Statement of Objectives Physical Security For 154TH RTI Campus Camp Shelby, MS
Scope of Work:
Provide, Install, and integrate a physical security system throughout 10 buildings within the RTI campus. Physical Security contractor will provide exterior door locks and security key card access along with indoor and outdoor security cameras with software. Contractor will also provide computer, software, and printer in order to make access key cards for staff and students. End state is to limit access to authorized personal only and be able to monitor access point with cameras via network access from on site as well as off site. Remote access to security system is required. End user will be able to view camera, adjust settings, and control locks and profile changes remotely.
Physical Security Equipment by buildings
Building 3500- 7 Proximity Readers \ Security Door Controls. 7 indoor cameras
Building 3740- 2 Proximity Readers / Security Door Controls. 1 Outdoor Camera
Building 3701- 3 Proximity Readers / Security Door Controls. 3 Outdoor Cameras
Building 3703- 3 Proximity Readers / Security Door Controls
Building 3601- 4 Proximity Readers / Door Controls. 1 Outdoor Camera / 3 indoor Cameras
Building 1450- 3 Proximity Readers / Security Door Controls. 1 Outdoor Camera / 2 indoor cameras
Laundry Facility- 1 Proximity Reader / Security Door Control. 1 Outdoor Camera / 2 indoor camera
Building 3576- 3 Proximity Readers / Security Door Controls. 3 indoor Cameras / 1 outdoor camera (Barracks)
Building 3575- 5 Proximity Readers / Security Door Controls. 6 indoor Cameras
Building 3577- 2 Proximity Readers / Security Door Controls. 2 indoor cameras.
| PERFORMANCE LOCATION: | 154th RTI Campus | |
| Camp Shelby Joint Forces Training Center | ||
| Camp Shelby, MS |
Security Requirements:
Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.
Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014-05/AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.
The contractor and all associated sub-contractors shall brief all employees on the local iWATCH program (training standards provided by the requiring activity ATO). This local developed training will be used to inform employees of the types of behavior to watch for and instruct employees to report suspicious activity to the COR. This training shall be completed within 30 calendar days of contract award and within 10 calendar days of new employees commencing performance with the results reported to the COR NLT 30 calendar days after contract award.