S_Series_Spec_Sheet.pdf
PDF 382 KB Posted
- Solicitation number
- NWWG0000-19-00302
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MODEL S10 S20 S40
On-site hydrogen generator in an integrated, automated, site-ready enclosure Load following operation automatically adjusts output to match demand
Full differential Pressure, H2 over O2
ELECTROLYTE
Proton Exchange Membrane (PEM) – Caustic-Free
HYDROGEN PRODUCTION
Nominal Production Rate Nm3/hr @ 0°C, 1 bar SCF/hr @ 70°F, 1 atm SLPM @ 70°F, 1 atm kg per 24 hours
0.27 Nm3/hr
10 SCF/hr
4.8 SLPM
0.58 kg/24hr
0.53 Nm3/hr
20 SCF/hr
9.4 SLPM
1.14 kg/24hr
1.05 Nm3/hr
40 SCF/hr
18.8 SLPM
2.27 kg/24hr
Delivery Pressure – Nominal 13.8 barg (200 psig)
Power Consumption by System per Volume of H2 Gas Produced1 6.1 kWh/Nm3 (16.3 kWh/100 ft3)
Purity (Concentration of Impurities) 99.9995% [H2O < 5 ppm, -65oC (-85oF) Dew Point, N2 < 2 ppm, O2 < 1 ppm, all other undetectable]
Turndown Range 0-100% net product delivery (automatic)
Upgradeability N/A
DI WATER REQUIREMENT
Consumption Rate at Maximum Production
0.26 L/hr
(0.08 gal/hr)
0. 47 L/hr (0.13 gal/hr)
(0.94 L/hr) (0.25 gal/hr)
Temperature 5-35°C (41-95°F)
Pressure 1.5-4 barg (21.8-58 psig)
Input Water Quality Required: ASTM Type II Deionized Water, < 1µS/cm (> 1 MΩ-cm) Preferred: ASTM Type I Deionized Water, < 0.1 µS/cm (> 10 MΩ-cm)
HEAT LOAD AND COOLANT REQUIREMENT
Coolant Air-cooled; ambient air
Maximum Heat Load 1.1 kW 3,754 BTU/hr
2.2 kW 7,507 BTU/hr
4.3 kW 14,673 BTU/hr
ELECTRICAL SPECIFICATIONS
Maximum Power Required within Expected System Life 3 kVA 4.5 kVA 8.5 kVA
Electrical Requirements 208-240 VAC, single phase, 50 or 60 Hz
S Series Hydrogen Generation Systems
Model S10 S20 S40
INTERFACE CONNECTIONS – CONSULT INSTALLATION MANUAL FOR DETAILS
H2 Product Port 1/4” CPITM compression tube fitting, SS
H2/H2O Vent Port 1/2” CPITM compression tube fitting, SS
O2 Vent Port 3/8” FNPT
DI Water Port 1/4” tube push-to-lock, polypropylene
Drain Port 1/4” tube push-to-lock polypropylene
Electrical Connect to on-board circuit breaker
Communications Ethernet, 24 VDC dry contacts
CONTROL SYSTEMS
Standard Features
• Fully automated, push button start/stop
• Automatic fault detection and system depressurization
• E-stop
• Remote start/stop
• On-board H2 leak detection
• Remote communications
Remote Shutdown Hardwire input to safety PLC
PHYSICAL CHARACTERISTICS
Dimensions W x D x H
Product Est. Shipping
79 cm x 97 cm x 112 cm (31” x 38” x 44”) 97 cm x 114 cm x 137 cm (38” x 45” x 54”)
Weight Product Est. Shipping
209 kg (460 lbs) 289 kg (635 lbs)
IP Rating IP 22
ENVIRONMENTAL CONSIDERATIONS – DO NOT FREEZE
Standard Siting Location Indoor, level ± 1°, 0-90% RH non-condensing, non-hazardous/non-classified environment
Storage/Transport Temperature 5-60°C (41-140°F)
Ambient Temperature Range 5-40°C (41-104°F);
Optional: 5-50°C (41-122°F) 5-40°C (41-104°F)
Altitude Range – Sea Level 1,520 m (5,000 ft)
Ventilation Proper ventilation must be provided from a non-hazardous area, at a rate in accordance with IEC60079-10, Zone 2 NE
SAFETY AND REGULATORY CONFORMITY
Maximum On-board H2 Inventory at Full Production
0.016 Nm3
0.56 SCF
0.001 kg
Cabinet Ventilation with Environment
NFPA 69 and EN 1127-1, Clause 6.2 Vent fan draws fresh air up to 28 Nm3/min (1,000 ft3/min)
Noise dB(A) at 1 Meter < 70
Conformity cTUVus (UL and CSA equivalent), CE (PED, Mach. Dir., EMC), ISO 22734-1
PD-0600-0061 Rev F© 2019 Nel ASA. All Rights Reserved. Nel, number one by nature, Proton, and the Nel and Proton logos are trademarks of Nel ASA or its subsidiaries.
www.nelhydrogen.com | +1.203.949.8697 | info@nelhydrogen.com MADE IN USA
Specifications are subject to change. Please contact Nel Hydrogen for solutions to best fit your needs.
1 Dependent on configuration and operating conditions. Certified to
ISO 9001:2015
File details come from the government source that posted it.