Nashville Pharmacy Compounding Space Room Layout.pdf
PDF 317 KB Posted
- Attached to
- Q301--BI-ANNUAL CERTIFICATION AND MONTHLY PHARMACY STERILE SAMPLING Federal contract opportunity
- Solicitation number
- 36C24920Q0426
About this file
This solicitation requests quotations for bi-annual certification and monthly viable surface and air sampling services for sterile compounding areas at two Department of Veterans Affairs medical centers in Tennessee. Services include bi-annual certification of primary and secondary engineering controls in accordance with CETA guidelines, including viable air and surface sampling with identification of colony forming units. Monthly services encompass environmental sampling at both locations. Quotations should provide unit costs for each test and service for the base year and four option years. The anticipated period of performance is from October 2020 to September 2025. Quotes are due by September 18, 2020 and must be submitted via email. Award will be made to the lowest priced offer meeting the solicitation's terms and conditions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C248920Q0426 Lineitems.xlsx | XLSX spreadsheet | |
| 36C24920Q0426.docx | DOCX document | |
| Nashville Pharmacy Compounding Space RCP.pdf | ||
| 01-18-262_Arch_FCD 4.pdf | ||
| 01-18-262_Arch_FCD 7.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
LA
R
E GI H,N
C
N
E
D
M RU
P
Y
N O
R
T H C A R O L
I N A
NY
H
M
RE
G
IS
TERED ARCHITECT
R E
F
R E
F
REF.
R E
F
OUTPATIENT
FILLING/ASSEMBLY
C1-21B
A-402
A-402 910
A-402
6'-10 1/2"
11'-11"
PHASE 1 PHASE 2
A-401
A-401
8A-401
A-401
A-40117
A-4021
A-402
HAC
HAC
HOOD HOOD
HOOD
HOODHOOD
HOOD HOOD
/2
/2
19'-10"
/2
/2
D
E
F
161514 17 18
PRO TECH
1-G134J
ELECTRICAL
CLOSET
G-104
DATA
G-103
VAULT
1-G134I
CORRIDOR
C1-21A
CORRIDOR
C1-21
02 02
8"
1'-8"
2'-0" 1'-0"
1'-0"
10"
7'-9 1/2" 11'-0"
7'-11" 5"
11'-4"
10'-4" 14'-5" 1'-0"
3'-11 1/2"
/2
3'-0 1/2"
/2
/2
2'-7"
PASS
THRU
(EXHAUSTED
TO EXT.)
PASS
THRU
(FILTERED)
PASS
THRU
(FILTERED)
PASS
THRU
(FILTERED)
MALE
TOILET
G-108
HD PREP
C1-32
FEMALE
TOILET
G-106
PHARMACISITS
PROCESSING
AREA
1-G134A
IV
STORAGE
G-107K
HD
STORAGE
CORRIDOR
G-107L
HD
STORAGE
G-107
HD
BUFFER
G-107C
BCG
G-107B
BCG
COUNTER
G-107D
HD
ANTEROOM
G-107A
HD
COUNTER
G-107E
NON-STERILE
COMPOUNDING
1-G134D
SUPERVISOR
OFFICE
G-107J
I.P.
SUPER
1-G134F
IV
SET-UP
G-107I
IV PREP
G-107H
IV PREP
G-107G
IV
ANTEROOM
G-107F
PHASE 3
# INDICATES PARTITION TYPES - SEE A-502
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
EXISTING 1 HR - SMOKE WALL
NEW 1 HR - SMOKE WALL
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:1
P
M
A-101
FIRST FLOOR PLAN
9 18DMM EGS
USP 800 PHARMACY
COMPLIANCE
1310 24th AVE S, NASHVILLE, TN 37212
05/14/2019
FINAL CONSTRUCTION DOCUMENTS
626-18-50118-263
Scale: 1/4" = 1'-0"
FIRST FLOOR PLAN
0 4 8 16
NORTH
PLAN
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A. REFER TO MECHANICAL, ELECTRICAL, PLUMBING,
AND FIRE PROTECTION DRAWINGS FOR
ADDITIONAL WORK AND NOTES.
B. PROVIDE/INSTALL NEW METAL STUD WALLS,
PARTITIONS, AND/OR FURRING AS DESIGNATED.
REFER TO PARTITION TYPES AND DETAILS.
C. FOR WALLS AND OTHER ITEMS THAT ARE TO
REMAIN (WITHIN THE LIMITS OF THE PHARMACY)
REPAINT OR PROVIDE FINISHES TO MATCH
ADJACENT FINISHES. REPAINT WINDOW AND DOOR
TRIMS/FRAMES. REPLACE BASE AS REQUIRED --
SEE FINISH SCHEDULE REPAINT/PATCH HOLES.
D. REFER TO SHEETS A-501, A-502, AND A-602 FOR
WALL TYPES AND PLAN DETAILS.
E. WHERE MECHANICAL DUCTS/PENETRATIONS
AND/OR EQUIPMENT, ETC. ARE BEING REMOVED,
REPLACED, RELOCATED, AND/OR RESIZED,
PROVIDE NEW SEALS AND FLASHING AS
NECESSARY. PATCH HOLES RESULTING FROM THE
REMOVAL OF THIS EQUIPMENT. COORDINATE
COATING WITH MECHANICAL DRAWINGS.
F. PATCH CONCRETE FLOOR AFFECTED BY THE
REMOVAL OF EXISTING WALLS AND OTHER ITEMS.
CLEAN AND PREPARE TO RECEIVE NEW FLOOR
FINISH -- SEE SCHEDULE.
G. PROVIDE NECESSARY BLOCKING AND
REINFORCEMENTS FOR CABINETS, ACCESSORIES,
ETC.
PARTITION TYPES
DocuSign Envelope ID: 60A5663F-46E3-4E72-8918-25FE3C19448B
5/14/2019
File details come from the government source that posted it. Updated .