B.05_EB-CM.pdf

PDF 2 MB Posted

Attached to
Representational Kitchen Renovation Federal contract opportunity
Solicitation number
SIT70017R0007
Issued by
Department of State US Embassy Rome

About this file

B.05

View the file

Other files for this federal contract opportunity

Other files attached to Representational Kitchen Renovation, newest first.
File Type Posted
NEW_B.04_layout_of_site.pdf PDF
Amendment_0001___2017-06-09-175431.pdf PDF
B.a03.pdf PDF
SF-1442_FLORENCE_Rep_Kitchen.docx DOCX document
B.s02.pdf PDF
B.p01.pdf PDF
B.s01.pdf PDF
document_check_list.pdf PDF
B.a02.pdf PDF
B.01_technical specifications.pdf PDF
Rep_Kitchen_RFP_Florence.docx DOCX document
B.p03.pdf PDF
B.p02.pdf PDF
B.p04.pdf PDF
B.00_report.pdf PDF
Inv_Ltr_Florence2017-05-17-103152.pdf PDF
B.p05.pdf PDF
B.03_plan of the work.pdf PDF
B.a04.pdf PDF
B.a01.pdf PDF
B.04_layout of site.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Studio DDM architetti associati viale Europa, 331 - 00144 Roma page 2

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

MEASURED WORK

ARCHITECTURAL INTERVENTIONS (SpCat 1) Provisional works (Cat 1)

1 Mobile scaffolding on wheels for heights up to 3.6 m A15030a - period of use: 4 months 1,00

TO SUM cad 1,00

Assemble and dis-assemble rack elevator ( hoist).

2 Assemble and dis-assemble rack elevator ( hoist).

A15008 1,00

TO SUM cad 1,00

Leasing of rack elevator ( hoist).Noleggio di elevatore a cremagliera (montacarichi)

3 Leasing of rack elevator ( hoist).Noleggio di elevatore a cremagliera A15007a (montacarichi)

- period of use: 4 months 4,00

TO SUM cad 4,00

4 Telescopic cherry picker, for each working day: height 20.00 m, 15.00 m A04.01.020.a outreach, capacity 400 kg,accio 15,00 m, portata 400 kg,

- for execution of air expulsion, east facade 2,00

TO SUM giorno 2,00

Partial Provisional works (Cat 1) euro

Removal, Dismantling, Transport (Cat 2)

5 Excavation in set section, including leveling of the bottom, the lifting of the A02.01.003.b excavated material to a safe position, any shoring, performed by mechanical means, including the loading on means of transport, backfilling and restoring the site

- pit for grease separator *(eq. parts=1,4*3,6*1,3) 6,55

TO SUM m³ 6,55

Demolition of flooring made of marble slabs, gres or ceramics

6 Demolition of flooring made of marble slabs, gres or ceramics A25047 - first floor 47,00

- first floor mezzanine, wc 5,00

TO SUM mq 52,00

Demolition of sub-base in lime mortar

7 Demolition of sub-base in lime mortar A25058 - first floor, envisaged 5 cm *(eq. parts=47*0,05) 2,35

- piano primo mezzanine, wc envisaged 5 cm *(eq. parts=5,0*0,05) 0,25

TO SUM mc 2,60

CLIENT: EMBASSY OF THE UNITED STATES OF AMERICA - ROME, ITALY

T O C A R R Y - O V E R viale Europa, 331 - 00144 Roma page 3

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

8 Demolition of ceramic covering A25059 - first floor 22,50

- first floor mezzanine, wc *(eq. parts=11,25*1,6) 18,00

TO SUM mq 40,50

Remove skirting board made of rubber or PVC

9 Remove skirting board made of rubber or PVC A25067 - first floor 39,00

TO SUM m 39,00

Demolition of partitions made of hollow bricks

10 Demolition of partitions made of hollow bricks A25031b - first floor, partitions 35,60

TO SUM mq 35,60

Remove inner wooden doors up to 3.00 sq.m

11 Remove inner wooden doors up to 3.00 sq.m A25104 - first floor, n° 2 4,20

TO SUM mq 4,20

Remove distribution network and terminals.

12 Remove distribution network and terminals.

A03.02.016.b first floor

- wc + flush tank 2,00

- sink 1,00

- kitchen sink 1,00 first floor mezzanine

- wc + flush tank 2,00

- sink 1,00

- shower plate 1,00

TO SUM cad 8,00

13 Removing fixed furnishings, measured on the front surface.

PA.01.01 - first floor, cupboards and shelves 24,00

TO SUM mq 24,00

Lifting or lowering materials by means of mechanical elevator: evaluated on the volume

14 Lifting or lowering materials by means of mechanical elevator: evaluated on A25124b the volume waste materials

- floors *(eq. parts=(47+5)*0,05) 2,60

- screeds *(eq. parts=(47+5)*0,05) 2,60

- coverings *(eq. parts=(22,5*0,03)+(11,25*1,6)) 18,68

- skirting board *(eq. parts=39*,1*0,01) 0,04

- partitions *(eq. parts=35,6*,12) 4,27

- bathroom fixtures *(eq. parts=(4+4)*,35*,65*,4) 0,73

Partial mc 28,92

- extra for loose material (2x) 28,92

- supplies 32,00

Partial mc 60,92

TO SUM mc 89,84 viale Europa, 331 - 00144 Roma page 4

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

15 Transport waste material from the demoliton to an authorized dump A25119 - waste materials *(eq. parts=28,92*2) 57,84

- material from exavation 6,55

TO SUM mc 64,39

Fees owed to authroized dumps

16 Fees owed to authroized dumps A25120a - waste material 57,84

- material from excavation 6,55

TO SUM mc 64,39

Partial Removal, Dismantling, Transport (Cat 2) euro

Screed, flooring (Cat 3)

Isolating screeds made of concrete and expanded clay

17 Isolating screeds made of concrete and expanded clay A65115c - first floor *(eq. parts=47*0,05) 2,35

- first floor mezzanine, wc *(eq. parts=5,0*0,05) 0,25

TO SUM mc 2,60

Partial Screed, flooring (Cat 3) euro

Masonry works, (Cat 4)

Partitions made of monlythic, autoclaved, cellular concrete blocks, measuring 25 x 62,5 x 7,5 cm, density 600 kg/m³, resistance to fire - class REI 120

18 Partitions made of monlythic, autoclaved, cellular concrete blocks, measuring A65109a 25 x 62,5 x 7,5 cm, density 600 kg/m³, resistance to fire - class REI 120

- first floor, partitions 40,70

TO SUM mq 40,70

19 Masonry work to mechanical, hydro sanitary and drainage systems

PA.04.01 1,00

TO SUM a corpo 1,00

20 Masonry work to electrical and special systems

PA.04.02 1,00

TO SUM a corpo 1,00

21 Repairing damaged plaster on the walls with mortar similar to the existing.

A12.01.016 Work includes the prior removal of the damaged part and cleaning

- first floor mezzanine, Toscana suite *(eq. parts=53,8*,3) 16,14

TO SUM m² 16,14 viale Europa, 331 - 00144 Roma page 5

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

Partial Masonry works, (Cat 4) euro

Floor, Covering (Cat 5)

Floor made of porcelained gres with slip-proof factor R=10, size 150 x 150 cm, thickness 6 mm, plain color, installed with suitable adhesive and joints connected with white cement

22 Floor made of porcelained gres with slip-proof factor R=10, size 150 x 150 B45027a cm, thickness 6 mm, plain color, installed with suitable adhesive and joints connected with white cement

- first floor, kitchen 46,00

TO SUM mq 46,00

Floor made of porcelained gres with slip-proof factor R=10, size 75 x 75 cm, thickness 6 mm, plain color, installed with suitable adhesive and joints connected with white cement

23 Floor made of porcelained gres with slip-proof factor R=10, size 75 x 75 cm, B45029a thickness 6 mm, plain color, installed with suitable adhesive and joints connected with white cement

- first floor, wc 4,30

- first floor mezzanine, wc 5,00

TO SUM mq 9,30

Wall covering made of porcelained gres 75 x 37,5 cm, natural finish, installed with suitable adhesive and joints connected with white cement

24 Wall covering made of porcelained gres 75 x 37,5 cm, natural finish, installed B45155c with suitable adhesive and joints connected with white cement

- first floor, kitchen and wc, h=2,25 138,95

- first floor mezzanine, wc, h=2,25 *(eq. parts=10*2,25) 22,50

TO SUM mq 161,45

AISI 304 steel fittings between tiled surfaces, including internal, external and tri-axial angular fittings

25 AISI 304 steel fittings between tiled surfaces, including internal, external and PA.05.01 tri-axial angular fittings first floor

- floor shell/covering 60,50

- shell corners/ covering 38,30

- section corners/ covering 42,80

TO SUM 141,60

Partial Floor, Covering (Cat 5) euro

Windows (Cat 6)

Repairing existing windows, including dismantling, transporting to laboratory and returning, re-installing and painting

26 Repairing existing windows, including dismantling, transporting to laboratory C25004 and returning, re-installing and painting

- first floor, wc 1,60

TO SUM mq 1,60

Wooden sliding door, with smooth, paneled movable leaf, natural oak; concealed sliding system on the frame

27 Wooden sliding door, with smooth, paneled movable leaf, natural oak;

C25038c concealed sliding system on the frame

- first floor, wc 1,00

TO SUM cad 1,00 viale Europa, 331 - 00144 Roma page 6

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

28 Interior, hollow wooden door covered with 10/10 stainless steel sheet metal C25029b with polished satin finish, rectangular, 6 mm glass porthole, partially etched, complete with handle to be selected from samples submitted, size 210 x 84

- first floor, swing door 1,00

TO SUM cad 1,00

29 Sliding panel 118x118 in tempered translucent 10 mm glass with concealed PA.06.01 external sliding mechanism and guides

- first floor, serving hatch 1,00

TO SUM cad 1,00

Partial Windows (Cat 6) euro

False ceiling (Cat 7)

False ceiling made with slabs of plasterboard 15 mm thick, including plastering of the joints

30 False ceiling made with slabs of plasterboard 15 mm thick, including B55004b plastering of the joints

- second floor, false ceiling 12,50

- second floor, air shaft *(eq. parts=,8*2,8) 2,24

- second floor mezzanine, air shaft *(eq. parts=1*2,8) 2,80

- first floor 26,00

- first floor mezzanine, toscana suite 39,00

TO SUM mq 82,54

Extra cost false ceiling for making straight plenums to connect the various heights

31 Extra cost false ceiling for making straight plenums to connect the various B55058a heights

- first floor 51,00

TO SUM m 51,00

False ceiling made of mineral fiber panels, thickness 15 ÷ 22 mm, fire reaction classe A2 - s1, d0, REI 180, on zinc-plated steel structure, panels 600 x 600 mm

32 False ceiling made of mineral fiber panels, thickness 15 ÷ 22 mm, fire B55045b reaction classe A2 - s1, d0, REI 180, on zinc-plated steel structure, panels

600 x 600 mm

- first floor 15,50

- first floor, mezzanine, wc 6,00

TO SUM mq 21,50

Partial False ceiling (Cat 7) euro

Painting operations (Cat 8)

Scraping old lime-based, distemper or washable paintwork, from walls and ceilings

33 Scraping old lime-based, distemper or washable paintwork, from walls and A25092 ceilings

- first floor, on existing walls 144,20

- first floor mezzanine, on existing walls *(eq. parts=(11,25*0,55)+(42,55* 2,8)) 125,33

T O C A R R Y - O V E R 269,53 viale Europa, 331 - 00144 Roma page 7

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R 269,53

TO SUM mq 269,53

Scarping old plastering, including sand-papering

34 Scarping old plastering, including sand-papering B65003 - first floor, on existing walls, h=1,40 55,60

- first floor mezzanine, on existing walls wc, h=0,55 *(eq. parts=5,0*0,55) 2,75

- first floor mezzanine, on existing walls Toscana suite, h=2,80 125,33

TO SUM mq 183,68

Smoothing partitions made of cellular concrete and false ceiling in plasterboard, thickness 3 mm

35 Smoothing partitions made of cellular concrete and false ceiling in A75041 plasterboard, thickness 3 mm second floor

- false ceiling 12,50

- air shaft 2,24

Partial mq 14,74 second floor mezzanine

- air shaft 2,80

Partial mq 2,80 first floor

- new partitions, h=3,70 80,50

- plasterboard *(eq. parts=26+5) 31,00

Partial mq 111,50 first floor mezzanine

- plasterboard 39,00

Partial mq 39,00

TO SUM mq 168,04

Preparation of the base of the internal masonry surfaces with a brush and application of water-based acrylic insulator

36 Preparation of the base of the internal masonry surfaces with a brush and B65001 application of water-based acrylic insulator

- second floor, air shaft 2,24

- seconf floor mezzanine, air shaft 2,80

- first floor, sup. vertical, h=1,40 *(eq. parts=55,6+(21,75*1,4)) 86,05

- first floor mezzanine, sup. vertical, h=0,55 2,75

- first floor mezzanine, sup. vertical, h=2,80 125,73

TO SUM mq 219,57

Two coats of distemper paint for internal surfaces

37 Two coats of distemper paint for internal surfaces B65009a - second floor, horizontal 12,50

- first floor, sup. horizontal *(eq. parts=47,00+(51,0*0,20)) 57,20 First floor mezzanine

- sup. vertical, h=0,55 2,75

- plasterboard 39,00

TO SUM mq 111,45

Extra cost for painting with distemper for each additional coat

38 Extra cost for painting with distemper for each additional coat B65009b - second floor 12,50

- first floor 57,20

- first floor mezzanine 41,75

T O C A R R Y - O V E R 111,45 viale Europa, 331 - 00144 Roma page 8

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R 111,45

TO SUM mq 111,45

Painting with three coats of transpiring water-based paint on internal surfaces

39 Painting with three coats of transpiring water-based paint on internal surfaces B65010a - second floor, air shaft 2,24

- second floor mezzanine, air shaft 2,80

Partial mq 5,04 first floor

- old sup. vertical, h=1,40 55,60

- new sup. vertical, h=1,40 30,45

Partial mq 86,05

- first floor mezzanine, sup. vertical, h=2,80 125,73

Partial mq 125,73

TO SUM mq 216,82

Partial Painting operations (Cat 8) euro

Bathroom fixture, Faucets (Cat 9)

Toilet bowl in white enamelled porcelain measuring approx. 360x550x380 mm, including masonry work

40 Toilet bowl in white enamelled porcelain measuring approx. 360x550x380 E02.02.020.a mm, including masonry work

- first floor 1,00

- first floor mezzanine 1,00

TO SUM cad 2,00

Plastic seat for toilet, heavy duty

41 Plastic seat for toilet, heavy duty E02.02.024.a - first floor 1,00

- first floor mezzanine 1,00

TO SUM cad 2,00

Washbasin in white enamelled porcelain measuring approx. 400x500 mm circa, installed on supporting shelves, including faucets to be selected from samples submitted, hook-up to plumbing and drainage networks

42 Washbasin in white enamelled porcelain measuring approx. 400x500 mm E02.02.030.a circa, installed on supporting shelves, including faucets to be selected from samples submitted, hook-up to plumbing and drainage networks

- first floor 1,00

- first floor mezzanine 1,00

TO SUM cad 2,00

Sink in white enamelled porcelain measuring approx. 550x550 mm, installed on supporting shelves, including faucets to be selected from samples submitted, hook-up to plumbing and drainage networks

43 Sink in white enamelled porcelain measuring approx. 550x550 mm, installed E02.02.030.a on supporting shelves, including faucets to be selected from samples submitted, hook-up to plumbing and drainage networks

- first floor, wc ante chamber 1,00

TO SUM cad 1,00

Partial Bathroom fixture, Faucets (Cat 9) euro viale Europa, 331 - 00144 Roma page 9

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

Electrical appliance (Cat 10)

GICO FG7N708AE Electric fryer on neutral cupboard LT. 8+8 Compact, self-supporting steel structure AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60 mm, two 8 lt pressed steel sinks, 1" drain and basin with filter to collect oil and two baskets included. Reinforced resistor unit, immersion and retractable, rotation 2x6,0 kW. Adjustable temperature 100-180 °C. Safety thermostat. IPX5 degree of water protection. Net measurements 400x700x900 mm.

44 GICO FG7N708AE Electric fryer on neutral cupboard LT. 8+8 Compact, self- PA.10.01 supporting steel structure AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60 mm, two 8 lt pressed steel sinks, 1" drain and basin with filter to collect oil and two baskets included. Reinforced resistor unit, immersion and retractable, rotation 2x6,0 kW. Adjustable temperature 100- 180 °C. Safety thermostat. IPX5 degree of water protection. Net measurements 400x700x900 mm.

1,00

TO SUM cad 1,00

GICO 8CG7N162FG Gas stove 6 burners on XL gas oven. Self-supporting steel structure AISI 304, "Scotch Brite", finish, AISI 304 steel counter 12/10 h=60 mm. Nozzles according to the type of gas required and set interchangeable for another type of gas. Rapid type burners in cast iron with brass burner cap, high output with minimum consumption and the lowest CO2 emissions, burners 3x5 kW and 3x4 kW. Gas oven in AISI 430 steel, insulated with ceramic fiber, oven capacity 910x710x280 mm. multi-gas burner 1x9,8 kW. Adjustable temperature 130-300°C. Piezo method for switching on. Furnished with grille. Net measurements 1200x700x900 mm, including 390x290 mm ribbed plate and 390x290 mm smooth plate

45 GICO 8CG7N162FG Gas stove 6 burners on XL gas oven. Self-supporting PA.10.03 steel structure AISI 304, "Scotch Brite", finish, AISI 304 steel counter 12/10 h=60 mm. Nozzles according to the type of gas required and set interchangeable for another type of gas. Rapid type burners in cast iron with brass burner cap, high output with minimum consumption and the lowest CO2 emissions, burners 3x5 kW and 3x4 kW. Gas oven in AISI 430 steel, insulated with ceramic fiber, oven capacity 910x710x280 mm. multi-gas burner 1x9,8 kW. Adjustable temperature 130-300°C. Piezo method for switching on. Furnished with grille. Net measurements 1200x700x900 mm, including 390x290 mm ribbed plate and 390x290 mm smooth plate

1,00

TO SUM cad 1,00

GICO 8CP7N755A Electric pasta cooker on neutral cupboard lt. 26. Self-supporting steel structure AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60 mm. 26 lt pressed tub in steel AISI 316 thickness 15/10. Integrated overflow and hook up to drain. Water tap with full opening at 1/4 turn. Cold water R 1/2" 0 bar 0 bar 0 GPL 0.Drain Ø50. Net measurements 400x700x900 mm. Including n°2 wire baskets in stainless steel AISI 304 with athermal handles, net measurements 290x145x215 mm.

46 GICO 8CP7N755A Electric pasta cooker on neutral cupboard lt. 26. Self- PA.10.04 supporting steel structure AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60 mm. 26 lt pressed tub in steel AISI 316 thickness 15/10.

Integrated overflow and hook up to drain. Water tap with full opening at 1/4 turn. Cold water R 1/2" 0 bar 0 bar 0 GPL 0.

Drain Ø50. Net measurements 400x700x900 mm. Including n°2 wire baskets in stainless steel AISI 304 with athermal handles, net measurements 290x145x215 mm.

1,00

TO SUM cad 1,00

Wall mounted hood. Net measurements 2800x900x500 mm.

47 Wall mounted hood. Net measurements 2800x900x500 mm.

PA.10.06 1,00

TO SUM cad 1,00

Convection oven GLOBE 8FMDE061AN EASY MISTO ELECTRIC 6+1GN1/1. External cladding and cooking chamber in steel AISI 304 thickness 10/10. Low voltage hologen inside lighting. Degree of protection IPX5. High power heat exchanger in chamber. Safety thermostats with relative alarms. Cooking method CONVEZIONE 5°-270°. Softened cold water R 1/2" 0 bar 0 bar 0 GPL 0. Drain Ø50. Electricity kW 11 V 0 A 50 Hz, including wall mounted steel hood 90x100, net measurements 895x827x974

48 Convection oven GLOBE 8FMDE061AN EASY MISTO ELECTRIC 6+ PA.10.07 1GN1/1. External cladding and cooking chamber in steel AISI 304 thickness

10/10. Low voltage hologen inside lighting. Degree of protection IPX5. High power heat exchanger in chamber. Safety thermostats with relative alarms.

Cooking method CONVEZIONE 5°-270°. Softened cold water R 1/2" 0 bar 0 bar 0 GPL 0. Drain Ø50. Electricity kW 11 V 0 A 50 Hz, including wall mounted steel hood 90x100, net measurements 895x827x974

1,00

TO SUM cad 1,00 viale Europa, 331 - 00144 Roma page 10

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

Table with double fridge GICO 8TRB182A, -2°C +7°C, furnished with three doors. Entrance and outlet cooling liquid. Electricity 0,34 kW 230 V 0 A 50 Hz. Net measurements 1820x700x940 mm.

49 Table with double fridge GICO 8TRB182A, -2°C +7°C, furnished with three PA.10.08 doors. Entrance and outlet cooling liquid. Electricity 0,34 kW 230 V 0 A 50

Hz. Net measurements 1820x700x940 mm.

1,00

TO SUM cad 1,00

Scrubber with 5 trays GN1/1, GICO 8AB05A furnished with support. Electricity 0,45kW 230V 0A 50Hz. Net measurements 760x700x850 mm.

50 Scrubber with 5 trays GN1/1, GICO 8AB05A furnished with support.

PA.10.09 Electricity 0,45kW 230V 0A 50Hz. Net measurements 760x700x850 mm.

1,00

TO SUM cad 1,00

Fridge cabinet lt 700, GICO 8AF701M 1 door and 1 cell, -2°C +7°C. Electricity 0,36 kW 230 V 0 A 50 Hz. Net measurements 733x803x2090 mm.

51 Fridge cabinet lt 700, GICO 8AF701M 1 door and 1 cell, -2°C +7°C.

PA.10.09 Electricity 0,36 kW 230 V 0 A 50 Hz. Net measurements 733x803x2090 mm.

1,00

TO SUM cad 1,00

Fridge cabinet GICO 8AF701B lt 700, 1 door and 1 cell, -20°C -15°C. Electricity 0,59 kW 230 V 0 A 50 Hz. Net measurements 733x803x2090 mm.

52 Fridge cabinet GICO 8AF701B lt 700, 1 door and 1 cell, -20°C -15°C.

PA.10.10 Electricity 0,59 kW 230 V 0 A 50 Hz. Net measurements 733x803x2090 mm.

1,00

TO SUM cad 1,00

Hot cupboard with through doors, GICO 8TAN149 electricity 2kW 230V 0A 50Hz, net measurements 1400x700x900 mm

53 Hot cupboard with through doors, GICO 8TAN149 electricity 2kW 230V 0A PA.10.12 50Hz, net measurements 1400x700x900 mm

1,00

TO SUM cad 1,00

Dishwasher 852/305 with digital controls for basket 50x50 cm. Cold and hot water R 1/2". Drain Ø50. Electricity 6,2kW 400V A 50Hz. Net measurements 600x620x1325 mm.

54 Dishwasher 852/305 with digital controls for basket 50x50 cm. Cold and hot PA.10.14 water R 1/2". Drain Ø50. Electricity 6,2kW 400V A 50Hz. Net measurements

600x620x1325 mm.

1,00

TO SUM cad 1,00

Table fridge GICO 8TRB182Awith condenser unit incorporated, three doors, counter with 4cm back splash, temperature -2°C +7°C, with entrance and outlet cooling liquid, electricity 0,34kW 230V 0A 50Hznet dim. 1820x700x940 mm

55 Table fridge GICO 8TRB182Awith condenser unit incorporated, three doors, PA.10.21 counter with 4cm back splash, temperature -2°C +7°C, with entrance and outlet cooling liquid, electricity 0,34kW 230V 0A 50Hz net dim. 1820x700x940 mm

1,00

TO SUM cad 1,00

Fridge cupboard for wine with one door, mod. ENOPRESTIGE 4004TV, electricity 0,40kW 230V 0A 50Hz, net measurements 833x470x1920

56 Fridge cupboard for wine with one door, mod. ENOPRESTIGE 4004TV, PA.10.28 electricity 0,40kW 230V 0A 50Hz, net measurements 833x470x1920

1,00

TO SUM cad 1,00

57 Microwave oven PANASONIC NE1037 digital. Microwave propagation viale Europa, 331 - 00144 Roma page 11

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

PA.10.29 system, from the bottom upwards. Timer 99 minutes for 10 fixed automatic programs with a call of up to 20 different programs External cladding and cooking chamber in stainless steel. Cooking plate ceramic hob. Electricity 1400kW 230V 0A 50Hz. Net measurements 510x360x745 mm.

1,00

TO SUM cad 1,00

Partial Electrical appliance (Cat 10) euro

Furniture and accessories (Cat 11)

GICO 8PL7N070CSC Neutral element without drawers in steel AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60 mm, with steel-coated door and fitted with steel handle. Net measurements 400x700x900 mm

58 GICO 8PL7N070CSC Neutral element without drawers in steel AISI 304, PA.11.02 "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60 mm, with steel-coated door and fitted with steel handle. Net measurements 400x700x900 mm

1,00

TO SUM cad 1,00

GICO 8PL7N070C Neutral element with drawer on open cupboard in steel AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60mm, net measurements 400x700x900

59 GICO 8PL7N070C Neutral element with drawer on open cupboard in steel PA.11.05 AISI 304, "Scotch Brite" finish, AISI 304 steel counter 12/10 h=60mm, net measurements 400x700x900 1,00

TO SUM cad 1,00

GICO serie Neutral 470 Work table in stainless steel with drawers, net measurements 600x700x900 mm

60 GICO serie Neutral 470 Work table in stainless steel with drawers, net PA.11.10 measurements 600x700x900 mm

1,00

TO SUM cad 1,00

61 GICO serie Neutral 470 Neutral stainless steel cabinet with hinged door, net PA.11.11 measurements 500x700x2000 mm

1,00

TO SUM cad 1,00

GICO serie Neutral 470 Stainless steel superstructure with open counter, net measurements 1400x300x450

62 GICO serie Neutral 470 Stainless steel superstructure with open counter, net PA.11.13 measurements 1400x300x450

1,00

TO SUM cad 1,00

GICO serie Neutral 470 Table with back wash, pre-washing sink measuring 40x50 cm, drain Ø50, furnished with attachments for hot and cold water, net measurements 1400x710x860 mm

63 GICO serie Neutral 470 Table with back wash, pre-washing sink measuring PA.11.15 40x50 cm, drain Ø50, furnished with attachments for hot and cold water, net measurements 1400x710x860 mm 1,00

TO SUM cad 1,00 viale Europa, 331 - 00144 Roma page 12

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

Waste trolley without pedal GICO 8CRN5400 , lt 50, diameter 39,5 cm, net measurements 395x395x620

64 Waste trolley without pedal GICO 8CRN5400 , lt 50, diameter 39,5 cm, net PA.11.16 measurements 395x395x620

1,00

TO SUM cad 1,00

Wash basin on cabinet with sliding doors, GICO serie Neutral 470 counter with two bowls, fitted with drip tray, drain Ø50, furnished with attachments for hot and cold water, net measurements 1400x600x900 mm

65 Wash basin on cabinet with sliding doors, GICO serie Neutral 470 counter PA.11.17 with two bowls, fitted with drip tray, drain Ø50, furnished with attachments for hot and cold water, net measurements 1400x600x900 mm 1,00

TO SUM cad 1,00

66 Neutral steel cabinet with hinged door and back splash, GICO serie Neutral PA.11.18 470 net measurements 700x600x900 mm

1,00

TO SUM cad 1,00

Wall mounted cabinet with sliding doors, GICO serie Neutral 470 net measurements 1400x400x660 mm

67 Wall mounted cabinet with sliding doors, GICO serie Neutral 470 net PA.11.19 measurements 1400x400x660 mm

1,00

TO SUM cad 1,00

Wall mounted cabinet with sliding doors, GICO serie Neutral 470 net measurements 1000x400x660 mm

68 Wall mounted cabinet with sliding doors, GICO serie Neutral 470 net PA.11.20 measurements 1000x400x660 mm

1,00

TO SUM cad 1,00

Wall mounted cabinet with sliding doors,GICO serie Neutral 470 net measurements 1800x400x660 mm

69 Wall mounted cabinet with sliding doors,GICO serie Neutral 470 net PA.11.22 measurements 1800x400x660 mm

1,00

TO SUM cad 1,00

Storage cabinet with sliding doors and three adjustable shelves, GICO serie Neutral 470 net measurements 1000x500x2000 mm

70 Storage cabinet with sliding doors and three adjustable shelves, GICO serie PA.11.23 Neutral 470 net measurements 1000x500x2000 mm

1,00

TO SUM cad 1,00

Storage cabinet with sliding doors and three adjustable shelves, GICO serie Neutral 470 net measurements 1200x500x2000 mm

71 Storage cabinet with sliding doors and three adjustable shelves, GICO serie PA.11.24 Neutral 470 net measurements 1200x500x2000 mm

1,00

TO SUM cad 1,00

72 Shelf with 4 adjustable flat shelves , GICO serie Neutral 470 net size PA.11.25 1000x500x2000 mm

1,00

T O C A R R Y - O V E R 1,00 viale Europa, 331 - 00144 Roma page 13

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R 1,00

TO SUM cad 1,00

Partial Furniture and accessories (Cat 11) euro

Partial ARCHITECTURAL INTERVENTIONS (SpCat 1) euro viale Europa, 331 - 00144 Roma page 14

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

INTERVENTIONS OF STRUCTURAL CONSOLIDATION (SpCat 2) Consolidations (Cat 12)

73 Construction site installation and temporary works PA.12.00 - piano primo ammezzato 1,00

TO SUM a corpo 1,00

74 Dismantling of wood floor scaffolding, consisting of battens, joists and A3.01.7 planks, excluding the large bearing frame, including drop down and carriage to the constructions site depot.

- tra piano primo ammezzato e piano primo 47,60

TO SUM mq 47,60

75 Disassembly of the main structure consisting of wooden beams connected to PA.12.01 the load-bearing walls including drop down and carriage to the construction site depot.

- tra piano primo ammezzato e piano primo 1,00

TO SUM a corpo 1,00

76 Pick up and transport to landfills and / or authorized waste materials facilities A3.03.6 coming from demolitions, with truck loads up to 1.5t excluding costs of landfill

13,33

TO SUM t 13,33

77 As item A3.03.6 for each additional km to 10 km from the site A3.03.5.E 133,30

TO SUM t 133,30

78 Compensation to authorized disposal sites for injection of waste material A3.03.7.g coming from demolitions for inert waste

13,33

TO SUM t 13,33

79 Hydraulic telescopic crane, range capacity up to 32 meters, including the A4.01.22.a motorman and the fuel flow rate for each working day up to 30 tonnes.

1,00

TO SUM giorno 1,00

80 Composite slab made of wood, consisting of a primary and a secondary A7.01.13.a framework resting and arranged perpendicular to the main beam and of a plank made ??of boards of fir wood with a thickness of not less than 3 cm;

including slab of 4 cm in concrete C25/30 - Rck = 30 N / mm ² with welded mesh Ø 8 to 20x20 cm

47,60

TO SUM mq 47,60 viale Europa, 331 - 00144 Roma page 15

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

81 Higher charge for live load of 300 kg / sq m and laminated wood instead of PA.12.02 price list solid wood . NB the pice includes the lack of spending on the construction of the reinforced concrete slab included in the previous item but not included in the present work

47,60

TO SUM mq 47,60

82 Burden for the execution of slots in the walls and for the anchoring with PA.12.03 bricks and emaco. Burden for the repair of any openings deriving from the previously removed floor slab 1,00

TO SUM a corpo 1,00

83 Execution of white painted aluminum profile to frame the opening on the PA.12.04 bathroom partition where the laminated wood beam will be placed

1,00

TO SUM a corpo 1,00

84 Repositioning of the opening on kitchen load-bearing masonry, comprising PA.12.05 the props, the demolition of masonry and the construction of the support structure in metallic carpentry and the gap closing with existing bricks 1,00

TO SUM a corpo 1,00

Widening of the existing gap on the masonry bearing walls connecting the kitchen to the stairs and elevator comprising the props, the demolition of the existing masonry and lintel and the realization of the support structure in metallic carpentry and the restores

85 Widening of the existing gap on the masonry bearing walls connecting the PA.12.06 kitchen to the stairs and elevator comprising the props, the demolition of the existing masonry and lintel and the realization of the support structure in metallic carpentry and the restores

1,00

TO SUM a corpo 1,00

Partial Consolidations (Cat 12) euro

Partial INTERVENTIONS OF STRUCTURAL CONSOLIDATION (SpCat 2) euro viale Europa, 331 - 00144 Roma page 16

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

MECHANICAL SYSTEM (SpCat 3) Air-conditioning (Cat 13)

86 Outdoor unit for air conditioning system for environments to heat pump with M01 UE 10.f high efficiency , of the type with variable refrigerant volume , utilizing refrigerant gas R410a ecological , consisting of a joined ' external condensed in the air capable of powering up to a maximum of 6 units ' internal cooling through a single line with two tubes from which you derive the power to the units ' internal . The refrigerant circuit can have a maximum length of 120 m between outdoor unit and indoor unit furthest with a maximum height difference of 40 m .. Operation in heat pump mode with external temperatures down to -20 ° C. Capacity ratio in the connection between indoor and outdoor units equal to 130% (with any indoor unit used ) .

Compatible with control over the Internet. Performances refer to standard conditions ( 35 ° Cbs/24 Estate Te ° Cbu - Winter Te CBS 7 ° / 6 ° Cbu ) . PF cooling capacity (kW) . PT thermal power (kW) . Sound pressure level to the normal operation PS ( dB (A ) ) . Outdoor unit 4HP, PF=12,1, PT=12,5, EER 4,30, COP 4,62, dim.AxLXP 1330x940x340. PS=50/52. Power Supply 380 V.

1,00

TO SUM cad 1,00

Indoor unit cassette 4-way mini, semi-recessed dimensions 600x600 mm. Type with very low sound pressure with motor current (DC inverter) complete with condensate lift pump cant of 850 mm, and washable anti-mold filter supplied. PF cooling capacity (kW). PT thermal power (kW). Sound pressure level at the minimum, average, high-speed rotation PS (dB (A)). External dimensions (D) AxL (mm)PF=4,5 - PT=5,0 - PS=28/29/31 - D=625x625

87 Indoor unit cassette 4-way mini, semi-recessed dimensions 600x600 mm.

M02 UI 15.b Type with very low sound pressure with motor current (DC inverter) complete with condensate lift pump cant of 850 mm, and washable anti-mold filter supplied. PF cooling capacity (kW). PT thermal power (kW). Sound pressure level at the minimum, average, high-speed rotation PS (dB (A)). External dimensions (D) AxL (mm) PF=4,5 - PT=5,0 - PS=28/29/31 - D=625x625

3,00

TO SUM cad 3,00

Accessories for air conditioners to centralized distribution with two tubes consist of control panels, boards and / or devices to be added to the cost basis for the completion of the installation or additional functions.Wired remote control simplified

88 Accessories for air conditioners to centralized distribution with two tubes M02 UI 90.a consist of control panels, boards and / or devices to be added to the cost basis for the completion of the installation or additional functions.

Wired remote control simplified

3,00

TO SUM cad 3,00

As item M02 UI 90.a.Joint for pipes up to 2 indoor units to 22.4 kW

89 As item M02 UI 90.a.

M02 UI 90.i Joint for pipes up to 2 indoor units to 22.4 kW

2,00

TO SUM cad 2,00

First turning on and configuring VRF system by authorized personnelPanasonic

90 First turning on and configuring VRF system by authorized personnel M01 PA 90 Panasonic

1,00

TO SUM cad 1,00

Operations preparatory to functional testing of piping and commissioning of the system consisting of the circuit by pressing the nitrogen to 38 bar, running dry and adding refrigerant gas to compensate for the cooling lines.

91 Operations preparatory to functional testing of piping and commissioning of viale Europa, 331 - 00144 Roma page 17

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

M01 PA 91 the system consisting of the circuit by pressing the nitrogen to 38 bar, running dry and adding refrigerant gas to compensate for the cooling lines.

1,00

TO SUM cad 1,00

Connection of air conditioners with direct expansion of a condensing unit or a gas distribution network in a refrigerator (away from the joint junction) to a maximum length of 20 m, consisting of copper pipes of suitable diameter for the liquid phase and gas phase, girdles synthetic elastomer extruded insulation of adequate thickness with conductivity at 40 ° C not exceeding 0.042 W / mC and a factor of resistance to water vapor diffusion> 1600 condensate drain pipe conveyed to the drain pipe or to the terrace, plastic sheath for passing power and cables from the unit or condensing unit from the electrical area. The connection is inclusive of fittings, flanges, welding, jointing material. Are excluded: the main gas distribution network refrigerator; the branching joint; the network main discharge of condensate discharge.For each connection with a cooling capacity of up to 4.5 kW.

92 Connection of air conditioners with direct expansion of a condensing unit or a

13.30.230.1 gas distribution network in a refrigerator (away from the joint junction) to a maximum length of 20 m, consisting of copper pipes of suitable diameter for the liquid phase and gas phase, girdles synthetic elastomer extruded insulation of adequate thickness with conductivity at 40 ° C not exceeding

0.042 W / mC and a factor of resistance to water vapor diffusion> 1600 condensate drain pipe conveyed to the drain pipe or to the terrace, plastic sheath for passing power and cables from the unit or condensing unit from the electrical area. The connection is inclusive of fittings, flanges, welding, jointing material. Are excluded: the main gas distribution network refrigerator;

the branching joint; the network main discharge of condensate discharge.

For each connection with a cooling capacity of up to 4.5 kW.

3,00

TO SUM cad 3,00

Copper pipes for refrigerant gas supplied in rolls up to a diameter 22 x 1.0 and bars for greater thicknesses and diameters, calculated per linear meter coated with insulating sheath in synthetic elastomer extruded closed cell foam with a coefficient of thermal conductivity at 40 C is not greater than 0.040 W / mC and resistance factor to water vapor diffusion> 5000, with welding fittings type folder. The cost of the pipe per meter includes the supply and installation of up to an altitude of 4.0 m with respect to the support surface, the insulation, the trims, the material for joints and fixtures. Excludes masonry opening tracks on hollow bricks and masonry read and fixing the pipes within tracks, the closing tracks, plaster, painting. Outer diameter to thickness of the copper tube: D xs (mm).Copper pipes for refrigerant gas supplied in rolls up to a diameter 22 x 1.0 and bars for greater thicknesses and diameters, calculated per linear meter coated with insulating sheath in synthetic elastomer extruded closed cell foam with a coefficient of thermal conductivity at 40 C is not greater than 0.040 W / mC and resistance factor to water vapor diffusion> 5000, with welding fittings type folder. The cost of the pipe per meter includes the supply and installation of up to an altitude of 4.0 m with respect to the support surface, the insulation, the trims, the material for joints and fixtures. Excludes masonry opening tracks on hollow bricks and masonry read and fixing the pipes within tracks, the closing tracks, plaster, painting. Outer diameter to thickness of the copper tube: D xs (mm).

93 Copper pipes for refrigerant gas supplied in rolls up to a diameter 22 x 1.0

13.15.180.2 and bars for greater thicknesses and diameters, calculated per linear meter coated with insulating sheath in synthetic elastomer extruded closed cell foam with a coefficient of thermal conductivity at 40 C is not greater than

0.040 W / mC and resistance factor to water vapor diffusion> 5000, with welding fittings type folder. The cost of the pipe per meter includes the supply and installation of up to an altitude of 4.0 m with respect to the support surface, the insulation, the trims, the material for joints and fixtures. Excludes masonry opening tracks on hollow bricks and masonry read and fixing the pipes within tracks, the closing tracks, plaster, painting. Outer diameter to thickness of the copper tube: D xs (mm).

Copper pipes for refrigerant gas supplied in rolls up to a diameter 22 x 1.0 and bars for greater thicknesses and diameters, calculated per linear meter coated with insulating sheath in synthetic elastomer extruded closed cell foam with a coefficient of thermal conductivity at 40 C is not greater than

0.040 W / mC and resistance factor to water vapor diffusion> 5000, with welding fittings type folder. The cost of the pipe per meter includes the supply and installation of up to an altitude of 4.0 m with respect to the support surface, the insulation, the trims, the material for joints and fixtures. Excludes masonry opening tracks on hollow bricks and masonry read and fixing the pipes within tracks, the closing tracks, plaster, painting. Outer diameter to thickness of the copper tube: D xs (mm).

30,00

TO SUM m 30,00

As item 13.15.180.4.D x s = 15,9 x 1,0 - S = 7 (tube in rolls).

94 As item 13.15.180.4.

13.15.180.4 D x s = 15,9 x 1,0 - S = 7 (tube in rolls).

30,00

TO SUM m 30,00

Support brackets for pipes to be carried out in various sections of iron, suitably shaped, welded and bolted, to be counted in pounds, including fixing materials, masonry, painting with two coats of primer or galvanizing.Brackets in galvanized steel.

95 Support brackets for pipes to be carried out in various sections of iron,

13.15.130.2 suitably shaped, welded and bolted, to be counted in pounds, including fixing materials, masonry, painting with two coats of primer or galvanizing.

viale Europa, 331 - 00144 Roma page 18

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

Brackets in galvanized steel.

5,00

TO SUM kg 5,00

Polyethylene insulated conductors twisted single pair with overall shield Bedfoil ® aluminum / polyester ideal for control applications, and computer equipment. Line communication bus. (Twisted pair cable Belden). And 'including the installation in pipes or view recessed, channel, or stapled on the catwalk. It 'also included more than is necessary to give the finished work. Included are the conduits, junction boxes and masonry.2 couples

96 Polyethylene insulated conductors twisted single pair with overall shield M01 CV 40.a Bedfoil ® aluminum / polyester ideal for control applications, and computer equipment. Line communication bus. (Twisted pair cable Belden). And 'including the installation in pipes or view recessed, channel, or stapled on the catwalk. It 'also included more than is necessary to give the finished work. Included are the conduits, junction boxes and masonry.

2 couples

40,00

TO SUM m 40,00

Pipes, rigid PVC, UNI 10972 standard series, for downspouts, vents and cold-water discharges, cutlery with brackets vertically or horizontally within the building, with glued joints or gasket, supplied and laid. This includes: the special pieces; the fixtures; masonry opening tracks on hollow bricks and masonry read; the fixing of the pipes. And 'what should be included to give the piping complete. Outer diameter x thickness: D x s (mm).D x s = 32 x 1,2.

97 Pipes, rigid PVC, UNI 10972 standard series, for downspouts, vents and

8.2.70.1 cold-water discharges, cutlery with brackets vertically or horizontally within the building, with glued joints or gasket, supplied and laid. This includes: the special pieces; the fixtures; masonry opening tracks on hollow bricks and masonry read; the fixing of the pipes. And 'what should be included to give the piping complete.

Outer diameter x thickness: D x s (mm).

D x s = 32 x 1,2.

5,00

TO SUM m 5,00

Painting of radiator elements, after cleaning with steel brush, followed by a coat of rust inhibitor, a cementite and a glaze. And 'what should be included to give the finished work. For radiator element.Hand with brush, mounted on radiators, to clean and paint removal.

98 Painting of radiator elements, after cleaning with steel brush, followed by a

12.3.50.1 coat of rust inhibitor, a cementite and a glaze. And 'what should be included to give the finished work. For radiator element.

Hand with brush, mounted on radiators, to clean and paint removal.

29,00

TO SUM cad 29,00

Pair of chrome plated brass valves for heating body consisting of the holder and angle valve with thermostatic head, complete with fittings for connection to iron pipe, copper or plastic plates and wall cover.Nominal size 15 (1/2 ") with normal head.

99 Pair of chrome plated brass valves for heating body consisting of the holder

13.18.260.2 and angle valve with thermostatic head, complete with fittings for connection to iron pipe, copper or plastic plates and wall cover.

Nominal size 15 (1/2 ") with normal head.

2,00

TO SUM cad 2,00

Connection of the radiator or radiator (cast iron, aluminum or steel) from the distribution manifold or from the main distribution network, consisting of a pair of chrome-plated brass valves (holder and angle valve with knob), manual air vent valve Brass chrome, copper pipes, iron or plywood of suitable diameter coated with insulating sheath thickness and conductivity such that the current law, with thickness reduction of 30% for installation in heated rooms, including fittings, accessories required for the installation and masonry opening tracks on hollow bricks and masonry read and fastening the tubes with the exception of traces of slabs, concrete walls or stone and painting. Also excluded are the distribution manifold and the core network.For connection

100 Connection of the radiator or radiator (cast iron, aluminum or steel) from the

13.3.130.1 distribution manifold or from the main distribution network, consisting of a pair of chrome-plated brass valves (holder and angle valve with knob), manual air vent valve Brass chrome, copper pipes, iron or plywood of suitable diameter coated with insulating sheath thickness and conductivity such that the current law, with thickness reduction of 30% for installation in heated rooms, including fittings, accessories required for the installation and masonry opening tracks on hollow bricks and masonry read and fastening the tubes with the exception of traces of slabs, concrete walls or stone and painting. Also excluded are the distribution manifold and the core network.

For connection

1,00 viale Europa, 331 - 00144 Roma page 19

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R 1,00

TO SUM cad 1,00

As item 13.3.130.1.Surcharge for thermostatic valve.

101 As item 13.3.130.1.

13.3.130.2 Surcharge for thermostatic valve.

1,00

TO SUM cad 1,00

Decommissioning and disposal of technology equipment consisting ofmechanical parts of plants positioned within premises, including the removal of the same, the transport on public roads, the load on suitable vehicles and transportation to final approved landfill, all in full compliance with the current regulations for disposal. This includes the cleaning of the rooms or areas in which they were placed components. Remain on, the rental costs for special equipment necessary to transport the public street and the costs of disposal that must be delivered to Companies authorized.Equipment of the air conditioning

102 Decommissioning and disposal of technology equipment consisting of M01 90 SM.a mechanical parts of plants positioned within premises, including the removal of the same, the transport on public roads, the load on suitable vehicles and transportation to final approved landfill, all in full compliance with the current regulations for disposal. This includes the cleaning of the rooms or areas in which they were placed components. Remain on, the rental costs for special equipment necessary to transport the public street and the costs of disposal that must be delivered to Companies authorized.

Equipment of the air conditioning

1,00

TO SUM cad 1,00

Partial Air-conditioning (Cat 13) euro

Air extraction system (Cat 14)

Fan dropside consists of self-supporting galvanized steel frame with removable panels, double inlet centrifugal fan isolated from the structure with built-in motor, directly coupled, single-phase air flow rates up to 5,000 m³ / h. Suitable for high temperatures. Excludes masonry and wiring. Airflow max: Q (m³ / h). Prevalence corresponding not less than: H (mbar). Power Consumption: P (W).. Q = 4500 H = 3,0 P = 1500.

103 Fan dropside consists of self-supporting galvanized steel frame with

13.23.81.7 removable panels, double inlet centrifugal fan isolated from the structure with built-in motor, directly coupled, single-phase air flow rates up to 5,000 m³ / h.

Suitable for high temperatures. Excludes masonry and wiring. Airflow max: Q (m³ / h). Prevalence corresponding not less than: H (mbar). Power Consumption: P (W)..

Q = 4500 H = 3,0 P = 1500.

1,00

TO SUM cad 1,00

Accessories for ventilating boxes consist of speed regulators, pressure relief dampers, silencers, flexible joints. Does not include wiring.Flexible coupling canvas W x H = 400 x 200 mm.

104 Accessories for ventilating boxes consist of speed regulators, pressure relief

13.23.90.17 dampers, silencers, flexible joints. Does not include wiring.

Flexible coupling canvas W x H = 400 x 200 mm.

1,00

TO SUM cad 1,00

Small centrifugal fan in line for flow rates up to 1700 m³ / h, single phase motor, suitable for direct mounting on circular channels. Excludes masonry and wiring. Airflow med / max: Q (m³ / h). Prevalence corresponding not less than: H (mbar). Diameter of duct connection: D (mm). Power Consumption: P (W).Q = 110/220 H = 0,9/0,2 D = 125 P = 30.

105 Small centrifugal fan in line for flow rates up to 1700 m³ / h, single phase

13.23.60.2 motor, suitable for direct mounting on circular channels. Excludes masonry and wiring. Airflow med / max: Q (m³ / h). Prevalence corresponding not less than: H (mbar). Diameter of duct connection: D (mm). Power Consumption: P (W).

Q = 110/220 H = 0,9/0,2 D = 125 P = 30.

1,00

TO SUM cad 1,00 viale Europa, 331 - 00144 Roma page 20

Ord.Num.

C O S T S

TARIFF

WORK DESIGNATION Quantity unit TOTAL

C A R R Y - O V E R

Accessories for centrifugal fans for direct mounting on circular channels. Does not include wiring.Regulator 5-speed up to 240 W.

106 Accessories for centrifugal fans for direct mounting on circular channels.

13.23.70.1 Does not include wiring.

Regulator 5-speed up to 240 W.

1,00

TO SUM cad 1,00

Ducts for air distribution in rectangular or circular section made of galvanized steel with flange joints, including special parts, gaskets, nuts and bolts. Minimum thickness of the sheet 6/10 mm for measurements of max side up to 500 mm, 8/10 mm for measurements from 501 mm to 1000 mm, 10/10 mm to 1001 mm and measures. The channeling and 'counted per kg.For quantities up to the early 1000 Kg.

107 Ducts for air distribution in rectangular or circular section made of galvanized

13.24.50.1 steel with flange joints, including special parts, gaskets, nuts and bolts.

Minimum thickness of the sheet 6/10 mm for measurements of max side up to 500 mm, 8/10 mm for measurements from 501 mm to 1000 mm, 10/10 mm to 1001 mm and measures. The channeling and 'counted per kg.

For quantities up to the early 1000 Kg.

140,00

TO SUM kg 140,00

Ducts for air distribution in rectangular or circular section made of stainless steel AISI 304 or 316 with flange joints, including special parts, gaskets, nuts and bolts. Minimum thickness of the sheet 6/10 mm for measurements of max side up to 500 mm, 8/10 mm for measurements from 501 mm to 1000 mm, 10/10 mm to 1001 mm and measures. The channeling and 'counted per kg.For quantities up to the early 1000 Kg.

108 Ducts for air distribution in rectangular or circular section made of stainless

13.24.52.1 steel AISI 304 or 316 with flange joints, including special parts, gaskets, nuts and bolts. Minimum thickness of the sheet 6/10 mm for measurements of max side up to 500 mm, 8/10 mm for measurements from 501 mm to 1000 mm, 10/10 mm to 1001 mm and measures. The channeling and 'counted per kg.

For quantities up to the early 1000 Kg.

22,00

TO SUM kg 22,00

Support brackets for pipes to be carried out in various sections of iron, suitably shaped, welded and bolted, to be counted in pounds, including fixing materials, masonry, painting with two coats of primer or galvanizing.Brackets in galvanized steel.

109 Support brackets for pipes to be carried out in various sections of iron,

13.15.130.2 suitably shaped, welded and bolted, to be counted in pounds, including fixing materials, masonry, painting with two coats of primer or galvanizing.

Brackets in galvanized steel.

10,00

TO SUM kg 10,00

Damper blade circular blade unique galvanized steel pins passing on Teflon bushings, length 300 mm up to 300 mm diameter, 400 mm length for larger diameters, stick straight up to diameter 700, flanged for larger diameters.Diameter = 150 L = 300.

110 Damper blade circular blade unique galvanized steel pins passing on Teflon

13.24.410.3 bushings, length 300 mm up to 300 mm diameter, 400 mm length for larger diameters, stick straight up to diameter 700, flanged for larger diameters.

Diameter = 150 L = 300.

1,00

TO SUM…