engineering Support Activity (ESA), when applicable.

C. Routine ECPs will be processed within 90 days from receipt by the ESA. RFVs will be evaluated and processed within 30 days from receipt by the ESA or as negotiated with the ESA.

(1) The contractor will be notified in writing of approval by the return of an approved copy of the ECP or RFV. Approval will be reflected by signature of the contracting activity or a review activity specifically identified in the contract.

(2) The contractor will be notified in writing of disapproval including reason(s) for disapproval.

5. For an approved RFV or an approved ECP, when the request affects the Contract, a modification will be issued to the contract incorporating the applicable requirement changes. Only a Contracting Officer is authorized to issue a modification incorporating the approved RFV and/or

ECP.

6. Questions regarding the status of previously submitted ECP or RFV should be directed to the PCO.

7. The submission of an ECP or RFV by the Contractor does not affect the required delivery date of the contract. If a delivery date change is needed, it must be negotiated with the Contracting Officer and documented via modification to the contract.

8. The period of time for evaluation and approval/disapproval of an ECP and/or a RFV, as specified in Paragraph 4. C., shall not constitute excusable delay in the performance of this Contract by the Contractor or in any way relieve the contractor from compliance with the contract delivery schedule. The submission of an ECP and/or RFV by the Contractor shall not preclude the Government from exercising its rights under any clause of the Contract. (End)

REFERENCE NUMBER CS001

THIS ITEM HAS TECHNICAL DATA SOME OR ALL OF WHICH IS SUBJECT TO

EXPORT-CONTROL REGULATIONS. DISTRIBUTION OF THE TECHNICAL DATA

AND ELIGIBILITY FOR AWARD ARE LIMITED TO THOSE SUPPLIERS QUALIFIED

THROUGH JCP CERTIFICATION, OR TO THOSE LICENSED BY EITHER THE

DEPARTMENTS OF STATE OR COMMERCE; OR TO FOREIGN SUPPLIERS PURSUANT TO

INTERNATIONAL AGREEMENTS.

TO APPLY FOR JCP CERTIFICATION, COMPLETE DD FORM 2345, MILITARY

CRITICAL TECHNICAL DATA AGREEMENT<(>,<)> FORM IS AVAILABLE AT THE WORLD

WIDE WEB ADDRESS HTTP://WWW.DLIS.DLA.MIL/JCP OR BY WRITING TO:

DLA LOGISTICS INFORMATION SERVICE

FEDERAL CENTER

74 WASHINGTON AVE., NORTH

BATTLE CREEK, MI 49037-3084

TO MANUFACTURE THIS ITEM, NON-JCP CERTIFIED SUPPLIERS MUST SUBMIT A

CURRENT MANUFACTURING LICENSE AGREEMENT, TECHNICAL ASSISTANCE AGREEMENT,

DISTRIBUTION AGREEMENT OR OFF-SHORE PROCUREMENT AGREEMENT APPROVED BY

THE DIRECTORATE OF DEFENSE TRADE CONTROLS WITH THE OFFER, UNLESS AN

EXEMPTION UNDER THE PROVISIONS OF ITAR SECTION, 125.4 EXEMPTIONS OF

GENERAL APPLICABILITY<(>,<)> AND/OR EAR PART 740 ARE APPLICABLE.

NON-JCP CERTIFIED SUPPLIERS SEEKING EXPORT CONTROLLED TECHNICAL

DATA ARE REQUIRED TO PROVIDE THE CONTRACTING OFFICER WITH AN

APPLICABLE AGREEMENT OR IDENTIFY WHICH ITAR/EAR EXEMPTION APPLIES TO

RECEIVE A COPY OF THE EXPORT CONTROLLED TECHNICAL DATA.

NOTE: JCP CERTIFIED CONTRACTORS WHO RECEIVE TECHNICAL DATA PURSUANT TO

THEIR DD FORM 2345 CERTIFICATION MAY NOT FURTHER DISSEMINATE SUCH DATA

UNLESS FURTHER DISSEMINATION OF THE TECHNICAL DATA IS EXPRESSLY

PERMITTED BY DODD 5230.25.

REFERENCE NUMBER ZD059

52.246-11 Higher Level Contract Quality Requirement (Manufacturers)

FAR CLAUSE 52.246-11 APPLIES. A QUALITY MANAGEMENT PROGRAM MEETING THE

REQUIREMENTS OF ISO 9001:2008; A PROGRAM COMPARABLE TO ISO 9001:2008

(EXAMPLE SAE AS 9100), THE FOLLOWING TAILORED VERSION OF ISO 9001:2008;

OR A PROGRAM COMPARABLE TO THE TAILORED VERSION OF ISO 9001:2008

(EXAMPLE SAE AS 9003) IS REQUIRED. MIL-I-45208 AND MIL-Q-9858 ARE

OBSOLETE AND NO LONGER CONSIDERED SUITABLE WHEN HIGHER LEVEL QUALITY IS

REQUIRED. IN THE TAILORED VERSION OF THE ISO 9001:2008, ANY REFERENCES

WHICH CITE THE ENTIRE INTERNATIONAL STANDARD ARE INTERPRETED AS

EXCLUSIONS TO THIS DOCUMENT.

DLA TAILORED HIGHER LEVEL QUALITY CLAUSE FROM ISO 9001:2008

4.1 General requirements, [excluding reference to 1.2 and excluding NOTE 3 c)]

4.2.1 General, [excluding subparagraph a)]

4.2.2 Quality manual, [excluding subparagraph a)]

4.2.3 Control of documents

4.2.4 Control of records

5.1 Management commitment

5.3 Quality policy

6.2.2 Competence, training and awareness

6.4 Work environment

7.1 Planning of product realization, [excluding NOTE 2]

7.2.1 Determination of requirements related to the product

7.2.2 Review of requirements related to the product

7.2.3 Customer communication

7.3.7 Control of design and development changes

7.4.1 Purchasing process

7.4.3 Verification of purchased product

7.5.1 Control of production and service provision

7.5.3 Identification and traceability

7.5.4 Customer property

7.5.5 Preservation of product

7.6 Control of monitoring and measuring equipment

8.1 General, [excluding subparagraph b) and subparagraph c)]

8.2.2 Internal audit

8.2.4 Monitoring and measurement of product

8.3 Control of nonconforming product

8.5.2 Corrective action

8.5.3 Preventive action

REFERENCE NUMBER CS147

"THIS NSN CONTAINS ONE OR MORE COMPONENTS WHICH

MUST CONFORM TO SOURCE CONTROL DRAWING. BY

SUBMITTING AN OFFER, THE OFFEROR AGREES TO

PROVIDE SOURCE CONTROLLED COMPONENTS FROM

SOURCES APPROVED ON THE APPLICABLE SOURCE

CONTROL DRAWING."

REFERENCE NUMBER ZD054

CERTIFICATE OF CONFORMANCE PROCEDURES (FAR 52.246-15) ARE AUTHORIZED,

UNLESS WITHELD BY A QUALITY ASSURANCE LETTER OF INSTRUCTION.

REFERENCE NUMBER CQ009

IF AQLS ARE LISTED IN THE SPECIFICATION(S)

OR DRAWING(S) THEY MAY BE USED TO ESTABLISH THE

AUTHORIZED SAMPLE SIZE,HOWEVER,THE ACCEPTANCE

NUMBER FOR THIS CONTRACT IS ZERO;I.E.,THIS

CONTRACT REQUIRES A SAMPLING PLAN THAT ACCEPTS

ON ZERO DEFECTS AND REJECTS ON ONE OR MORE

DEFECT(S).

REFERENCE NUMBER CQSL6

THIS SHELF LIFE ITEM IS EXTENDABLE, CODE 6,

WITH A TOTAL SHELF LIFE OF TWENTY-FOUR MONTHS.

MATERIAL FURNISHED UNDER THIS CONTRACT/ORDER

SHALL HAVE AT LEAST 85% (21 MONTHS) OF THE SHELF

LIFE REMAINING AT TIME OF DELIVERY.

REFERENCE NUMBER CS187

CLASS I OZONE DEPLETING CHEMICALS ARE NOT TO BE

USED NOR INCORPORATED IN ANY ITEMS TO BE

DELIVERED UNDER THIS CONTRACT.THIS PROHIBITION

SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT

DOES NOT ALLEVIATE ANY PRODUCT REQUIREMENTS.

SUBSTITUTE CHEMICALS MUST BE SUBMITTED FOR

APPROVAL UNLESS THEY ARE AUTHORIZED BY THE

SPECIFICATION REQUIREMENTS.

REFERENCE NUMBER CS086

THIS NSN CONTAINS ONE OR MORE COMPONENTS WHICH

MUST MEET QPL/QML SPECIFICATIONS.BY SUBMITTING

AN OFFER, THE OFFEROR AGREES TO PROVIDE QPL/QML

COMPONENTS ONLY FROM SOURCES QUALIFIED ON THE

APPLICABLE QPL(S)/QML(S).

REFERENCE NUMBER CA070

FULL AND OPEN COMPETITION APPLY