GOV'T MATERIAL

ITEM NONOMENCLATURETECHNICAL SPECIFICATIONSMFR/VENDORPART NO.BRAND NAME OR EQUIVALENTU/IQTY REQD
1UPS, RACK MOUNT, 1500VA 2RUMinimum Output Volt Amp Capacity (VA):1500. Minimum Output kVA Capacity (kVA):1.5. Minimum Output Watt Capacity (Watts):1350. Minimum Output kW Capacity (kW):1.35. Maximum output capacity ratings is reduced to 1215 watts at 115V nominal and 1080 watts at 100V nominal; Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts / 115V 850 watts / 110V 804 watts / 100V 756 watts), Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) Power Factor:0.9. Crest Factor:3:1. Nominal Output Voltage(s) Supported:100V; 110V; 115V; 120V; 127V. Nominal Voltage Details:120V factory-default nominal voltage; Less than 3% THD for linear loads and less than 5% for non-linear computer loads. Frequency Compatibility:50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion. Output Voltage Regulation (Line Mode):+/- 2%. Output Voltage Regulation (Economy Line Mode):+/- 10%. Output Voltage Regulation (Battery Mode):+/- 3%. Output Receptacles:(6) 5-15R Load Management Receptacles:Two switchable three-outlet 5-15R load banks. Output AC Waveform (AC Mode):Pure Sine wave. Output AC Waveform (Battery Mode):Pure Sine wave. Individually Controllable Load Banks:Yes. Rated input current (Maximum Load):12A. Nominal Input Voltage(s) Supported:100V AC; 110V AC; 115V AC; 120V AC; 127V AC. Nominal Input Voltage Description:120V factory default. UPS Input Connection Type:5-15P. Input Circuit Breakers:20A. UPS Input Cord Length (ft.):10. UPS Input Cord Length (m):3.1. Recommended Electrical Service:15A 120V. Input Phase:Single-Phase. Full Load Runtime (min.):4.2 min. (1350w). Expandable Battery Runtime:Extended runtime supported via optional external battery packs. DC System Voltage (VDC):48. Battery Recharge Rate (Included Batteries):Less than 3 hours recharge to 90%; Add 6 hours per BP48V27-2US (typical, full load discharge). Voltage Regulation Description:Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages. Overvoltage Correction :Corrects overvoltages to 150V (0-100% load). Undervoltage Correction :Corrects undervoltages to 100V at full load (90V at 100V nominal). Severe Undervoltage Correction:Corrects brownouts to 70V (70% load) & 55V (33% load). Front Panel LCD Display:Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, and alarm function. 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options. Alarm Cancel Operation:Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available. Audible Alarm:Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions. 7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status. UPS AC Suppression Joule Rating:570. UPS AC Suppression Response Time:Instantaneous. UPS Dataline Suppression:1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet. EMI / RFI AC Noise Suppression:Yes.

PHYSICAL

Installation Form Factors Supported with Included Accessories:4 post 19 inch rackmount Included Mounting Accessory Description:Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) Installation Form Factors Supported with Optional Accessories:2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) Optional Mounting Accessory Notes:Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support Primary Form Factor:Rackmount UPS Power Module Dimensions (hwd, cm):8.89 x 44.45 x 46.99 Rack Height:2U Minimum Required Rack Depth without External Battery Pack (cm):55 Minimum Required Rack Depth with External Battery Pack (cm):65 Minimum Required Rack Depth without External Battery Pack (in.):21.5 Minimum Required Rack Depth with External Battery Pack (in.):25.5 UPS Power Module Weight (kg):20.50 Shipping Dimensions (hwd / cm):23.37 x 59.18 x 48.77 Shipping Weight (kg):26.31 Cooling Method:Fan UPS Housing Material:Steel Primary UPS Height (mm):89 Primary UPS Width (mm):445 Primary UPS Depth (mm):470

ENVIRONMENTAL

Operating Temperature Range:+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range:+5 to +122 degrees Fahrenheit / -20 to +40 degrees Celsius with batteries; -13 to +131 Fahrenheit / -25 to +55 degrees Celsius without batteries Relative Humidity:0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) :455 AC Economy Mode BTU / Hr. (Full Load):294 Battery Mode BTU / Hr. (Full Load) :559 AC Economy Mode Efficiency Rating (100% Load):94% Operating Elevation (ft.):0-3000m / 0-10,000 ft.

Audible Noise:45 dBA at 1m front side Operating Elevation (m):0 - 3000 m

COMMUNICATIONS

Communications Interface:USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards:SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD Network Monitoring Port Description:Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications PowerAlert Software:For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable:USB and DB9 cabling included WatchDog Compatibility:Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time :Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode Low Voltage Transfer to Battery Power (Setpoint):100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load High Voltage Transfer to Battery Power (Setpoint):150

CERTIFICATIONS

UPS Certifications:Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to UL1778 (USA)TRIPPLITESU1500RTXLCD2UEQUIVALENTEA2
2PACK, BATTERY, UPSInput Phase:Single-Phase

Battery DC System Voltage (VDC):48 Battery Pack Accessory (Optional): 48VDCSPLITTER (*Limit 2 BP48V24-2U with 48VDCSPLITTER) UPS Connection:Attached cable with blue 175 amp DC connector Typical Battery Lifespan:4-6 years typical (North America) Installation Form Factors Supported with Included Accessories:4 post 19 inch rackmount Installation Form Factors Supported with Optional Accessories:2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND); 2-4 post front rail rackmount (UPSHDEARKIT) Minimum Required Rack Depth (cm):52.07 Shipping Dimensions (hwd / cm):22.61 x 59.44 x 49.53 Shipping Weight (kg):31.84 Unit Dimensions (hwd / cm):8.9 x 44.5 x 34.3 Unit Weight (kg):28.58 External Battery Pack Form Factor:Rack/Tower

Certifications:Tested to UL, CE, NOMTRIPPLITEBP48V24-2UEQUIVALENTEA2
3SWITCH, NETWORK, IPCatalyst, 8-port network switch with CAB-TA-NA AC Type A Power CableCISCOWS-C3560CX-8TC-SBRAND NAMEEA4
4MODULE, TRANCEIVER, SWITCH1000BASE-LX/LH SFP transceiver module, MMF/SMF, 1310nm, DOMCISCOGLC-LH-SMD++=BRAND NAMEEA4
5KIT, RACKMOUNT SWITCH19in RackMount for Catalyst 3560,2960,ME-3400 Compact SwitchCISCORCKMNT-19-CMPCT=BRAND NAMEEA4
6LICENSE, CATALYST3560-CX IP Base to IP Services Electronic RTU License with L-C3560CX-RTU= SW LicenseCISCOL-C3560CX-12-S-EBRAND NAMEEA4
7POWER SUPPLY, 12VDC WITH ENCLOSUREInput Input 115VAC, 60Hz, 2.6A. Input fuse rated @ 5A/250V. Output 12VDC output. 10A continuous supply current.Output fuse rated @ 15A/32V. Filtered and electronically regulated output. Short circuit and thermal overload protection. Battery Backup Built-in charger for sealed lead acid or gel type batteries.

Automatic switch over to stand-by battery when AC fails.

Supervision AC fail supervision (form "C" contacts).

Notification trigger is selectable for 30 seconds (factory set) or 6 hours.

Low battery supervision (form "C" contacts).

Battery presence supervision (form "C" contacts).

Visual Indicators AC input and DC output LED indicators.

Temperature Operating 0 to 49° C (32 to 120° F ).

Storage - 20 to 70° C ( - 4 to 158° F).

Relative Humidity 85% +/- 5% BTU/Hr. (approx.): 61 BTU/Hr.

System AC input VA requirement: 299VA.

Enclosure: Wall mount enclosure for indoor use. Accommodates up to one (1) 12VDC/12AH Batteries. Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D). 1.125" and 1.375" combination knockouts.ALTRONIXAL1012ULXEQUIVALENTEA5
8POWER SUPPLY, 24VDC WITH ENCLOSUREInput Input 115VAC, 60Hz, 4.2A. Input fuse rated @ 3.5A/250V. Output 24VDC output. 10A continuous supply current.Output fuse rated @ 15A/32V. Filtered and electronically regulated output. Short circuit and thermal overload protection. Battery Backup Built-in charger for sealed lead acid or gel type batteries.

Automatic switch over to stand-by battery when AC fails.

Supervision AC fail supervision (form "C" contacts).

Notification trigger is selectable for 30 seconds (factory set) or 6 hours.

Low battery supervision (form "C" contacts).

Battery presence supervision (form "C" contacts).

Visual Indicators AC input and DC output LED indicators.

Temperature Operating 0 to 49° C (32 to 120° F ).

Storage - 20 to 70° C ( - 4 to 158° F).

Relative Humidity 85% +/- 5% BTU/Hr. (approx.): 61 BTU/Hr.

System AC input VA requirement: 483VA.

Enclosure: Wall mount enclosure for indoor use. Accommodates up to two (2) 12VDC/12AH Batteries. Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D). 1.125" and 1.375" combination knockouts.ALTRONIXAL1024ULXEQUIVALENTEA3
9DISTRIBUTION BLOCK, POWER 8-OUTPUT, FUSEDInput Up to 28VAC or 28VDC operation @ 12A max. Outputs Eight (8) individually fused outputs. Fuses rated @ 3.5A/250V

Surge suppression. LED Indicators Power LED indicator. Power ON/OFF switch.

Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity 85% +/- 5%.

Dimensions (approximate): 3.25"W x 5.25"L x 1"H (82.55 mm W x 133.35 mm L x 25.4 mm H).ALTRONIXPD8EQUIVALENTEA12
10DISTRIBUTION BLOCK, POWER 16-OUTPUTInput Up to 28VAC or 28VDC operation @ 12A max. Outputs Eight (8) individually fused outputs. Fuses rated @ 3.5A/250V

Surge suppression. LED Indicators Power LED indicator. Power ON/OFF switch.

Temperature Operating: 0° C to 49° C (32° F to 120° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity 85% +/- 5%. Dimensions: 3.25"Wx5.25"Lx1"HALTRONIXPD16WEQUIVALENTEA5
11BATTERY, 12VDCRechargeable Sealed Lead Acid Battery 12VDC, 12AH Gel Sealed Battery, with quick disconnect tabs, Maximum dimensions L:5.94" W: 3.86" HT: 3.86"POWER SONICPS-12120EQUIVALENTEA8
12SENSOR, MOTION, REQUEST TO EXIT12-30VDC Sensor, Passive Infrared with Sequential Logic Input and 8'x10' detection area.BOSCHDS160BRAND NAMEEA10
13SENSOR, MOTION 360-DEGREE9-15VDC Sensor, Passive Infrared with 70' detection rangeBOSCHDS939BRAND NAMEEA30
14PLATE, TRIM FOR DS160Mounting Plate for DS160 on Single Gang BoxBOSCHTP160BRAND NAMEEA10
15SENSOR, DOOR, HIGH SECURITY SINGLE CONTACTUL634 Level 2 SPDT Door Sensor, Surface MountMAGNASPHEREL2S-000BRAND NAMEEA10
16SENSOR, DOOR, HIGH SECURITY DUAL CONTACTUL634 Level 2 DPDT Door Sensor, Surface MountMAGNASPHEREL2D-010BRAND NAMEEA10
17SENSOR, DOOR, HIGH SECURITYUL634 Level 1 DPDT Door Sensor, Surface MountGE SECURITY2707AD-LBRAND NAMEEA10
18SENSOR, TAMPER, PLUNGER TYPESPDT Switch with 3-position Push-Momentary Pull-Maintained Threaded Plunger, Screw Terminations. Plunger maximum free position 0.375", plunger minimum operating position 0.203", plunger maximum depressed condition 0.125". Contact current maximum: 4A (DC), Contact voltage maximum: 250V (DC).HONEYWELL2AC59EQUIVALENTEA10
19SENSOR, MOTION, OUTDOOR8.5-20VDC Dual Technology, Infrared and Microwave Sensor with SPDT Dry Contact Relay, Outdoor Rated, -30-130FSDISDI-76XL-MILBRAND NAMEEA8
20STRIKE, DOORSS Tamper-resistant 12/24VDC Electric Strike, ANSI/BHMA A156.31, Grade 1, UL 1034, NFPA-252 compliantHES1006CS-630-LBMBRAND NAMEEA6
21ENCLOSURE, 30"x20"x6"NEMA4,12,13 30”x20”x6” Enclosure with Mounting Panel for 28.2”x18.2” mounting plate 16 gauge steel • Seams continuously welded and ground smooth • Corner-formed doors • Simple easy-to-remove and install hinge pins with captivation clip • High-torque threadless studs and fasteners on door • Minimum-width body flange provides maximum door opening • Door opens 210 degrees • External formed body flange • Panel mounting studs fit optional CONCEPT panels and other accessories • Mounting holes in back of body for direct mounting or optional external mounting brackets • Removable door with hidden hinges for clean, aesthetic appearance • Seamless foam-in-place gasket • Quarter-turn slotted latch • Hardware kit with panel mounting nuts, panel grounding hardware and sealing washersHOFFMANCSD30206LGEQUIVALENTEA2
22ENCLOSURE, 20"x24"x6"NEMA4,12,13 20"x24"x6" Steel Enclosure with Mounting Panel for 20..2”x18.2” mounting plate 16 gauge steel • Seams continuously welded and ground smooth • Corner-formed doors • Simple easy-to-remove and install hinge pins with captivation clip • High-torque threadless studs and fasteners on door • Minimum-width body flange provides maximum door opening • Door opens 210 degrees • External formed body flange • Panel mounting studs fit optional CONCEPT panels and other accessories • Mounting holes in back of body for direct mounting or optional external mounting brackets • Removable door with hidden hinges for clean, aesthetic appearance • Seamless foam-in-place gasket • Quarter-turn slotted latch • Hardware kit with panel mounting nuts, panel grounding hardware and sealing washersHOFFMANCSD20246LGEQUIVALENTEA2
23PLATE, MOUNTING FOR CSD302028.2"x18.2" 12-Ga Painted Steel Plate for Mounting Inside CSD30206 EnclosuresHOFFMANCP3020EQUIVALENTEA2
24PLATE, MOUNTING FOR CSD202422.2"x18.2" 12-Ga Painted Steel Plate for Mounting Inside CSD20246 EnclosuresHOFFMANCP2420EQUIVALENTEA2
25SET, KEY LOCK AND HANDLEKey Lock and Handle Set for Hoffman EnclosureHOFFMANCWHKEQUIVALENTEA4
26CABLE, RISER, 22-822AWG, 8-Conductor Stranded Shielded Riser-rated Cable 1000'HONEYWELL22071109EQUIVALENTEA10
27CABLE, CM 22-422AWG, 4-Conductor Stranded Unshielded Cable 1000'HONEYWELL21041109EQUIVALENTEA10
28CABLE, RISER, 22-422AWG, 4-Conductor Stranded Shielded Riser-rated Cable 1000'HONEYWELL22041109EQUIVALENTEA1
29CABLE, RISER, 18-418AWG, 4-Conductor Stranded Unshielded Riser-rated Cable 1000'HONEYWELL21151109EQUIVALENTEA10
30CABLE, RISER, 18-218AWG, 2-Conductor Stranded Unshielded Riser-rated Cable 1000'HONEYWELL21141109EQUIVALENTEA5
31CABLE, OUTDOOR, 18-618AWG, 6-Conductor Stranded Outdoor-rated Cable 1000'HONEYWELL41581008EQUIVALENTEA8
32CABLE, RISER, CAT6CAT6 23AWG, 4-Pair Riser-rated Cable 1000'HONEYWELL50922101EQUIVALENTEA2
33RACK, COMPUTER EQUIPMENTThe enclosure shall be UL listed to UL60950-1 (Standard for Information Technology

and Communications Equipment, Cabinet, Enclosure and Rack Systems.) and also shall be 19” EIA 310-D compliant.

Overall dimensions of enclosure shall be 48”H with width of 24” and a depth of 32”. Enclosure shall be made out of a minimum of 16-gauge cold rolled steel.

Enclosure shall have front and rear doors with lockable swing handles. Doors to be field reversible without additional hardware. All doors and sides to be gasketed w/ neoprene foam and have a #10-32 x ½ copper ground stud. Top panel shall be removable with horseshoe knockouts. Side panels shall have quick release latches and be locking.

Mounting rails shall be fully adjustable universal (M6) with RMU markings.

Rails shall be #12 Ga. Powder-coated and have round cable pass through holes with cable management tie down slots both vertical and horizontal.

Bottom of enclosure shall have two (2) #10-32 x ½ copper ground studs plus four (4) 3/4” thru holes for bolting to floor and provision for casters and or leveling glides. Floor access opening shall be 11.50”W x 14.75”D with #10-32 blind treaded inserts for optional bottom panels.

Manufacturer shall ship enclosure assembled including accessories like shelves & power strips.

Manufacturer shall be ISO 9001:2000 RegisteredGREAT LAKESGL480E-2432SEQUIVALENTEA1
34RACK, COMPUTER EQUIPMENTThe enclosure shall be UL listed to UL60950-1 (Standard for Information Technology

and Communications Equipment, Cabinet, Enclosure and Rack Systems.) and also shall be 19” EIA 310-D compliant.

Overall dimensions of enclosure shall be 30”H with width of 24” and a depth of 32”. Enclosure shall be made out of a minimum of 16-gauge cold rolled steel.

Enclosure shall have front and rear doors with lockable swing handles. Doors to be field reversible without additional hardware. All doors and sides to be gasketed w/ neoprene foam and have a #10-32 x ½ copper ground stud. Top panel shall be removable with horseshoe knockouts. Side panels shall have quick release latches and be locking.

Mounting rails shall be fully adjustable universal (M6) with RMU markings.

Rails shall be #12 Ga. Powder-coated and have round cable pass through holes with cable management tie down slots both vertical and horizontal.

Bottom of enclosure shall have two (2) #10-32 x ½ copper ground studs plus four (4) 3/4” thru holes for bolting to floor and provision for casters and or leveling glides. Floor access opening shall be 11.50”W x 14.75”D with #10-32 blind treaded inserts for optional bottom panels.

Manufacturer shall ship enclosure assembled including accessories like shelves & power strips.

Manufacturer shall be ISO 9001:2000 Registered.GREAT LAKESGL300E-2432SEQUIVALENTEA1
35ESTIMATED SHIPPINGDOOR TO DOOR SHIPPING VIA COMMERCIAL AIR TO JAPANAU1
REQUIREMENT FOR BRAND NAME EQUIPMENT FOR ESS INSTALLATION IN JAPAN. IF YOU ARE INCLUDING SHIPPING COST IN THE PRICES IT MUST BE EXPLICITYLY STATED ON YOUR QUOTE.
“SHIPPING NOT PRICED SEPARATELY, TOTAL PRICE INCLUDES SHIPPING TO JAPAN”. MODIFICATION FOR SHIPPING NOT QUOTED WILL NOT BE AUTHORIZED. IF YOU LIST SHIPPING AS A SEPARATE CLIN YOU MUST ALSO INVOICE SEPARATELY
AND UPLOAD PROOF OF ACTUAL SHIPPING COST. ANY ITEM WITH A UNIT PRICE OF $5K OR GREATER WILL REQUIRE IUID LABELS WHICH CAN BE ATTACHED TO THE ITEM OR PLACED LOOSELY IN THE PACKAGING.
ALL ITEMS MUST BE BRAND NEW AND UN-OPENED IN THE ORIGINAL PACKAGING. PLEASE SEE ATTACHED FOR DELIVERY ADDRESS, AND TO ENTER PRICING AND DELIVERY INFORMATION.
ENTER A NEW CLIN BELOW THE ORIGINAL LINE FOR ANY EOL OR REPLACEMENT ITEM IF APPLICABLE.
SHIP TO ADDRESS:
UNITED STATES ARMY CORP OF ENGINEERS
ATTN: IAN TAKENISHI
KADENA AIR FORCE BASE
BLDG 762, HANGAR 3
NAKAGAMI-GUN, OKINAWA JAPAN 904-0315

File details come from the government source that posted it.