Project CM19183003 PID.rtf
RTF text file 41 KB Posted
- Attached to
- Swithchs, Relays, Contactors
- Solicitation number
- SPE7MX20R0104
Text of this file
*** LTC PID Packaging Consolidated Text *** PLEASE SEE GLOSSARY AT THE END OF THE DOCUMENT FOR FULL TEXT OF THE ITEM DESCRIPTION
AND PACKAGING REFERENCE NUMBERS CALLED OUT FOR EACH NSN.
NSN:002598810
SWITCH, SENSITIVE
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RQ032
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ002
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:CS240
REFERENCE NUMBER:CS241
REFERENCE NUMBER:CS199
REFERENCE NUMBER:ZD025
CRITICAL APPLICATION ITEM
IAW BASIC DRAWING NR 80020 91635
REVISION NR 28 DTD 05/03/2012
PART PIECE NUMBER: 91635-1
PREP FOR DELIVERY
LINE ITEM 00001 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:F
UNIT CONT:D3 OPI:O
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:00 -00 No special marking
REFERENCE NUMBER:IP025
NSN:011131623
SWITCH, SENSITIVE
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RC001
REFERENCE NUMBER:RP001
REFERENCE NUMBER:IP025
REFERENCE NUMBER:RQ002
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:E0116
REFERENCE NUMBER:ZD025
CRITICAL APPLICATION ITEM
DRS Naval Power Systems, Inc 27192 P/N 6984ED77-1
LINE ITEM 00002 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:31 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:00 CUSH/DUNN THKNESS:A
UNIT CONT:D3 OPI:M
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:IP025
NSN:005676264
RELAY, SUBASSEMBLY
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:E0042
DRS Naval Power Systems, Inc 27192 P/N 6957ED14-2A
LINE ITEM 00003 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:B
UNIT CONT:E5 OPI:M
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:ZD009
NSN:008375279
RELAY, THERMAL
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:E0042
DRS Naval Power Systems, Inc 27192 P/N 6957ED14-6A
LINE ITEM 00004 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:B
UNIT CONT:D3 OPI:M
INTRMDTE CONT:D3 INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:ZD009
NSN:009363932
RELAY, ELECTROMAGNETIC
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ002
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:ZD025
REFERENCE NUMBER:CS241
REFERENCE NUMBER:CS199
DRS Naval Power Systems, Inc 27192 P/N 6938ED37-1A
LINE ITEM 00005 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:D
UNIT CONT:D3 OPI:M
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:ZD009
Fragile item, handle with care.
NSN:011167877
RELAY, ELECTROMAGNETIC
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:ZD025
REFERENCE NUMBER:CS241
REFERENCE NUMBER:CS199
DRS Naval Power Systems, Inc 27192 P/N 6957ED25-4C
LINE ITEM 00006 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:C
UNIT CONT:E5 OPI:M
INTRMDTE CONT:E5 INTRMDTE CONT QTY:008
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:ZD009
Fragile item, handle with care.
REFERENCE NUMBER:ZD009
NSN:012187043
RELAY, THERMAL
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:CA061
DRS Naval Power Systems, Inc 27192 P/N 6957ED14-3A
LINE ITEM 00007 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:B
UNIT CONT:D3 OPI:M
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
REFERENCE NUMBER:ZD009
REFERENCE NUMBER:ZD009
NSN:013525850
RELAY, ELECTROMAGNETIC
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:ZD080
DRS Naval Power Systems, Inc 27192 P/N 6957ED59-2C DRS Naval Power Systems, Inc 27192 P/N 6962ED3015 PC 2-1
LINE ITEM 00008 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:A
UNIT CONT:D3 OPI:M
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:ZD009
REFERENCE NUMBER:ZD009
NSN:014690299
RELAY, ELECTROMAGNET
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
DRS Naval Power Systems, Inc 27192 P/N 6957ED104-A2ATN DRS Naval Power Systems, Inc 27192 P/N 6967ED531PC5A
LINE ITEM 00009 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:41 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:C
UNIT CONT:E5 OPI:M
INTRMDTE CONT:E5 INTRMDTE CONT QTY:016
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
REFERENCE NUMBER:ZD009
REFERENCE NUMBER:ZD009
NSN:010166247
CONTACTOR, MAGNETIC
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RD002
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
REFERENCE NUMBER:ZD025
REFERENCE NUMBER:CS199
DRS Naval Power Systems, Inc 27192 P/N 6957ED31-2C
LINE ITEM 00010 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:JC CUSH/DUNN THKNESS:D
UNIT CONT:E5 OPI:O
INTRMDTE CONT:E8 INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
NSN:013654282
CONTACTOR, MAGNETIC
REFERENCE NUMBER:RP001
REFERENCE NUMBER:RA001
REFERENCE NUMBER:RQ011
DRS Naval Power Systems, Inc 27192 P/N 6957ED66-3A
LINE ITEM 00011 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:A
UNIT CONT:E5 OPI:M
INTRMDTE CONT:D3 INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
GLOSSARY
PACKAGING TEXT
THE FOLLOWING PARAGRAPH APPLIES TO ALL PACKAGING CALLED OUT IN THIS DOCUMENT:
ITEM DESCRIPTION TEXT
REFERENCE NUMBER RP001
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
REFERENCE NUMBER RQ032
RQ032: EXPORT CONTROL OF TECHNICAL DATA
This item has technical data some or all of which is subject to export-control of either the International Traffic in Arms regulations (ITAR) or the Export Administration Regulations (EAR), and cannot be exported without prior authorization from either the Department of State or the Department of Commerce. Export includes disclosure of technical data to foreign persons and nationals whether located in the United States or abroad. This requirement applies equally to foreign national employees and U.S. companies and their foreign subsidiaries. DFARS 252.225-7048 is applicable to this data.
The Defense Logistics Agency (DLA) limits distribution of export-control technical data to DLA contractors that have an approved US/Canada Joint Certification Program (JCP) certification, have completed the Introduction to Proper Handling of DOD Export-Controlled Technical Data Training and the DLA Export-Controlled Technical Data Questionnaire (both are available at the web address given below), and have been approved by the DLA controlling authority to access the export-controlled data. Instructions for obtaining access to the export-controlled data can be found at:
https://www.dla.mil/HQ/LogisticsOperations/EnhancedValidation/
To be eligible for award, offerors and any sources of supply proposed for use are required to have an approved JCP certification and have been approved by the DLA controlling authority to access export-controlled data managed by DLA. DLA will not delay award in order for an offeror or its supplier to apply for and receive approval by the DLA controlling authority to access the export-controlled data.
REFERENCE NUMBER RA001
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE
SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE
ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE
APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON
REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
REFERENCE NUMBER RQ002
RQ002: CONFIGURATION CHANGE MANAGEMENT - ENGINEERING CHANGE PROPOSAL
REQUEST FOR VARIANCE (DEVIATION OR WAIVER)
REFERENCE NUMBER RQ011
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
REFERENCE NUMBER CS240
NOTE: THIS IS A RESTRICTED SOURCE ITEM
MANUFACTURED TO THE OEM DRAWING(S) CITED
HEREIN AND AS OF THE DATE OF THIS SOLICITATION
ONLY THE SOURCE(S) CITED BELOW HAS/HAVE BEEN
PREQUALIFIED TO MANUFACTURE THE ITEM.
OFFERS BASED ON SUPPLYING OTHER MANUFACTURER'S
PARTS SHALL BE ACCOMPANIED BY TECHNICAL AND
OTHER DATA SUFFICIENT TO EVALUATE THE ITEM FOR
THE INTENDED APPLICATION AS PER DLAI 3200.1,
ENCL 6. SAID EVALUATION MAY TAKE AN EXTENDED
PERIOD OF TIME AND MAY THEREFORE BE APPLICABLE
TO FUTURE PROCUREMENTS. FINAL APPROVAL AUTHORITY
REST WITH THE GOVERNMENT DESIGN CONTROL
ACTIVITY.
REFERENCE NUMBER CS241
NOTE: THIS IS A RESTRICTED SOURCE ITEM AND
REQUIRES ENGINEERING SOURCE APPROVAL BY THE
GOVERNMENT DESIGN CONTROL ACTIVITY.
REFERENCE NUMBER CS199
ALTERNATE OFFEROR REQUIREMENTS:
THE FOLLOWING DOCUMENTATION IS REQUIRED IN
ACCORDANCE WITH MIL-T-31000. (A) ALL DRAWINGS
AND SPECIFICATIONS REQUIRED FOR MANUFACTURE.
(B) PROCESS/OPERATION SHEETS WHICH DESCRIBE
IN DETAIL EACH CRITICAL PROCESS AND ASSOCIATED
INSPECTION/ACCEPTANCE CRITERIA. (C)
IDENTIFICATION OF SOURCES WHO WILL PERFORM
CRITICAL PROCESSES/OPERATIONS, INCLUDING
SOURCES OF FORGINGS AND CASTINGS. (D) IF
AVAILABLE COPIES OF PURCHASE ORDERS FROM THE
ITEM. (E) A SHOCK EXTENSION REPORT IN
ACCORDANCE WITH MIL-S-901 AND IN A FORMAT AS
SPECIFIED IN DI-ENVR-80706 IS REQUIRED.
IF THE OEM'S DETAILED DRAWINGS ARE NOT
AVAILABLE, THE OFFEROR MUST SUPPLY AN
ENGINEERING ANALYSIS REPORT WHICH DETAILS HOW
THEIR DRAWINGS WERE DEVELOPED. ADDITIONALLY,
IF REVERSE ENGINEERING WAS USED, THE COMPLETE
PROCEDURE WILL BE REPORTED INCLUDING: NUMBER
OF SAMPLES, METHODS AND MEASURES USED, ALL DATA
COMPILED, RATIONALE FOR DIMENSION TOLERANCE
DEVIATION, AND RATIONALE FOR ACCEPTANCE. THIS
DATA WILL BE FORWARDED TO THE ENGINEERING
SUPPORT ACTIVITY FOR EVALUATION.
REFERENCE NUMBER ZD025
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO<(>,<)> OR COME IN DIRECT
CONTACT WITH<(>,<)> ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
REFERENCE NUMBER IP025
IP025: PACKAGING, MARKING, AND SHIPPING OF HAZARDOUS MATERIALS
REFERENCE NUMBER E0042
THIS IS A COMMERCIAL OFF-THE-SHELF ITEM.
REFERENCE NUMBER E0116
ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE
OFFERS IS NOT AVAILABLE AT THE PROCUREMENT
AGENCY. THE OFFEROR MUST PROVIDE A COMPLETE
DATA PACKAGE INCLUDING DATA FOR THE APPROVED
AND ALTERNATE PART FOR EVALUATION.
REFERENCE NUMBER ZD009
UNIT PACKAGE MARKING REQUIREMENT FOR COMPONENT LEAD FINISH
(a) In addition to all other marking requirements in this contract, the Contractor shall apply one of the assigned markings in accordance with paragraphs 5.3.1 and 5.3.2 of IPC/JEDEC J-STD-609, Marking and Labeling of Components, printed circuit boards (PCBs) and printed circuit board assemblies (PCBAs) to Identify Lead (Pb), Pb-Free and Other Attributes, to each individual unit pack of the item being acquired. Placement of the markings shall be in accordance with paragraph 6.1 of the standard.
(b) Copies of the current version of this standard may be purchased or downloaded from the Association Connecting Electronics Industry (IPC), http://www.ipc.org, or the Solid State Technology Association (JEDEC), http://www.jedec.org.
REFERENCE NUMBER RD002
RD002, COVERED DEFENSE INFORMATION APPLIES
REFERENCE NUMBER RC001
RC001: DOCUMENTATION REQUIREMENTS FOR SOURCE APPROVAL REQUEST (SAR)
REFERENCE NUMBER CA061
ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE
OFFERS IS NOT AVAILABLE AT THE PROCUREMENT
AGENCY.THE OFFEROR MUST PROVIDE A COMPLETE
DATA PACKAGE INCLUDING DATA FOR THE APPROVED
AND ALTERNATE PART FOR EVALUATION.
REFERENCE NUMBER ZD080
SAMPLING:
THE SAMPLING METHOD SHALL BE IN ACCORDANCE WITH MIL-STD-1916 OR ASQ
H1331, TABLE 1 OR A COMPARABLE ZERO BASED SAMPLING PLAN UNLESS OTHERWISE
SPECIFIED BY THE CONTRACT. IF THE APPLICABLE DRAWING, SPECIFICATION,
STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES CRITICAL, MAJOR
AND/OR MINOR ATTRIBUTES, THEY SHALL BE ASSIGNED VERIFICAITON LEVELS OF
VII, IV AND II OR AQLS OF 0.1, 1.0 AND 4.0 RESPECTIVELY. UNSPECIFIED
ATTRIBUTES SHALL BE CONSIDERED AS MAJOR UNLESS SAMPLING PLANS ARE
SPECIFIED IN APPLICABLE DOCUMENTS. FOR MIL-STD-1916, THE MANUFACTURER
MAY USE THE ATTRIBUTE OR VARIABLE INSPECTION METHOD AT THEIR OPTION OR
PER THE CONTRACT. MIL-STD-105/ASQ Z1.4 MAY BE USED TO SET SAMPLE LOT
SIZE, BUT ACCEPTANCE WOULD BE ZERO NON-CONFORMANCES IN THE SAMPLE LOT
UNLESS OTHERWISE SPECIFIED IN THE CONTRACT.