Project Statement 472-26275.pdf
PDF 166 KB Posted
- Solicitation number
- RFP 171 260000002439 2
- Issued by
- Michigan
About this file
Summary
This is a Project Statement for a food service fire suppression system installation at the Ionia Correctional Facility (JGH) in Michigan, prepared by the Michigan Department of Corrections. The project involves the design and installation of a complete hood and suppression system for the facility's food service kitchen, including pre-engineered fire suppression equipment, ductwork, and all associated components necessary to bring the system into full operational compliance. The scope encompasses removal of existing equipment as needed, installation of new suppression technology, and system testing to ensure proper functionality. The project is designed to enhance fire safety in the food preparation area and meet current fire code requirements for institutional kitchen operations.
The project is funded through the Michigan Department of Corrections capital budget and represents a standard procurement for facility safety improvements at a state correctional institution. This appears to be a competitive solicitation for qualified contractors experienced in commercial kitchen fire suppression system installation. The work is expected to be completed in a single phase, with all labor, materials, and equipment provided by the successful bidder. Documentation and specifications for the system installation, including manufacturer requirements and inspection procedures, are included as part of the project requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP Billable Rate 472-26275.pdf | ||
| LEIN Request 26275.pdf | ||
| Addendum 1 26275.pdf | ||
| DTMB-0441 (R 19.02) 2.pdf | ||
| SAMPLE Billable Rate Contract (Rev 04-25).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0427 (R 04/26)
PROJECT STATEMENT
STATE OF MICHIGAN
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration Design and Construction Division
3111 West St. Joseph Street Lansing, Michigan 48909
FILE NUMBER
472/26275.JGH
PROPOSAL DUE DATE
Thursday August 27th at 2:00 p.m., EASTERN
CLIENT AGENCY
Department of Corrections
PROJECT NAME AND LOCATION
Ionia Correctional Facility (ICF) – Food Service Fire Suppression and Fire Alarm Systems Upgrade
PROJECT ADDRESS
1576 Bluewater Highway Ionia, MI 48846
CLIENT AGENCY CONTACT
Ben Verway
TELEPHONE NUMBER
517-388-2171
DTMB - DCD PROJECT DIRECTOR
Jared Gavin-Helfrich
TELEPHONE NUMBER
517-290-1516
WALK-THROUGH INSPECTION DATE, TIME, AND LOCATION:
On site at Ionia Correctional Facility – Meet in the lobby. Walkthrough will take place Wednesday August 12th at 9:00 a.m. eastern time.
MANDATORY (Check box if Mandatory)
LEIN CHECK (Dept. of Corrections ONLY) All contractor/vendor representatives attending a Pre-Bid Walk Through Meeting must submit a Vendor/Contractor LEIN Request five business days prior to the meeting date, (See the attached Vendor/Contractor LEIN Request form). Send the LEIN Request form, filled out and signed, by email to Daniel T. Smith & Sharon Frost at email addresses: SmithD76@michigan.gov & FrostS1@michigan.gov .The email “Subject” must include (Facility Name, Project Name, Date & Time of Pre-Bid Walk Through Meeting).
NOTE: An individual is only permitted to represent one bidder at a mandatory walk-through.
PROJECT DESCRIPTION/SERVICES REQUESTED:
This project consists of the design for the replacement of the ceiling within the food service building at Ionia Correctional Facility. The existing ACT ceiling is past expected life and has suffered significant wear and damage. Proposing firms will be responsible for design of the ceiling replacement and repair / configuration of the fire suppression and alarm systems, and replacement of light fixtures. Firms should evaluate the existing ceiling to determine if a plenum space is required and otherwise raise ceiling height to maximize clearance below.
Please NOTE:
• Proposal responses MUST be uploaded to SIGMA VSS.
https://sigma.michigan.gov/webapp/PRDVSS1X1/Advantage4
• Please enter the total cost for all phases as the bid amount.
• Firms are encouraged to combine their technical and cost proposals into one (1) attachment for proposal submission.
• Please remember that attachments can be no larger than 25mb.
mailto:SmithD76@michigan.gov mailto:FrostS1@michigan.gov https://sigma.michigan.gov/webapp/PRDVSS1X1/Advantage4
• Do not wait until just before the 2:00 p.m. solicitation deadline to submit your proposal response.
SIGMA VSS will not allow a proposal to be submitted after 2:00 p.m., even if a portion of the proposal response has been uploaded.
• If you experience issues or have questions regarding your electronic submission, you must contact the SIGMA Help Desk for assistance prior to the 2:00 p.m., solicitation deadline. You may contact the SIGMA Help Desk by telephone at 517.284.0540 or toll-free at 888.734.9749. You may also email the SIGMA Help Desk at sigma-procurement-helpdesk@michigan.gov
• Please email the Design and Construction Contract Specialists if you are having SIGMA VSS issues. Please include your SIGMA ticket number and any supporting documentation (i.e., screenshots) to Anne Watros (WatrosA@michigan.gov) and Don Klein (KleinD4@michigan.gov).
• You may be asked by our contract specialists to email your proposal. Emailed submissions will require DCD approval and will be handled on a case-by-case basis.
• Approved emailed submissions MUST be received prior to 2:00 p.m. deadline to be considered responsive and responsible.
• Responses should not be emailed to the Project Director.
NIGP CODES
90607, 90610, 90630, 90638, 90658, 92507, 92539, 92567
DESIRED SCHEDULE OF WORK
TBD, coordinated with design professional
ACCEPTING RFP QUESTIONS UNTIL:
Please do not submit online questions via SIGMA VSS. ALL questions should be emailed to Jared Gavin- Helfrich at gavinhelfrichj@michigan.gov address no later than 2:00 p.m., Eastern on Thursday August 20th, 2026.
REFERENCE STANDARDS: This project will comply with all codes, standards, regulations, and workers' safety rules that are administered by federal agencies (EPA, OSHA, and DOT), state agencies (DCH, EGLE, DNR, and MIOSHA), and any other local regulations and standards that may apply.
This form is required to be a part of the professional service contract. (Authority: 1984 PA 431) Attachment(s) mailto:sigma-procurement-helpdesk@michigan.gov mailto:WatrosA@michigan.gov mailto:KleinD4@michigan.gov mailto:gavinhelfrichj@michigan.gov