3.1 - 3.6

RFI Package Worksheet MW-2206-93 CENTRAL VENOUS CATHETER TRAYS, TRIPLE LUMEN
(1) Company name and address:
(2) Company POC (Name, phone number, fax number, and E-mail address):
(3) Commercial and Government Entity (CAGE) Code:
3.1 Maximal Sterile Barrier Tray with antimicrobial catheter.3.2 For each required component provide the following:
Required tray components. Please supply trays with the component amounts as indicated:a. Tray part number and Country of Origin (COO)b. Component manufacturer (MFR)c. Component MFR part numberd. Component COOe. Detailed component description (i.e., type, style, size, ply, material, woven, non-woven, etc.)
PLEASE DO NOT USE ABBREVIATIONS AND/OR ACCRONYMS.f. Please indicate which components have supply chain backlogs, if applicable. Please provide the duration of any expected product availability delays.
a. One (1) Indwelling Catheter: 7 FR X 20 cm, antimicrobial coated, pressure injectable (maximum pressure limit of 325 psi or greater), radiopaque, with cm depth markings.
b. One (1) Introducer needle
c. One (1) Catheter introducer needle
d. One (1) Guide wire
e. One (1) Tissue Dilator
f. Two (2) Luer lock syringe, 5 mL – 6 mL
g. One (1) Filter straw or blunt fill needle
h. One (1) Hypodermic safety needle, 25 Ga X 0.625 IN - 1 IN
i. One (1) Hypodermic safety needle, 22 Ga X 1.5 IN
j. One (1) 5 mL ampule, 1% lidocaine
k. One (1) Sharps safety system including but not limited to a needle block or sharps stick pad
l. Two (2) Site Skin Prep, 3 mL applicator with 2% chlorhexidine gluconate (CHG) and 70 % isopropyl alcohol (IPA) solution
m. Five (5) Gauze sponge, 2 IN x 2 IN (minimum 4 ply)
n. Five (5) Gauze sponge, 4 IN x 4 IN (minimum 4 ply)
o. One (1) Safety scalpel, #11 blade
p. One (1) Suture, silk with curved needle
q. One (1) Needle holder/driver
r. One (1) Primary catheter stabilization device
s. Three (3) Prefilled Luer lock syringe, normal saline 0.9% NaCl, 10 mL
t. Three (3) Luer Activated Needleless Connectors, neutral fluid displacement, clear, non-tinted housing
u. One (1) Ultrasound probe cover, universal size
v. Two (2) rubber bands, not made with natural rubber latex
w. One (1) Packet, ultrasound gel
x. One (1) Central venous catheter securement dressing, transparent face, impregnated/integrated with CHG OR One (1) Central venous catheter securement dressing, transparent face, with One (1) protective CHG disk
y. One (1) Drape, full body
z. One (1) Bouffant cap, universal size
aa. One (1) Surgical Gown, AAMI/ANSI:PB70 Level 4
bb. One (1) ASTM level 3, Mask with anti-glare and anti-fog resistant Eye shield
3.3 Please identify the specific antimicrobial coating your catheter is coated with for component 3.1.a.
VENDOR RESPONSE:
3.4 Describe how each tray would be packaged. Please provide a photo if you have examples of similar packaged trays.
VENDOR RESPONSE:
3.5 Is this tray commercially available?
VENDOR RESPONSE:
3.6 Provide any additional information, in addition to the specific information requested, which you consider relevant to this initiative.
VENDOR RESPONSE:

3.7 - 3.11

RFI Package Worksheet MW-2206-93 CENTRAL VENOUS CATHETER TRAYS, TRIPLE LUMEN
3.7 Maximal Sterile Barrier Tray with non-coated catheter.3.8 For each required component provide the following:
Required tray components. Please supply trays with the component amounts as indicated:a. Tray part number and Country of Origin (COO)b. Component manufacturer (MFR)c. Component MFR part numberd. Component COOe. Detailed component description (i.e., type, style, size, ply, material, woven, non-woven, etc.)
PLEASE DO NOT USE ABBREVIATIONS AND/OR ACCRONYMS.f. Please indicate which components have supply chain backlogs, if applicable. Please provide the duration of any expected product availability delays.
a. One (1) Indwelling Catheter: 7 FR X 20 cm, non-coated, pressure injectable (maximum pressure limit of 325 psi or greater), radiopaque, with cm depth markings.
b. One (1) Introducer needle
c. One (1) Catheter introducer needle
d. One (1) Guide wire
e. One (1) Tissue Dilator
f. Two (2) Luer lock syringe, 5 mL – 6 mL
g. One (1) Filter straw or blunt fill needle
h. One (1) Hypodermic safety needle, 25 Ga X 0.625 IN - 1 IN
i. One (1) Hypodermic safety needle, 22 Ga X 1.5 IN
j. One (1) 5 mL ampule, 1% lidocaine
k. One (1) Sharps safety system including but not limited to a needle block or sharps stick pad
l. Two (2) Site Skin Prep, 3 mL applicator with 2% chlorhexidine gluconate (CHG) and 70 % isopropyl alcohol (IPA) solution
m. Five (5) Gauze sponge, 2 IN x 2 IN (minimum 4 ply)
n. Five (5) Gauze sponge, 4 IN x 4 IN (minimum 4 ply)
o. One (1) Safety scalpel, #11 blade
p. One (1) Suture, silk with curved needle
q. One (1) Needle holder/driver
r. One (1) Primary catheter stabilization device
s. Three (3) Prefilled Luer lock syringe, normal saline 0.9% NaCl, 10 mL
t. Three (3) Luer Activated Needleless Connectors, neutral fluid displacement, clear, non-tinted housing
u. One (1) Ultrasound probe cover, universal size
v. Two (2) rubber bands, not made with natural rubber latex
w. One (1) Packet, ultrasound gel
x. One (1) Central venous catheter securement dressing, transparent face, impregnated/integrated with CHG OR One (1) Central venous catheter securement dressing, transparent face, with One (1) protective CHG disk
y. One (1) Drape, full body
z. One (1) Bouffant cap, universal size
aa. One (1) Surgical Gown, AAMI/ANSI:PB70 Level 4
bb. One (1) ASTM level 3, Mask with anti-glare and anti-fog resistant Eye shield
3.9 Describe how each tray would be packaged. Please provide a photo if you have examples of similar packaged trays.
VENDOR RESPONSE:
3.10 Is this tray commercially available?
VENDOR RESPONSE:
3.11 Provide any additional information, in addition to the specific information requested, which you consider relevant to this initiative.
VENDOR RESPONSE:

3.12 - 3.17

RFI Package Worksheet MW-2206-93 CENTRAL VENOUS CATHETER TRAYS, TRIPLE LUMEN
3.12 Procedure Tray with antimicrobial catheter.3.13 For each required component provide the following:
Required tray components. Please supply trays with the component amounts as indicated:a. Tray part number and Country of Origin (COO)b. Component manufacturer (MFR)c. Component MFR part numberd. Component COOe. Detailed component description (i.e., type, style, size, ply, material, woven, non-woven, etc.)
PLEASE DO NOT USE ABBREVIATIONS AND/OR ACCRONYMS.f. Please indicate which components have supply chain backlogs, if applicable. Please provide the duration of any expected product availability delays.
a. One (1) Indwelling Catheter: 7 FR X 20 cm, antimicrobial coated, pressure injectable (maximum pressure limit of 325 psi or greater), radiopaque, with cm depth markings.
b. One (1) Introducer needle
c. One (1) Catheter introducer needle
d. One (1) Guide wire
e. One (1) Tissue Dilator
f. Two (2) Luer lock syringe, 5 mL – 6 mL
g. One (1) Filter straw or blunt fill needle
h. One (1) Hypodermic safety needle, 25 Ga X 0.625 IN - 1 IN
i. One (1) Hypodermic safety needle, 22 Ga X 1.5 IN
j. One (1) 5 mL ampule, 1% lidocaine
k. One (1) Sharps safety system including but not limited to a needle block or sharps stick pad
l. Two (2) Site Skin Prep, 3 mL applicator with 2% chlorhexidine gluconate (CHG) and 70 % isopropyl alcohol (IPA) solution
m. Five (5) Gauze sponge, 2 IN x 2 IN (minimum 4 ply)
n. Five (5) Gauze sponge, 4 IN x 4 IN (minimum 4 ply)
o. One (1) Safety scalpel, #11 blade
p. One (1) Suture, silk with curved needle
q. One (1) Needle holder/driver
r. One (1) Primary catheter stabilization device
s. Three (3) Prefilled Luer lock syringe, normal saline 0.9% NaCl, 10 mL
t. Three (3) Luer Activated Needleless Connectors, neutral fluid displacement, clear, non-tinted housing
u. One (1) Ultrasound probe cover, universal size
v. Two (2) rubber bands, not made with natural rubber latex
w. One (1) Packet, ultrasound gel
x. One (1) Central venous catheter securement dressing, transparent face, impregnated/integrated with CHG OR One (1) Central venous catheter securement dressing, transparent face, with One (1) protective CHG disk
y. One (1) Drape, full body
3.14 Please identify the specific antimicrobial coating your catheter is coated with for component 3.1.a.
VENDOR RESPONSE:
3.15 Describe how each tray would be packaged. Please provide a photo if you have examples of similar packaged trays.
VENDOR RESPONSE:
3.16 Is this tray commercially available?
VENDOR RESPONSE:
3.17 Provide any additional information, in addition to the specific information requested, which you consider relevant to this initiative.
VENDOR RESPONSE:

3.18 - 3.22

RFI Package Worksheet MW-2206-93 CENTRAL VENOUS CATHETER TRAYS, TRIPLE LUMEN
3.18 Procedure Tray with non-coated catheter.3.19 For each required component provide the following:
Required tray components. Please supply trays with the component amounts as indicated:a. Tray part number and Country of Origin (COO)b. Component manufacturer (MFR)c. Component MFR part numberd. Component COOe. Detailed component description (i.e., type, style, size, ply, material, woven, non-woven, etc.)
PLEASE DO NOT USE ABBREVIATIONS AND/OR ACCRONYMS.f. Please indicate which components have supply chain backlogs, if applicable. Please provide the duration of any expected product availability delays.
a. One (1) Indwelling Catheter: 7 FR X 20 cm, non-coated, pressure injectable (maximum pressure limit of 325 psi or greater), radiopaque, with cm depth markings.
b. One (1) Introducer needle
c. One (1) Catheter introducer needle
d. One (1) Guide wire
e. One (1) Tissue Dilator
f. Two (2) Luer lock syringe, 5 mL – 6 mL
g. One (1) Filter straw or blunt fill needle
h. One (1) Hypodermic safety needle, 25 Ga X 0.625 IN - 1 IN
i. One (1) Hypodermic safety needle, 22 Ga X 1.5 IN
j. One (1) 5 mL ampule, 1% lidocaine
k. One (1) Sharps safety system including but not limited to a needle block or sharps stick pad
l. Two (2) Site Skin Prep, 3 mL applicator with 2% chlorhexidine gluconate (CHG) and 70 % isopropyl alcohol (IPA) solution
m. Five (5) Gauze sponge, 2 IN x 2 IN (minimum 4 ply)
n. Five (5) Gauze sponge, 4 IN x 4 IN (minimum 4 ply)
o. One (1) Safety scalpel, #11 blade
p. One (1) Suture, silk with curved needle
q. One (1) Needle holder/driver
r. One (1) Primary catheter stabilization device
s. Three (3) Prefilled Luer lock syringe, normal saline 0.9% NaCl, 10 mL
t. Three (3) Luer Activated Needleless Connectors, neutral fluid displacement, clear, non-tinted housing
u. One (1) Ultrasound probe cover, universal size
v. Two (2) rubber bands, not made with natural rubber latex
w. One (1) Packet, ultrasound gel
x. One (1) Central venous catheter securement dressing, transparent face, impregnated/integrated with CHG OR One (1) Central venous catheter securement dressing, transparent face, with One (1) protective CHG disk
y. One (1) Drape, full body
3.20 Describe how each tray would be packaged. Please provide a photo if you have examples of similar packaged trays.
VENDOR RESPONSE:
3.21 Is this tray commercially available?
VENDOR RESPONSE:
3.22 Provide any additional information, in addition to the specific information requested, which you consider relevant to this initiative.
VENDOR RESPONSE: