J041--PCU AHU REPLACEMENT AT DC VAMC
Solicitation number
36C24525Q0798
Issued by

About this file

This document contains a Statement of Work (SOW) and a Request for Information (RFI) for a Rooftop Air Handling Unit (AHU) Replacement project at the DC VA Medical Center. The SOW details the replacement of existing rooftop AHUs on the fourth floor of Building #1, requiring comprehensive removal of existing equipment, installation of a new Roof Top Unit (RTU) with a TempMaster unit (8.5 tons cooling capacity, 3,600 CFM), 8 Variable Air Volume (VAV) units with electric reheat, and associated control systems based on Siemens Control technology. The contractor must perform power disconnection, equipment removal, new installation, system testing, documentation, and site restoration.

The accompanying RFI seeks responses from interested and capable vendors by 10:00 AM ET on 8/25/2025, submitted via email to John Ritter. Respondents must provide details including business name, type, socio-economic status, contact information, capability statement, previous experience with Veterans Health Administration, available contract vehicles, service categories, certifications, and confirmation of self-performance or subcontracting capabilities. The RFI is for market research purposes only and does not constitute a solicitation, with the results potentially influencing the acquisition strategy (such as set-asides or competition type).

View the file

Other files

File Type Posted
36C24525Q0798.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

Replacement of Existing Rooftop AHU with New Single RTU (Serving the Fourth Floor B Section of Building #1)

1. Power Disconnection and Lockout/Tagout (LOTO) Procedures. The contractor shall identify and isolate the electrical power supply to the existing AHU unit and associated electric reheat components. Power shall be turned off and appropriately locked out and tagged at the electrical panel, in accordance with standard Lockout/Tagout (LOTO) procedures, before commencing any work.

2. Removal of Existing Equipment. The contractor shall remove the existing two rooftop AHUs from the roof. The existing ductwork, roof curb, and all other components associated with the existing units shall also be removed. The contractor shall ensure the space below is protected from rain during construction until the work is completed. The contractor shall remove the existing air distribution system, including all associated terminal boxes, electric reheat units, VVT controls, wiring, and devices. The contractor shall remove existing ceiling tiles and grid systems to facilitate demolition and installation. Fire alarms, sprinkler heads, smoke alarms, and other critical systems shall be carefully removed and set aside for reuse. The contractor shall follow infection control procedures when removing debris from the space. The COR will provide a written document outlining the infection control protocols.

3. Installation of New RTU. The contractor shall provide and install a new roof curb designed for a new downdraft RTU package. The roof curb installation should be integrated into the deck, not placed on top of insulation or roofing materials. The curb should be at least eight inches above the finished roof surface and be factory-insulated.

The contractor shall install the new RTU on the new roof curb, following the manufacturer's installation guidelines.

The contractor shall provide and install 8 Variable Air Volume (VAV) units with electric reheat and associated thermostats. The VAVs shall be sized to meet the required air supply. The contractor shall ensure the system is properly air-balanced and shall provide a Test and Balance (TAB) report to the Government upon completion. All air distribution ductwork in the space shall be provided and installed by the contractor. The ductwork shall be rated for medium pressure and comply with SMACNA standards. All ductwork shall be sealed to ensure air leakage does not exceed 0.01%. All supply ductwork shall be insulated with 1.5-inch external insulation. New control systems shall be based on Siemens Control technology. The RTU will be a TempMaster unit with a cooling capacity of 8.5 tons, providing 3,600 CFM with a 3 HP motor and high static pressure. Sizing calculations are based on 8 Air Changes (AC) per hour for cooling mode and 7 AC per hour for heating mode.

4. System Testing and Demonstration The contractor shall perform a full demonstration of the newly installed system, including the control systems, to show the operational sequence to the Government representative.

5. Documentation and Warranties. Upon project completion, the contractor shall provide all necessary as-built drawings, warranties, and operational manuals for the new equipment.

6. Site Restoration and Clean-Up. After completing the installation and testing, the contractor shall clean the work area, removing all dirt, debris, and construction materials. The site shall be restored to its original condition.

Interested & Capable Responses:

NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the PCU AHU REPLACEMENT at DC VA Medical Center.

Please respond to this RFI/Sources Sought 36C24525Q0798 with your:

1. Business name (including Unique Entity ID (SAM.gov)

2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged

Small Business, 8(a), etc.), and

3. Person of contact (including telephone number & email address).

4. Capability statement and summary of previous experience providing these types of services for the

Veterans Health Administration or other similar facilities.

5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable

NAICS)

6. Brief Summary of categories of services that your company can/cannot provide.

7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC

VAMC (if applicable)

8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response:

a. Do you intend to self-perform this effort?

b. If you are located outside the immediate area, how will you self-perform?

c. Or do you intend to subcontract work under this contract?

d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?

Response Instructions:

Responses must be submitted by 10:00 AM (ET) 8/25/2025. Responses to the information requested above must be submitted via email to John Ritter at John.Ritter2@va.gov.

This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred as a result of a vendor’s attendance to the Site-Visit nor the preparation of responses submitted as a result of this notice.

John Ritter Contracting Officer

VHA, NCO 5

John.Ritter2@va.gov mailto:John.Ritter2@va.gov mailto:John.Ritter2@va.gov

STATEMENT OF WORK

File details come from the government source that posted it. Updated .