PERFORMANCE WORK STATEMENT (PWS)
PWS 23-3A9
5 December 2022 Project Engineer:
1.0 SCOPE:
1.1 TITLE: EDAX X-Ray Spectroscopy Tool Preventative Maintenance Service Contract
1.2 APPLICABILITY: Defense Microelectronics Activity (DMEA), Semiconductor Assurance Forensics Engineering (SAFE)
1.3 BACKGROUND: The EDAX X-Ray Spectroscopy tools are tools the Validation group uses for Failure Analysis (FA) of semiconductors. There are three (3) total tools, two (2) Energy Dispersive X-Ray Spectroscopy (EDS) systems and one (1) Wavelength Dispersive X-Ray Spectroscopy (WDS) system. The tools are composed of various complex X-Ray Microscope components that need to be in precise calibration at all times. The EDS systems each contain a Silicon Drift Detector (SDD) that are used to detect the excited X-Rays.
1.4 PURPOSE: To purchase a preventative maintenance service contract to ensure the proper function and maximum accuracy and precision of the tool to minimize downtime. The purchase shall include one (1) base year. The service contract should only cover the EDAX EDS Detector for Helios 660, serial number 4773.
2.0 REFERENCED GOVERNMENT PROVIDED RESOURCES:
2.1 GOVERNMENT DOCUMENTS:
2.2 OTHER DOCUMENTS:
2.3 GOVERNMENT FURNISHED EQUIPMENT:
| Equipment Name |
| Serial Number |
| Current Service Expiration |
| Date Available |
| EDAX EDS Detector for Helios 660 |
| 4773 |
| 20230310 |
| TBD |
2.4 GOVERNMENT FURNISHED INFORMATION:
2.5 GOVERNMENT FURNISHED FACILITIES/ACCESS:
| Facility/Access |
| Date |
| Building 620, Room 134 (Lab 1) |
| TBD |
3.0 REQUIREMENTS:
3.1 GENERAL REQUIREMENTS:
3.1.1 RESERVED
3.2 PROGRAM MANAGEMENT: None
3.3 TASK REQUIREMENTS:
3.3.1 REQUIREMENT:
3.3.1.1 PREVENTATIVE MAINTENANCE: The contractor shall provide, at a time agreed upon by the contractor and DMEA, at least one (1) preventative maintenance (PM) visit including labor, living expenses and travel to DMEA. During the PM visit, the contractor shall ensure that the system is back to full operational condition meeting OEM specifications.
3.3.1.2 SOFTWARE: The contractor shall provide the latest software updates and upgrades to the TEAM software, when released. The software updates shall be provided on a CD, sent to DMEA prior to the scheduled visit for installing the software update.
3.3.1.3 ON-SITE HARDWARE SUPPORT: The contractor shall provide unlimited on-site visits, including labor, living expenses, and travel to DMEA to provide support and repair any malfunctions to return the tool to full operational condition meeting OEM specifications. The contractor shall replace any parts or component needing to be replaced with equivalent or better quality parts at no additional cost to DMEA. Components to be covered shall include:
3.3.1.3.1 EDS Detector – Octane Super -A
3.3.1.3.1.1 Silicon Drift Detector Module
3.3.1.3.2 Helios Support Computer Analyzer
3.3.1.3 REMOTE TECHNICAL SUPPORT: The contractor shall provide email and telephone support for the EDAX EDS system Monday through Friday between the hours of 0800 to 1500 Pacific Time, except on Federal Holidays.
3.3.1.3.1 If DMEA contacts the contractor regarding support, the contractor shall respond to DMEA within four (4) hours, if within normal business hours in 3.3.1.3.
3.3.1.3.2 If a site visit is required to return the tool to full operational condition meeting OEM specifications, the contractor shall report to DMEA within five (5) business days of the reported issue.
3.3.1.4 SECURITY:
3.3.1.4.1 The contractor must provide DMEA at least two (2) business days advance notification prior to conducting any on-site inspection, installation, maintenance, modification, repair, or training.
3.3.1.4.2 All services shall be performed by US citizens.
3.3.1.4.3 Prior to being allowed entry to the DMEA facility, all contractor personnel shall provide proof of citizenship in according with the DMEA visitor approval process in effect at the time that the visit is requested.
3.3.1.4.4. During periods of exceptionally heightened security, additional advanced notice and background investigations of contractor personnel may be required prior to gaining entry to DMEA.
3.3.1.4.5 If the contractor requires the use of a laptop during the service visit, DMEA must be notified prior to the visit and laptop must be checked by DMEA Security prior to entering the laboratory. All recording devices and wireless communications must be disabled, including but not limited to the camera, microphone, wireless internet, Bluetooth, etc.
3.3.1.4.6 The on-site contractor personnel will be issued a badge each day that they are required to be on-site and shall return the badge to DMEA security personnel at the end of each work day.
3.3.1.4.7 Contractor personnel must comply with all DMEA Security policies and instructions at all times.
3.4 PROGRAM SUMMARY: To purchase one (1) base year and the option to purchase four (4) additional years of service for the Octane Elite Super on the Helios 660 Dual Beam serial #4773.