| The following Questions were received in reference to Solicitation N68335-14-RFI-0160: | |
| Q 1. | The formula for Achieved Availability appears to be missing. Please provide it ? |
| Q 2. | The RFI states, "FAULT ISOLATION: The PAR and ILS built-in-test shall be capable of isolatingdetected faults to 1 L" |
| Is this a complete statement? What is "1 L"? |
| Q 3. | The RFI states, " PRIMARY COMMERCIAL ELECTRICAL POWER; 120/208 VAC, 60 Hz, 4 wire, three phase, 12.8 KVA" |
| Is 12.8 KVA the maximum power available to operate the system? In other words, the system should be able to function on a 12.8 KVA or less? |
The following answers to the above questions are provided below:
| A 1. | PAR AND ILS ACHIEVED AVAILABILITY (Aa) | |
| Achieved availability is measured by the following equation: | ||
| MTBM (MEAN TIME BETWEEN MAINTENANCE) | ||
| MTBM (MEAN TIME BETWEEN MAINTENANCE) + MMT (MEAN MAINTENANCE TIME) |
| A 2. | FAULT ISOLATION: | The PAR and ILS built-in-test shall be capable of isolating detected faults to 1 LRU > 95% of the time. |
| A 3. | PRIMARY COMMERCIAL POWER IS AVAILABLE |