AutoCAD SHX Text Approved: Division Chief
AutoCAD SHX Text Approved: Service Director
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text
65, 66 & 68 ONE LINE
AutoCAD SHX Text
HOT SPRINGS BUILDINGS
AutoCAD SHX Text Checked
AutoCAD SHX Text
HOT SPRINGS, SOUTH DAKOTA
AutoCAD SHX Text Location
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Title
AutoCAD SHX Text Sept. 2012
AutoCAD SHX Text
DS
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. Of
AutoCAD SHX Text Project No.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text Date
AutoCAD SHX Text
TF-66
AutoCAD SHX Text
TO 15KV
AutoCAD SHX Text
SWITCHES
AutoCAD SHX Text
PRI: 12,470Y/7200V
AutoCAD SHX Text
PAD MOUNTED TRANSFORMER
AutoCAD SHX Text
SEC: 208/120V
AutoCAD SHX Text
225 KVA, 3PH., 4W
AutoCAD SHX Text
IMP. 3.5
AutoCAD SHX Text
AutoCAD SHX Text
FIRE STATION, FORMER INCINERATOR
AutoCAD SHX Text
BUILDING 66/68
AutoCAD SHX Text M
AutoCAD SHX Text
800AF
AutoCAD SHX Text
800AT
AutoCAD SHX Text 100A
AutoCAD SHX Text 60A
AutoCAD SHX Text 200A
AutoCAD SHX Text 150A
AutoCAD SHX Text 400A
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
PANEL
AutoCAD SHX Text A
AutoCAD SHX Text
PANEL
AutoCAD SHX Text B
AutoCAD SHX Text
WH1
AutoCAD SHX Text
25 KW
AutoCAD SHX Text
WP
AutoCAD SHX Text 100A/3P
AutoCAD SHX Text
21.6 KW
AutoCAD SHX Text
CD1
AutoCAD SHX Text
MA1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
800A BUS
AutoCAD SHX Text
FIRE STATION
AutoCAD SHX Text
BUILDING 66
AutoCAD SHX Text
DIAGRAM
AutoCAD SHX Text 100A
AutoCAD SHX Text 150A. 208V, 3 phased disconnect. Mount
AutoCAD SHX Text to unistrut pedestal. 48" above ground.
AutoCAD SHX Text Install new 208V, 150A Frame, AutoCAD SHX Text 100 A trip, 3 pole, thermal magnetic, AutoCAD SHX Text SELT 22 kA Interrupt Rating.
AutoCAD SHX Text
(3) 1 AWG and (1) 6 AWG conductors
AutoCAD SHX Text in 2-1/2" HDPE conduit.
AutoCAD SHX Text Disconnect to provide power for new building.