PW2026-026_Central_W_HQ_Electrical_100CD_Rev1_-_signed.pdf
PDF 7 MB Posted
- Solicitation number
- PW#2025-026
- Issued by
- King County, Spokane City, Washington
About this file
This is a site plan and general notes document for an electrical service relocation project administered by the City of Seattle Department of Parks and Recreation, Planning & Development Division, with the City of Seattle Department of Finance & Administrative Services as the owner. The project involves relocating electrical service at the Central West Headquarters facility located at 1403 W Howe Street, Seattle, WA 98119. The scope of work includes obtaining temporary overhead service from Seattle City Light, demolishing the existing electrical mast, replacing the existing 240D/120V/3PH/4W/600A service with new equipment, installing a new service mast, weather head, current transformer, meter, service disconnect, and main distribution panel, and backfeeding existing loads from the new distribution board. The project also requires obtaining a street use permit from the Seattle Department of Transportation for street crossing and providing a backup generator for service shutdowns during the cut-over process. The Engineer's Estimate for the project is $221,154.00.
The contract documents specify that all work must conform to the 2026 or latest edition of the City of Seattle Standard Specifications and Plans for Road, Bridge and Municipal Construction and all applicable codes and regulations. The contractor is solely responsible for independently verifying utility locations and discovering any utilities not shown on the plans, maintaining sedimentation control, keeping walkways clear, using designated staging and storage areas, and repairing any damaged facilities to the Engineer's specifications. An architect representative will be on-site part-time to observe construction for compliance with design intent and document any hidden conditions requiring design modifications. The contractor must coordinate all operations with the Engineer, including site access, materials storage, utility service interruptions, and the sequence of work. Parking for the contractor and workers is at their own expense, and all work must comply with applicable codes, laws, and regulations of all authorities having jurisdiction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4.6
0'
157.98'
PR
OP
ER
TY
LI
NE
CENTRAL WEST
HEADQUARTERS
6.0
0' P
RO
PE
RT
Y
LIN
E
275.96' PROPERTY LINE
PROPERTY LINE 429.25'
(E) STOR. SHEDS 275.96'
6.0
0'
429.25'
4.6
0'
157.98'
WEST HOWE STREET
TH
A
VE
NU
E W
ES
T
CENTRAL WEST
HEADQUARTERS
BARREL VAULT
TRENCH FOR (N) CONDUIT AND
CONDUCTORS. SEE ELEC. DWGS.
(E) UTILITY POLE AND
TRANSFORMER
SHEET INDEXGENERAL NOTESSITE PLAN
Central West Headquarters Electrical Service Relocation
Administering Department:
City of Seattle Department of Parks and Recreation, Planning & Development Division
300 Elliott Avenue West, Suite 100, Seattle, WA 98119 Project Manager: Ray Gontarz 206-584-7034
Owner:
City of Seattle Department of Finance & Administrative Services, Purchasing & Contracting
1. ALL WORK SHALL CONFORM TO THE 2026 OR THE LATEST EDITION OF THE CITY OF SEATTLE STANDARD SPECIFICATIONS AND PLANS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION AND
ALL APPLICABLE CODES AND REGULATIONS.
2. A COPY OF THE APPROVED CONTRACT DOCUMENTS SHALL BE ON SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
3. ALL UTILITIES SHOWN HAVE BEEN ESTABLISHED BY FIELD OBSERVATION OR AVAILABLE RECORDS AND SHOULD BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT
SHOWN ON THE PLAN WHICH MAY BE AFFECTED BY CONSTRUCTION.
4. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN SEDIMENTATION CONTROL AND COLLECTION FACILITIES TO PREVENT ERODED SOILS FROM ENTERING THE PUBLIC DRAINAGE SYSTEM DURING
EXECUTION OF THE CONTRACT.
5. KEEP ALL WALKWAYS CLEAR AND FREE OF DEBRIS. PAVED SURFACES THAT ARE DAMAGED
DURING CONSTRUCTION SHALL BE REPAIRED TO THE SATISFACTION OF THE ENGINEER.
6. STORAGE OF MATERIALS AND EQUIPMENT WILL BE ALLOWED ONLY IN AREAS DESIGNATED FOR
CONSTRUCTION OR STAGING. STAGING AND STORAGE AREAS TO BE VERIFIED WITH ENGINEER
PRIOR TO START OF WORK.
7. ALL FACILITIES SCHEDULED TO REMAIN THAT ARE DAMAGED DURING THE COURSE OF EXECUTION
OF THE WORK SHALL BE REPLACED BY THE CONTRACTOR TO THE ENGINEERS SPECIFICATIONS.
THESE FACILITIES MAY INCLUDE ASPHALT AND CONCRETE PAVING, BENCHES, RAILINGS,
IRRIGATION, VEGETATION, FENCING, BUILDING AND VARIOUS UTILITIES.
8. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND
REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK.
9. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, MEASUREMENTS AND CONDITIONS
IN THE FIELD BEFORE BEGINNING WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE
BROUGHT TO THE ATTENTION OF THE ENGINEER AND THE ARCHITECT IMMEDIATELY.
10. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, PART-TIME TO OBSERVE THE
CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN
RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL
KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED
DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND
THE ENGINEER WILL ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS
SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES.
11. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR
PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE
CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB
AND SQUARE.
12. DETAILED AND/OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER
SCALE DRAWINGS. CONTRACTOR TO USE DIMENSIONS SHOWN AND NOT TO SCALE DRAWINGS.
13. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND
PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING
INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND
DO NOT SHOW EVERY DETAIL.
14. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS
THOSE DRAWN FOR SIMILAR CONDITIONS.
15. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH THE ENGINEER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL, MECHANICAL, FIRE-ALARM, LOW-VOLTAGE SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO
VERIFY SEQUENCE OF WORK WITH THE ENGINEER.
16. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING DUST BARRIERS AT ALL INTERIOR WORK
LOCATIONS AND DURING ALL PHASES OF THE WORK.
17. PATCH AND REPAIR ALL LOCATIONS; WALLS, CEILINGS, OR FLOORS WHERE EXISTING EQUIPMENT IS MOVED, RELOCATED, OR REMOVED AND REPLACED. TOUCH-UP PAINT SHALL MATCH EXISTING ADJACENT WALL IN SHEEN, COLOR, AND TEXTURE. WHERE MORE THAN ONE SQ. FT. OF WALL OR CEILING SPACE REQUIRES TOUCH-UP PAINTING, CONTRACTOR SHALL PAINT ENTIRE WALL FROM
CORNER TO CORNER, FLOOR TO CEILING, OR TOP OF WAINSCOT TO CEILING.
18. THE DRAWINGS HAVE BEEN COORDINATED TO THE EXTENT POSSIBLE WITH AS-BUILT
CONDITIONS. THE ENGINEER SHALL APPROVE ALL RELOCATIONS OF SURFACE MOUNTED
FIXTURES AND EQUIPMENT WHERE A CONFLICT IN THE FIELD IS NOT INDICATED ON THE
DRAWINGS.
19. PARKING ON THE STREET AND/OR PARKING GARAGE SHALL BE THE CONTRACTOR'S AND
WORKERS' OWN EXPENSE.
PROJECT TEAM
SITE INFORMATION
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
PROJECT DESCRIPTION
GENERAL
1. G0.1 COVER SHEET
2. G1.1 SITE PLAN
3. G2.1 REFERENCE PHOTOS
ARCHITECTURAL
4. A1.1 FLOOR PLAN
5. A5.3 DETAILS
ELECTRICAL
6. E0.1 ELECTRICAL LEGEND AND SCHEDULES
7. ED1.1 DEMO SITE PLAN
8. ED2.1 DEMO FLOOR PLAN
9. E1.1 ELECTRICAL SITE PLAN
10. E2.1 POWER FLOOR PLANS
11. E8.1 SUPPLEMENTAL DOCS
12. E9.1 RISER DIAGRAMS
13. E10.1 PANEL SCHEDULES
ARCHITECT
OAI, PS
1001 SW KLICKITAT WAY #204
SEATTLE WA 98134
PRIMARY CONTACT:
JERRY OSBORN
(206) 920-6348 josborn@oaips.com
PROJECT ADDRESS: 1403 W HOWE STREET
OWNER: SEATTLE PARKS AND RECREATION
300 ELLIOTT AVENUE W
SEATTLE WA 98119
PARCEL NUMBER: 242503-9137
ZONING: NR1
LEGAL DESCRIPTION:
PAR B OF SEATTLE SHORT PLAT #9106178 PER REC
#9204140811 SD SP DAF - POR OF N 386 FT OF GL 2 LY BET
W LN OF HELSING ADD & E LN OF IS TH AVE W LESS ST
PLAT BLOCK:
PLAT LOT:
1. OBTAIN TEMPORARY,OVERHEAD SERVICE FROM SEATTLE CITY
LIGHT (TO ALLOW EXPEDITED DEMOLITION OF EXISTING MAST).
2. DEMOLISH EXISTING MAST AS SOON AS TEMPORARY SERVICE IS
ESTABLISHED,
3. REPLACE EXISTING 240D/120V/3PH/4W/600A SERVICE WITH NEW.
4. DEMOLISH EXISTING WEATHERHEAD AND OVERHEAD SERVICE.
MAINTAIN EXISTING LOW VOLTAGE WEATHERHEAD AND
SERVICE.
5. INSTALL NEW SERVICE MAST, WEATHER HEAD, CT, METER,
SERVICE DISCONNECT AND NEW MAIN DISTRIBUTION PANEL.
6. BACKFEED EXISTING LOADS FROM NEW MAIN DISTRIBUTION
BOARD.
7. PROVIDE BACK-UP GENERATOR FOR SERVICE SHUT-DOWN AND
CUT-OVER IN CASE ADDITIONAL DOWNTIME REQUIRED.
8. OBTAIN STREET USE PERMIT FROM SEATTLE DEPARTMENT OF
TRANSPORTATION FOR STREET CROSSING
OWNER
SEATTLE PARKS AND RECREATION
300 ELLIOTT AVENUE WEST SUITE 100
SEATTLE WA 98119
PRIMARY CONTACT:
RAY GONTARZ
(206) 584-7034 ray.gontarz@seattle.gov
CURRENT CODES
2021 SEATTLE BUILDING CODE
2021 SEATTLE ENERGY CODE
2021 SEATTLE EXISTING BUILDING CODE
2023 SEATTLE ELECTRICAL CODE
2021 SEATTLE FIRE CODE
2021 SEATTLE PLUMBING CODE
BUILDING INFORMATION
BUILDING AREA: 14,324 SQ FT
CONSTRUCTION TYPE: TYPE III B (1992 UBC TYPE III-N HOUR)
OCCUPANCY GROUP: S-2 STORAGE (VEHICLE MAINTENANCE)
PW#2026-026 Project # PRK730300-375 Funding Source: General Bond Int/Redemptn Fund
COVERSHEET
JO
CG
JO
NO SCALE
1 13
G0.1
REGISTERED
ARCHITECT
JERRY D. OSBORN
STATE OF WASHINGTON
CENTRAL WEST HEADQUARTERS
ELECTRICAL SERVICE
RELOCATION
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
PROJECT ASSET LIST
ASSET ID ASSET DESCRIPTION CATEGORY DESCRIPTION INVOLVEMENT NOTES
TBD NO NEW ASSETS IN THE PROJECT SCOPE ADD
ROOF-WCDHQ CENTRAL WEST DIST HQ ROOF UNSPECIFIED ROOF FULL RENOVATION/REFRESH
ARCHSYS-WCDHQ CENTRAL WEST DIST HQ ARCH SYS ARCHITECTURAL SYSTEM PARTIAL RENOVATION/REFRESH
BUILDING-WCDHQ CENTRAL WEST DIST HQ BUILDING OTHER BUILDING NOT INVOLVED
ELECSYS-WCDHQ CENTRAL WEST DIST HQ ELECTRICAL SYS BUILDING ELECTRICAL SYSTEM PARTIAL RENOVATION/REFRESH
NEW ASSETS
EXISTING ASSETS
ASSET ID ASSET DESCRIPTION ASSET CATEGORY DESCRIPTION INVOLVEMENT NOTES
SCALE: 1" = 50'
TREE PROTECTION
NO SHT ID SHEET TITLE
50 25 0 50 100
SCALE IN FEET
TREE PROTECTION/DEVELOPMENT IMPACT AREA REQUIREMENTS:
1. RETENTION AND PROTECTION OF ALL TREES 6 INCHES OR GREATER IS REQUIRED.
2. NO TREE REMOVAL OR DAMAGE UNLESS AUTHORIZED.
3. EXCAVATION AND GROUND DISTURBANCE IS PROHIBITED OUTSIDE THE
DEVELOPMENT IMPACT AREA.
4. CONSTRUCTION-RELATED ACTIVITIES, SUCH AS SITE ACCESS, HEAVY EQUIPMENT
USE, STORAGE, OR STOCKPILING IS PROHIBITED OUTSIDE THE DEVELOPMENT
IMPACT AREA UNLESS LOCATED ON EXISTING HARD SURFACES.
08/10/2026
8/10 26
AutoCAD SHX Text
APPROVED FOR ADVERTISING:
AutoCAD SHX Text Presley Palmer
AutoCAD SHX Text Seattle, Washington
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text Purchasing & Contracting
AutoCAD SHX Text Director, Purchasing & Contracting
AutoCAD SHX Text Signature:
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text 1/6/2026
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text 127362 https://seattlegov.na1.adobesign.com/verifier?tx=CBJCHBCAABAAbiPuV2yiIm5XGz6eQ2yn7_B9EokoIGSY
4.6
0'
157.98'
PR
OP
ER
TY
LI
NE
CENTRAL WEST
HEADQUARTERS
6.0
0' P
RO
PE
RT
Y
LIN
E
275.96' PROPERTY LINE11
PROPERTY LINE 429.25'
(E) STOR. SHEDS
CONCRETE SIDEWALK
PEDESTRIAN PATH
ASPHALT
PAVEMENT
PRIMARY ENTRANCE
AND DRIVEWAY
PA
RK
IN
G
WEST HOWE STREET
TH
A
VE
NU
E
W
ES
T
ASPHALT
PAVEMENT
5'- 0"
31'-9"
0'-
0"
322'-9"
'-0
RO
W
CONCRETE SIDEWALK
EXIT DRIVEWAY
TH
A
VE
NU
E
W
ES
T
TH
A
VE
NU
E
W
ES
T
WEST BLAINE STREET
TH
A
VE
NU
E
W
ES
T
TH
A
VE
NU
E
W
ES
T
ROOFING CONTRACTOR'S
LAY-DOWN, STAGING AREA.
AND ROOF LOADING
LOCATION. COORDINATE
WITH PROJECT ENGINEER.
CONTRACTOR -
MAINTAIN CLEAR
EGRESS PATH FROM
BUILDING
DEVELOPMENT IMPACT
AREA IS LIMITED TO
ROOF AREA, LAY-DOWN,
STORAGE AND STAGING
AREA
TRENCH FOR CONDUIT AND
CONDUCTORS. SEE ELEC. DWGS.
(E) UTILITY POLE &
TRANSFORMER
REMOVE (E) VINE MAPLE AND BUSHES TO
BE REMOVED BY OTHERS. TREE
REPLACEMENT BY OTHERS.
(E) FENCE LINE
ELECTRICAL CONTRACTOR'S STORAGE AND STAGING
AREA. COORDINATE WITH PROJECT ENGINEER.
ELECTRICAL CONTRACTOR'S TEMPORARY GENERATOR
(E) ELECTRICAL SERVICE MAST
SCALE:1 OVERALL SITE PLAN
1' = 30'
LEGEND
SITE INFORMATION
PROJECT ADDRESS: 1403 W HOWE STREET
OWNER: SEATTLE PARKS AND RECREATION
300 ELLIOTT AVE W #100
SEATTLE WA 98119
PARCEL NUMBER: 242503-9137
LEGAL DESCRIPTION:
PAR B OF SEATTLE SHORT PLAT #9106178 PER REC
#9204140811 SD SP DAF - POR OF N 386 FT OF GL 2 LY BET
W LN OF HELSING ADD & E LN OF IS TH AVE W LESS ST
PLat Block:
Plat Lot:
SCOPE OF WORK
30 15 0 30 60
SCALE IN FEET
1. OBTAIN TEMPORARY,OVERHEAD SERVICE FROM SEATTLE CITY
LIGHT (TO ALLOW EXPEDITED DEMOLITION OF EXISTING MAST).
2. DEMOLISH EXISTING MAST AS SOON AS TEMPORARY SERVICE IS
ESTABLISHED,
3. REPLACE EXISTING 240D/120V/3PH/4W/600A SERVICE WITH NEW.
4. DEMOLISH EXISTING WEATHERHEAD AND OVERHEAD SERVICE.
MAINTAIN EXISTING LOW VOLTAGE WEATHERHEAD AND SERVICE.
5. INSTALL NEW SERVICE MAST, WEATHER HEAD, CT, METER,
SERVICE DISCONNECT AND NEW MAIN DISTRIBUTION PANEL.
6. BACKFEED EXISTING LOADS FROM NEW MAIN DISTRIBUTION
BOARD.
7. PROVIDE BACK-UP GENERATOR FOR SERVICE SHUT-DOWN AND
CUT-OVER IN CASE ADDITIONAL DOWNTIME REQUIRED.
8. OBTAIN STREET USE PERMIT FROM SEATTLE DEPARTMENT OF
TRANSPORTATION FOR STREET CROSSING.
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
REGISTERED
ARCHITECT
JERRY D. OSBORN
STATE OF WASHINGTON
SITE PLAN
JO
CG
JO
AS NOTED
2 13
G1.1
PARCELS
PHOTO REFERENCES. SEE SHEET G2.1. 08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text 127362
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text 1/6/2026
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
9 ELECTRICAL ROOM 103 - (E) ELCTRICAL PANEL
5 POWER MAST
1 OVERHEAD POWER LINES
6 SHOP 109 - (N) ELECTRICAL PANEL LOCATION
2 ROOF CORE
7 ELECTRICAL ROOM 103
3 EXISTING POWER MASTS
8 (E) ELECTRICAL PANEL
4 POWER MAST
ELECTRICAL POWER MASTS TO
BE REMOVED.
EXISTING UTIITY POLES
(E) UTILITY POLE
MAPLE TREE AND BUSHES
REMOVAL BY OTHERS.
REPLACEMENT BY OTHERS.
ELECTRICAL POWER SERVICE
HEADS
ELECTRICAL MASTS TO BE
REMOVED.
(E) ELECTRICAL PANELS
EXISTING MAPLE TREE TO BE REMOVED.
TREE REPLACEMENT BY OTHERS
APPROXIMATE LOCATIONS OF
(N) DISCONNECT, METER AND
CT CAN. SEE ELECTRICAL
DRAWINGS.
APPROXIMATE LOCATION OF
(N) ELECTRICAL PANEL. SEE
ELECTRICAL DRAWINGS.
(E) RAIN LEADER
COMMUNICATIONS MAST
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
REGISTERED
ARCHITECT
JERRY D. OSBORN
STATE OF WASHINGTON
REFERENCE PHOTOS
CG
JO
3 13
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text 127362
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text 1/6/2026
1 2 3 4 5 6 7 8 9 10 11 12
E
D
C
B
A
SHOP
SHOP
ELECTRICAL
JAN
MENS
TOILET
WOMENS
LOCKER
AREA
A118
CORRIDOR
A121
WOMENS
A119
MENS
A120CORRIDOR
A122
LUNCH
ROOM
A123
STORAGE
A124
STORAGE
A125
GOLD ROOM
A127
GOLD ROOM
A128
SUPPLY
HALLWAY
OFFICE
OFFICE
OFFICE
OFFICE
MUD ROOM
A117
CHEMICAL
MIXING ROOM
A114
HERBICIDE
STORAGE
A115
PESTICIDE
STORAGE
A116
SHOP
A126
CHAIN LINK FENCE STORAGE BINS
'-2
200'-2"
108'-2" 16'-8"75'-4"
'-2
ELECTRICAL CONTRACTOR'S
STORAGE AND STAGING AREA.
COORDINATE WITH PROJECT
ENGINEER.
ROOFING CONTRACTOR'S
STORAGE AND STAGING AREA.
(N) ELEC. DISTRIBUTION
BOARD
(E) ELEC. PANEL A
(N) ELEC. JUNCTION BOX
(E) UTILITY POLE
(E) ELEC. PANELS(E) ELEC. PANEL
MAPLE TREE AND
BUSH REMOVAL BY
OTHERS. TREE
REPLACEMENT BY
OTHERS.
TRENCH FOR
CONDUIT AND
CONDUCTORS.
SEE ELEC. DWGS.
SCALE:1 FLOOR PLAN
1/8" = 1' - 0"
TREE PROTECTION
TREE PROTECTION/DEVELOPMENT IMPACT AREA REQUIREMENTS:
1. RETENTION AND PROTECTION OF ALL TREES 6 INCHES OR
GREATER IS REQUIRED.
2. NO TREE REMOVAL OR DAMAGE UNLESS AUTHORIZED.
3. EXCAVATION AND GROUND DISTURBANCE IS PROHIBITED
OUTSIDE THE DEVELOPMENT IMPACT AREA.
4. CONSTRUCTION-RELATED ACTIVITIES, SUCH AS SITE ACCESS,
HEAVY EQUIPMENT USE, STORAGE, OR STOCKPILING IS
PROHIBITED OUTSIDE THE DEVELOPMENT IMPACT AREA
UNLESS LOCATED ON EXISTING HARD SURFACES.
SCALE IN FEET
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
REGISTERED
ARCHITECT
JERRY D. OSBORN
STATE OF WASHINGTON
FLOOR PLAN
CG
JO
1/8" = 1' - 0"
4 13
A1.1
08/10/2026
AutoCAD SHX Text
AutoCAD SHX Text A5.3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text 127362
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text 1/6/2026
AutoCAD SHX Text 8&9
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text G2.1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:1 TRENCH DETAIL
3/4" = 1' - 0"
3" M
IN
LOW-STRENGTH FTB
ENCASEMENT PER
SCL 7150.00
TYPICAL BASE
SPACER SUPPORT
CDF BACKFILL TO
SUBGRADE
UNDISTURBED
EARTH
MARKING TAPE
3"
M
IN
3" MIN
6" MAX
3" MIN
6" MAX
CONDUIT
1'-
6"
PAY OR NEAT LINE FINISH TRENCH GRADE TO MATCH
LANDSCAPING OR PAVEMENT
TRENCH IS TO MEET THE REQUIREMENTS
OF SCL STANDARD 0224.07
3'- 0"
MI
N.
C
OV
ER
2"
MIN
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
REGISTERED
ARCHITECT
JERRY D. OSBORN
STATE OF WASHINGTON
DETAILS
CG
JO
AS NOTED
5 13
A5.3
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text 127362
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text 1/6/2026
1. COMPLY WITH 2021 SEATTLE COMMERCIAL ENERGY CODE.
PROJECT NOTES
2. INSTALLATION SHALL COMPLY WITH 2023 SEATTLE ELECTRIC CODE.
3. INSTALLATION SHALL COMPLY WITH 2021 INTERNATIONAL BUILDING CODE.
4. INSTALLATION SHALL COMPLY WITH 2021 INTERNATIONAL FIRE CODE.
1. REPLACE EXISTING 240D/120V/3PH/4W/600A SERVICE WITH NEW.
PROJECT SCOPE
2. DEMOLISH EXISTING WEATHERHEAD AND OVERHEAD SERVICE. MAINTAIN
EXISTING LOW VOLTAGE WEATHERHEAD AND SERVICE.
3. INSTALL NEW SERVICE MAST, WEATHER HEAD, CT, METER, SERVICE DISCONNECT
AND NEW MAIN DISTRIBUTION PANEL.
4. BACKFEED EXISTING LOADS FROM NEW MAIN DISTRIBUTION BOARD.
5. PROVIDE BACK-UP GENERATOR FOR SERVICE SHUT-DOWN AND CUT-OVER
INCASE ADDITIONAL DOWNTIME REQUIRED.
5. ELECTRICAL CONTRACTOR TO APPLY AND ATTAIN ELECTRICAL PERMIT INCLUDING
ALL PERMIT FEES AND ASSOCIATED PLANS.
6. ELECTRICAL CONTRACTOR TO APPLY AND ATTAIN TEMPORARY SEATTLE CITY
LIGHT ELECTRICAL SERVICE TO BACKFEED EXISTING TO ACCOMMODATE
RE-ROOFING AND EXISTING SERVICE MAST REMOVAL.
5. PROVIDE BACK-UP GENERATOR FOR SERVICE SHUT-DOWN AND CUT-OVER
INCASE ADDITIONAL DOWNTIME REQUIRED.
1. REPLACE EXISTING 240D/120V/3PH/4W/600A SERVICE WITH NEW.
2.
DEMOLISH EXISTING WEATHERHEAD AND OVERHEAD SERVICE. MAINTAIN
EXISTING LOW VOLTAGE WEATHERHEAD AND SERVICE.
4. INSTALL NEW SERVICE MAST, WEATHER HEAD, CT, METER, SERVICE DISCONNECT
AND NEW MAIN DISTRIBUTION PANEL.
5. BACKFEED EXISTING LOADS FROM NEW MAIN DISTRIBUTION BOARD.
6. PROVIDE BACK-UP GENERATOR FOR SERVICE SHUT-DOWN AND CUT-OVER
INCASE ADDITIONAL DOWNTIME REQUIRED.
3.
PROVIDE TEMPORARY SEATTLE CITY LIGHT OVERHEAD SERVICE TO TEMP POWER
AND SKID TO BACKFEED EXISTING SERVICE THROUGH CONSTRUCTION.
7. SEATTLE CITY LIGHT STANDARDS;
-0224.01 CUSTOMER REQUIREMENTS FOR SECONDARY UNDERGROUND SERVICE,
LOOPED RADIAL SYSEM
-0224.07 REQUIREMENTS FOR SECONDARY CONDUIT INSTALLATIONS
-1561.07 CUSTOMER REQUIREMENTS FOR UNDERGROUND SECONDARY SERVICE
TERMINATION FACILITIES
-0101.75 EXCAVATING NEAR SCL POLES
7/02/2026
7/2/2026
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
ABBREVIATIONS
FIRE ALARM SYSTEM EQUIPMENT
E1.1
AUDIO/VISUAL DEVICES
POWER RECEPTACLES & OUTLETS
TELE/COMMUNICATIONS SYSTEM DEVICES
SECURITY SYSTEM EQUIPMENT
INTERCOM/CLOCK SYSTEM DEVICES
EQUIPMENT CONNECTIONS & CONTROLS
SERVICE GEAR - AS SHOWN ON PLANS
CONDUITS AND CIRCUITING
LIGHT FIXTURES & CONTROLS
NOTES AND MISCELLANEOUS SYMBOLS
ELECTRICAL LEGEND
NOTE:
ELECTRICAL LEGEND
E0.1
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
MICHAEL CASE
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text 127362
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
AL
AutoCAD SHX Text
ATS
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
MANUAL PULL STATION
AutoCAD SHX Text
WALL MOUNTED STROBE (ONLY) ALARM
AutoCAD SHX Text
CEILING MOUNTED HORN/STROBE ALARM
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
HEAT DETECTOR
AutoCAD SHX Text
DUCT SMOKE DETECTOR
AutoCAD SHX Text
MAGNETIC DOOR HOLDER
AutoCAD SHX Text
WALL MOUNTED HORN/STROBE ALARM
AutoCAD SHX Text
CEILING MOUNTED STROBE (ONLY) ALARM
AutoCAD SHX Text
TAMPER SWITCH
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
BEAM SMOKE DETECTOR TRANSMITTER
AutoCAD SHX Text
BEAM SMOKE DETECTOR RECEIVER
AutoCAD SHX Text J
AutoCAD SHX Text
FIRE/SMOKE DAMPER
AutoCAD SHX Text
FACP
AutoCAD SHX Text
FIRE ALARM CONTROL PANEL
AutoCAD SHX Text
AutoCAD SHX Text MECHANICAL FLAG - DEFINES MECHANICAL EQUIPMENT AND COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND SCHEDULES. COORESPONDS TO MECHANICAL CONNECTION SCHEDULE IN THE ELECTRICAL SET.
AutoCAD SHX Text FLAGNOTE - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT EXPLAINS DETAILS OR FEATURES OF THAT ITEM.
AutoCAD SHX Text EQUIPMENT FLAG - DEFINES SPECIAL (IE: COOKING) EQUIPMENT ON A PLAN AND COORESPONDS TO DESIGNATIONS IN AN EQUIPMENT SCHEDULE IN THE ELECTRICAL SET.
AutoCAD SHX Text IDENTIFICATION SYMBOL - CROSS REFERENCES INFORMATION IN ONE AREA WITH A DETAIL (TOP #) AND SHEET (BOTTOM #) IN ANOTHER IN THE ELECTRICAL SET.
AutoCAD SHX Text A
AutoCAD SHX Text (200A)
AutoCAD SHX Text
(AFTER A NUMBER) = AMPS
AutoCAD SHX Text
AF
AutoCAD SHX Text
(AFTER A NUMBER) = FUSE SIZE IN AMPS
AutoCAD SHX Text
(200AF)
AutoCAD SHX Text
AUTOMATIC TRANSFER SWITCH
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AFF
AutoCAD SHX Text
BKR
AutoCAD SHX Text
BREAKER
AutoCAD SHX Text
CKT
AutoCAD SHX Text
CIRCUIT
AutoCAD SHX Text
CLG
AutoCAD SHX Text
CEILING
AutoCAD SHX Text C.O.
AutoCAD SHX Text
CONDUIT ONLY
AutoCAD SHX Text C
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
CRP
AutoCAD SHX Text
CONTROL RELAY PANEL
AutoCAD SHX Text
CU
AutoCAD SHX Text
COPPER
AutoCAD SHX Text
DISC
AutoCAD SHX Text
DISCONNECT
AutoCAD SHX Text
DF
AutoCAD SHX Text
DRINKING FOUNTAIN
AutoCAD SHX Text
DISP
AutoCAD SHX Text
DISPOSER
AutoCAD SHX Text
DW
AutoCAD SHX Text
DISHWASHER
AutoCAD SHX Text E.C.
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXISTING (USED AS SYMBOL DESIGNATION)
AutoCAD SHX Text
EMT
AutoCAD SHX Text
ELECTRICAL METALLIC TUBING
AutoCAD SHX Text
EXTG
AutoCAD SHX Text
EXISTING (USED AS ABBREVIATION IN TEXT)
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
FSD
AutoCAD SHX Text
FIRE SMOKE DAMPER
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
GROUND FAULT CIRCUIT INTERRUPTER
AutoCAD SHX Text
GND
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
HWT
AutoCAD SHX Text
HOT WATER TANK
AutoCAD SHX Text
LCP
AutoCAD SHX Text
LIGHTING CONTROL PANEL
AutoCAD SHX Text
LTS(LTG)
AutoCAD SHX Text
LIGHTS (LIGHTING)
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MLO
AutoCAD SHX Text
MAIN LUGS ONLY
AutoCAD SHX Text
MCB
AutoCAD SHX Text
MAIN CIRCUIT BREAKER
AutoCAD SHX Text
MSC
AutoCAD SHX Text
MULTI-SCENE CONTROLLER
AutoCAD SHX Text N3R
AutoCAD SHX Text
NEMA 3R
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
OC
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
PNL
AutoCAD SHX Text
PANELBOARD
AutoCAD SHX Text
LV
AutoCAD SHX Text
LOW VOLTAGE
AutoCAD SHX Text
LT
AutoCAD SHX Text
LIGHT
AutoCAD SHX Text kCMIL
AutoCAD SHX Text
THOUSANDS OF CIRCULAR MILS
AutoCAD SHX Text
KVA
AutoCAD SHX Text
1000 VOLT AMPERES
AutoCAD SHX Text
REC
AutoCAD SHX Text
RECEPTACLE(S)
AutoCAD SHX Text
REF
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text (R)
AutoCAD SHX Text
RELOCATED EXISTING
AutoCAD SHX Text
RQMTS
AutoCAD SHX Text
REQUIREMENTS
AutoCAD SHX Text
SW
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
HOA
AutoCAD SHX Text
HAND-OFF-AUTO
AutoCAD SHX Text
TBD
AutoCAD SHX Text
TO BE DETERMINED
AutoCAD SHX Text
UL
AutoCAD SHX Text
UNDERWRITER'S LABORATORY
AutoCAD SHX Text U.O.N.
AutoCAD SHX Text
UNLESS OTHERWISE NOTED
AutoCAD SHX Text
WAP
AutoCAD SHX Text
WIRELESS ACCESS POINT
AutoCAD SHX Text
WC
AutoCAD SHX Text
WATER COOLER
AutoCAD SHX Text
UC
AutoCAD SHX Text
UNDER COUNTER
AutoCAD SHX Text
WP
AutoCAD SHX Text
WEATHERPROOF
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
OS
AutoCAD SHX Text
OCCUPANCY SENSOR
AutoCAD SHX Text
VS
AutoCAD SHX Text
VACANCY SENSOR
AutoCAD SHX Text
PC
AutoCAD SHX Text
PHOTOCELL
AutoCAD SHX Text
AUTHORITY HAVING JURISDICTION
AutoCAD SHX Text
AHJ
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text W/O
AutoCAD SHX Text
WITHOUT
AutoCAD SHX Text
UTIL
AutoCAD SHX Text
UTILITY
AutoCAD SHX Text
UG
AutoCAD SHX Text
UNDERGROUND
AutoCAD SHX Text
SQ
AutoCAD SHX Text
SQUARE
AutoCAD SHX Text
HH
AutoCAD SHX Text
HANDHOLE
AutoCAD SHX Text
MH
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
DIA
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
CL
AutoCAD SHX Text
CENTERLINE
AutoCAD SHX Text
HTR
AutoCAD SHX Text
HEATER
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text S
AutoCAD SHX Text M
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text
FSD
AutoCAD SHX Text H
AutoCAD SHX Text
FF-3
AutoCAD SHX Text
AutoCAD SHX Text
KW
AutoCAD SHX Text
1000 WATTS
AutoCAD SHX Text
SCL
AutoCAD SHX Text
SEATTLE CITY LIGHT
AutoCAD SHX Text
SPD
AutoCAD SHX Text
SURGE PROTECTIVE DEVICE
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VARIABLE FREQUENCY DRIVE
AutoCAD SHX Text
VA
AutoCAD SHX Text
VOLT AMPERES
AutoCAD SHX Text W
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
ECB
AutoCAD SHX Text
ENCLOSED CIRCUIT BREAKER
AutoCAD SHX Text
GEN
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text
WP
AutoCAD SHX Text
DUPLEX RECEPTACLE WITH 1/2 SWITCHED
AutoCAD SHX Text
TAMPER RESISTANT RECEPTACLE
AutoCAD SHX Text
JUNCTION BOX WITH BLANK COVER
AutoCAD SHX Text
SINGLE RECEPTACLE
AutoCAD SHX Text
DUPLEX RECEPTACLE
AutoCAD SHX Text
DOUBLE DUPLEX RECEPTACLE
AutoCAD SHX Text DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.)
AutoCAD SHX Text
DUPLEX GFCI RECEPTACLE
AutoCAD SHX Text
DOUBLE DUPLEX GFCI RECEPTACLE
AutoCAD SHX Text DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.)
AutoCAD SHX Text DOUBLE DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.)
AutoCAD SHX Text DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.)
AutoCAD SHX Text
GFCI RECEPTACLE WITH WEATHERPROOF WHILE-IN-USE COVER
AutoCAD SHX Text
DUPLEX RECEPTACLE MOUNTED IN CEILING
AutoCAD SHX Text
FLUSH FLOOR OUTLET BOX WITH DEVICES SHOWN
AutoCAD SHX Text
FLOOR POKE-THRU WITH DEVICES SHOWN
AutoCAD SHX Text
DUPLEX RECEPTACLE MOUNTED ON WIREMOLD
AutoCAD SHX Text
DOUBLE DUPLEX RECEPTACLE MOUNTED ON WIREMOLD
AutoCAD SHX Text
DUPLEX RECEPTACLE MOUNTED HORIZONTALLY
AutoCAD SHX Text
SINGLE SPECIAL PURPOSE RECEPTACLE
AutoCAD SHX Text FURNITURE SYSTEM POWER FEED. CONNECT CONDUCTORS TO FURNITURE SYSTEM FLEX CONDUIT PROVIDED BY OTHERS. VERIFY REQUIREMENTS.
AutoCAD SHX Text
CLOCK OUTLET (RECESSED 120V RECEPTACLE)
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT)
AutoCAD SHX Text W
AutoCAD SHX Text
SINGLE GANG TELEPHONE/DATA OPENING
AutoCAD SHX Text
DATA/COMM OUTLET (NUMBER INDICATES NUMBER OF JACKS. 'B' INDICATES BLANK PLATE)
AutoCAD SHX Text
JUNCTION BOX & CONDUIT FOR FURNITURE SYSTEM TELE/DATA CONNECTIONS
AutoCAD SHX Text
TELEVISION OUTLET
AutoCAD SHX Text
DOORBELL
AutoCAD SHX Text
POWER POLE WITH DEVICES SHOWN
AutoCAD SHX Text TELEPHONE TERMINAL BOARD - 3/4" FIRE RESISTANT PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN
AutoCAD SHX Text
TTB
AutoCAD SHX Text
VE
AutoCAD SHX Text
CARD READER ACCESS OUTLET
AutoCAD SHX Text
SECURITY SYSTEM PANEL
AutoCAD SHX Text
AUDIO AUXILLIARY INPUT
AutoCAD SHX Text
AUDIO/VISUAL OUTLET (SEE DRAWING NOTES FOR TYPE)
AutoCAD SHX Text
WALL MOUNTED SPEAKER
AutoCAD SHX Text
CEILING MOUNTED SPEAKER
AutoCAD SHX Text
MICROPHONE/AUXILIARY JACK COMBINATION PLATE
AutoCAD SHX Text
REMOTE VOLUME CONTROLLER
AutoCAD SHX Text ±19"x19" TWO-POST FLOOR MOUNTED DATAEQUIPMENT RACK
AutoCAD SHX Text ±18"x20" WALL MOUNTED DATA EQUIPMENT RACK
AutoCAD SHX Text
SPEAKER, CEILING MOUNTED
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text
SSP
AutoCAD SHX Text
CR
AutoCAD SHX Text
KP
AutoCAD SHX Text
KEYPAD
AutoCAD SHX Text
VIDEO ENTRY LIGHT
AutoCAD SHX Text
DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING
AutoCAD SHX Text
WIRELESS ACCESS POINT
AutoCAD SHX Text
WAP
AutoCAD SHX Text
ASSISTED LISTENING DEVICE
AutoCAD SHX Text
INFRARED RECEIVER FOR WIRELESS MICROPHONE SYSTEM
AutoCAD SHX Text
MICROPHONE JACK
AutoCAD SHX Text
SPEAKER, WALL MOUNTED
AutoCAD SHX Text
SPEAKER, WALL MOUNTED, EXTERIOR
AutoCAD SHX Text
DIGITAL CLOCK COMBINATION OUTLET
AutoCAD SHX Text
ANALOG CLOCK OUTLET
AutoCAD SHX Text
BELL, WALL MOUNTED
AutoCAD SHX Text A
AutoCAD SHX Text
AL
AutoCAD SHX Text
IR
AutoCAD SHX Text M
AutoCAD SHX Text
MA
AutoCAD SHX Text
RV
AutoCAD SHX Text S
AutoCAD SHX Text
TV
AutoCAD SHX Text
AV
AutoCAD SHX Text
AV
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text
AV
AutoCAD SHX Text D
AutoCAD SHX Text
VOLUME SWITCH
AutoCAD SHX Text V
AutoCAD SHX Text
CALL (PANIC) SWITCH
AutoCAD SHX Text P
AutoCAD SHX Text T
AutoCAD SHX Text
CIRCUIT BREAKER PANELBOARD
AutoCAD SHX Text
SWITCHBOARD OR MOTOR CONTROL CENTER, SIZE AS SHOWN ON PLANS
AutoCAD SHX Text
LOAD CENTER
AutoCAD SHX Text
EQUIPMENT CONNECTION
AutoCAD SHX Text
MOTOR CONNECTION
AutoCAD SHX Text
FAN CONNECTION
AutoCAD SHX Text
TRANSFER SWITCH
AutoCAD SHX Text
UTILITY TRANSFORMER
AutoCAD SHX Text
METER
AutoCAD SHX Text
WEATHERHEAD (PLAN VIEW)
AutoCAD SHX Text
UTILITY POWER POLE (SITE PLAN)
AutoCAD SHX Text
GROUND ROD LOCATION
AutoCAD SHX Text
HANDHOLE OR PULLBOX (SITE PLAN)
AutoCAD SHX Text
PADDLE FAN
AutoCAD SHX Text
HEAT LAMP
AutoCAD SHX Text
EXHAUST FAN/LIGHT COMBINATION
AutoCAD SHX Text
EXHAUST FAN/HEAT LAMP COMBINATION
AutoCAD SHX Text
ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT
AutoCAD SHX Text
WALL MOUNTED THERMOSTAT
AutoCAD SHX Text
ELECTRIC UNIT HEATER
AutoCAD SHX Text
ELECTRIC WALL HEATER CONTROLLED BY WALL MOUNTED THERMOSTAT
AutoCAD SHX Text
ELECTRIC BASEBOARD HEATER (LENGTH & WATTAGE ON PLAN)
AutoCAD SHX Text
DISCONNECT SWITCH
AutoCAD SHX Text
COMBINATION STARTER AND DISCONNECT
AutoCAD SHX Text
MAGNETIC MOTOR STARTER
AutoCAD SHX Text
ENCLOSED CIRCUIT BREAKER
AutoCAD SHX Text
START-STOP PUSHBUTTON SWITCH
AutoCAD SHX Text
PUSHBUTTON SWITCH
AutoCAD SHX Text S
AutoCAD SHX Text M
AutoCAD SHX Text
MOTOR RATED SWITCH
AutoCAD SHX Text
WIRING CONCEALED IN CEILING OR WALL
AutoCAD SHX Text
WIRING CONCEALED UNDER FLOOR OR UNDERGROUND
AutoCAD SHX Text
CONDUIT HOME-RUN
AutoCAD SHX Text
CONDUIT STUB-UP
AutoCAD SHX Text
CONDUIT BREAK
AutoCAD SHX Text
CONDUIT WITH BELL END
AutoCAD SHX Text
CONDUIT TO BE REMOVED
AutoCAD SHX Text
MULTI-OUTLET ASSEMBLY (SEE NOTES ON PLAN)
AutoCAD SHX Text
CABLE TRAY
AutoCAD SHX Text
GROUND WIRE
AutoCAD SHX Text
LIGHTING CONTROL PANEL
AutoCAD SHX Text
CONDUIT CONTINUES ELSEWHERE (NOTED ON PLAN)
AutoCAD SHX Text
HAND/OFF/AUTO SWITCH
AutoCAD SHX Text
EXISTING PANELBOARD TO REMAIN
AutoCAD SHX Text
TERMINAL CABINET
AutoCAD SHX Text T
AutoCAD SHX Text
DRY TYPE TRANSFORMER (SEE NOTES & RISER DIAGRAM FOR SIZE)
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
PP
AutoCAD SHX Text
CONDUIT BENDS TO CHANGE ELEVATION AT THIS POINT
AutoCAD SHX Text
WALL MOUNTED EQUIPMENT CONNECTION
AutoCAD SHX Text F
AutoCAD SHX Text H
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text
FUSED DISCONNECT SWITCH
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VARIABLE FREQUENCY DRIVE
AutoCAD SHX Text
SURFACE CEILING MOUNTED DOWNLIGHT
AutoCAD SHX Text
RECESSED DOWNLIGHT (ROUND)
AutoCAD SHX Text
PENDANT MOUNTED FIXTURE OR CHANDELIER
AutoCAD SHX Text
FLOODLIGHT OR MONOPOINT
AutoCAD SHX Text
RECESSED DOWNLIGHT (SQUARE)
AutoCAD SHX Text
RECESSED WALLWASHER
AutoCAD SHX Text
SURFACE MOUNTED LINEAR FIXTURE
AutoCAD SHX Text
RECESSED LINEAR FIXTURE
AutoCAD SHX Text
PENDANT MOUNTED LINEAR FIXTURE
AutoCAD SHX Text
LINEAR STRIP FIXTURE
AutoCAD SHX Text
LINEAR INDUSTRIAL STRIP FIXTURE
AutoCAD SHX Text
LINEAR UNDERCOUNTER FIXTURE
AutoCAD SHX Text
SINGLE POINT SOURCE WALL MOUNTED FIXTURE
AutoCAD SHX Text
WALL SCONCE
AutoCAD SHX Text
WALL MOUNTED LONG ARM FIXTURE
AutoCAD SHX Text
WALL MOUNTED STRIP FIXTURE
AutoCAD SHX Text
WALL MOUNTED LINEAR FIXTURE
AutoCAD SHX Text
RECESSED LINEAR WALLWASHER
AutoCAD SHX Text
TRACK LIGHT (LENGTH AS SHOWN ON PLAN)
AutoCAD SHX Text LED COVE OR UNDER COUNTER LIGHT (LENGTH AS SHOWN ON PLAN, TRANSFORMER(S) SHOWN AS REQUIRED)
AutoCAD SHX Text
SURFACE MOUNTED LINEAR FIXTURE (NARROW BODY)
AutoCAD SHX Text T
AutoCAD SHX Text
SURFACE LINEAR EMERGENCY EGRESS FIXTURE
AutoCAD SHX Text 2'x4' FIXTURE SPLIT BETWEEN NORMAL & EMERGENCY EGRESS WITH UL924 RELAY. DUAL CIRCUITS SHOWN ON PLANS.
AutoCAD SHX Text
RECESSED EMERGENCY EGRESS DOWNLIGHT
AutoCAD SHX Text
SURFACE EMERGENCY EGRESS DOWNLIGHT
AutoCAD SHX Text
WALL MOUNTED INDUSTRIAL LINEAR FIXTURE
AutoCAD SHX Text NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, MOUNTING & EMERGENCY EGRESS INFORMATION ONLY. REFER TO FIXTURE DESIGNATIONS & LIGHTING FIXTURE SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS.
AutoCAD SHX Text
RECESSED STEP LIGHT
AutoCAD SHX Text
UNIVERSAL/CEILING MOUNTED EXIT SIGN
AutoCAD SHX Text
WALL MOUNTED EXIT SIGN
AutoCAD SHX Text
DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES AND DIRECTION INDICATED)
AutoCAD SHX Text
EMERGENCY EXIT SIGN WITH DUAL PATHWAY HEADS
AutoCAD SHX Text
ARM MOUNTED POLE LIGHT (ON SITE PLAN)
AutoCAD SHX Text
DUAL HEADED ARM MOUNTED POLE LIGHT (ON SITE PLAN)
AutoCAD SHX Text
DUAL HEAD EMERGENCY EGRESS FIXTURE
AutoCAD SHX Text
POST TOP AREA LIGHT
AutoCAD SHX Text
ARM WALL MOUNTED DOCK LIGHT
AutoCAD SHX Text
RECESSED DIRECT BURIAL FLOODLIGHT
AutoCAD SHX Text H-3/X-23
AutoCAD SHX Text
DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED
AutoCAD SHX Text
FAAP
AutoCAD SHX Text
FIRE ALARM ANNUNCIATOR PANEL
AutoCAD SHX Text
FACP
AutoCAD SHX Text
FIRE ALARM CONTROL PANEL
AutoCAD SHX Text
OH
AutoCAD SHX Text
OVERHEAD
AutoCAD SHX Text
FUT
AutoCAD SHX Text
FUTURE
AutoCAD SHX Text F.O.I.C.
AutoCAD SHX Text
FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR
AutoCAD SHX Text
AutoCAD SHX Text REVISION CLOUD AND FLAG - CLOUD SURROUNDS INFORMATION THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN WHICH THE CHANGES WERE MADE.
AutoCAD SHX Text
NREC
AutoCAD SHX Text
NON-RESIDENTIAL ENERGY CODE
AutoCAD SHX Text
SENSOR POWER PACK
AutoCAD SHX Text
PHOTOCELL AIMED NORTH, MOUNTED ON BUILDING EXTERIOR
AutoCAD SHX Text
PP
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text R1
AutoCAD SHX Text b
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text K
AutoCAD SHX Text
THREE POLE LIGHT SWITCH
AutoCAD SHX Text
FOUR POLE LIGHT SWITCH
AutoCAD SHX Text
PHOTOCELL LIGHT SENSOR
AutoCAD SHX Text
OCCUPANCY SENSOR LIGHT SWITCH
AutoCAD SHX Text
DIMMER SWITCH
AutoCAD SHX Text
LIGHT SWITCH WITH PILOT LIGHT
AutoCAD SHX Text
KEYED SWITCH
AutoCAD SHX Text
VACANCY SENSOR LIGHT SWITCH
AutoCAD SHX Text LIGHT SWITCH SUBSCRIPTS ARE AS FOLLOWS: LV = LOW VOLTAGE, D = DIMMING b = LOWER CASE LETTER CORRESPONDS TO LETTER AT FIXTURES TO BE CONTROLLED R# = RELAY # IN LIGHTING CONTROL PANEL S# = SENSOR ZONE
AutoCAD SHX Text
OCCUPANCY SENSOR
AutoCAD SHX Text
OS
AutoCAD SHX Text
PC
AutoCAD SHX Text
VACANCY SENSOR
AutoCAD SHX Text
VS
AutoCAD SHX Text S
AutoCAD SHX Text
SINGLE POLE LIGHT SWITCH
AutoCAD SHX Text
LOW VOLTAGE SWITCH CONTROLLED BY ROOM SENSOR
AutoCAD SHX Text
RECESSED LINEAR EMERGENCY EGRESS FIXTURE
AutoCAD SHX Text
FLOODLIGHT, MONOPOINT OR TRACK HEAD EGRESS
AutoCAD SHX Text
EGRESS COVE LIGHT OR STRIP
AutoCAD SHX Text S
AutoCAD SHX Text
LV
AutoCAD SHX Text S
AutoCAD SHX Text
VS
AutoCAD SHX Text S
AutoCAD SHX Text
OS
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text
LVD
AutoCAD SHX Text
MW
AutoCAD SHX Text
MICROWAVE
AutoCAD SHX Text
NEUTRAL CONDUCTOR
AutoCAD SHX Text
GROUND CONDUCTOR
AutoCAD SHX Text
PHASE CONDUCTOR(S)
AutoCAD SHX Text
CONDUCTORS IN CONDUIT
AutoCAD SHX Text
VP
AutoCAD SHX Text
COMBINATION VACANCY/PHOTOCELL SENSOR
AutoCAD SHX Text SYMBOLS SHOWN ON PLANS IN STANDARD (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK.
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text SYMBOLS SHOWN IN LIGHT LINE WEIGHT OR DESIGNATED WITH (E) INDICATE EXISTING TO REMAIN.
AutoCAD SHX Text
SYMBOLS SHOWN AS DASHED INDICATE ITEMS TO BE REMOVED OR DEMOLISHED.
AutoCAD SHX Text (E)
AutoCAD SHX Text
THESE STANDARDS APPLY ON ALL ELECTRICAL DRAWINGS UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
EV
AutoCAD SHX Text
ELECTRIC VEHICLE (CHARGER)
AutoCAD SHX Text
MULTI-DIRECTIONAL SECURITY CAMERA AS SHOWN
PR
OP
ER
TY
LI
NE
WEST CENTRAL
HEADQUARTERS
157.98'
4.6
0'
PROVIDE LABOR AND MATERIALS AS REQUIRED TO
COORDINATE SEATTLE CITY LIGHT SERVICE DISCONNECT
AND RE-CONNECT TO NEW. SEE FLAG NOTE 1, SHEET ED1.1,
FOR ADDITIONAL INFORMATION.
FLAG NOTES
DEMOLISH EXISTING OVERHEAD SERVICE CONDUCTORS.2
(E)SCL POWER POLE
& POLE MOUNTED
TRANSFORMERS
(D)MDP
(D)CTELECTRICAL
(D)METER
DEMOLITION NOTES
1.
2.
3.
4. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE
WIRE BY ONE WIRE SIZE.
WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK
UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST
BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT
BOXES.
PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC,
NEC, AND SPECIFICATIONS SECTIONS 26 0510, 26 0511, 26 0519,
26 0532 AND 26 0533 FOR A FULLY FUNCTIONING SYSTEM.
REFER TO THE DEMOLITION RISER DIAGRAM, SHEET E9.1, FOR
ADDITIONAL INFORMATION.
(D)WEATHERHEAD
7/02/2026
7/2/2026
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
DEMOLITION SITE PLAN
NORTH
DEMO SITE PLAN
ED1.1
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
MICHAEL CASE
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text 127362
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE: 1" = 20'-0"
D
C
B
A
GARAGE
GARAGE
CHAIN LINK FENCE STORAGE BINS
ELECTRICAL
JAN
MENS
TOILET
WOMENS
LOCKER
AREA
A118
CORRIDOR
A121
WOMENS
A119
MENS
A120
CORRIDOR
A122
LUNCH
ROOM
A123
STORAGE
A124
STORAGE
A125
GOLD ROOM
A127
GOLD ROOM
A128
SHOP
A126
SUPPLY
HALLWAY
OFFICE
OFFICE
OFFICE
OFFICE
MUD ROOM
A117
CHEMICAL
MIXING ROOM
A114
HERBICIDE
STORAGE
A115
PESTICIDE
STORAGE
A116
1.
DEMOLITION NOTES
PROVIDE LABOR AND MATERIALS AS REQUIRED TO INTERCEPT
AND MAINTAIN EXISTING FEEDER FOR RECONNECTION TO
NEW DISTRIBUTION. SEE FLAG NOTE 1, SHEET E2.1, FOR
ADDITIONAL INFORMATION. CONDUIT ROUTING SHOWN FOR
REFERENCE ONLY. FIELD VERIFY EXACT CONDUIT ROUTING.
FLAG NOTES
PROVIDE LABOR AND MATERIALS AS REQUIRED DEMOLISH
INTERIOR COMPONENTS TO EXISTING PANEL AND UTILIZE FOR
AS JUNCTION BOX. INTERCEPT AND MAINTAIN EXISTING
BRANCH CIRCUITS FOR RECONNECTION TO NEW DISTRIBUTION.
SEE FLAG NOTE 2, SHEET E2.1, FOR ADDITIONAL
INFORMATION.
DEMOLITION CT CAN ABOVE PANEL.3
(D)MDP
(E)A
(E)B(E)SP-A
J
(E)C
(D)METER
2.
3.
4. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE
WIRE BY ONE WIRE SIZE.
WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK
UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE
MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT BOXES.
PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC,
AND SPECIFICATIONS SECTIONS 26 0510, 26 0511, 26 0519, 26 0532
AND 26 0533 FOR A FULLY FUNCTIONING SYSTEM.
REFER TO THE DEMOLITION RISER DIAGRAM, SHEET E9.1, FOR
ADDITIONAL INFORMATION.
7/02/2026
7/2/2026
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
DEMO FLOOR PLAN
ED2.1
DEMOLITION POWER FLOOR PLAN
NORTH
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
MICHAEL CASE
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text 127362
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
PR
OP
ER
TY
LI
NE
WEST CENTRAL
HEADQUARTERS
157.98'
4.6
0'
GENERAL NOTES
(E)SCL POWER POLE
& POLE MOUNTED
TRANSFORMERS
(N)CTFWP
(N)METER
(N)MDP
1.
2.
3.
4.
5.
6.
7.
PROVIDE LABOR AND MATERIALS AS REQUIRED TO
COORDINATE SEATTLE CITY LIGHT NEW UNDERGROUND
SERVICE CONDUCTORS CONNECTION TO EXISTING
TRANSFORMER. SEE FLAG NOTE 1, SHEET ED1.1, FOR
ADDITIONAL INFORMATION.
FLAG NOTES
NEW (1)-4"C. TO SCL POWER POLE. CONDUCTORS BY
SEATTLE CITY LIGHT. SEE APPLICABLE SCL STANDARDS.
PROVIDE NEW EXTERIOR CT CAN AND METER PER SEATTLE
CITY LIGHT STANDARDS. SEE SCL STANDARDS 0224.01,
0224.07, 1561.07 AND 0101.75 FOR SCL STANDARDS AND
PROVIDE.
ALL NEW MECHANICAL AND PLUMBING EQUIPMENT SHOWN THAT
REQUIRES SERVICING TO BE SERVICED VIA RECEPTACLE WITHIN SAME
ROOM. PROVIDE ADDITIONAL SERVICE RECEPTACLES WITHIN 25' OF
EQUIPMENT IF NONE PRESENT AND ASBUILT CIRCUIT NUMBER.
SERVICE RECEPTACLE TO BE GFCI PROTECTED PER NEC 210.8.E &
210.63.B.2. CHANGE EXISTING NORMAL RECEPTACLE TO GFCI IF
ONE IS PRESENT.
PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH
CIRCUIT.
HOMERUNS SHALL NOT BE COMBINED.
FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE
WIRE BY ONE WIRE SIZE.
WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK
UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST
BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT
BOXES.
PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC,
NEC, AND SPECIFICATIONS SECTIONS 26 0510, 26 0511, 26 0519,
26 0532 AND 26 0533 FOR A FULLY FUNCTIONING SYSTEM.
REFER TO THE RISER DIAGRAM, SHEET E9.1, FOR ADDITIONAL
INFORMATION.
APPLICABLE SCL LIGHT STANDARDS
0224.01 CUSTOMER REQUIREMENTS FOR SECONDARY
UNDERGROUND SERVICE, LOOPED RADIAL SYSTEM
0224.07 REQUIREMENTS FOR SECONDARY CONDUIT INSTALLATION
1561.07 CUSTOMER REQUIREMENTS FOR UNDERGROUND
SECONDARY SERVICE TERMINATION FACILITIES
0101.75 EXCAVATING NEAR SCL POLES
7/02/2026
7/2/2026
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
ELECTRICAL SITE PLAN
NORTH
ELECTRICAL SITE PLAN
E1.1
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
MICHAEL CASE
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text 127362
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE: 1" = 20'-0"
D
C
B
A
GARAGE
GARAGE
CHAIN LINK FENCE STORAGE BINS
ELECTRICAL
JAN
MENS
TOILET
WOMENS
LOCKER
AREA
A118
CORRIDOR
A121
WOMENS
A119
MENS
A120
CORRIDOR
A122
LUNCH
ROOM
A123
STORAGE
A124
STORAGE
A125
GOLD ROOM
A127
GOLD ROOM
A128
SHOP
A126
SUPPLY
HALLWAY
OFFICE
OFFICE
OFFICE
OFFICE
MUD ROOM
A117
CHEMICAL
MIXING ROOM
A114
HERBICIDE
STORAGE
A115
PESTICIDE
STORAGE
A116
1.
GENERAL NOTES
PROVIDE LABOR AND MATERIALS AS REQUIRED TO EXTEND
MAINTAIN EXISTING FEEDER TO NEW DISTRIBUTION. SEE FLAG
NOTE 1, SHEET E2.1, FOR ADDITIONAL INFORMATION.
CONDUIT ROUTING SHOWN FOR REFERENCE ONLY. FIELD
VERIFY EXACT CONDUIT ROUTING.
FLAG NOTES
PROVIDE LABOR AND MATERIALS AS REQUIRED RE-FEED
EXISTING PANEL SHOWN.
NEW EXTERIOR CT CAN AND METER.4
NEW EXTERIOR 208V/3P/600A FUSIBLE WEATHERPROOF
SERVICE DISCONNECT.
(N)JB
(E)A
(E)B(E)SP-A
J
(E)C
(N)MDP
PROVIDE LABOR AND MATERIALS AS REQUIRED RE-FEED
EXISTING BRANCH CIRCUITS. UTIILIZE DEMOLISHED
PANELBOARD AS JUNCTION BOX AS REQUIRED.
(D)METER
F5
(2)3"C-4#500KCMIL AL
& 1#2/0 AL GND
3"C-4#300KCMIL AL
& 1#2 AL GND
2-1/2"C-4#3/0 AL
& 1#4 AL GND
2.
3.
4.
5.
6.
7. ALL NEW MECHANICAL AND PLUMBING EQUIPMENT SHOWN THAT
REQUIRES SERVICING TO BE SERVICED VIA RECEPTACLE WITHIN SAME
ROOM. PROVIDE ADDITIONAL SERVICE RECEPTACLES WITHIN 25' OF
EQUIPMENT IF NONE PRESENT AND ASBUILT CIRCUIT NUMBER.
SERVICE RECEPTACLE TO BE GFCI PROTECTED PER NEC 210.8.E &
210.63.B.2. CHANGE EXISTING NORMAL RECEPTACLE TO GFCI IF ONE
IS PRESENT.
PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH
CIRCUIT.
HOMERUNS SHALL NOT BE COMBINED.
FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE
WIRE BY ONE WIRE SIZE.
WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK
UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE
MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT BOXES.
PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC,
AND SPECIFICATIONS SECTIONS 26 0510, 26 0511, 26 0519, 26 0532
AND 26 0533 FOR A FULLY FUNCTIONING SYSTEM.
REFER TO THE RISER DIAGRAM, SHEET E9.1, FOR ADDITIONAL
INFORMATION.
7/02/2026
7/2/2026
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection Request Line (206) 684-7034.
>>>>CAUTION - CALL 811<<<<
UTILITY NOTIFICATION CENTER
BEFORE YOU DIG!
WWW.CALL811.COM
CENTRAL WEST HEADQUARTERS
1001 SW Klickitat Way, Suite 204 Seattle WA 98134 p: 206.631.8442 | www.oaips.com
ELECTRICAL SERVICE
RELOCATION
FLOOR PLAN
E2.1
POWER FLOOR PLAN
NORTH
08/10/2026
AutoCAD SHX Text
REVISION - AS BUILT
AutoCAD SHX Text
SPECIFICATION NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ORDINANCE NO.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWED:
AutoCAD SHX Text
PARK ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text All work done in accordance with the City of Seattle Standard Plans and Specifications in effect on the date shown above, and supplemented by Special Provisions.
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
MICHAEL CASE
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text
TIM NICHOLS
AutoCAD SHX Text 127362
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
7/02/2026
7/2/2026
Also, verify all underground utilities not located by the 811 service by using a commercial location service and call SPR Inspection…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .