SOURCES SOUGHT.docx
DOCX document 16 KB Posted
- Attached to
- Vertical Contour Bandsaw - Sources Sought Only Federal contract opportunity
- Solicitation number
- FA6712-BANDSAW
About this file
This document is a sources sought notice for a vertical contour bandsaw. Pittsburgh Air Reserve Station requires a bandsaw with a footprint no larger than 56" L x 44" W x 80" H and a table size minimum of 14" x 14". Electrical requirements include 460V/60Hz/3-ph power and variable frequency drives for the band motor. The bandsaw must have T-slots, hydraulic feed control, 45 degrees of table tilt, and welding/grinding capabilities. Responses are due no later than July 7, 2023 at 4:00pm Eastern and should include company information and small business classification. The related federal contract opportunity has solicitation number FA6712-BANDSAW and is a sources sought only notice for a vertical contour bandsaw from the Department of the Air Force Reserve Command.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOURCES SOUGHT: THIS IS NOT A NOTICE OF REQUEST FOR QUOTATION BUT INFORMATION AND PLANNING PURPOSES ONLY! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.
Pittsburgh Air Reserve Station, Coraopolis, PA anticipates a requirement for a vertical contour bandsaw. The North American Industry Classification Systems (NAICS) Code proposed is 333517 – Machine Tool Manufacturing and the size standard for NAICS is 500 employees.
The requirement is to provide: Vertical Contour Bandsaw for Metals Shop, Bldg 417
Salient Characteristics:
| Footprint Maximum: | 56” L x 44” W x 80” H | |||
| Table Size minimum: | 14” x 14” | |||
| Electrical Requirements: | Must be 460V/60Hz/3-ph | |||
| Band Motor: | Must contain a Variable Frequency Drive | |||
| Blade Width Capacity: | 1/8” to 1” | |||
| Blade Length: | 154” | |||
| Band Speed: | 30-320 FPM (low range) | |||
| 550-5500 FPM (high range) | ||||
| Band Tension: | Manual | |||
| Material Pass Height: | 39 Inches | |||
| Electrical Controls: | Must be mounted | |||
| Table Features: | Must have “T” slots for fixture mounting to prevent material from moving during cutting (12 inches of travel) | |||
| Feed Control: | Mus have Hydraulic Feed Control to maximize band life | |||
| Table Tilt: | At least 45 Degrees Negative to at least 10 Degrees Positive | |||
| Welder/Grinder: | Welder with grinder for 460 Volt | |||
| Interlock: | Band door interlocks, so the band cannot be started while the doors are open | |||
| Preset Band Tension Device: | Allows the operator/user to correctly tension the blade during the band change | |||
| Installation: | Must be provided by OEM or authorized representative as designated in writing (electrical connection ready). | |||
| Training: | Provide on-site operator/user training |
Shall include the following:
| - | Emergency Stop Button, Blade Start Button, and Blade Stop Button |
| - | Blade Guard and Tension control device IAW OSHA 1910.213 |
| - | Work holding jaw with handles |
| - | Work holding vice to fit table “T” slots |
| - | Magnetic wand chip remover |
| - | Flood coolant |
| - | Work Light |
| - | Chip Box |
| - | Chip Blower |
| - | Saw Blade Guards |
| - | Band Mist Lubricator |
| - | Table Feed Control |
| - | Post Elevating Hand Wheel |
| - | Tool saver lubricant stick |
| - | 5-gallon pail of mist coolant |
| - | Option for extended warranty on the machine (10 year) |
NOTE: RESPONSES TO THIS SOURCES SOUGHT SHALL STATE IF THEY ARE A SUPPLIER OR MANUFACTURER!
No assumptions will be made regarding capabilities. Firms must submit sufficient information to assist the Contracting Officer in making a determination regarding capabilities.
Please note: All contractors doing business with the Federal Government must be registered in the System for Award Management (SAM) database. The website for registration is www.sam.gov.
Responses may be submitted electronically to Paul Davisson at paul.davisson@us.af.mil. Telephone responses will not be accepted.
RESPONSES ARE DUE NO LATER THAN 07/7/2023 at 4:00pm Eastern.
Future information about this acquisition, including issuance of a quotation and/or applicable amendments, will be issued through Contracting Opportunities at sam.gov. Interested parties are responsible for ensuring they have the most up-to-date information regarding this acquisition.
Please complete the Contractor Survey on the following page:
Please provide the following information:
Company/Institute Name:
Address:
Point of Contact:
CAGE Code:
Phone Number:
E-mail Address:
Size of business pursuant to North American Industry Classification System (NAICS) Code:
333517; small business size standard 500 Employees.
Based on the above NAICS Code, state whether your company is:
Small Business (Yes / No) Woman Owned Small Business (Yes / No) Small Disadvantaged Business (Yes / No) 8(a) Certified (Yes / No) HUBZone Certified (Yes / No) Veteran Owned Small Business (Yes / No) Service Disabled Veteran Small Business (Yes / No)
Responses may be submitted electronically to Paul Davisson at paul.davisson@us.af.mil. Telephone responses will not be accepted.
RESPONSES ARE DUE NO LATER THAN 07/7/2023 at 4:00pm Eastern.
File details come from the government source that posted it. Updated .