SOW - Redacted.pdf
PDF 444 KB Posted
- Attached to
- Barge Shock Test Federal contract opportunity
- Solicitation number
- N0017821Q6998
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF18 Extended.pdf | ||
| 0618-02 - Barge Shock Test - Fixed Site AVCAD 901E Barge Matrix 06JUN2021.xlsx | XLSX spreadsheet | |
| 0618-02 - Barge Shock Test - DWG 5038598 CDU Assembly.pdf | ||
| 0618-02 - Barge Shock Test - DWG 5038597 Detection Unit Assembly.pdf | ||
| 0618-02 - Barge Shock Test - DID DI-MISC-80508B.pdf | ||
| SF18 Released.pdf | ||
| 0618-02 - Barge Shock Test - DWG 5038599 EASU Assembly.pdf | ||
| 0618-02 - Barge Shock Test - Terminal Box Assembly 404-525-REV-A.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIXED SITE AEROSOL AND VAPOR CHEMICAL AGENT DETECTOR (AVCAD)
MIL-STD-901E HEAVY WEIGHT SHOCK TESTING
STATEMENT OF WORK (SOW)
1.0 BACKGROUND
The Naval Surface Warfare Center, Dahlgren Division (NSWCDD) requires heavy weight shock testing for multiple test assets to meet Grade A shock.
2.0 APPLICABLE DOCUMENTS
2.1 MIL-DTL-901E; Shock Tests, H.I. (High-Impact) Shipboard Machinery, Equipment, and Systems, Requirements for 20 June 2017
2.2 Fixed Site AVCAD 901E Barge Matrix, dated 06JUN2021
2.3 DWG 5038597 Detection Unit Assembly
2.4 DWG 5038598 CDU Assembly
2.5 DWG 5038599 EASU Assembly
2.6 Terminal Box Assembly 404-525-REV-A
3.0 REQUIREMENTS
3.1 The Contractor shall conduct a heavyweight shock test in accordance with MIL-DTL- 901E for the Government Furnished Equipment/Materials (GFE/M) listed in Section 6 (2 systems consisting of 4 items each) of this SOW at three deck frequencies, with the main deck frequency at 8Hz and 14Hz and the secondary smaller cross deck at 25Hz. The contractor shall meet the following additional requirements under this SOW:
3.1.1 Design and build mounting fixtures for the subject testing 8 items, in accordance with sections 2.3 through 2.6.
3.1.2 Offload and install equipment onto the test fixture and prepare for testing.
3.1.3 Provide all power to units under test in accordance with Section 2.2.
3.1.4 Provide no less than eighteen (18) channels for instrumentation on customer equipment.
3.1.5 Provide instrumentation to monitor and verify test inputs to the Floating Shock Platform (FSP) and to the units under test.
3.1.6 Conduct shot series as documented in section 2.2
3.1.7 Remove and repackage units under test after testing is complete.
3.1.8 Provide a Contingency Fee line item in the quote for 15% of the total contract. Line item will be included on the purchase order of a not to exceed (NTE) line item.
3.2 The contractor shall coordinate with the technical point of contact listed in Section 6.0 below to schedule the shipment of all Government Furnished Equipment/Materials (GFE/M) and work to be performed under this statement of work. Work shall begin no later than fourteen (14) calendar days after award of contract. The contractor shall start testing within sixty (60) calendar days after contract award.
4.0 DELIVERABLES
4.1. Test Report IAW CDRL A001.
5.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIALS (GFE/M)
The Government will provide the following GFE/M:
5.1 Smith’s Detection Fixed Site AVCAD System, quantity 1 – Total Value $180,000
5.1.1 Detector Unit (S-DU) - quantity 1 – Value $100,000
Approximate Dimensions: 12.5"W x 12"D x 25.5"T; Approximate Weight: 50 lbs
5.1.2 Control Display Unit (S-CDU) - quantity 1 – Value $50,000
Approximate Dimensions: 14.5"W x 11"D x 11"T; Approximate Weight: 18 lbs
5.1.3 External Air Sampling Unit (S-EASU) – quantity 1 – Value $30,000
Approximate Dimensions: 8"W x 3.5"D x 18"T; Approximate Weight: 16 lbs
5.2 Chemring Detection Fixed Site AVCAD System, quantity 1 – Value $180,000
5.2.1 Detector Unit (C-DU) - quantity 1 – Value $100,000
Approximate Dimensions: 12.5"W x 12"D x 25.5"T; Approximate Weight: 65 lbs
5.2.2 Control Display Unit (C-CDU) - quantity 1 – Value $50,000
Approximate Dimensions: 14.5"W x 11"D x 11"T; Approximate Weight: 18 lbs
5.2.3 External Air Sampling Unit (C-EASU) – quantity 1 – Value $30,000
Approximate Dimensions: 8"W x 3.5"D x 18"T; Approximate Weight: 16 lbs
5.3 Terminal Box (TB) – quantity 2 – Value $1,000 each
Approximate Dimensions: 15"W x 14"D x 13"T; Approximate Weight: 10 lbs
5.4 The Government will provide all miscellaneous test item equipment, mounting hardware, interconnecting cables, operational and checkout hardware.