NC NP BLRI 2A16_BIP_Report_5140-081P.pdf
PDF 4 MB Posted
- Attached to
- Blue Ridge Parkway Federal contract opportunity
- Solicitation number
- 693C73-23-B-000013
About this file
This bridge inspection report details the condition of Brush Creek Bridge #1, structure number 5140-081P, on the Blue Ridge Parkway over Brush Creek in North Carolina. The 68-foot long concrete bridge consists of two spans and was constructed in 1936. Deficiencies noted include cracking and efflorescence on the concrete undersides, longitudinal cracking in the wearing surface, and scour holes around piers and abutments. Recommended improvements include rehabilitation and reconstruction of the bridge, which is scheduled for replacement under Project BLRI 2A16. The related federal contract opportunity is a solicitation from the Department of Transportation Federal Highway Administration to replace this bridge as part of the Blue Ridge Parkway project.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Results of Bid Opening - NC NP BLRI 2A16.pdf | ||
| Amendment 0004 - Project NC NP BLRI 2A16.pdf | ||
| Amendment 0003 - Project NC NP BLRI 2A16.pdf | ||
| Amendment 0002 - Project NC NP BLRI 2A16.pdf | ||
| Amendment 0001 - Project NC NP BLRI 2A16.pdf | ||
| Report No. 17-03 - BLRI 2A16S.pdf | ||
| ADV_Bidders Qualifications Form.doc | DOC document | |
| Plans - NC NP BLRI 2A16.pdf | ||
| IFB Solicitation - NC NP BLRI 2A16.pdf | ||
| FP14_Eng.pdf | ||
| NC NP BLRI 2A16_BIP_Report_5140-077P.pdf | ||
| VETS-4212 Form.pdf | ||
| NC NP BLRI 2A16_Scour_Analysis_Report_Amended.pdf | ||
| NC NP BLRI 2A16_BIP_Report_5140-080P.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRIDGE INSPECTION REPORT
BRUSH CREEK BRIDGE #1
BLUE RIDGE PARKWAY OVER BRUSH CREEK
BLUE RIDGE PARKWAY
LOOKING NORTH
STRUCTURE NO. 5140-081P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 6/24/2021
WEST (DOWNSTREAM) SIDE
Report prepared by:
Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 5140-081P
BRUSH CREEK BRIDGE #1 INSPECTION DATE: 06/24/2021
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-081P
BRUSH CREEK BRIDGE #1 INSPECTION DATE : 06/24/2021
PRIORITY OF IMPROVEMENT226
A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
B
Item No.
Maintenance Recommendations
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT UNIT
COST
PRELIM.
COST
ESTIMATE
PRELIM. MAINTENANCE TOTAL :
Item No.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST
PRELIM. COST ESTIMATES
REHAB RECONSTR
58,59,60 REPLACE STRUCTURE.
1 LS
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL :
PRELIM. REHABILITATION TOTAL :
PRELIM. RECONSTRUCTION TOTAL : .
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL * :
(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)
Remarks : Bridge is scheduled for replacement in the near future under Project BLRI 2A16.
STRUCTURE LOAD RATING STRUCTURE NO. 5140-081P
BRUSH CREEK BRIDGE #1 INSPECTION DATE: 06/23/2021
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 16 15 27 24
HS 25 23 42 38
TYPE 3 21 19 36 33
TYPE 3S2 33 30 55 50
TYPE 3-3 42 38 70 64
DESIGN LOADING: 2 - H 15
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 06/01/2019
LOAD RATING CONTROLLED BY: POSITIVE MOMENT
REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.
SEE BRIDGE FILE FOR LOAD RATING CALCULATIONS.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-081P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY
(202) STRUCTURE NAME:..............BRUSH CREEK BRIDGE #1
(203) STRUCTURE KIND:............... 1 - BRIDGE
(204) STRUCTURE NUMBER:.........5140-081 P
4 - SOUTHEAST(205) NPS REGION:
(206) ROUTE CODE NUMBER:
(207) ROAD SECTION NO:
(208) NPS ROAD CLASS:............... 1 - PRINCIPAL PARK ROAD
(209) WITHIN NPS BNDRY?:.......... Yes
(210) OPERATING UNIT:.................BLUFFS
(211) PROJECT NO(S):................... 2A2
(212) DRAWING NUMBERS:...........NONE
(21) MAINTAINED BY:......................66 - NATIONAL PARK SERVICE
(22) OWNER:................................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY / PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR:
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORIC DESIGNATION:
374 - NORTH CAROLINA
37005 ALLEGHANY
00000
1 6 1 00001 0
BRUSH CREEK
BLUE RIDGE PARKWAY
5140081P0000000
2 0 MILES FROM U.S. ROUTE 21
99.99 FT ( 99.99 M)
227.4 (KM PT: 69.33)
3 - ON FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL:..........2 - CONCRETE CONTINUOUS (44A) APPR. STR. MATERIAL:............ 0 - Other
(43B) MAIN STR. TYPE:.................. 04 - TEE BEAM (44B) APPR. STR. TYPE:.................... 00 - OTHER
(45) NO. OF MAIN SPANS:..............002 (46) NO OF APPROACH SPANS:
(48) MAX. SPAN LENGTH:..............34 FT ( 10.4 M)
(49) STRUCTURE LENGTH:........... 68.0 FT ( 20.7 M) (108) WEAR SURFACE/PROTECT SYSTEM:
(216A) ABUTMENT #1 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L A) TYPE WEARING SURFACE:.. 6 - BITUMINOUS
(216B) ABUTMENT #2 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L B) TYPE MEMBRANE:................. 0 - NONE
(217A) PREDOM. PIER FDN:.......... 2 - SPREAD FTG ON BEARING MAT'L C) TYPE PROTECTION:.............. 0 - NONE
(217B) SECOND. PIER FDN:.......... 6 - N/A (218) IS SALT USED?.......................... YES
(107) DECK TYPE:.......................... 1 - CONCRETE CAST-IN-PLACE
LOAD RATING AND POSTING
(31) DESIGN LOAD:.........................2 - H 15 (41) LOAD RESTRICTION:.................. A - OPEN
(66) INVENTORY RATING:..............22.5 TONS ( 20.4 METRIC TONS) (70) BRIDGE POSTING:...................... 5 - EQUAL TO OR ABOVE LEGAL
LOADS
(64) OPERATING RATING:..............37.6 TONS ( 34.1 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 06/24/2021 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: Y - 1 - DECK SURVEY (A) FRACTURE CRITICAL:.......... N
(220) SPECIAL STUDY TYPE: 0 - NONE INSP. EVERY MONTHS - LAST INSP:
(221) SPECIAL STUDY DATE: (B) UNDERWATER:..................... N
INSP. EVERY MONTHS - LAST INSP:
(C) SPECIAL INSPECTION:........ N
INSP. EVERY MONTHS - LAST INSP:
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-081P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE:................................ 36° 27'40 02" (51) CURB TO CURB WIDTH:............ 29.5 FT ( 9 M)
(17) LONGITUDE:............................ 81°00 '01 32" (52) DECK WIDTH:.......................... 34.5 FT ( 10.5 M)
(19) DETOUR LENGTH:.................. 25 MI ( 40 KM) (32) APPR. ROADWAY WIDTH:...... 28.0 FT ( 8.5 M)
(28A) LANES ON STRUCT:.............02 (213) APPR. PAVEMENT WIDTH:... 20.0 FT ( 6.1 M)
(28B) LANES UNDER STRUCT:......00 LEFT SHOULDER:............... 4 0 FT ( 1.2 M)
(42A) SERVICE ON:.........................1 - HIGHWAY RIGHT SHOULDER:.......... 4 0 FT ( 1.2 M)
(42B) SERVICE UNDER:................. 5 - WATERWAY (33) BRIDGE MEDIAN:.................... 0 - NO MEDIAN
(29) AVG DAILY TRAFFIC:..............1347 (34) SKEW ANGLE:......................... 15 °
(30) YEAR OF ADT:......................... 2013 (35) STRUCTURE FLARED:............ 0 - NO FLARE
(114) FUTURE ADT:.........................1482 (47) TOTAL HORIZ. CLEARANCE:.. 31.7 FT ( 9.7 M)
(115) YEAR OF FUTURE ADT:........2033 (50) SIDEWALKS
(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 0 0 FT ( 0 M)
(38) NAVIGATION CONTROL:.........0 - NO NAVIGATION CONTROL ON RIGHT:.................................. 0 0 FT ( 0 M)
WATERWAY (BRIDGE PERMIT NOT
REQUIRED)
(39) VERTICAL CLEARANCE:.........0 FT ( 0 M) (214) BRIDGE RAIL TYPE
1 - FULL HEIGHT (NO PARAPET)(40) HORIZ. CLEARANCE:..............0 FT ( 0 M) RAIL CONFIGURATION:
(111) ABUT OR PIER PROT:........... MATERIAL:........................... 7 - T MBER
LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 3 - SIMPLE RAIL (JOINTS AT EACH
POST)
(55) RIGHT:...............................00 FT ( 0 M) (215) BRIDGE RAIL HEIGHT:.......... 1 58 FT ( 0.48 M)
(56) LEFT:................................ 0 FT ( 0 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)
(54) MIN. VRT. UNDRCLRANCE:... .00 FT ( 0 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:....................................... 4 (67) STRUCTURAL EVALUATION:
(59) SUPERSTRUCTURE:...............6 (68) DECK GEOMETRY:
(60) SUBSTRUCTURE:.......... 7 (69) UNDERCLEARANCES:................ N
(61) CHANNEL:................................7 (71) WATERWAY ADEQUACY:
(62) CULVERT:.................................N (72) APPROACH ALIGNMENT:
(222) APPROACHES:...................... 7 (113) SCOUR CRITICAL:.................... 4 - ACTION IS REQUIRED TO
PROTECT EXPOSED FOUNDATIONS
(223) RETAINING WALL:.................N (225) PURPOSE OF IMPROVEMENT: 2 - REHAB/RECONSTRUCTION
(36) TRAFFIC SAFETY FEAT: 0 N 0 N (226) PRIORITY OF IMPROVEMENT: B - MAJOR
(75A) TYPE OF WORK:................... (227) MAINTENANCE COST:
(75B) WORK DONE BY:.................. (228) REHAB / RECNSTR COST:
(76) IMPROVEMENT LENGTH:....... FT ( 0 M) (229) CONSTRUCTION COST:
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1983-JOINT REPAIR.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIGURATION INFORMATION:
Inspector: Reinaldo Silvestry Structure Number: 5140081P0000000
Inspection Date: 06/24/2021 Facility Carried: BLUE RIDGE PARKWAY
Bridge Inspection Report
Pictures
PHOTO 3
Description LOOKING SOUTH TOWARD BLOWING ROCK
PHOTO 4
Description EAST (UPSTREAM) SIDE
Bridge Inspection Report
Pictures
PHOTO 5
Description GENERAL TOPSIDE VIEW LOOKING SOUTH
PHOTO 6
Description FULL WIDTH TRANSVERSE CRACK IN WEARING SURFACE AT NORTH APPROACH
Bridge Inspection Report
Pictures
PHOTO 7
Description BROKEN PAVEMENT WITH UNDERMINING AT SOUTHWEST APPROACH
PHOTO 8
Description GENERAL VIEW OF EAST TIMBER RAILING
Bridge Inspection Report
Pictures
PHOTO 9
Description VEGETATION GROWTH ALONG WEST RAIL
PHOTO 10
Description SOUTHWEST WINGWALL
Bridge Inspection Report
Pictures
PHOTO 11
Description SOUTHEAST WINGWALL; NOTE MOSS AND VEGETATION GROWTH
PHOTO 12
Description SOUTH ABUTMENT
Bridge Inspection Report
Pictures
PHOTO 13
Description SCOUR HOLE, 2FT DEEP, NEAR CENTER OF SOUTH ABUTMENT; NO UNDERMINING
OBSERVED
PHOTO 14
Description SCOUR HOLE ON EAST SIDE OF SOUTH ABUTMENT
Bridge Inspection Report
Pictures
PHOTO 15
Description UNDERSIDE VIEW OF SOUTH SPAN LOOKING WEST
PHOTO 16
Description GENERAL VIEW OF SOUTH FACE OF PIER
Bridge Inspection Report
Pictures
PHOTO 17
Description SCOUR HOLE ON EAST END OF SOUTH FACE OF PIER
PHOTO 18
Description GENERAL VIEW OF NORTH FACE OF PIER
Bridge Inspection Report
Pictures
PHOTO 19
Description UNDERSIDE VIEW OF NORTH SPAN LOOKING NORTH
PHOTO 20
Description LONGITUDINAL CRACK WITH EFFLORESCENCE ALONG UNDERSIDE OF WEST
OVERHANG ON NORTH SPAN
Bridge Inspection Report
Pictures
PHOTO 21
Description LONGITUDINAL CRACK WITH EFFLORESCENCE ALONG UNDERSIDE OF EAST OVERHANG
ON NORTH SPAN
PHOTO 22
Description NORTH ABUTMENT; NOTE EFFLORESCENCE FROM MORTAR JOINTS
Bridge Inspection Report
Pictures
PHOTO 23
Description NORTHEAST WINGWALL
PHOTO 24
Description LOOKING UPSTREAM
Bridge Inspection Report
Pictures
PHOTO 25
Description LOOKING DOWNSTREAM