This document is a Statement of Work (SOW) for partial discharge testing of coupon samples of electrically insulating materials and coatings created at the NASA Glenn Research Center. The objective is to determine the partial discharge inception voltage (PDIV) for these samples, which is critical knowledge for applications such as electric aircraft propulsion.
The SOW specifies that the testing should be conducted using a cylinder-plain configured electrode setup with a 60Hz signal. Two sets of samples are required: Set 1 consists of thermally aged polymer samples approximately 250mm x 500mm and 0.2-0.3mm thick, with 3-4 samples and 5-6 repeats per sample (total of 20); Set 2 consists of ceramic coated metal substrate samples approximately 750mm x 750mm and 0.150-0.500mm thick, with 3-4 samples and 5-6 repeats per sample (total of 20). The output shall be a final report including the PDIV values and patterns.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SATPC0035346 Tab 10 RFQ Open Market (FULL AND OPEN).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Partial discharge testing statement of work
This request is to procure partial discharge testing for coupon samples of electrically insulating materials and coatings created at the NASA Glenn research center. Partial discharge testing determines the partial discharge inception voltage (PDIV) for electrically insulating samples. Knowledge of this material characteristic is particularly critical for applications like electric aircraft propulsion, where knowledge of this characteristic can determine the applicability of a material to an application.
Specifics of the testing:
• PDIV values due to surface discharges are desired as are characteristics of up to 1.5 X PDIV (if possible)
• Testing should be done with a cylinder-plain configured electrodes., utilizing a 60Hz signal
• A final report including PDIV values and patterns will the output
Sample sets
• Set 1: Thermally aged polymer samples o ~250mmx500mm, 0.2-0.3mm thick o 3-4 samples with 5-6 repeats of each sample (total of 20),
• Set 2: Ceramic coated on a metal substrate o ~750 mm x 750 mm, 0.150-0.500 mm thick.
o 3-4 samples with 5-6 repeats of each sample. (total of 20)