Salient Characteristics.docx

DOCX document 23 KB Posted

Attached to
FLIR Teledyne RS6780 OR EQUAL Mid Wave IR Camera System Federal contract opportunity
Solicitation number
FA461022Q0031
Issued by
Department of the Air Force Space Command

About this file

This solicitation requests quotes for four FLIR Teledyne RS6780 mid-wave infrared camera systems or equal. Offerors must utilize the attached SF1449 solicitation document to submit fixed price quotes by June 14, 2022. Questions are due by this date as well, with responses to be posted on or around June 16, 2022. The solicitation is set aside for small businesses and prepared according to FAR Parts 12, 13.5, and 19.5. The Department of the Air Force Space Command is listed as the issuing agency. The solicitation includes specifications for the camera systems and notes that funding is not presently available, with no award to be made until funds are allocated.

View the file

Other files for this federal contract opportunity

Other files attached to FLIR Teledyne RS6780 OR EQUAL Mid Wave IR Camera System, newest first.
File Type Posted
Solicitation Amendment - FA461022Q00310001.pdf PDF
Salient Characteristics_Rev1_20220602.docx DOCX document
Solicitation - FA461022Q0031.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS

The below characteristics are specific to the lens requirements for mission support. Though some of these requirements are stated from the manufacture information the requirements are tied to mobile optics equipment it will be supporting and tested to that equipment.

Detector Type: Indium Antimonide (InSb)

Spectral Range: 3.0 – 5.0um

Resolution: 640 X 512 pixels

Sensor Cooling: Closed-cycle rotary

Zoom Ratio: 50-250mm continuous metric zoom with a 3X a focal attachment to allow for 150-750mm continuous metric zoom.

Integration Time: 480 ns to Full Frame

Sub window mode: Down to 16 x 4 px

Standard Video Out: SDI Video

High Speed Recording: 1-Year CoaXpress to SSD data recorder with Research Studio Pro Software perpetual license or equivalent software for “Or Equal” offer.

3X Lens extender to allow for 150-750mm zoom lens operation.

Self-contained filter wheel that allows for a number of neutral density filters to be installed in the enclosed lens assembly.

FLIR RS6780 Camera System 1 | Page

File details come from the government source that posted it. Updated .