Bldg_20291_Room_103_SOW.pdf

PDF 374 KB Posted

Attached to
Security System Federal contract opportunity
Solicitation number
N6893617T0042
Issued by
Department of the Navy Naval Air Systems Command Naval Air Warfare Center

About this file

Bldg 20291 Room 103 SOW

View the file

Other files for this federal contract opportunity

Other files attached to Security System, newest first.
File Type Posted
Q&A.docx DOCX document
17-T-0042_RFQ_Amendment_2.docx DOCX document
17-T-0042_RFQ_Amendment.docx DOCX document
Bldg_20279_Room_218_SOW.pdf PDF
Bldg_20212_SOW.pdf PDF
Bldg_20303_Room_209_SOW.pdf PDF
17-T-0042_RFQ_Solicitation.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK FOR THE

ACCESS CONTROL FOR BUILDING

20291 ROOM 103 LOCATED AT CHINA LAKE.

Background:

The purpose of this project is to heighten the security posture of Building 20291 Room 103 located at

China Lake, CA for the Naval Air Warfare Center, Weapons Division.

Project Requirements:

Project work will begin TBD.

Building 20291 Room 103

1 Hirsch Model MX-8 Controller

1 Hirsch DS47L-SSP-TS-HL CAC Reader

1 Hirsch EBIC5 Cable

1 Hirsch AEB8 Input Board

1 Hirsch REB8 Relay Board

1 Hirsch MB9 Reader Mounting Box

1 Hirsch MELM-3 Door Module

1 Hirsch CR-SCM-CEV-USB Enrollment Station

1 Hirsch VEL35-VUE Software

1 Hirsch NMCI Velocity Server Owned

1 Altronix AL600UL-ACM Power Supply

1 Door Contacts For Door Status

1 Door Sweep

1 SCH ND80PDEU RHO 626 24V AE Lockset

1 Door Violation Alarm Systems

1 Misc. Connectors and Parts

1 Electrified Hinge

1 Office Processing

25 Cat5/6 Comm Cable

150 18/2 Power Cable

150 18/6 Reader Cable

150 22/4 Access Cable

a. Scope of Work: Contractor shall provide all labor and (CF) materials listed below.

b. Begin work date is TBD. Integrate the access control system on the NMCI network. Test to insure the system works.

c. The contractor shall provide all (CF) conduit, connectors and fittings as necessary to provide a complete and usable systems.

d. The Contractor will provide all labor to program and test the system.

e. Contractor shall provide a one-day response to any warranty issues pertaining the work provided by this contract.

f. Security clearance is not required, individuals will be under escort.

STATEMENT OF WORK FOR THE

IDS SECURITY SYSTEM FOR BUILDING

20291 ROOM 103 LOCATED AT CHINA LAKE.

Background:

The purpose of this project is to heighten the security posture of Building 20291 Room 103 located at

China Lake, CA for the Naval Air Warfare Center, Weapons Division.

Project Requirements:

Project work will begin TBD.

Building 20291 Room 103

1 DMP 550DEPCB Controller With ICOM-E

1 DMP 350A-G Controller Can

1 DMP 7060A-W Keypad

1 DMP 695-W Keypad Backbox

1 DMP ES501 Trans Cover

1 Bosch DS9370 360 Motion Detector

1 Sentrol 2707a Door Contact

1 Manbars And Crawl Space Bars

1 Patton 3241 Network Devices

1 5 Port Mini Switches

1 KC-2 Power Supply

4 Back Up Batteries

1 LED Alarm Status Indicators

1 Misc Conduit, Cable, Connectors and Parts

25 Cat 5e Co,, Cable

150 18/2 Security Cable

150 22/4 Security Cable

a. Scope of Work: Contractor shall provide all labor and (CF) materials listed below.

b. Begin work date is TBD. Integrate the access control system on the NMCI network. Test to insure the system works.

c. The contractor shall provide all (CF) conduit, connectors and fittings as necessary to provide a complete and usable systems.

d. The Contractor will provide all labor to program and test the system.

e. Contractor shall provide a one-day response to any warranty issues pertaining the work provided by this contract.

f. Security clearance is not required, individuals will be under escort.

Bldg 20291 Rm 103 ACES SOW