NMAN7200-19-00340 Questions and Answers Q1: I am assuming that both 4000M pieces are continuous?
A1: Yes, (2ea) 4000M continuous pieces.
Q2: When it says DYFORM, is this referring to compacted strands or is this just a regular 6X26 with a fiber core?
A2: Compacted strands.
Q3: Are lays Right Regular Lay and Left Regular Lay?
A3: Yes, Right Regular Lay and Left Regular Lay.
Q4: Could you please advise the diameter required?
A4: 1-1/8” (28.6mm) diameter.
Q5: Would you be able to provide us with certs or drawings?
A5: It is the responsibility of the contractor to provide NOAA the certifications and drawings. The wire rope to be manufactured in accordance with ISO 17893 or equivalent.
Q6: What type of dyform is required?
A6: 6 x 26 (6 x 19 class) “star fish,” dy-formed (compacted), wire core, galvanized, standard lube.
Q7: Per the statement of need "6X26 FC". To me this means a Fiber Core, is this correct? Or is the core steel, "IWRC" (Independent Wire Rope Core)?
A7: The statement of need has been amended to list IWRC.