Bldg_20279_Room_218_SOW.pdf

PDF 374 KB Posted

Attached to
Security System Federal contract opportunity
Solicitation number
N6893617T0042
Issued by
Department of the Navy Naval Air Systems Command Naval Air Warfare Center

About this file

Bldg 20279 Room 218 SOW

View the file

Other files for this federal contract opportunity

Other files attached to Security System, newest first.
File Type Posted
Q&A.docx DOCX document
17-T-0042_RFQ_Amendment_2.docx DOCX document
17-T-0042_RFQ_Amendment.docx DOCX document
Bldg_20212_SOW.pdf PDF
Bldg_20303_Room_209_SOW.pdf PDF
Bldg_20291_Room_103_SOW.pdf PDF
17-T-0042_RFQ_Solicitation.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK FOR THE

ACCESS CONTROL FOR BUILDING

20279 ROOM 218 LOCATED AT CHINA LAKE.

Background:

The purpose of this project is to heighten the security posture of Building 20279 Room 218 located at

China Lake, CA for the Naval Air Warfare Center, Weapons Division.

Project Requirements:

Project work will begin TBD.

Building 20279 Room 218

1 Hirsch Model MX-2 Controller

1 Hirsch DS47L-SSP-TS CAC Readers

1 Hirsch EBIC5 Cable

1 Hirsch AEB8 Input Board

1 Hirsch REB8 Relay Board

1 Hirsch MB9 Reader Mounting Box

1 Hirsch MELM-3 Door Module

1 Hirsch CR-SCM-CEV-USB Enrollment Station

1 Hirsch VEL35-VUE Software

1 Hirsch NMCI Velocity Server Owned

1 Altronix AL600UL-ACM Power Supply

1 Door Contacts For Door Status

1 Door Sweep

1 SCH ND80PDEU RHO 626 24V AE Lockset

1 Door Violation Alarm Systems

1 Misc. Connectors and Parts

1 Electrified Hinge

1 Office Processing

25 Cat5/6 Comm Cable

150 18/2 Power Cable

150 18/6 Reader Cable

150 22/4 Access Cable

a. Scope of Work: Contractor shall provide all labor and (CF) materials listed below.

b. Begin work date is TBD. Integrate the access control system on the NMCI network. Test to insure the system works.

c. The contractor shall provide all (CF) conduit, connectors and fittings as necessary to provide a complete and usable systems.

d. The Contractor will provide all labor to program and test the system.

e. Contractor shall provide a one-day response to any warranty issues pertaining the work provided by this contract.

f. Security clearance is not required, individuals will be under escort.

STATEMENT OF WORK FOR THE

IDS SECURITY SYSTEM FOR BUILDING

20279 ROOM 218 LOCATED AT CHINA LAKE.

Background:

The purpose of this project is to heighten the security posture of Building 20279 Room 218 located at

China Lake, CA for the Naval Air Warfare Center, Weapons Division.

Project Requirements:

Project work will begin TBD.

Building 20279 Room 218

1 DMP XR550DEA-G Controller With ICOM-E

1 DMP 7060A-W Keypad

1 DMP 695-W Keypad Backbox

1 DMP ES501 Trans Cover

1 DMP 712-8 Zone Expander

2 Bosch ISC-PPR1-W16 Motion Detector

6 Bosch DS938Z 360 Motion Detectors

1 Sentrol 2707a Triple Bias Contacts

1 Patton 3241 Network Devices

1 5 Port Mini Switches

1 KC-2 Power Supply

4 Back Up Batteries

1 Altronix AL400ULX-PD8 Power Supply

1 LED Alarm Status Indicator

1 Misc Conduit, Cable, Connectors and Parts

25 Cat 5e Co,, Cable

150 18/2 Security Cable

250 22/4 Security Cable

a. Scope of Work: Contractor shall provide all labor and (CF) materials listed below.

b. Begin work date is TBD. Integrate the access control system on the NMCI network. Test to insure the system works.

c. The contractor shall provide all (CF) conduit, connectors and fittings as necessary to provide a complete and usable systems.

d. The Contractor will provide all labor to program and test the system.

e. Contractor shall provide a one-day response to any warranty issues pertaining the work provided by this contract.

f. Security clearance is not required, individuals will be under escort.

Bldg 20279 Rm 218 ACES SOW