SOW_N4044322Q0057_KAISER_PTO.pdf
PDF 12 KB Posted
- Attached to
- USNS HENRY J. KAISER PTO SERVICE
- Solicitation number
- N4044322Q0057
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USNS KAISER
(T-AO 187)
N32205-19-R-4066
FEB 2020
ITEM NO. 306 CATEGORY "A" MSC/N75/BJD
PTO GROOM
1.0 ABSTRACT
1.1 Provide services of a Qualified Technical Field Service Representative to conduct system operational testing, troubleshooting, adjustments and repairs to the port and
Stbd PTO cabinets and control systems.
2.0 REFERENCES/ENCLOSURES:
2.1 NAVSEA Tech Manual T9311-A9-MMC-020, " PTO Generator" )
3.0 ITEM LOCATION/DESCRIPTION
3.1 Description
3.1.1 Two (2) Power Take Off Generator Sets, 3-91-1/2
3.1.1.1 GEC ALSTHOM INTL INC; 2500 kw; 60Hz; 450 Volts
3.2 Quantity
3.1.1 Two (2) Power Take Off Generator Sets include the following;
3.2.1.1 PTO Generator Control Circuitry (2 Sets; 1 Ea. PTO Generator)
3.2.1.2 Two (2) PTO Generator equipment
3.2.1.3 Two (2) PTO Group Control Centers
3.2.1.4 Auxiliary Apparatus Cabinet
3.2.1.5 Network Bridge
3.2.1.6 Machine Bridge
3.2.1.7 Static Frequency Converter
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES:
4.1 None
5.0 NOTES:
5.1
5.2
6.0 QUALITY ASSURANCE REQUIREMENTS:
6.1 None Additional.
7.0 STATEMENT OF WORK REQUIRED
7.1 Provide the services of a Qualified Technical Field Service Representative to conduct system troubleshooting, testing, adjustments and repairs to the port PTO
Variable Frequency Drive and control systems for a total of nine (9) days.
7.1.1 The contractor shall provide the Technical representative for a period of nine (9) ten (10) hour days .
USNS KAISER
(T-AO 187)
N32205-19-R-4066
FEB 2020
ITEM NO. 306 CATEGORY "A" MSC/N75/BJD
PTO GROOM
7.2 Perform the following troubleshoot and repairs.
a. Full function test of No2 PTO Variable Frequency Drive on board
b. Check of all power cable connections
7.3 Technical Representative is to be aboard during the Dock Trials as part of the nine
(9) days of the availability.
7.3.1 Qualified Technical Field Service Representative POC;
Lange Energy & Drives 8 Bryce Industrial Drive
Savannah, GA 31405
Tel 1-954-829-4256
Email support@langeED.com
7.4 An RFP shall be issued for all required parts and material deemed necessary during the inspection and testing of the PTO Cabinets and Control Systems.
7.5 Upon completion of all work a technical field service trip report is to be submitted to the
Port Engineer documenting action taken and recommendations for future repairs/modifications.
8.0 GENERAL REQUIREMENTS
8.1 All work shall be accomplished to the satisfaction of the MSCREP.
File details come from the government source that posted it. Updated .