0618-02 - Barge Shock Test - Fixed Site AVCAD 901E Barge Matrix 06JUN2021.xlsx

XLSX spreadsheet 2 MB Posted

Attached to
Barge Shock Test Federal contract opportunity
Solicitation number
N0017821Q6998
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

DISTRIBUTION STATEMENT C. Distribution authorized to U.S. Government agencies and their contractors; critical technology; 3 February 2021. Other requests shall be referred to U.S. Army, contractors; critical technology; 3 February 2021. Other requests shall be referred to U.S. Army, SFAESFAE—CBD
All detector images and information are subject to handling as proprietary or program sensitive information
Aerosol Vapor Chemical Agent Detector Fixed Site (AVCAD-FS) Barge Test Matrix
ItemSmith's Detector Unit
(S-DU)Smith's Control Display Unit
(S-CDU)Smith's External Air Sampling Unit

(S-EASU)

+ Aerosol Vapor Converter (AVC)Chemring Detector Unit
(C-DU)Chemring Control Display Unit
(C-CDU)Chemring External Air Sampling Unit
(C-EASU)Terminal Box

(TB)

(already qualified but needed for connectivity of 2 systems)

GradeAAAAAAN/A
Equipment ClassIIIIIIIIIII
Equipment TypePrincipal UnitPrincipal UnitPrincipal UnitPrincipal UnitPrincipal UnitPrincipal UnitPrincipal Unit
Shock Test TypeAAAAAAN/A
Mounting LocationDeckDeckDeckDeckDeckDeckDeck
Mounting PlaneBackBackBackBackBackBackBack/Base
AxisVertical Axis SpecifiedVertical Axis SpecifiedVertical Axis SpecifiedVertical Axis SpecifiedVertical Axis SpecifiedVertical Axis SpecifiedN/A
Number of Op Modes211211N/A
Deck Frequency (Hz)8, 148, 14258, 148, 142525
Item Weight (lb)50181665181610
Quantity1111112
Item Dimension [including sway space]12.5"W x 12"D x 25.5"T14.5"W x 11"D x 11"T8"W x 3.5"D x 18"T12.5"W x 12"D x 25.5"T14.5"W x 11"D x 11"T8"W x 3.5"D x 18"T15"W x 14"D x 13"T
Power120VAC, 1-phase, 3.0A120VAC, 1-phase, 1.5AGets power from S-DU120VAC, 1-phase, 7.0A120VAC, 1-phase, 2.0AGets power from C-DUN/A
Mounting HardwareTBDTBDTBDTBDTBDTBDTBD
ShotsSmith's Detector Unit
(S-DU)Smith's Control Display Unit
(S-CDU)Smith's External Air Sampling Unit

(S-EASU)

+ Aerosol Vapor Converter (AVC)Chemring Detector Unit
(C-DU)Chemring Control Display Unit
(C-CDU)Chemring External Air Sampling Unit
(C-EASU)Terminal Box

(TB)

(already qualified but needed for connectivity of 2 systems)

901E
#Deck Freq (Hz)Charge Weight (lb)Charge Depth (ft)Charge Distance (ft)
314,25602425Athwartship
(2nd Op Mode)AthwartshipAthwartshipAthwartship
(2nd Op Mode)AthwartshipAthwartshipAthwartship
414,25602420AthwartshipAthwartshipAthwartshipAthwartshipAthwartshipAthwartshipAthwartship
4R14,25602420Fore-AftFore-AftFore-AftFore-AftFore-AftFore-AftFore-Aft
4AR8602420Fore-AftN/AN/AFore-AftN/AN/AN/A
4A8602420AthwartshipN/AN/AAthwartshipN/AN/AN/A
Notional Barge Layout
Functional/Interconnect Diagram for both systems
Pictures of Legacy equipment being tested on barge in 2010
Diagrams of Smith's Equipment (CSES equipment will be nearly identical)
DU

CDU and RDU

S-EASU

TB

image1.PNG image2.png image3.png image4.png image5.png image6.png