TRANSDUCER SPECIFICATION

03 August 2017

CHARACTERISTIC REQUIREMENT

Transducer Style Xmtr/Rcvr Combination (without aid of transmit/receive switch)

Receive Characteristics

Free-Field Voltage Sensitivity (FFVS) (non-amplified)

-186dB//1V//1uPa @ 13kHz

FFVS Variance @ 7.5 to 15kHz +/- 10dB Variance

FFVS Variance @ 7.5 to 20kHz +/- 20dB Variance

XY-Plane Receive Beam Pattern variance @ 9kHz, 13kHz, and 17.2kHz

Omni-directional to +/- 2dB (see Figure 1)

XZ-Plane Beam Pattern variance @ 9kHz, 13kHz, and 17.2kHz

Not more than 12dB from Z axis +/- 135 degrees (see Figure 1)

Transmit Characteristics

Full Power Output 13kHz with input power of < 500 watts

Full Power Output Sound Pressure Level > 192dB//1uPa at 1m at 13kHz, continuously, without damage or degradation, for a duration of 1 hour

Output variance @ 7.5 to 15kHz Not more than 6dB

XY-Plane Transmit Beam Pattern variance @ 9kHz and 13kHz

Omni-directional to +/- 2dB (see Figure 1)

XZ-Plane Beam Pattern variance @ 9kHz and 13kHz

Not more than 12dB from Z axis +/- 135 degrees (see Figure 1)

In-Air Transmit Able to transmit in-air at Full Power Output without damage to transducer for up to 1 minute

Height 4.7 +/- 1 in

Weight 5.0 +/- 2.5 lbs

Diameter 4.25 in +/- 0.5 in

Max Operating Depth Unlimited

Baseplate Material, Dimensions, and Interface

See attached Interface Control Drawing (ICD)

Electrical Connections Solder Tab (see attached ICD)

Hydrostatic Pressure Test Hold for minimum of 10 minutes at 1000 lbs per square inch (gauge)

Electrical Test (before and after Hydrostatic Pressure Test)

Impedance and Phase from 5kHz to 20kHz Capacitance and dissipation at 9kHz, 13kHz, 17.2kHz (single point values) High Potential (Hipot) test

TRANSDUCER SPECIFICATION

03 August 2017

CHARACTERISTIC REQUIREMENT

Acoustic Test (following Hydrostatic Pressure Test)

Open circuit FFVS from 5kHz to 20kHz Receive XY-plane beam patterns at 9kHz, 13kHz, and 17.2kHz Receive XZ-plane beam patterns at 9kHz, 13kHz, and 17.2kHz Transmit Voltage Response (TVR) from 5kHz to 20kHz Sound level plot demonstrating 192dB//1uPa at

1 meter at 13kHz capability and 186dB//1uPa at 1 meter at 9kHz Transmit XY-plane beam patterns at 9kHz and

13kHz Transmit XZ-plane beam patterns at 9kHz and

13kHz

Figure 1 – Axes Orientation

+X‐X

+Z

‐Z

‐Y

+Y

XZ

plane

File details come from the government source that posted it. Updated .