Solicitation QA.pdf

PDF 64 KB Posted

Attached to
New World Primates Caging Systems Federal contract opportunity
Solicitation number
NIHOD75N008031Q0001
Issued by
Department of Health and Human Services National Institutes of Health Office of Logisitics and Acquisition Operations

About this file

This document is a request for quotes for a new world primate caging system. The National Institutes of Health Office of Logistics and Acquisition Operations is seeking quotes for 112 new world primate caging systems. Interested vendors should submit quotes by September 22, 2022 at 10:00 AM Eastern Time referencing solicitation number NIHOD75N008031Q0001. Quotes should be no longer than 10 pages and include the vendor's capability statement, past performance experience, point of contact information, and UEI number. Questions regarding this request for quotes are due by September 16, 2022 at 4:30 PM Eastern Time. This is a small business set-aside competition with a NAICS code of 332618 and 332999 and size standard of 750 employees.

View the file

Other files for this federal contract opportunity

Other files attached to New World Primates Caging Systems, newest first.
File Type Posted
TECHNICAL-EVALUATION-CRITERIA-Numerical-Rating (2).pdf PDF
SOW Aotus Cage System.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Please see questions for NIHOD75N008031Q0001 below and respond:

1. Material preference for the top, sides and back of the unit? Stainless steel.

2. Is there a specific diameter and spacing of wire required/desired? Diameter should be appropriate for the species. Spacing between bars NTE .50” to prevent escape of Aotus adults and offspring.

3. What is required for adjacent unit to unit access/socialization (solid/mesh/clear panel, etc.)

Solid.

4. Would an O/A of 80-1/16” be acceptable? The spec’d height of 79” with an animal height of 34” and 5” diameter casters make for shallow waste pans. Overall height cannot exceed 79.25” or cages will not roll into rooms. Door height above finished floor is the limiting factor.

5. Should vertical sliding doors in swing door be like the marmoset units? Specifications call out vertical sliding doors.

6. Will metal waste pans be accepted? Metal waste pans will be considered.