RMAC 20-10 Requirements.pdf

PDF 226 KB Posted

Attached to
Sole Source, Resodyn Acoustic Mixer
Solicitation number
W31P4Q-20-Q-0034
Issued by

About this file

This document outlines requirements for a sole source federal contract opportunity. The Department of the Army Contracting Command-Redstone is soliciting a quote from Resodyn Acoustic Mixers, Incorporated to purchase one OmniRAM ResonantAcoustic Mixer System with accessories as detailed in an attached requirements document. Quotes are due by July 23, 2020 and must include historical pricing data to support fair and reasonable pricing. The contract will utilize commercial acquisition procedures and include standard clauses for implementation of statutes and trafficking in persons. The stated purpose is for the purchase of a mixer system for chemical mixing operations.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RMAC 20-10 TECHNICAL REQUIREMENTS

1.0 Description of Requirement:

The contractor shall provide the following items as specified in the table below:

Item

Number

Part Number Part Description Quantity

1 905120 OmniRAM ResonantAcoustic® Mixer, Stainless Steel, designed and built for Class

1, Division I, Class 2 Division I service, 230V

-Up to 100-g acceleration 386 in/sec2 (981 m/sec2)

-Mix capacity up to 5 kg

-Digital controls, real time monitoring, data capture, recipe control

-304L stainless steel enclosure

2 904855 Vessel Mount, Tri-Clamp Style

-Fits 1.25-gallon and 2-gallon mixing vessels

-Bottom mount

3 904872 1.25-Gallon Jacketed Mix Vessel, Tri-Clamp, SS

-316L Stainless Steel

-Tri-Clamp style Clamp

-32 RA surface finish

4 904822 Flat Lid for Jacketed Mix Vessel with Vacuum and RTD Ports

-316L Stainless Steel

-Fits 1.25-gallon and 2-gallon Mix Vessels

5 904823 RAM Motor Chiller – Indoor

-Cooling of the purged and sealed cabinet is required

6 904804 Resonator Subassembly for Jacketed Mix

Vessel Heater/Chiller

7 904825 Mixing Vessel Chiller (5.2kW) and Heater

(9kW)

8 904805 Resonator Subsystem for 10 Torr Vacuum 1

9 903797 10 Torr High Vacuum and Control System

Module for Mix Vessel

10 904828 Resonator Vacuum Pump (Class I Div 1) 1

11 903794 RTD Temperature and Vacuum Bridge

Assembly

12 904833 Resonator Subsystem for Temperature Sensor

System

-For one or two RTD’s

13 904851 RTD Temperature Sensor and Cable 1

14 904802 Mixing Temperature Process Control Module 1

RMAC 20-10 TECHNICAL REQUIREMENTS

15 904891 Mixing Temperature Process Functional

Control

16 904801 OmniRAM Remote Panel

-Includes 180’ of fiber

-USB connection to customer computer

17 904892 Light Tree for System Operational Status 1

18 904887 Hoist – Hazardous Location (Optional) 1

19 Class I, Div 1 and Class II, Div 1 Certification of the System

20 Factory Acceptance Test – Butte, MT

-Quality assurance documentation

-A three batch, pre-FAT test at Resodyn prior to shipment that can be witnessed by the client using surrogate, non-hazardous materials.

21 SAT, Installation, and Training

-On-site assembly

-Cabling and testing of the OmniRAM mixer

-On-site operation and maintenance training

22 Warranty

-Minimum 12 month warranty on equipment and labor to begin on the date of equipment delivery

2.0 Travel:

Travel is required in the performance of this contract for item 21.

3.0 Deliverables:

The above items shall be delivered to the following:

DEPARTMENT OF THE ARMY

CCDC, AvMC

7120 Redstone Road, Redstone Arsenal, AL, 35898-5000

Attention: Sarah Bolden, FCDD-AMW-PE, sarah.l.bolden.civ@mail.mil

File details come from the government source that posted it. Updated .