SATPC0038212 Tab 04 4 SOW Rev.pdf

PDF 248 KB Posted

Attached to
Wolfspeed 300 kW 3-phase power inverters
Solicitation number
80NSSC25901561Q
Issued by

About this file

This Statement of Work (SOW) details the procurement of four Wolfspeed 300 kW 3-Phase Power Inverters for the Hybrid Propulsion Emulation Rig (HyPER) at NASA's Glenn Research Center. The inverters will be used in electrified aircraft propulsion research, converting DC power to 3-phase AC power for electric motor simulation of gas turbine engine spool shafts.

The technical specifications require inverters with an 800VDC bus nominal (900V max), 360ARMS output, 80kHz maximum switching frequency, 300uF DC Link Capacitance, and a liquid-cooled cold plate with CAN Interface. The specific model is Wolfspeed, Inc. / CRD300DA12EXM3. The procurement has a lead time of 2 weeks, with delivery required no later than May 16th, 2025. This solicitation is set aside for small businesses, and vendors must be authorized Wolfspeed resellers, with a signed letter of authorization required for quote submission.

View the file

Other files

File Type Posted
SATPC0038212 Tab 10 RFQ Open Market.pdf PDF
SATPC0038212 Tab 06 BNJ_CO_Redacted.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

Brand WolfSpeed 300 kW 3-Phase Power Inverter - Quantity 4

Description:

The Hybrid Propulsion Emulation Rig (HyPER) is a test bed facility at the Glenn Research Center for conducting electrified aircraft propulsion research. The test bed utilizes electric motors to simulate the high and low pressure spool shafts of a gas turbine engine; electric motors are coupled to each of the simulation motors to permit the addition or extraction of energy from the motor shafts. Power inverters are required to convert DC power into 3-phase AC power as a supply to each motor. They also determine how that power is fed into the motor which ultimately impacts its operational characteristics.

Lead Time: 2 Weeks; required no later than May 16th, 2025

Specifications:

The primary specifications for the power inverter are:

• 800VDC bus nominal (900V max)

• 360ARMS output

• 80kHz maximum switching frequency

• 300uF DC Link Capacitance

• Liquid cooled cold plate

• CAN Interface

• Wolfspeed, Inc. / CRD300DA12E-

XM3

lquave Highlight

Description:
Specifications:

File details come from the government source that posted it. Updated .